At least 811 records · Page 45

Review of Kaufman thruster development at the Lewis Research Center, 1973

Two thruster sizes are studied. One, a small 5-cm or 8-cm size is for spacecraft station keeping. The other, 30-cm (130 mN thrust), is for a thruster array to do primary solar electric propulsion. A 5-cm thruster (1.8 mN) has recently completed 9715 hr of life testing. Use of dished grids in the 30-cm thruster has increased beam current from 2 to 5 A. The total thrust system mass is compared for present small thrusters at different operating conditions for station keeping of synchronous satellites.

Kerslake, W. R.↗

Description of crimp contact

The Tapecon Mark 2 - no-strip-crimp connection is described. Results of humidity, thermal shock, corrosion, and life tests are included.

Wigby, J.↗

Self-healing fuse development

The mercury-filled self-healing fuses developed for this program afford very good protection from circuit faults with rapid reclosure. Fuse performance and design parameters have been characterized. Life tests indicate a capability of 500 fuse operations. Fuse ratings are 150 v at 5, 15, 25 and 50 circuit A. A series of sample fuses using alumina and beryllia insulation have been furnished to NASA for circuit evaluation.

Jones, N. D.↗

Investigation of hollow cathode performance for 30-cm thrusters

A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, insert position, emission current, cathode temperature, orifice diameter, and mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes. The results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages are also presented.

Mirtich, M. J.↗

An empirical Bayes approach for the Poisson life distribution.

A smooth empirical Bayes estimator is derived for the intensity parameter (hazard rate) in the Poisson distribution as used in life testing. The reliability function is also estimated either by using the empirical Bayes estimate of the parameter, or by obtaining the expectation of the reliability function. The behavior of the empirical Bayes procedure is studied through Monte Carlo simulation in which estimates of mean-squared errors of the empirical Bayes estimators are compared with those of conventional estimators such as minimum variance unbiased or maximum likelihood. Results indicate a significant reduction in mean-squared error of the empirical Bayes estimators over the conventional variety.

Canavos, G. C.↗

Hydrogen evolution in nickel-water heat pipes.

A study was made of the evolution of hydrogen gas in nickel-water heat pipes for the purpose of investigating methods of accelerated life testing. The data were analyzed in terms of a phenomenological corrosion model of heat pipe degradation which incorporates corrosion and oxidation theory and contains parameters which can be determined by experiment. The gas was evolved with a linear time dependence and an exponential temperature dependence with an activation energy of 1.03 x 10 to the minus 19th joules. A flow-rate dependence of the gas evolution was found in the form of a threshold. The results were used to predict usable lifetimes of heat pipes operated at normal operating conditions from results taken under accelerated operating conditions.

Anderson, W. T.↗

Polyurethane retainers for ball bearings

Evaluation of a new ball bearing retainer material is reported. A special composite polyurethane foam ball retainer has been developed that has virtually zero wear, is chemically inert to hydrocarbon lubricants, and stores up to 60 times as much lubricant per unit volume as the most commonly used retainer material, cotton phenolic. This new retainer concept shows promise of years of ball bearing operation without reoiling, based on life testing in high vacuum.

Christy, R. I.↗

Improvement program for polycarbonate capacitors

Hermetically sealed, wound, AC, polycarbonate capacitors incorporating design improvements recommended in a previous study were designed and built. A 5000 hour, 400 Hz ac life test was conducted using 384 of these capacitors to verify the adequacy of the design improvements. The improvements incorporated in the capacitors designed for this program eliminated the major cause of failure found in the preceding work, termination failure. A failure cause not present in the previous test became significant in this test with capacitors built from one lot of polycarbonate film. The samples from this lot accounted for 25 percent of the total test complement. Analyses of failed samples showed that the film had an excessive solvent content. This solvent problem was found in 37 of the total 46 failures which occurred in this test. The other nine were random failures resulting from causes such as seal leaks, foreign particles, and possibly wrinkles.

Bailey, R. R.↗

Selected reliability studies for the NERVA program

An investigation was made into certain methods of reliability analysis that are particularly suitable for complex mechanisms or systems in which there are many interactions. The methods developed were intended to assist in the design of such mechanisms, especially for analysis of failure sensitivity to parameter variations and for estimating reliability where extensive and meaningful life testing is not feasible. The system is modeled by a network of interconnected nodes. Each node is a state or mode of operation, or is an input or output node, and the branches are interactions. The network, with its probabilistic and time-dependent paths is also analyzed for reliability and failure modes by a Monte Carlo, computerized simulation of system performance.

Hoover, S. V.↗

Investigation of hollow cathode performance for 30-cm thrusters

A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, the insert position, the emission current, the cathode temperature, the orifice diameter, and the mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes of interest. Also presented are the results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages.

Mirtich, M. J.↗

Evaluation program for secondary spacecraft cells

The cycle life tests to determine the performance capabilities of packs of cells under different loads and temperature conditions are reported. Results are summarized, and the failure of 14 failed cells is analyzed. It was found that the main cause of failure was separator deterioration and migration of the negative plate material.

