Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image classification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A Review of Machine Learning Classification Using Quantum Annealing for Real-World Applications

Optimizing the training of a machine learning pipeline helps in reducing training costs and improving model performance. One such optimizing strategy is quantum annealing, which is an emerging computing paradigm that has shown potential in optimizing the training of a machine learning model. The implementation of a physical quantum annealer has been realized by D-wave systems and is available to the research community for experiments. Recent experimental results on a variety of machine learning applications using quantum annealing have shown interesting results where the performance of classical machine learning techniques is limited by limited training data and high dimensional features. This article explores the application of D-wave’s quantum annealer for optimizing machine learning pipelines for real-world classification problems. Finally, we review the application domains on which a physical quantum annealer has been used to train machine learning classifiers. We discuss and analyze the experiments performed on the D-Wave quantum annealer for applications such as image recognition, remote sensing imagery, computational biology, and particle physics. We discuss the possible advantages and the problems for which quantum annealing is likely to be advantageous over classical computation.

97 MATHEMATICS AND COMPUTING↗

Automated, high-accuracy classification of textured microstructures using a convolutional neural network

Crystallographic texture is an important descriptor of material properties but requires time-intensive electron backscatter diffraction (EBSD) for identifying grain orientations. While some metrics such as grain size or grain aspect ratio can distinguish textured microstructures from untextured microstructures after significant grain growth, such morphological differences are not always visually observable. This paper explores the use of deep learning to classify experimentally measured textured microstructures without knowledge of crystallographic orientation. A deep convolutional neural network is used to extract high-order morphological features from binary images to distinguish textured microstructures from untextured microstructures. The convolutional neural network results are compared with a statistical Kolmogorov–Smirnov tests with traditional morphological metrics for describing microstructures. Results show that the convolutional neural network achieves a significantly improved classification accuracy, particularly at early stages of grain growth, highlighting the capability of deep learning to identify the subtle morphological patterns resulting from texture. The results demonstrate the potential of a convolutional neural network as a tool for reliable and automated microstructure classification with minimal preprocessing.

36 MATERIALS SCIENCE↗

Deploying Adversarial Attacks in Super-Resolution Models

Reliable super-resolution methods are crucial for applications like remote sensing, grid resilience and disaster impact analysis, and standoff biometrics. These methods infuse additional high-frequency information into reconstructions, allowing for better contextualization and image intelligence. However, super-resolution models can also introduce hallucinations or other unseen vulnerabilities that could be exploited by an adversary. This is further compounded by the prominence of deep learning in these models, as models are often blindly applied on out-of-distribution images. In this work, we implement adversarial attacks in common open-source super-resolution models and examine their impact on reconstructions and downstream classification tasks. We find that an adversarially trained super-resolution model can produce high-quality reconstructions that degrade downstream classifications. Moreover, these attacks do not require access to low-resolution imagery or class labels at inference time. These results demonstrate the vulnerability of super-resolution methods to malicious actors and motivates the development of a detector for super-resolution adversarial attacks. Further exploration of adversarial attacks in this domain is required to ensure trustworthiness and robustness of super-resolution models for national security applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

VLT/SINFONI Observations of Spitzer /MIPSGAL 24 μ m Circumstellar Shells: Revealing the Natures of Their Central Sources

We present Very Large Telescope/Spectrograph for INtegral Field Observations in the Near Infrared H - and K -band spectra of potential central stars within the inner 8″-by-8″ regions of 55 MIPSGAL “bubbles” (MBs), sub-arcminute circumstellar shells discovered in the mid-IR survey of the Galactic plane with Spitzer /MIPS. At magnitudes brighter than 15, we detect a total of 230 stars in the K band and 179 stars in the H band. We spectrally identify 145 stars in all but three MBs, with average magnitudes of 13.8 and 12.7 respectively, using spectral libraries and previous studies of near-IR stellar spectra. We also use tabulated intrinsic stellar magnitudes and colors to derive distances and extinction values, and to better constrain the classifications of the stars. We reliably identify the central sources for 21 of the 55 MBs, which we classify as follows: one Wolf–Rayet, three luminous blue variable candidates, four early-type (O to F), and 15 late-type (G to M) stars. The 21 central sources are, on average, one magnitude fainter than these in the most recent study of MBs, and we notice a significant drop in the fraction of massive star candidates. For the 34 remaining MBs in our sample, we are unable to identify the central sources due to confusion, low spectroscopic signal-to-noise ratio, and/or lack of detections in the images near the centers of the bubbles. We discuss how our findings compare with previous studies and support the trend, for the most part, between the shells’ morphologies in the mid-IR and central sources spectral types.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining Multicolor FISH with Fluorescence Lifetime Imaging for Chromosomal Identification and Chromosomal Sub Structure Investigation

