Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Existing Whole-House Solutions Case Study: Deep Energy Retrofit of 1910 House, Portland, Oregon

This case study lists project information, cost and energy efficiency performance data, energy efficiency measures and lessons learned for a 100-year-old home in Portland, Oregon, audited by Pacific Northwest National Laboratory for a deep energy retrofit. New HVAC and extensive insulation upgrades including rigid XPS and new siding over the old lead painted siding, and EPS on the basement walls and in cathedral ceiling helped bring HERS down to 68.

basement↗

Vibroacoustic Response of Residential Housing due to Sonic Boom Exposure: A Summary of two Field Tests

Two experiments have been performed to measure the vibroacoustic response of houses exposed to sonic booms. In 2006, an old home in the base housing area of Edwards Air Force Base, built around 1960 and demolished in 2007, was instrumented with 288 transducers. During a 2007 follow-on test, a newer home in the base housing area, built in 1997, was instrumented with 112 transducers. For each experiment, accelerometers were placed on walls, windows and ceilings in bedrooms of the house to measure the vibration response of the structure. Microphones were placed outside and inside the house to measure the excitation field and resulting interior sound field. The vibroacoustic response of each house was measured for sonic boom amplitudes spanning from 2.4 to 96 Pa (0.05 to 2 lbf/sq ft). The boom amplitudes were systematically varied using a unique dive maneuver of an F/A-18 airplane. In total, the database for both houses contains vibroacoustic response data for 154 sonic booms. In addition, several tests were performed with mechanical shaker excitation of the structure to characterize the forced response of the houses. The purpose of this paper is to summarize all the data from these experiments that are available to the research community, and to compare and contrast the vibroacoustic behavior of these two dissimilar houses.

Klos, Jacob↗

Mobile Thread Task Manager

The Mobile Thread Task Manager (MTTM) is being applied to parallelizing existing flight software to understand the benefits and to develop new techniques and architectural concepts for adapting software to multicore architectures. It allocates and load-balances tasks for a group of threads that migrate across processors to improve cache performance. In order to balance-load across threads, the MTTM augments a basic map-reduce strategy to draw jobs from a global queue. In a multicore processor, memory may be "homed" to the cache of a specific processor and must be accessed from that processor. The MTTB architecture wraps access to data with thread management to move threads to the home processor for that data so that the computation follows the data in an attempt to avoid L2 cache misses. Cache homing is also handled by a memory manager that translates identifiers to processor IDs where the data will be homed (according to rules defined by the user). The user can also specify the number of threads and processors separately, which is important for tuning performance for different patterns of computation and memory access. MTTM efficiently processes tasks in parallel on a multiprocessor computer. It also provides an interface to make it easier to adapt existing software to a multiprocessor environment.

Clement, Bradley J.↗

Backup Power Performance of Solar-plus-Storage Systems during Routine Power Interruptions: A Case Study Application of Berkeley Lab’s PRESTO Model

This technical brief estimates the expected performance of a solar photovoltaic and energy storage system (PVESS) for providing backup power during short-duration power interruption events, accounting for the unpredictable nature of those events. The analysis relies on the Power Reliability Event Simulation TOol (PRESTO), a publicly available model developed by Berkeley Lab to simulate the occurrence of short-duration power interruption events at the county-level. A separate storage dispatch model is then used to simulate PVESS operation and backup performance for each of the large number of interruption events produced by PRESTO. In performing this simulation, the analysis accounts for how the customer operates its battery on a day-to-day basis—in this case, we assume the battery is cycled each day in response to time-of-use rates—and how that, in turn, impacts the battery’s state of charge at the beginning of each interruption event. The analysis presented here is intended to demonstrate an application of the PRESTO model as well as to illustrate some of the key determinants of PVESS backup power performance during short-duration power interruption events. The analysis focuses initially on a typical single-family home in Maricopa County, Arizona, and includes a limited set of scenarios related to system sizing, backup power configuration, and whether the customer charges its battery storage system from the grid during normal operating conditions. The analysis also presents comparative results for two other counties, in Massachusetts (Middlesex) and California (Los Angeles), illustrating how regional differences in climate, interruption patterns, and retail rate structures can affect PVESS performance as a backup power source. In the conclusions, we highlight a number of other important considerations for evaluating PVESS backup power capabilities.

