Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A Versatile High-Resolution X-Ray Imager (HRXI) for Laser-Plasma Experiments on OMEGA

A high-resolution x-ray imager (HRXI) devoted to laser-plasma experiments combines two state-of-the-art technologies developed in France: a high-resolution x-ray microscope and a high-speed x-ray streak camera. The resulting streaked imager achieves spatial and temporal resolutions of ~5 um and ~10 ps, respectively. The HXRI has recorded enhanced spatial and temporal resolution radiographs of indirectly driven targets on OMEGA. This paper describes the main features of the instrument and details the activation process on OMEGA (particularly the alignment). Recent results obtained on joint CEA/LLE radiographic OMEGA experiments will also be presented.

Bourgade, J L↗

Solar Wind Charge Exchange Studies Of Highly Charged Ions On Atomic Hydrogen

Accurate studies of low-energy charge exchange (CX) are critical to understanding underlying soft X-ray radiation processes in the interaction of highly charged ions from the solar wind with the neutral atoms and molecules in the heliosphere, cometary comas, planetary atmospheres, interstellar winds, etc.. Particularly important are the CX cross sections for bare, H-like, and He-like ions of C, N, O and Ne, which are the dominant charge states for these heavier elements in the solar wind. Absolute total cross sections for single electron capture by H-like ions of C, N, O and fully-stripped O ions from atomic hydrogen have been measured in an expanded range of relative collision energies (5 eV/u-20 keV/u) and compared to previous H-oven measurements. The present measurements are performed using a merged-beams technique with intense highly charged ion beams extracted from a 14.5 GHz ECR ion source installed on a high voltage platform at the Oak Ridge National Laboratory. For the collision energy range of 0.3 keV/u-3.3 keV/u, which corresponds to typical ion velocities in the solar wind, the new measurements are in good agreement with previous H-oven measurements. The experimental results are discussed in detail and compared with theoretical calculations where available.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-order harmonics from bow wave caustics driven by a high-intensity laser

We propose a new mechanism of high-order harmonic generation during an interaction of a high-intensity laser pulse with underdense plasma. A tightly focused laser pulse creates a cavity in plasma pushing electrons aside and exciting the wake wave and the bow wave. At the joint of the cavity wall and the bow wave boundary, an annular spike of electron density is formed. This spike surrounds the cavity and moves together with the laser pulse. Collective motion of electrons in the spike driven by the laser field generates high-order harmonics. A strong localization of the electron spike, its robustness to oscillations imposed by the laser field and, consequently, its ability to produce high-order harmonics is explained by catastrophe theory. The proposed mechanism explains the experimental observations of high-order harmonics with the 9 TW J-KAREN laser (JAEA, Japan) and the 120 TW Astra Gemini laser (CLF RAL, UK) [A. S. Pirozhkov, et al., arXiv:1004.4514 (2010); A. S. Pirozhkov et al, AIP Proceedings, this volume]. The theory is corroborated by high-resolution two-and three-dimensional particle-in-cell simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high-resolution multi-slit phase space measurement technique for low-emittance beams

Precise measurement of transverse phase space of a high-brightness electron beamis of fundamental importance in modern accelerators and free-electron lasers. Often, the transverse phase space of a high-brightness, space-charge-dominated electron beam is measured using a multi-slit method. In this method, a transverse mask (slit/pepperpot) samples the beaminto a set of beamlets, which are then analyzed on to a screen downstream. The resolution in this method is limited by the type of screen used which is typically around 20 {mu}m for a high-sensitivity Yttrium Aluminum Garnet screen. Accurate measurement of sub-micron transverse emittance using this method would require a long drift space between the multi-slit mask and observation screen. In this paper, we explore a variation of the technique that incorporates quadrupole magnets between the multi-slit mask and the screen. It is shown that this arrangement can improve the resolution of the transverse-phase-space measurement with in a short footprint.