Understanding the structure of chromatin in chromosomes during normal and diseased state of cells is still one of the key challenges in structural biology. Using DAPI staining alone together with Fluorescence lifetime imaging (FLIM), the environment of chromatin in chromosomes can be explored. Fluorescence lifetime can be used to probe the environment of a fluorophore such as energy transfer, pH and viscosity. Multicolor FISH (M-FISH) is a technique that allows individual chromosome identification, classification as well as assessment of the entire genome. Here we describe a combined approach using DAPI as a DNA environment sensor together with FLIM and M-FISH to understand the nanometer structure of all 46 chromosomes in the nucleus covering the entire human genome at the single cell level. Upon DAPI binding to DNA minor groove followed by fluorescence lifetime measurement and imaging by multiphoton excitation, structural differences in the chromosomes can be studied and observed. This manuscript provides a blow by blow account of the protocol required to perform M-FISH-FLIM of whole chromosomes.

59 BASIC BIOLOGICAL SCIENCES↗

TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-02: An MRI Simulator From Proposal to Operation

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

Dynamic Computed Tomography Angiography: Role in the Evaluation of Popliteal Artery Entrapment Syndrome

This study reviews our experience with dynamic computed tomographic angiography (CTA) as an imaging modality in the evaluation of popliteal artery entrapment syndrome (PAES). Eight patients with surgically proven PAES were included in this study. Dynamic CTA studies performed with the feet in neutral and plantar flexed positions were reviewed for the detailed anatomy of the region and to define the location and extent of the stenosis, occlusions and collateral circulation. These findings were compared with intraoperative observations. CTA provided adequate angiographic and anatomic information required to arrive at the diagnosis and make a surgical decision. Thirteen limbs were affected in eight patients. There was popliteal artery occlusion in four limbs, stenosis at rest that was accentuated on stress imaging in two limbs, and patent popliteal artery with marked stenosis on stress imaging in seven limbs. Long-segment stenosis was seen in functional entrapment compared to short-segment stenosis in anatomic PAES. Anteroposterior compression of the popliteal artery in anatomic PAES unlike the side-to-side compression in functional PAES was a unique observation in this study. The CTA and surgical characterisation and classification of PAES matched in all the patients, except for misinterpretation of compressing fibrous bands as accessory slips of muscles in three limbs. In conclusion, dynamic CTA is a robust diagnostic tool that provides clinically relevant information and serves as a rapidly performed and easily available 'one-stop-shop' imaging modality in the management of PAES.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

POPULATION PROPERTIES OF BROWN DWARF ANALOGS TO EXOPLANETS

We present a kinematic analysis of 152 low surface gravity M7-L8 dwarfs by adding 18 new parallaxes (including 10 for comparative field objects), 38 new radial velocities, and 19 new proper motions. We also add low- or moderate-resolution near-infrared spectra for 43 sources confirming their low surface gravity features. Among the full sample, we find 39 objects to be high-likelihood or new bona fide members of nearby moving groups, 92 objects to be ambiguous members and 21 objects that are non-members. Using this age-calibrated sample, we investigate trends in gravity classification, photometric color, absolute magnitude, color–magnitude, luminosity, and effective temperature. We find that gravity classification and photometric color clearly separate 5–130 Myr sources from >3 Gyr field objects, but they do not correlate one to one with the narrower 5–130 Myr age range. Sources with the same spectral subtype in the same group have systematically redder colors, but they are distributed between 1 and 4 σ from the field sequences and the most extreme outlier switches between intermediate- and low-gravity sources either confirmed in a group or not. The absolute magnitudes of low-gravity sources from the J band through W 3 show a flux redistribution when compared to equivalently typed field brown dwarfs that is correlated with spectral subtype. Low-gravity, late-type L dwarfs are fainter at J than the field sequence but brighter by W 3. Low-gravity M dwarfs are >1 mag brighter than field dwarfs in all bands from J through W 3. Clouds, which are a far more dominant opacity source for L dwarfs, are the likely cause. On color–magnitude diagrams, the latest-type, low-gravity L dwarfs drive the elbow of the L/T transition up to 1 mag redder and 1 mag fainter than field dwarfs at M{sub J} but are consistent with or brighter than the elbow at M{sub W1} and M{sub W2}. We conclude that low-gravity dwarfs carry an extreme version of the cloud conditions of field objects to lower temperatures, which logically extends into the lowest-mass, directly imaged exoplanets. Furthermore, there is an indication on color-magnitude diagrams (CMDs; such as M{sub J} versus (J – W 2)) of increasingly redder sequences separated by gravity classification, although it is not consistent across all CMD combinations. Examining bolometric luminosities for planets and low-gravity objects, we confirm that (in general) young M dwarfs are overluminous while young L dwarfs are normal compared to the field. Using model extracted radii, this translates into normal to slightly warmer M dwarf temperatures compared to the field sequence and lower temperatures for L dwarfs with no obvious correlation with the assigned moving group.