14 SOLAR ENERGY↗

Cigarettes vs. e-cigarettes: Passive exposure at home measured by means of airborne marker and biomarkers

Background: There is scarce evidence about passive exposure to the vapour released or exhaled from electronic cigarettes (e-cigarettes) under real conditions. The aim of this study is to characterise passive exposure to nicotine from e-cigarettes' vapour and conventional cigarettes' smoke at home among non-smokers under real-use conditions. Methods: We conducted an observational study with 54 non-smoker volunteers from different homes: 25 living at home with conventional smokers, 5 living with nicotine e-cigarette users, and 24 from control homes (not using conventional cigarettes neither e-cigarettes). We measured airborne nicotine at home and biomarkers (cotinine in saliva and urine). We calculated geometric mean (GM) and geometric standard deviations (GSD). We also performed ANOVA and Student's t tests for the log-transformed data. We used Bonferroni-corrected t-tests to control the family error rate for multiple comparisons at 5%. Results: The GMs of airborne nicotine were 0.74 μg/m{sup 3} (GSD=4.05) in the smokers’ homes, 0.13 μg/m{sup 3} (GSD=2.4) in the e-cigarettes users’ homes, and 0.02 μg/m{sup 3} (GSD=3.51) in the control homes. The GMs of salivary cotinine were 0.38 ng/ml (GSD=2.34) in the smokers’ homes, 0.19 ng/ml (GSD=2.17) in the e-cigarettes users’ homes, and 0.07 ng/ml (GSD=1.79) in the control homes. Salivary cotinine concentrations of the non-smokers exposed to e-cigarette's vapour at home (all exposed ≥2 h/day) were statistically significant different that those found in non-smokers exposed to second-hand smoke ≥2 h/day and in non-smokers from control homes. Conclusions: The airborne markers were statistically higher in conventional cigarette homes than in e-cigarettes homes (5.7 times higher). However, concentrations of both biomarkers among non-smokers exposed to conventional cigarettes and e-cigarettes’ vapour were statistically similar (only 2 and 1.4 times higher, respectively). The levels of airborne nicotine and cotinine concentrations in the homes with e-cigarette users were higher than control homes (differences statistically significant). Our results show that non-smokers passively exposed to e-cigarettes absorb nicotine. - Highlights: • This is the first study of e-cigarette exposure at home under real-use conditions. • Airborne nicotine in homes with smokers were 5.7 times higher than in e-cig homes. • Cotinine of non-smokers exposed to e-cig and conventional cigarettes was similar. • Airborne nicotine in homes with e-cig users was higher than control homes. • Cotinine of non-smokers exposed to e-cig users was higher than in those no exposed.

54 ENVIRONMENTAL SCIENCES↗

Development of microcomputer-based mental acuity tests

Recent disasters have focused attention on performance problems due to the use of alcohol and controlled substances in the workplace. Environmental stressors such as thermal extremes, mixed gases, noise, motion, and vibration also have adverse effects on human performance and operator efficiency. However, the lack of a standardized, sensitive, human performance assessment battery has probably delayed the systematic study of the deleterious effects of various toxic chemicals and drugs at home and in the workplace. The collective goal of the research reported here is the development of a menu of tests embedded in a coherent package of hardware and software that may be useful in repeated-measures studies of a broad range of agents that can degrade human performance. A menu of 40 tests from the Automated Performance Test System (APTS) is described, and the series of interlocking studies supporting its development is reviewed. The APTS tests, which run on several versions of laptop portables and desktop personal computers, have been shown to be stable, reliable, and factorially rich, and to have predictive validities with holistic measures of intelligence and simulator performances. In addition, sensitivity studies have been conducted in which performance changes due to stressors, agents, and treatments were demonstrated. We believe that tests like those described here have prospective use as an adjunct to urine testing for the screening for performance loss of individuals who are granted access to workplaces and stations that impact public safety.

