Trust Model Measurements for the Energy Grid of Things

Information security is essential for the reliable operation of an Energy Grid of Things (EGoT). In addition to basic information security protocols as defined by published standards, there is a need for a monitoring function that measures the trustworthiness of the various actors participating in an EGoT. We describe in this paper the implementation and evaluation of a Distributed Trust Model that was developed specifically for monitoring communication within an EGoT. We then show how the model parameters are set using statistical measures for hypothesis testing.

Energy Grid of Things, EGoT, Smart Grid Security, ↗

Understanding Regional Inertia Dynamics in CAISO from Real Grid Disturbances

The shift from synchronous generators to inverter-based resources has caused power system inertia to be unevenly distributed across power grids. As a result, certain grid regions are more vulnerable to high rate-of-change of frequency (RoCoF) during disturbances. This paper presents a measurement-based framework for estimating grid inertia in CAISO (California Independent System Operator) region using real disturbance-driven frequency data from the Frequency Monitoring Network (FNET/GridEye). By analyzing confirmed disturbances from 2013 to 2024, we identify trends in regional inertia and frequency dynamics, highlighting their relationship with renewable generation and the evolving duck curve. Regional RoCoF values were up to six times higher than interconnection-wide values, coinciding with declining inertia. Recent recovery in inertia is attributed to the increased deployment of battery energy storage systems with synthetic inertia capabilities. These findings underscore the importance of regional inertia monitoring, strategic resource planning, and adaptive operational practices to ensure grid reliability amid growing renewable integration.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Cyber Resilient Design and Controls for Energy Systems

As the grid of today is evolving into a highly distributed and autonomous cyber-physical system with higher penetration of Distributed Energy Resources (DERs) and autonomous controls that are dependent on the cyber infrastructure, there are novel and increasing challenges to cyber-resilient operation of the grid. While the traditional mechanisms take a "bolt on" approach to cybersecurity and resiliency, this talk presents two novel technologies developed at NREL that "bake in" security and resilience into the design and control of the grid. An Adaptive Resilience Metrics framework is a novel mechanism for system owners and operators to understand the impact of cyber and physical system design and topology on the resilient operation, while also helping determine optimal policies in response to adverse cyber events. Along with that a zero-knowledge proof-based technique helps incorporate security into the controls layer by focusing on computational integrity rather than data integrity. By leveraging design and control properties unique to Operational Technology systems these technologies will not only help enhance cyber-resilience for the grid of today, but a highly distributed and autonomous grid of tomorrow.

cyber resilience↗

Performance Specifications for Grid-Forming Technologies

Standards and specifications for inverter-based resources (IBRs) focus primarily on grid-following (GFL) technologies at present. Therefore, these may generally not be appropriate for application in power systems to ensure acceptable operation with grid-forming (GFM) technologies. In some cases, the direct application of prevailing standards and specifications may not be appropriate for - or may even inadvertently limit the potential of - GFM resources. The Universal Interoperability for Grid- Forming Inverters (UNIFI) Consortium is a U.S. Department of Energy funded effort to advance GFM technology. The UNIFI team brings together academic, industrial, and national-lab researchers as well as industry stakeholders (utilities, system operators, vendors) to collaboratively pursue advances in a broad range of GFM technologies. This paper introduces a set of system- and unit-level specifications driven by consensus across the UNIFI project team. These are intended to seamlessly integrate GFM technologies at any scale into power-systems operation and control in a vendor-agnostic manner. A suite of illustrative simulation results that demonstrate the application of and adherence to the proposed specifications are included.

grid-forming inverter↗

Development of a Power Electronics-based Testbed for a Flexible Combined Heat and Power System

A flexible combined heat and power (F-CHP) concept, enabled by a power electronics-based power conditioning system (PCS), has been recently proposed as a cost-effective way for supporting the grid with high penetration of renewable energy sources. To verify the design, control, and performance of the overall system, a laboratory-scale testbed is essential. This paper focuses on the development of a power electronics-based testbed for such a F-CHP system. The developed testbed can test the control, grid-connected mode operation, islanded mode operation, and mode transitions, including planned/unplanned islanding and reconnection, of the F-CHP system. In the grid-connected mode, both the steady state and transients of the ac grid can be emulated, and various grid support functions can be tested with the help of the developed PCS converter. In the islanded mode, the external ac loads can also be supported by the F-CHP system. Also, the central controller, which is implemented in a NI CompactRIO, can be tested. Experimental test results for the grid-connected mode, islanded mode, and mode transitions are provided to validate the testbed design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stability enhancement module for grid-following converters: Hardware implementation and validation

