Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

State-of-the-art for large area high resolution gray scale and full color AC plasma flat panel displays

A development status evaluation is presented for gas plasma display technology, noting how tradeoffs among the parameters of size, resolution, speed, portability, color, and image quality can yield cost-effective solutions for medical imaging, CAD, teleconferencing, multimedia, and both civil and military applications. Attention is given to plasma-based large-area displays' suitability for radar, sonar, and IR, due to their lack of EM susceptibility. Both monochrome and color displays are available.

Stoller, Ray A.↗

Dual-Channel Multi-Purpose Telescope

A dual-channel telescope allows for a wide-field telescope design wit h a good, narrow field channel of fewer surfaces for shorter-wavelen gth or planet-finding applications. The design starts with a Korsch three-mirror-anastigmat (TMA) telescope that meets the mission criter ia for image quality over a wide field of view. The internal image a t the Cassegrain focus is typically blurry due to the aberration bala ncing among the three mirrors. The Cassegrain focus is then re-optim ized on the axis of the system where the narrow field channel instru ment is picked off by bending the primary mirror.

Howard, Joseph M.↗

Wavefront Sensing Analysis of Grazing Incidence Optical Systems

Wavefront sensing is a process by which optical system errors are deduced from the aberrations in the image of an ideal source. The method has been used successfully in near-normal incidence, but not for grazing incidence systems. This innovation highlights the ability to examine out-of-focus images from grazing incidence telescopes (typically operating in the x-ray wavelengths, but integrated using optical wavelengths) and determine the lower-order deformations. This is important because as a metrology tool, this method would allow the integration of high angular resolution optics without the use of normal incidence interferometry, which requires direct access to the front surface of each mirror. Measuring the surface figure of mirror segments in a highly nested x-ray telescope mirror assembly is difficult due to the tight packing of elements and blockage of all but the innermost elements to normal incidence light. While this can be done on an individual basis in a metrology mount, once the element is installed and permanently bonded into the assembly, it is impossible to verify the figure of each element and ensure that the necessary imaging quality will be maintained. By examining on-axis images of an ideal point source, one can gauge the low-order figure errors of individual elements, even when integrated into an assembly. This technique is known as wavefront sensing (WFS). By shining collimated light down the optical axis of the telescope and looking at out-of-focus images, the blur due to low-order figure errors of individual elements can be seen, and the figure error necessary to produce that blur can be calculated. The method avoids the problem of requiring normal incidence access to the surface of each mirror segment. Mirror figure errors span a wide range of spatial frequencies, from the lowest-order bending to the highest order micro-roughness. While all of these can be measured in normal incidence, only the lowest-order contributors can be determined through this WFS technique.

Rohrbach, Scott↗

Surface Inspection Tool for Optical Detection of Surface Defects

The Space Shuttle Orbiter windows were damaged both by micrometeor impacts and by handling, and required careful inspection before they could be reused. The launch commit criteria required that no defect be deeper than a critical depth. The shuttle program used a refocus microscope to perform a quick pass/fail determination, and then followed up with mold impressions to better quantify any defect. However, the refocus microscope is slow and tedious to use due to its limited field of view, only focusing on one small area of glass at a time. Additionally, the unit is bulky and unable to be used in areas with tight access, such as defects near the window frame or on the glass inside the Orbiter due to interference with the dashboard. The surface inspection tool is a low-profile handheld instrument that provides two digital video images on a computer for monitoring surface defects. The first image is a wide-angle view to assist the user in locating defects. The second provides an enlarged view of a defect centered in the window of the first image. The focus is adjustable for each of the images. However, the enlarged view was designed to have a focal plane with a short depth. This allows the user to get a feel for the depth of different parts of the defect under inspection as the focus control is varied. A light source is also provided to illuminate the defect, precluding the need for separate lighting tools. The software provides many controls to adjust image quality, along with the ability to zoom digitally the images and to capture and store them for later processing.

