Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Exchange Coupling Determines Metal-Dependent Efficiency for Iron- and Cobalt-Catalyzed Photochemical CO 2 Reduction

Catalysts promoting multielectron charge delocalization offer selectivity for the CO 2 reduction reaction (CO 2 RR) over the competing hydrogen evolution reaction. Here, we show metal–ligand exchange coupling as an example of charge delocalization that can determine the efficiency for photocatalytic CO 2 RR. A comparative evaluation of iron and cobalt complexes supported by the redox-active ligand tpyPY2Me establishes that the two-electron reduction of [Co(tpyPY2Me)] 2+ ([Co] 2+ ) occurs at potentials 770 mV more negative than the [Fe(tpyPY2Me)] 2+ ([Fe] 2+ ) analogue by maximizing the exchange coupling in the latter compound. The positive shift in the reduction potential promoted by metal–ligand exchange coupling drives [Fe] 2+ to be among the most active and selective molecular catalysts for photochemical CO 2 RR reported to date, maintaining up to 99% CO product selectivity with total turnover numbers (TONs) and initial turnover frequencies exceeding 30,000 and 900 min –1 , respectively. In contrast, [Co] 2+ shows much lower CO 2 RR activity, reaching only ca. 600 TON at 83% CO product selectivity under similar conditions accompanied by rapid catalyst decomposition. Further, the spin density plots of the two-electron reduced [Co] 0 complex implicate a paramagnetic open-shell doublet ground state compared to the diamagnetic open-shell singlet ground state of reduced [Fe] 0 , rationalizing the observed negative shift in two-electron reduction potentials from the [M] 2+ species and lowered CO 2 RR efficiency for the cobalt complex relative to its iron congener. This work emphasizes the contributions of multielectron metal–ligand exchange coupling in promoting effective CO 2 RR and provides a starting point for the broader incorporation of this strategy in catalyst design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of experimental rotor damping data-reduction techniques

The ability of existing data reduction techniques to determine frequency and damping from transient time-history records was evaluated. Analog data records representative of small-scale helicopter aeroelastic stability tests were analyzed. The data records were selected to provide information on the accuracy of reduced frequency and decay coefficients as a function of modal damping level, modal frequency, number of modes present in the time history record, proximity to other modes with different frequencies, steady offset in time history, and signal-to-noise ratio. The study utilized the results from each of the major U.S. helicopter manufacturers, the U.S. Army Aeroflightdynamics Directorate, and NASA Ames Research Center using their inhouse data reduction and analysis techniques. Consequently, the accuracy of different data analysis techniques and the manner in which they were implemented were also evaluated. It was found that modal frequencies can be accurately determined even in the presence of significant random and periodic noise. Identified decay coefficients do, however, show considerable variation, particularly for highly damped modes. The manner in which the data are reduced and the role of the data analyst was shown to be important. Although several different damping determination methods were used, no clear trends were evident for the observed differences between the individual analysis techniques. It is concluded that the data reduction of modal-damping characteristics from transient time histories results in a range of damping values.

Warmbrodt, William↗

A high-frequency survey of the southern Galactic plane for pulsars

Results of an HF survey designed to detect young, distant, and short-period pulsars are presented. The survey detected a total of 100 pulsars, 46 of which were previously unknown. The periods of the newly discovered pulsars range between 47 ms and 2.5 ms. One of the new discoveries, PSR 1259-63, is a member of a long-period binary system. At least three of the pulsars have ages less than 30,000 yr, bringing the total number of such pulsars to 12. The majority of the new discoveries are distant objects with high dispersion measures, which are difficult to detect at low frequencies. This demonstrates that the survey has reduced the severe selection effects of pulse scattering, high Galactic background temperature, and dispersion broadening, which hamper the detection of such pulsars at low radio frequencies. The pulsar distribution in the southern Galaxy is found to extend much further from the Galactic center than that in the north, probably due to two prominent spiral arms in the southern Galaxy.

Johnston, Simon↗

Implementation of a feature selection algorithm in FARM to identify important state variables and time-invariant matrices

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM aids the HERON software module in the evaluation of the optimal dispatch for the different IES components. Set-point trajectories are required to meet limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To evaluate the feasibility of HERON generated set-points and to do so in an acceptable time, FARM employs reduced order models to represent the dynamic behavior of the systems to be dispatched. These surrogate models take the form of a linear dynamic system with sets of Linear Parameter Varying (LPV) matrices that are mapped to the system operating space. These matrices are derived from the trajectories of system state variables and system output variables during transients. The accuracy of LPV matrices depends on the selection of state variables. In previous reports, state variables were selected by adopting a complicated workflow requiring multiple software licenses and an advanced level of user expertise. In this report, a new workflow that automates the state variable selection process is presented. It significantly reduces the frequency of user interventions and does not require multiple software licenses. Each module in the new workflow is described in detail, and the input / output examples in each step of the workflow are provided. It was demonstrated that this workflow can greatly reduce the complexity of the state variable selection process, and that the updated FARM-Gamma and FARM-Delta validators can benefit from this workflow when solving the power dispatch problem of a representative IES test case. Finally, some code improvements that can further enhance the efficiency are suggested.

42 ENGINEERING↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method of locating persons in distress

A method for locating any person in distress in a selected area on the surface of the earth who has deployed passive radio frequency (RF) reflectors in a predetermined arrangement is analyzed. A first transparency is made in the spatial frequency domain of an image of said predetermined arrangement of said RF reflectors. The said selected area of the surface of the earth is scanned by means of a side-looking radar, on board a satellite or aircraft, to produce radar images. Second transparencies in the conventional image domain are produced from the radar images. It is then determined from the first and second transparencies, by means of complex spatial filtering.