Low-frequency oscillations limit power delivery of voltage-source converter interfaced resources, for example, wind and solar, operating in grid-following control mode. Our prior research identified the instability mechanism as the coupling between real power and voltage at point of common coupling. In turn, a stability enhancement control was proposed to weaken the coupling by introducing a simple voltage-based feedback loop. The stability enhancement control has been validated via electromagnetic transient simulation testbeds. The objectives of this paper are (a) to provide a more insightful explanation of the enhancement module by examining the impedance of the grid-following converter and (b) to verify the performance of the stability module using a hardware testbed. The theoretic examination demonstrates that stability enhancement module effectively reduces the negative resistance effect of $Z_{qq}$ and thus boosts stability. The experimental research leads to a hardware testbed of a grid-following converter with the ability of demonstrating low-frequency oscillations. Finally, the experimental results demonstrate the efficacy of the proposed stability enhancement control and the readiness of commercial realization of the stability enhancement unit.

42 ENGINEERING↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel Cell Inverter Dataset

This data set contains the three phase AC voltage, three phase AC current, DC voltage and DC current. These data sets were captured during fuel cell inverter operation in grid-connected dispatch, islanded load changes, transition from grid-connected mode to islanded mode and vice-versa.

25 ENERGY STORAGE↗

The screen hole plasma sheath of an ion accelerator system

Results of the first probing of the screen hole sheath of an ion accelerator system are presented. The screen hole sheath, represented as a set of equipotential contours, extends over a large distance within the discharge plasma. Under no conditions examined does the sheath enter the screen hole. Edge hole defocusing of multiaperture accelerator systems is due primarily to local plasma density variations rather than adjacent screen hole sheath interactions. The sheath boundary is independent of screen-to-accelerator grid spacing when the grid set is operated at the minimum ion beam divergence condition. Significant ion focusing effects occur in the sheath adjacent to the screen grid webbing leading to increased ion source beam current efficiency with decreasing screen-to-accelerator grid separation and/or screen grid thickness.

Aston, G.↗

Satellite Power System. Concept development and evaluation program, volume 6: Construction and operations

The construction, operation, and maintenance requirements for a solar power satellite, including the space and ground systems, are reviewed. The basic construction guidelines are explained, and construction location options are discussed. The space construction tasks, equipment, and base configurations are discussed together with the operations required to place a solar power satellite in geosynchronous orbit. A rectenna construction technique is explained, and operation with the grid is defined. Maintenance requirements are summarized for the entire system. Key technology issues required for solar power satellite construction operations are defined.

Benson, H.↗

A Review of the Generic Grid-Forming Model Used by the System Operator in Chile

The objective in this project is to verify the applicability of using generic electro-magnetic transient domain models of GFM technology through a wide range of tests and system conditions proposed by subject matter experts of GFM technology through a wide range of tests and system conditions proposed by subject matter experts. For this study, we used the generic GFM electro-magnetic transient model available in the EMTP (Electromagnetic Transient Program) software library, and we assessed the model’s various GFM capabilities through 12 tests. In this report, we compare the performance of the model with that of an original equipment manufacturer (OEM) GFM model. We also share the key insights and lessons learned from this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical wave modeling for operational and survival analyses of wave energy converters at the US Navy Wave Energy Test Site in Hawaii

The US Navy Wave Energy Test Site (WETS) is currently operating three grid-connected berths off Marine Corps Base Hawaii in support of technological development through scaled-model testing and pre-commercial prototyping. The location on the east shore of Oahu is open to year-round wind waves and seasonal north swells as well as severe seas from subtropical systems and hurricanes. We have assembled a spectral wave model system comprising WAVEWATCH III and SWAN on a hierarchy of global, regional, and nearshore computational grids. With wind forcing from global forecast and rean-alysis datasets as well as their regional downscaling, the system produces operational 7-day wave forecasts and a long-term hindcast. The daily forecasts, validated with real-time buoy measurements, facilitate safe deployment, operation, and retrieval of wave energy converters (WECs). The wave hindcast from 1979 to 2017 defines the intra- and inter-annual variations for statistical analysis of sea states and energy resources. Due to limited occurrences of hurricanes in Hawaii waters, their wind forcing is determined parametrically with simulated tracks from climate model downscaling. Finally, systematic analysis of the hindcast and simulation datasets provides significant wave heights from trade winds, swells, subtropical systems, and hurricanes with return periods up to 100 years for WECs survival analysis.

16 TIDAL AND WAVE POWER↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.