Non-NASA Center↗

Compositionally Graded Alloy Quantum Dot Phosphors for Solid State Lighting. Final Report

To push the boundaries of efficiency and cost in solid state lighting (SSL), narrow band red emitting down conversion phosphors must be improved. These materials are critical to both the color rendering ability and optical output of phosphor converted light emitting diodes (LEDs). Improvements in these performance parameters will have a significant impact on the adoption of SSL in retail, office, and home lighting applications. Quantum Dots (QDs) are widely acknowledged as a cost-effective front-runner among developing downconverting technologies because they emit narrow band luminescence that is tunable across the visible spectrum. Current syntheses of quantum dots, however, utilize expensive and toxic reagents and often involve several time-intensive purification steps. To address this, we have introduced a novel, cost-effective synthetic scheme, whereby the final quantum dot structures can be accessed with fewer synthetic steps using a library of inexpensive, easily-synthesized precursors. With the help of automated high throughput synthesis robotics, Columbia, LBNL, and OSRAM have optimized red and amber CdS/CdSe/CdS QD architectures for SSL. QDs with improved shelling layers have been identified that meet the industry state of the art performance on chip under high humidity accelerated aging tests. This is remarkable considering the time frame of this project compared to the time and resources allocated for the development of the industrial standard. Furthermore, although particle stability to optical charging is often stressed in improving QLED performance, we have identified effective ZnS particle over-coating as the most important factor determining particle survivability and device performance in down-converting LEDs.

36 MATERIALS SCIENCE↗

Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit

LBNL Residential Diagnostics Database (ResDB) contains blower door measurements and other diagnostic test results of homes in United States. Of these, approximately 134,000 single-family detached homes have sufficient information for the analysis of air leakage in relation to a number of housing characteristics. We performed regression analysis to consider the correlation between normalized leakage and a number of explanatory variables: IECC climate zone, floor area, height, year built, foundation type, duct location, and other characteristics. The regression model explains 68% of the observed variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements of approximately 23,000 homes that participated in weatherization assistant programs (WAPs) or residential energy efficiency programs. The two types of programs achieve rather similar reductions in normalized leakage: 30% for WAPs and 20% for other energy programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Collecting data in the home laboratory: evolution of X-ray sources, detectors and working practices

Recent developments in X-ray crystallographic hardware related to structural biology research are presented and discussed. While the majority of macromolecular X-ray data are currently collected using highly efficient beamlines at an ever-increasing number of synchrotrons, there is still a need for high-performance reliable systems for in-house experiments. In addition to crystal screening and optimization of data-collection parameters before a synchrotron trip, the home system allows the collection of data as soon as the crystals are produced to obtain the solution of novel structures, especially by the molecular-replacement method, and is invaluable in achieving the quick turnover that is often required for ligand-binding studies in the pharmaceutical industry. There has been a continuous evolution of X-ray sources, detectors and software developed for in-house use in recent years and a diverse range of tools for structural biology laboratories are available. An overview of the main directions of these developments and examples of specific solutions available to the macromolecular crystallography community are presented in this paper, showing that data collection ‘at home’ is still an attractive proposition complementing the use of synchrotron beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field Monitoring Protocol: Mini-Split Heat Pumps

The report provides a detailed method for accurately measuring and monitoring performance of a residential Mini-Split Heat Pump. It will be used in high-performance retrofit applications, and as part of DOE's Building America residential research program.

17 WIND ENERGY↗

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bay Ridge Gardens – Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit: Annapolis, Maryland - Building America Case Study: Whole-House Solutions for Existing Homes [Fact Sheet]

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subjective Response to Simulated Sonic Booms in Homes