Nurge, Mark↗

Lessons from Astrobiological Planetary Analogue Exploration in Iceland: Biomarker Assay Performance and Downselection

Understanding the sensitivity of biomarker assays to the local physicochemical environment, and the underlying spatial distribution of the target biomarkers in 'homogeneous' environments, can increase mission science return. We have conducted four expeditions to Icelandic Mars analogue sites in which an increasingly refined battery of physicochemical measurements and biomarker assays were performed, staggered with scouting of further sites. Completed expeditions took place in 2012 (location scouting and field assay use testing), 2013 (sampling of two major sites with three assays and observational physicochemical measurements), 2015 (repeat sampling of prior sites and one new site, scouting of new sites, three assays and three instruments), and 2016 (preliminary sampling of new sites with analysis of returned samples). Target sites were geologically recent basaltic lava flows, and sample loci were arranged in hierarchically nested grids at 10 cm, 1 m, 10 m, 100 m, and >1 km order scales, subject to field constraints. Assays were intended to represent a diversity of potential biomarker types (cell counting via nucleic acid staining and fluorescence microscopy, ATP quantification via luciferase luminescence, and relative DNA quantification with simple domain-level primers) rather a specific mission science target, and were selected to reduce laboratory overhead, require limited consumables, and allow rapid turnaround. All analytical work was performed in situ or in a field laboratory within a day's travel of the field sites unless otherwise noted. We have demonstrated the feasibility of performing ATP quantification and qPCR analysis in a field-based laboratory with single-day turnaround. The ATP assay was generally robust and reliable and required minimal field equipment and training to produce a large amount of useful data. DNA was successfully extracted from all samples, but the serial-batch nature of qPCR significantly limited the number of primers (hence classifications) and replicates that could be run in a single day. Fluorescence microscopy did not prove feasible under the same constraints, primarily due to the large number of person-hours required to view, analyze, and record results from the images; however, this could be mitigated with higher-quality imaging instruments and appropriate image analysis software.

Planetary↗

Iterative methods for dose reduction and image enhancement in tomography

A system and method for creating a three dimensional cross sectional image of an object by the reconstruction of its projections that have been iteratively refined through modification in object space and Fourier space is disclosed. The invention provides systems and methods for use with any tomographic imaging system that reconstructs an object from its projections. In one embodiment, the invention presents a method to eliminate interpolations present in conventional tomography. The method has been experimentally shown to provide higher resolution and improved image quality parameters over existing approaches. A primary benefit of the method is radiation dose reduction since the invention can produce an image of a desired quality with a fewer number projections than seen with conventional methods.

47 OTHER INSTRUMENTATION↗

Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrieving images from tarnished daguerreotypes using X-ray fluorescence imaging with an X-ray micro beam with tunable energy

We report recent observations using a synchrotron X-ray micro-beam to retrieve images from tarnished 19th century daguerreotypes. We confirm that high quality image can always be retrieved from tarnished plates using Hg L α XRF as long as the bulk of the image particles and their distribution remains intact. We also report results from using tunable tender X-rays (2 - 7 keV) to conduct imaging in high vacuum at energy above the Ag L-edge and the Hg M-edge, extracting images using Ag L α and Hg M α , respectively among others (e.g., S to track corrosion). Images obtained with the surface sensitive total electron yield (TEY) and the bulk sensitive fluorescence yield (FLY) as well as corresponding micro-XANES are reported. Flux tolerance to high intensity X-beam is also explored. These results and their implications for cultural heritage research are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit

Purpose: Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. Methods and Materials: A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210 Degree-Sign of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Results: Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited <0.2 mm peak-to-peak variation. With a 0.5-mm voxel pitch, the maximum targeting error was 0.4 mm. Images of 2 patients were analyzed offline and submillimeter agreement was confirmed with conventional frame. Conclusions: A cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao↗