Harkness, J. D.↗

Investigation of a catalytic gas generator for the Space Shuttle APU

An investigation was conducted to establish the capability of a monopropellant hydrazine catalytic gas generator to meet the requirements specified for the Space Shuttle APU. Detailed analytical and experimental studies were conducted on potential problem areas including long-term nitriding effects on materials, design variables affecting catalyst life, vehicle vibration effects, and catalyst oxidation/contamination. A full-scale gas generator, designed to operate at a chamber pressure of 750 psia and a flow rate of 0.36 lbm/sec, was fabricated and subjected to three separate life test series. The objective of the first test series was to demonstrate the capability of the gas generator to successfully complete 20 simulated Space Shuttle missions in steady-state operation. The gas generator was then refurbished and subjected to a second series of tests to demonstrate the pulse-mode capability of the gas generator during 20 simulated missions. The third series of tests was conducted with a refurbished reactor to further demonstrate pulse-mode capability with a modified catalyst bed.

Emmons, D. L.↗

Systems design of long-life systems

A long-life system is defined as a system which cannot be life-tested in its operational environment. Another restriction is that preventive maintenance and repair shall be either impossible or economically disadvantageous. Examples of such systems include planetary spacecraft, communication satellites, undersea telephone cables, and nuclear power plants. The questions discussed are related to the implementation of system functions, approaches to determine the required level of system reliability, and aspects of tradeoffs between requirements and reliability.

Miles, R. F., Jr.↗

An aneroid pressure sensor for constant-level balloons

The pressure sensor for the Tropical Wind Energy conversion and Reference Level Experiment (TWERLE) is described. Key design features of the sensor are: capacitive coupling, reference at midrange, up-down counting, passive oven, storage at flight pressure and prelaunch calibration. Sensor specifications are given which are based on the production results of 440 units. Drift, as estimated from simulated life tests, is 1 mb per 6 months. The overall weight of the sensor, including thermal package, is 180 g.

Levanon, N.↗

Technological development of high energy density capacitors

A study was conducted to develop cylindrical wound metallized film capacitors rated 2 micron F 500 VDC that had energy densities greater than 0.1J/g. Polysulfone (PS) and polyvinylidene (PVF2) were selected as dielectrics. Single film PS capacitors of 0.2J/g (uncased) were made of 3.75 micron material. Single film PVF2 capacitors of 0.19J/g (uncased) were made of 6.0 micron material. Corona measurements were made at room temperature, and capacitance and dissipation factor measurements were made over the ranges 25 C to 125 C and 120 Hz to 100 kHz. Nineteen of twenty PVF2 components survived a 2500 hour dc plus ac life test. Failure analyses revealed most failures occurred at wrinkles, but some edge failures were also seen. A 0.989g case was designed. When the case was combined with the PVF2 component, a finished energy density of 0.11J/g was achieved.

Parker, R. D.↗

Room-temperature-operation visible-emission semiconductor diode lasers

There were two main approaches taken to develop shorter wavelength lasers. (1) Based on (AlGa)As and liquid-phase epitaxy, significant new results were obtained: Properties of these laser diodes (power output, spectra, and beam patterns), materials considerations, laser theory, and growth problems are discussed. The design of (AlGa)As layers is discussed from the vertical point of view, and various design curves are given. Horizontal structural requirements are also discussed. Experimental results from measurements done as a function of hydrostatic pressure are correlated with other results. (2) The first heterojunction laser structures using GaAs sub l-x P sub x and In sub y Ga sub l-y P at compositions, where the lattice constants are matched, were grown using vapor-phase growth technology and are described in detail, including experimental device results. Threshold current densities from 3,000 to 5,000 A per sq cm. and emission wavelengths from 6,520 A to 6,640 A were obtained at 77 K. The limiting factor in these devices is nonradiative recombination at the heterojunctions. Life tests on facet-coated (AlGa)As CW diodes are reported.

Ladany, I.↗

Physical properties of thin-film field emission cathodes with molybdenum cones

Field emission cathodes fabricated using thin-film techniques and electron beam microlithography are described, together with effects obtained by varying the fabrication parameters. The emission originates from the tip of molybdenum cones that are about 1.5 micron tall with a tip radius around 500 A. Such cathodes have been produced in closely packed arrays containing 100 and 5000 cones as well as singly. Maximum currents in the range 50-150 microamp per cone can be drawn. Life tests with the 100-cone arrays drawing 2 mA total emission (or 3 A per sq cm) have proceeded in excess of 7000 hr with about a 10% drop in emission current. Studies are presented of the emission characteristics and current fluctuation phenomena. It is tentatively concluded that the emission arises from only one or a few atomic sites on the cone tips.

Spindt, C. A.↗

Evaluation of commercially-available spacecraft-type heat pipes

As part of an effort to develop reliable, cost effective spacecraft thermal control heat pipes, life tests on 30 commercially available heat pipes in 10 groups of different design and material combinations were conducted. Results for seven groups were reported herein. Materials are aluminum and stainless steel, and working fluids are methanol and ammonia. The formation of noncondensible gas was observed for times exceeding 11,000 hours. The heat transport capacities of the pipes were also determined.

Kaufman, W. B.↗