One of the environmental issues affecting the development of a second-generation supersonic commercial transport is the impact of sonic booms on people. Aircraft designers are attempting to design the transport to produce sonic boom signatures that will have minimum impact on the public. Current supersonic commercial aircraft produce an 'N-wave' sonic boom pressure signature that is considered unacceptable by the public. This has resulted in first-generation supersonic transports being banned from flying supersonic over land in the United States, a severe economic constraint. By tailoring aircraft volume and lift distributions, designers hope to produce sonic boom signatures having specific shapes other than 'N-wave' that may be more acceptable to the public. As part of the effort to develop a second-generation supersonic commercial transport, Langley Research Center is conducting research to study people's subjective response to sonic booms. As part of that research, a system was developed for performing studies of the subjective response of people to the occurrence of simulated sonic booms in their homes. The In-Home Noise Generation/Response System (IHONORS) provides a degree of situational realism not available in the laboratory and a degree of control over the noise exposure not found in community surveys. The computer-controlled audio system generates the simulated sonic booms, measures the noise levels, and records the subjects' ratings and can be placed and operated in individual homes for extended periods of time. The system was used to conduct an in-home study of subjective response to simulated sonic booms. The primary objective of the study was to determine the effect on annoyance of the number of sonic boom occurrences in a realistic environment. The effects on annoyance of several other parameters were also examined. Initially, data analyses were based on all the data collected. However, further analyser found that test subjects adapted to the sonic booms during the first few days of exposure. The first eight days of each testing period consisted of eight introductory exposures that were repeated on randomly selected days later in the testing period. Comparison of the introductory exposures with their repeats indicated that the test subjects adapted to the new sonic boom noise environment during the first days of the testing period. Because of the adaptation occurring, the introductory days were deleted from the ds set and the analyses redone. This paper presents the updated analyses. Elimination of the introductory days did not significantly affect the results and conclusions of the initial analyses. This paper also presents analyses of the effects on annoyance of additional factors in the study not previously examined.

McCurdy, David A.↗

Habitability and Human Factors Assessment (iSHORT, SHAQ, and SHU)

BACKGROUND As long-duration off-planet habitats become a reality, a consideration of habitability and human factors (HF) is crucial. The habitat is more than just a place to live and work. It is also the crew’s perception of the space, and the psychological impacts of size, layout, and usage over time; all of which can support or strain behavioral health and performance (BHP). A previous International Space Station (ISS) habitability study used the iSHORT (Space Habitability Observation Reporting Tool) to collect detailed data about habitability and human factors and inform NASA Standards. Of the previous iSHORT study, only one of the six ISS subjects had a duration of one year; all other ISS and ground analog subjects had shorter mission durations from one week to six months. It is necessary to collect new data with a focus on long-duration exploration missions of > 6 months and on planetary surface habitat design. New data is also needed to compare the iSHORT to other habitability measures. One measure, the SHAQ (Subjective Habitability and Acceptability Questionnaire), assesses the intersection of psychology and habitability. Another complementary measure, the Scale for Habitat Usability (SHU), is a brief subjective scale that captures how habitat design impacts perceived usability of the built environment in relation to task performance. OBJECTIVE Our study aims to (1) understand how individual well-being and team dynamics may relate to HF concerns over time, (2) capture how habitability and HF change over time, (3) compare the three habitability measures (iSHORT, SHAQ, SHU), (4) assess habitats to capture HF design concerns and related BHP impacts of a planetary habitat, and (5) inform future standards for HF design. METHOD Data are being collected on crews living and working in long-duration spaceflight analogs. Individual-level data collections are repeated at regular intervals throughout the missions on several habitat areas, activities, and key equipment (i.e., points of interest). These points of interest (POIs) include the kitchen/galley, crew quarters, and other work and living areas. Assessments include evaluations of privacy, comfort, convenience, control, efficiency, and social density through the lens of subsequent outcomes like sleep, individual performance, group activities performance, stress, mood, and social interactions. Pre- and post-mission evaluations will also allow comparison with homes, pre- and post-mission hotels, and a retrospective reflection of living and working in a long-duration analog. INITIAL DATA COLLECTIONS In this poster, we will describe the measures and data yield. Since the research protocol was designed, the study team has collected iSHORT Standalone four times, nine collections of SHAQ, and three collections of iSHORT with SHAQ. Data collection is ongoing. SUMMARY A novel assessment suite has been developed to further aid the comparison and complementary understanding of the habitability and human factors measures, which will allow for efficient deployment of these measures in analogs and/or spaceflight in near-term research as well as support well-being and performance through design.

J C W Miller↗