First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system

The authors report the first magnetic resonance (MR) images produced by their prototype MR system integrated with a radiation therapy source. The prototype consists of a 6 MV linac mounted onto the open end of a biplanar 0.2 T permanent MR system which has 27.9 cm pole-to-pole opening with flat gradients (40 mT/m) running under a TMX NRC console. The distance from the magnet isocenter to the linac target is 80 cm. The authors' design has resolved the mutual interferences between the two devices such that the MR magnetic field does not interfere with the trajectory of the electron in the linac waveguide, and the radiofrequency (RF) signals from each system do not interfere with the operation of the other system. Magnetic and RF shielding calculations were performed and confirmed with appropriate measurements. The prototype is currently on a fixed gantry; however, in the very near future, the linac and MR magnet will rotate in unison such that the linac is always aimed through the opening in the biplanar magnet. MR imaging was found to be fully operational during linac irradiation and proven by imaging a phantom with conventional gradient echo sequences. Except for small changes in SNR, MR images produced during irradiation were visually and quantitatively very similar to those taken with the linac turned off. This prototype system provides proof of concept that the design has decreased the mutual interferences sufficiently to allow the development of real-time MR-guided radiotherapy. Low field-strength systems (0.2-0.5 T) have been used clinically as diagnostic tools. The task of the linac-MR system is, however, to provide MR guidance to the radiotherapy beam. Therefore, the 0.2 T field strength would provide adequate image quality for this purpose and, with the addition of fast imaging techniques, has the potential to provide 4D soft-tissue visualization not presently available in image-guided radiotherapy systems. The authors' initial design incorporates a permanent magnet; however, other types of magnets and field strengths could also be incorporated. Usable MR images were obtained during linac irradiation from the linac-MR prototype. The authors' prototype design can be used as the functional starting point in developing real-time MR guidance offering soft-tissue contrast that can be coupled with tumor tracking for real-time adaptive radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a physical 3D anthropomorphic breast phantom

Purpose: Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. Methods: The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the voxel phantom consisting of the glandular tissue, skin, and Cooper's ligaments is separated into sections. These sections are then fabricated by high-resolution rapid prototyping using a single material with 50% glandular equivalence. The remaining adipose compartments are then filled using an epoxy-based resin (EBR) with 100% adipose equivalence. The phantom sections are stacked to form the physical anthropomorphic phantom. Results: The authors fabricated a prototype phantom corresponding to a 450 ml breast with 45% dense tissue, deformed to a 5 cm compressed thickness. Both the rapid prototype (RP) and EBR phantom materials are radiographically uniform. The coefficient of variation (CoV) of the relative attenuation between RP and EBR phantom samples was <1% and the CoV of the signal intensity within RP and EBR phantom samples was <1.5% on average. Digital mammography and reconstructed digital breast tomosynthesis images of the authors' phantom were reviewed by two radiologists; they reported that the images are similar in appearance to clinical images, noting there are still artifacts from air bubbles in the EBR. Conclusions: The authors have developed a technique to produce 3D anthropomorphic breast phantoms with known ground truth, yielding highly realistic x-ray images. Such phantoms may serve both qualitative and quantitative performance assessments for 2D and 3D breast x-ray imaging systems.

60 APPLIED LIFE SCIENCES↗

Optimizing cone beam CT scatter estimation in egs-cbct for a clinical and virtual chest phantom

Purpose: Cone beam computed tomography (CBCT) image quality suffers from contamination from scattered photons in the projection images. Monte Carlo simulations are a powerful tool to investigate the properties of scattered photons.egs-cbct, a recent EGSnrc user code, provides the ability of performing fast scatter calculations in CBCT projection images. This paper investigates how optimization of user inputs can provide the most efficient scatter calculations. Methods: Two simulation geometries with two different x-ray sources were simulated, while the user input parameters for the efficiency improving techniques (EITs) implemented inegs-cbct were varied. Simulation efficiencies were compared to analog simulations performed without using any EITs. Resulting scatter distributions were confirmed unbiased against the analog simulations. Results: The optimal EIT parameter selection depends on the simulation geometry and x-ray source. Forced detection improved the scatter calculation efficiency by 80%. Delta transport improved calculation efficiency by a further 34%, while particle splitting combined with Russian roulette improved the efficiency by a factor of 45 or more. Combining these variance reduction techniques with a built-in denoising algorithm, efficiency improvements of 4 orders of magnitude were achieved. Conclusions: Using the built-in EITs inegs-cbct can improve scatter calculation efficiencies by more than 4 orders of magnitude. To achieve this, the user must optimize the input parameters to the specific simulation geometry. Realizing the full potential of the denoising algorithm requires keeping the statistical uncertainty below a threshold value above which the efficiency drops exponentially.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-10: A Moving-Blocker-Based Strategy for Simultaneous Megavoltage and Kilovoltage Scatter Correction in Cone-Beam Computed Tomography Image Acquired During Volumetric Modulated Arc Therapy