79 ASTRONOMY AND ASTROPHYSICS↗

A machine learning pipeline for identifying infiltration managed aquifer recharge locations from satellite imagery in the San Joaquin Valley, California

This study focuses on an agricultural region in California’s Central Valley, USA, where Managed Aquifer Recharge (MAR) is widely implemented to mitigate groundwater depletion under increasing water demand and climate variability. A deep learning and machine learning framework was developed to identify infiltration-MAR locations using satellite imagery and environmental data. The framework integrates surface water detection from Sentinel-2 imagery, geospatial delineation of water bodies, spatiotemporal tracking of water body dynamics, and supervised classification using meteorological, environmental, and topographic variables. The framework was applied to a 2379 km² study area southwest of Fresno, where 765 water bodies were detected, including 139 identified MAR sites based on publicly available datasets and expert knowledge. The classification model achieved an accuracy of 0.94 and an F1 score of 0.85. Feature importance analysis indicates that cropland, normalized difference vegetation index (NDVI), and evaporation are among the most influential predictors for infiltration-MAR. Notably, the framework suggests that engineered water management in infiltration-MAR systems can disrupt or even reverse the expected positive correlation between surface water extent and precipitation. These findings provide physically interpretable insights into the characteristics of existing infiltration-MAR facilities and demonstrate the potential of the proposed framework as a reproducible, interpretable, and potentially transferable tool for data-driven infiltration-MAR identification and inventory development under growing climatic and hydrological uncertainty.

Classification↗

Exploring End-to-end Deep Learning Applications for Event Classification at CMS

An essential part of new physics searches at the Large Hadron Collider (LHC) at CERN involves event classification, or distinguishing potential signal events from those coming from background processes. Current machine learning techniques accomplish this using traditional hand-engineered features like particle 4-momenta, motivated by our understanding of particle decay phenomenology. While such techniques have proven useful for simple decays, they are highly dependent on our ability to model all aspects of the phenomenology and detector response. Meanwhile, powerful deep learning algorithms are capable of not only training on high-level features, but of performing feature extraction. In computer vision, convolutional neural networks have become the state-of-the-art for many applications. Motivated by their success, we apply deep learning algorithms to low-level detector data from the 2012 CMS Simulated Open Data to directly learn useful features, in what we call, end-to-end event classification. We demonstrate the power of this approach in the context of a physics search and offer solutions to some of the inherent challenges, such as image construction, image sparsity, combining multiple sub-detectors, and de-correlating the classifier from the search observable, among others.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis and Mapping of Vegetation and Habitat for the Hart Mountain National Antelope Refuge

The Lakeview, Oregon, office of the U.S. Fish and Wildlife Service (USFWS) contracted Pacific Northwest National Laboratory to classify vegetation communities on Hart Mountain National Antelope Refuge in northeastern Nevada. The objective of the mapping project was to provide USFWS refuge biologists and planners with detailed vegetation and habitat information that can be referenced to make better decisions regarding wildlife resources, fuels and fire risk, and land management. This letter report describes the datasets and methods used to develop vegetation cover type and shrub canopy cover maps for the Hart Mountain National Antelope Refuge. The two map products described in this report are 1) a vegetation cover classification that provides updated information on the vegetation associations occurring on the refuge and 2) a map of shrub canopy cover based on high-resolution images and field data.