43 PARTICLE ACCELERATORS↗

High precision measurement of the proton charge radius: The PRad experiment

The recent high precision measurements of the proton charge radius performed at PSI from muonic hydrogen Lamb shift puzzled the hadronic physics community. A value of 0.8418 ± 0.0007 fm was extracted which is 7σ smaller than the previous determinations obtained from electron-proton scattering experiments and based on precision spectroscopy of electronic hydrogen. An additional extraction of the proton charge radius from electron scattering at Mainz is also in good agreement with these 'electronic' determinations. An independent measurement of the proton charge radius from unpolarized elastic ep scattering using a magnetic spectrometer free method was proposed and fully approved at Jefferson Laboratory in June 2012. This novel technique uses the high precision calorimeter HyCal and a windowless hydrogen gas target which makes possible the extraction of the charge radius at very forward angles and thus very low momentum transfer Q{sup 2} up to 10{sup −4} (GeV/c){sup 2} with an unprecedented sub-percent precision for this type of experiment. In this paper, after a review of the recent progress on the proton charge radius extraction and the new high precision experiment PRad will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact high-performance low-field NMR apparatus for measurements on fluids at very high pressures and temperatures

We discuss an innovative new high-performance apparatus for performing low-field Nuclear Magnetic Resonance (NMR) relaxation times and diffusion measurements on fluids at very high pressures and high temperatures. The apparatus sensor design and electronics specifications allow for dual deployment either in a fluid sampling well logging tool or in a laboratory. The sensor and electronics were designed to function in both environments. This paper discusses the use of the apparatus in a laboratory environment. The operating temperature and pressure limits, and the signal-to-noise ratio (SNR) of the new system exceed by a very wide margin what is currently possible. This major breakthrough was made possible by a revolutionary new sensor design that breaks many of the rules of conventional high pressure NMR sensor design. A metallic sample holder capable of operating at high pressures and temperatures is provided to contain the fluid under study. The sample holder has been successfully tested for operation up to 36 Kpsi. A solenoid coil wound on a slotted titanium frame sits inside the metallic sample holder and serves as an antenna to transmit RF pulses and receive NMR signals. The metal sample holder is sandwiched between a pair of gradient coils which provide a linear field gradient for pulsed field gradient diffusion measurements. The assembly sits in the bore of a low-gradient permanent magnet. The system can operate over a wide frequency range without the need for tuning the antenna to the Larmor frequency. The SNR measured on a water sample at room temperature is more than 15 times greater than that of the commercial low-field system in our laboratory. Thus, the new system provides for data acquisition more than 200 times faster than was previously possible. Laboratory NMR measurements of relaxations times and diffusion coefficients performed at pressures up to 25 Kpsi and at temperatures up to 175 °C with crude oils enlivened with dissolved hydrocarbon gases (referred to as “live oils”) are shown. This is the first time low-field NMR measurements have been performed at such high temperatures and pressures on live crude oil samples. We discuss the details of the apparatus design, tuning, calibration, and operation. NMR data acquired at multiple temperatures and pressures on a live oil sample are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended-range grazing-incidence spectrometer for high-resolution extreme ultraviolet measurements on an electron beam ion trap

A high-resolution grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for performing very high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 Å to above 300 Å. The instrument operates without an entrance slit and focuses the light emitted by highly charged ions located in the roughly 50 μm wide electron beam onto a cryogenically cooled back-illuminated charge-coupled device detector. The measured line widths are below 0.025 Å above 100 Å, and the resolving power appears to be limited by the source size and Doppler broadening of the trapped ions. Comparisons with spectra obtained with existing grating spectrometers show an order of magnitude improvement in spectral resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A rotational and axial motion system load frame insert for in situ high energy x-ray studies

High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new apparatus design for high temperature (up to 950 °C) quasi-elastic neutron scattering in a controlled gaseous environment

A design for a sample cell system suitable for high temperature Quasi-Elastic Neutron Scattering (QENS) experiments is presented. The apparatus was developed at the Spallation Neutron Source in Oak Ridge National Lab where it is currently in use. The design provides a special sample cell environment under controlled humid or dry gas flow over a wide range of temperature up to 950 °C. Using such a cell, chemical, dynamical, and physical changes can be studied in situ under various operating conditions. While the cell combined with portable automated gas environment system is especially useful for in situ studies of microscopic dynamics under operational conditions that are similar to those of solid oxide fuel cells, it can additionally be used to study a wide variety of materials, such as high temperature proton conductors. The cell can also be used in many different neutron experiments when a suitable sample holder material is selected. The sample cell system has recently been used to reveal fast dynamic processes in quasi-elastic neutron scattering experiments, which standard probes (such as electrochemical impedance spectroscopy) could not detect. In this work, we outline the design of the sample cell system and present results demonstrating its abilities in high temperature QENS experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high vacuum compatible optical chopper system for synchrotron x-ray scanning tunneling microscopy