Purpose: To evaluate a moving-blocker-based approach in estimating and correcting megavoltage (MV) and kilovoltage (kV) scatter contamination in kV cone-beam computed tomography (CBCT) acquired during volumetric modulated arc therapy (VMAT). Methods: XML code was generated to enable concurrent CBCT acquisition and VMAT delivery in Varian TrueBeam developer mode. A physical attenuator (i.e., “blocker”) consisting of equal spaced lead strips (3.2mm strip width and 3.2mm gap in between) was mounted between the x-ray source and patient at a source to blocker distance of 232mm. The blocker was simulated to be moving back and forth along the gantry rotation axis during the CBCT acquisition. Both MV and kV scatter signal were estimated simultaneously from the blocked regions of the imaging panel, and interpolated into the un-blocked regions. Scatter corrected CBCT was then reconstructed from un-blocked projections after scatter subtraction using an iterative image reconstruction algorithm based on constraint optimization. Experimental studies were performed on a Catphan 600 phantom and an anthropomorphic pelvis phantom to demonstrate the feasibility of using moving blocker for MV-kV scatter correction. Results: MV scatter greatly degrades the CBCT image quality by increasing the CT number inaccuracy and decreasing the image contrast, in addition to the shading artifacts caused by kV scatter. The artifacts were substantially reduced in the moving blocker corrected CBCT images in both Catphan and pelvis phantoms. Quantitatively, CT number error in selected regions of interest reduced from 377 in the kV-MV contaminated CBCT image to 38 for the Catphan phantom. Conclusions: The moving-blockerbased strategy can successfully correct MV and kV scatter simultaneously in CBCT projection data acquired with concurrent VMAT delivery. This work was supported in part by a grant from the Cancer Prevention and Research Institute of Texas (RP130109) and a grant from the American Cancer Society (RSG-13-326-01-CCE)

60 APPLIED LIFE SCIENCES↗

SU-E-T-494: A MOSFET-Based In-Vivo Dosimetry System for MR Image-Guided Radiation Therapy (MR-IGRT)

Purpose: To determine if a MOSFET based in-vivo dosimetry system can be used for patients undergoing MR-IGRT. Methods: Standard and high sensitivity MOSFET detectors were used for in-field and out-of-field measurements respectively. The systems were benchmarked and calibrated against a calibrated ionization chamber on a standard 6 MV linear accelerator, and then on the MR-IGRT system. Known doses were delivered to a water phantom with the MOSFETs placed between the top of the phantom and underneath a layer of bolus and water equivalent plastic, using a 6 MV beam and a {sup 6} {sup 0}Co MR-IGRT beam. The latter was performed with and without real-time MRI-guidance during the beam delivery (MRIGRT). Results: The in-field dosimeter response was linear from 50-500 cGy with little evidence of energy dependence or change in response due to the permanent static magnetic field of the MR-IGRT system. The detector response varied by < 2% between 6 MV and {sup 6} {sup 0}Co without image guided delivery. The out-of-field dosimeter response was linear from 1-50 cGy; however the detectors did display dose rate and energy dependence as the response varied by > 20% depending on distance from isocenter used during calibration. Therefore, to use the dosimeters for out-of-field measurements they must be calibrated out-of-field. Regardless of the detector orientation in the coronal plan, the response of the MOSFETs during MRI-guided delivery increased by 5% due to induced currents from the dynamic magnetic field present with image guidance. During the MRI-guided delivery, some loss in image quality was seen when the MOSFETs were present in the imaging plane. This was mitigated by using a handheld reader without a transmitting wireless receiver. Conclusion: A MOSFET-based in-vivo dosimetry system can be used for patients receiving MR-IGRT; however the change in detector response due to the dynamic magnetic field requires a special calibration.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-176: Development of a Patient-Specific 3D Couplant Pad for Ultrasound IGRT