54 ENVIRONMENTAL SCIENCES↗

Vertebral Body Growth After Craniospinal Irradiation

Purpose: To estimate the effects of radiotherapy and clinical factors on vertebral growth in patients with medulloblastoma and supratentorial primitive neuroectodermal tumors treated with craniospinal irradiation (CSI) and chemotherapy. Methods and Materials: The height of eight individual or grouped vertebral bodies (C3, C3-C4, T4, T4-T5, C6-T3, T4-T7, L3, L1-L5) was measured before and after CSI (23.4 or 36-39.6 Gy) in 61 patients. Of the 61 patients, 40 were boys and 21 were girls (median age, 7 years; range, 3-13 years), treated between October 1996 and October 2003. Sagittal T{sub 1}-weighted magnetic resonance images were used for the craniocaudal measurements. The measurements numbered 275 (median, 5/patient; range, 3-7). The median follow-up after CSI was 44.1 months (range, 13.8-74.9 months). Results: Significant growth was observed in all measured vertebrae. Excluding C3-C4, the growth rate of the grouped vertebrae was affected by age, gender, and CSI dose (risk classification). The risk classification alone affected the growth rates of C3 (p = 0.002) and L3 (p = 0.02). Before CSI, the length of all vertebral bodies was an increasing function of age (p <0.0001). The C3 length before CSI was affected by gender and risk classification: C3 was longer for female (p = 0.07) and high-risk (p = 0.07) patients. Conclusion: All vertebrae grew significantly after CSI, with the vertebrae of the boys and younger patients growing at a rate greater than that of their counterparts. The effect of age was similar across all vertebrae, and gender had the greatest effect on the growth of the lower cervical and upper thoracic vertebrae. The effect of the risk classification was greatest in the lumbar spine by a factor of {<=}10.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital twins and deep learning segmentation of defects in monolayer MX 2 phases

Developing methods to understand and control defect formation in nanomaterials offers a promising route for materials discovery. Monolayer MX 2 phases represent a particularly compelling case for defect engineering of nanomaterials due to the large variability in their physical properties as different defects are introduced into their structure. However, effective identification and quantification of defects remain a challenge even as high-throughput scanning transmission electron microscopy methods improve. This study highlights the benefits of employing first principles calculations to produce digital twins for training deep learning segmentation models for defect identification in monolayer MX 2 phases. Around 600 defect structures were obtained using density functional theory calculations, with each monolayer MX 2 structure being subjected to multislice simulations for the purpose of generating the digital twins. Several deep learning segmentation architectures were trained on this dataset, and their performances evaluated under a variety of conditions such as recognizing defects in the presence of unidentified impurities, beam damage, grain boundaries, and with reduced image quality from low electron doses. Further, this digital twin approach allows benchmarking different deep learning architectures on a theory dataset, which enables the study of defect classification under a broad array of finely controlled conditions. It thus opens the door to resolving the underpinning physical reasons for model shortcomings and potentially chart paths forward for automated discovery of materials defect phases in experiments.

36 MATERIALS SCIENCE↗

High-Resolution, Non-Invasive Imaging of Upper Vocal Tract Articulators Compatible with Human Brain Recordings

A complete neurobiological understanding of speech motor control requires determination of the relationship between simultaneously recorded neural activity and the kinematics of the lips, jaw, tongue, and larynx. Many speech articulators are internal to the vocal tract, and therefore simultaneously tracking the kinematics of all articulators is nontrivial-especially in the context of human electrophysiology recordings. Here, we describe a noninvasive, multi-modal imaging system to monitor vocal tract kinematics, demonstrate this system in six speakers during production of nine American English vowels, and provide new analysis of such data. Classification and regression analysis revealed considerable variability in the articulator-to-acoustic relationship across speakers. Non-negative matrix factorization extracted basis sets capturing vocal tract shapes allowing for higher vowel classification accuracy than traditional methods. Statistical speech synthesis generated speech from vocal tract measurements, and we demonstrate perceptual identification. We demonstrate the capacity to predict lip kinematics from ventral sensorimotor cortical activity. These results demonstrate a multi-modal system to non-invasively monitor articulator kinematics during speech production, describe novel analytic methods for relating kinematic data to speech acoustics, and provide the first decoding of speech kinematics from electrocorticography. These advances will be critical for understanding the cortical basis of speech production and the creation of vocal prosthetics.

60 APPLIED LIFE SCIENCES↗