High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrostatic levitation facility optimized for neutron diffraction studies of high temperature liquids at a spallation neutron source

Neutron diffraction studies of metallic liquids provide valuable information about inherent topological and chemical ordering on multiple length scales as well as insight into dynamical processes at the level of a few atoms. However, there exist very few facilities in the world that allow such studies to be made of reactive metallic liquids in a containerless environment, and these are designed for use at reactor-based neutron sources. We present an electrostatic levitation facility, NESL (for Neutron ElectroStatic Levitator), which takes advantage of the enhanced capabilities and increased neutron flux available at spallation neutron sources (SNSs). NESL enables high quality elastic and inelastic neutron scattering experiments to be made of reactive metallic and other liquids in the equilibrium and supercooled temperature regime. The apparatus is comprised of a high vacuum chamber, external and internal neutron collimation optics, and a sample exchange mechanism that allows up to 30 samples to be processed between chamber openings. Two heating lasers allow excellent sample temperature homogeneity, even for samples approaching 500 mg, and an automated temperature control system allows isothermal measurements to be conducted for times approaching 2 h in the liquid state, with variations in the average sample temperature of less than 0.5%. To demonstrate the capabilities of the facility for elastic scattering studies of liquids, a high quality total structure factor for Zr{sub 64}Ni{sub 36} measured slightly above the liquidus temperature is presented from experiments conducted on the nanoscale-ordered materials diffractometer (NOMAD) beam line at the SNS after only 30 min of acquisition time for a small sample (∼100 mg)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elasticity of methane hydrate phases at high pressure

Determination of the full elastic constants (c{sub ij}) of methane hydrates (MHs) at extreme pressure-temperature environments is essential to our understanding of the elastic, thermodynamic, and mechanical properties of methane in MH reservoirs on Earth and icy satellites in the solar system. Here, we have investigated the elastic properties of singe-crystal cubic MH-sI, hexagonal MH-II, and orthorhombic MH-III phases at high pressures in a diamond anvil cell. Brillouin light scattering measurements, together with complimentary equation of state (pressure-density) results from X-ray diffraction and methane site occupancies in MH from Raman spectroscopy, were used to derive elastic constants of MH-sI, MH-II, and MH-III phases at high pressures. Analysis of the elastic constants for MH-sI and MH-II showed intriguing similarities and differences between the phases′ compressional wave velocity anisotropy and shear wave velocity anisotropy. Our results show that these high-pressure MH phases can exhibit distinct elastic, thermodynamic, and mechanical properties at relevant environments of their respective natural reservoirs. These results provide new insight into the determination of how much methane exists in MH reservoirs on Earth and on icy satellites elsewhere in the solar system and put constraints on the pressure and temperature conditions of their environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron temporal diagnostic for high-yield deuterium–tritium cryogenic implosions on OMEGA

A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic deuterium–tritium (DT) implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments—a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ∼16 m to a streak camera in a well-shielded location. An ∼200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ∼40 ± 10 ps was measured in a dedicated experiment using hard x-rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. The measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent high-power RF wakefield generation by electron bunch trains in a metamaterial structure

In this paper, we present an experimental study of coherent high-power wakefield generation in a metamaterial (MTM) structure at 11.7 GHz by 65 MeV electron bunch trains at the Argonne Wakefield Accelerator (AWA), following a previous experiment, the Stage-I experiment, at the AWA. Both the Stage-II experiment, reported in this paper, and the Stage-I experiment were conducted using MTM structures, which are all-metal periodic structures with the period being much smaller than the wavelength. Differences between the two experiments include (1) structure length (Stage-I 8 cm and Stage-II 20 cm); (2) number of bunches used to excite the structure (Stage-I with two bunches, up to 85 nC of total charge; Stage-II with eight bunches, up to 224 nC of total charge); and (3) highest peak power measured (Stage-I 80 MW in a 2 ns pulse and Stage-II 380 MW in a 10 ns pulse). High-power radio frequency pulses were generated by reversed Cherenkov radiation of the electron beam due to the negative group velocity in the MTM structures. Because the radiation is coherent, a train of bunches with a proper spacing can build up to achieve a high peak power. The observed output power levels are very promising for future applications in direct collinear wakefield acceleration or in transfer to a second accelerator for two-beam acceleration.