Purpose: to overcome the several issues of ultrasound image-guided radiation therapy (US IGRT) such as probe pressure and optical tracking disability by using a patient-specific three-dimensional couplant pad (CP) fabricated by a patient’s skin mold using a 3D printing technique. Methods: A CP was then fabricated by pouring gelatin solution into a fixed-shape container accommodating the patient skin mold fabricated by a 3D printer. A breast phantom was fabricated with the compound of gelatin and agarose and a phantom study was carried out. From four patients who underwent US IGRT, total 486 ultrasound images with and without a CP were acquired before treatment. Effectiveness of the use of the CP was evaluated. Results: The positioning accuracies in the phantom study were 0.9 ± 0.3 mm and 1.3 ± 0.4 mm with and without the CP in 3D vector amplitude, respectively. In the patient study, the use of CP reduced the mean target shift from 4.7 mm to 3.7 mm in 3D vector amplitude and the one standard deviation from 2.2 mm to 1.7 mm. It also improved the image contrast around the treatment target by 10 %. The centroid offset of the target volume affected from the US scanning coverage and the target deformation due to the excessive probe pressure was decreased from 4.4 mm to 2.9 mm due to the use of CP. Its difference among three different users was statistically significant (p=0.020) without the use of CP but not significantly different (p=0.133) with the use of CP. Conclusion: Our patient-specific 3D CP using a mold by 3D printing technique is a promising strategy for improving tracking accuracy, image quality, and inter-observer variation for ultrasound-based image guided radiotherapy. In addition to its conventional advantage of non-invasiveness, US can be more facilitated in radiotherapy by the developed CP.

60 APPLIED LIFE SCIENCES↗

Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging

We describe an ultrahigh-resolution (UHR) retinal imaging system that combines adaptive optics Fourier-domain optical coherence tomography (AO-OCT) with an adaptive optics scanning laser ophthalmoscope (AO-SLO) to allow simultaneous data acquisition by the two modalities. The AO-SLO subsystem was integrated into the previously described AO-UHR OCT instrument with minimal changes to the latter. This was done in order to ensure optimal performance and image quality of the AO- UHR OCT. In this design both imaging modalities share most of the optical components including a common AO-subsystem and vertical scanner. One of the benefits of combining Fd-OCT with SLO includes automatic co-registration between two acquisition channels for direct comparison between retinal structures imaged by both modalities (e.g., photoreceptor mosaics or microvasculature maps). Because of differences in the detection scheme of the two systems, this dual imaging modality instrument can provide insight into retinal morphology and potentially function, that could not be accessed easily by a single system. In this paper we describe details of the components and parameters of the combined instrument, including incorporation of a novel membrane magnetic deformable mirror with increased stroke and actuator count used as a single wavefront corrector. We also discuss laser safety calculations for this multimodal system. Finally, retinal images acquired in vivo with this system are presented.

59 BASIC BIOLOGICAL SCIENCES↗

Data recording and processing for speckle image reconstruction

Image reconstruction from astronomical speckle data using the Knox-Thompson algorithm has now been extensively demonstrated as feasible through analysis and computer simulations. Experimental verification of the technique and its implementation for astronomy places stringent constraints on the recording system and requires complex processing algorithms to handle the many experimental details. In this paper we describe a video recording system specifically designed for the requirements of speckle imaging. This system has been built and tested, yielding high quality image reconstructions from a laboratory-atmospheric simulator for a wide range of input light levels and test objects.

Nisenson, P.↗