36 MATERIALS SCIENCE↗

Graded Buffer Bragg Reflectors with High Reflectivity and Transparency for Metamorphic Optoelectronics

A graded buffer Bragg reflector (GBBR) is a bifunctional device component that provides the reflection of a distributed Bragg reflector and the adjustable lattice constant of a compositionally graded buffer. Prior work showed that these properties can be combined with low threading dislocation density and high reflectivity. Here, we design and demonstrate complex GBBRs for specific metamorphic solar cell applications. We design buffers that provide (1) high reflectivity over a narrow bandwidth, for quantum well solar cells, (2) reflectivity over a wide bandwidth, for optically thin solar cells, and (3) low sidelobe reflection, for multijunction devices that demand low out-of-band reflection. Apodized and triple GBBRs are demonstrated, and transparency is always considered, requiring designs with carefully engineered material combinations. A GBBR with a reflection of 99% is demonstrated, as well as a triple GBBR that has over 80% reflection for 100?nm of the spectrum around 800?nm. We also analyze potential deviations in a baseline GBBR from that of a perfect DBR using transmission electron microscopy to analyze imperfections in the material and modeling to analyze the impact of imperfect refractive index data for lattice-mismatched AlGaInAs. Minimal crosshatch roughness and unintentional thickness variation occur throughout the buffer, which likely influences reflection slightly. Small deviations between the calculated AlGaInAs and utilized AlGaAs refractive index exist, giving methods for future GBBR improvement. While the GBBR designs are intended for metamorphic solar cells, the broad and high reflection may also be useful for other optoelectronic devices such as light-emitting diodes or lasers.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Lattice engineering of high-entropy olivine-type lithium metal phosphate as high-voltage cathodes

Engineering of high-entropy cathode materials for lithium-ion batteries has been actively pursued owing to the outstanding conductivity of high-entropy materials benefited from the maximum entropy and unique antisite disordering structure. Olivine lithium metal phosphates such as LiMnPO 4 and LiNiPO 4 feature high working voltages but low capacities due to their insulation nature. Here in this work, the synthesis of the high-entropy lithium metal phosphate materials (HELMPs) is realized by combining mechanochemistry with a calcination method. By regulating lattice of HELMPs, the high-entropy Li(Mn 0.35 Fe 0.35 Co0.1Mg 0.1 Ca 0.1 )PO 4 reveals three typical high-voltage plateaus in charge–discharge curves corresponding to the redox of Fe, Mn, and Co in the voltage range of 2.0–4.9 V vs Li + /Li, and a much higher initial capacity than LiMnPO 4 (104 vs 15 mAh g -1 ).

25 ENERGY STORAGE↗

Highly efficient nonprecious metal catalyst prepared with metal–organic framework in a continuous carbon nanofibrous network

Fuel cell vehicles, the only all-electric technology with a demonstrated >300 miles per fill travel range, use Pt as the electrode catalyst. The high price of Pt creates a major cost barrier for large-scale implementation of polymer electrolyte membrane fuel cells. Nonprecious metal catalysts (NPMCs) represent attractive low-cost alternatives. However, a significantly lower turnover frequency at the individual catalytic site renders the traditional carbon-supported NPMCs inadequate in reaching the desired performance afforded by Pt. Unconventional catalyst design aiming at maximizing the active site density at much improved mass and charge transports is essential for the next-generation NPMC. We report here a method of preparing highly efficient, nanofibrous NPMC for cathodic oxygen reduction reaction by electrospinning a polymer solution containing ferrous organometallics and zeolitic imidazolate framework followed by thermal activation. The catalyst offers a carbon nanonetwork architecture made of microporous nanofibers decorated by uniformly distributed high-density active sites. In a single-cell test, the membrane electrode containing such a catalyst delivered unprecedented volumetric activities of 3.3 A∙cm -3 at 0.9 V or 450 A∙cm -3 extrapolated at 0.8 V, representing the highest reported value in the literature. Improved fuel cell durability was also observed.

30 DIRECT ENERGY CONVERSION↗