Sivertson, W. E., Jr.↗

VLA observations of a complete sample of extragalactic X-ray sources. II

A complete sample of 35 X-ray selected sources found with the Einstein Observatory has been observed with the Very Large Array at 6 cm to investigate the relationship between radio and X-ray emission in extragalactic objects. Detections include three active galactic nuclei (AGNs), two clusters or groups of galaxies, two individual galaxies, and two BL Lac objects. The frequency of radio emission in X-ray selected AGNs is compared with that of optically selected quasars using the integral radio-optical luminosity function. The result suggests that the probability for X-ray selected quasars to be radio sources is higher than for those optically selected. No obvious correlation is found in the sample between the richness of X-ray luminosity of the cluster and the presence of a galaxy with radio luminosity at 5 GHz larger than 10 to the 30th ergs/s/Hz.

Schild, R.↗

Experimental observation of the geodesic acoustic frequency limit for the NBI-driven Alfvén eigenmodes in TJ-II

We study Alfvén Eigenmodes (AEs) in the TJ-II heliac in hydrogen plasmas heated by hydrogen cofield NBI. Taking advantage of the unique TJ-II flexibility in varying plasma current, we have observed strong variation of the AE frequency from f AE ~ 30 to ~ 220 kHz for selected modes. An advanced heavy ion beam probe diagnostic determines the spatial location and internal amplitudes of the modes. The modes satisfy a local AE dispersion relation including the geodesic acoustic frequency that represents the lowest frequency of the mode. Linear MHD-modeling with STELLGAP and FAR3D codes shows that the calculated temporal evolution of the mode frequency reproduces the observed maxima and minima at the same time intervals with a similar frequency range and the radial profile peaks near the outer edge of the observed one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic and Impedance Analysis of Fe 2 O 3 Nanoparticles for Chemical Warfare Agent Sensing Applications

A dire need for real-time detection of toxic chemical compounds exists in both civilian and military spheres. In this paper, we demonstrate that inexpensive, commercially available Fe 2 O 3 nanoparticles are capable of selective sensing of chemical warfare agents (CWAs) using frequency-dependent impedance spectroscopy, with additional potential as an orthogonal magnetic sensor. X-ray magnetic circular dichroism analysis shows that Fe 2 O 3 nanoparticles possess moderately lowered moment upon exposure to 2-chloroethyl ethyl sulfide (2-CEES) and diisopropyl methylphosphonate (DIMP) and significantly lowered moment upon exposure to dimethyl methylphosphonate (DMMP) and dimethyl chlorophosphate (DMCP). Associated X-ray absorption spectra confirm a redox reaction in the Fe 2 O 3 nanoparticles due to CWA structural analog exposure, with differentiable energy-dependent features that suggest selective sensing is possible, given the correct method. Impedance spectroscopy performed on samples dosed with DMMP, DMCP, and tabun (GA, chemical warfare nerve agent) showed strong, differentiable, frequency-dependent responses. The frequency profiles provide unique “shift fingerprints” with which high specificity can be determined, even amongst similar analytes. The results suggest that frequency-dependent impedance fingerprinting using commercially available Fe 2 O 3 nanoparticles as a sensor material is a feasible route to selective detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced tensor polarization in solid-state targets

In this work, we report measurements of enhanced tensor polarization on solid-state targets. The results here represent an increase in tensor polarization over that previously achieved in high energy and nuclear scattering experiments that focused on the measurement of tensor polarized observables. Enhancement techniques are used which require RF produced close to the Larmor frequency of the target spins and use selective semi-saturation resulting from two sources of irradiation, microwave for the DNP process and the additional RF used to manipulate the population of the energy levels in the target material. The spin dynamics of the solid target are used to align the spins enhancing the ensemble average to improve the figure of merit of the scattering experiment. Target rotation at an optimized rate can lead to additional enhancement by applying selective semi-saturation in polycrystalline materials that possess a Pake doublet in their NMR signal.

47 OTHER INSTRUMENTATION↗

Fourier Transform-Plasmon Waveguide Spectroscopy: A Nondestructive Multifrequency Method for Simultaneously Determining Polymer Thickness and Apparent Index of Refraction

Fourier transform (FT)-plasmon waveguide resonance (PWR) spectroscopy measures light reflectivity at a waveguide interface as the incident frequency and angle are scanned. Under conditions of total internal reflection, the reflected light intensity is attenuated when the incident frequency and angle satisfy conditions for exciting surface plasmon modes in the metal as well as guided modes within the waveguide. Expanding upon the concept of two-frequency surface plasmon resonance developed by Peterlinz and Georgiadis [ Opt. Commun. 1996, 130, 260], the apparent index of refraction and the thickness of a waveguide can be measured precisely and simultaneously by FT-PWR with an average percent relative error of 0.4%. Measuring reflectivity for a range of frequencies extends the analysis to a wide variety of sample compositions and thicknesses since frequencies with the maximum attenuation can be selected to optimize the analysis. Additionally, the ability to measure reflectivity curves with both p- and s-polarized light provides anisotropic indices of refraction. FT-PWR is demonstrated using polystyrene waveguides of varying thickness, and the validity of FT-PWR measurements are verified by comparing the results to data from profilometry and atomic force microscopy (AFM).

36 MATERIALS SCIENCE↗

Low repetition rate and broad frequency tuning from a grating-coupled passively mode-locked quantum dot laser

Passively mode-locked quantum dot lasers with a grating-coupled external cavity arrangement are investigated. A broad repetition-rate tuning range of fundamental mode-locking from 2 GHz to a record-low frequency of 79.3 MHz is achieved with selecting the wavelength at 1.28 μm. A narrow RF linewidth of ∼25 Hz and an intrinsic linewidth as low as 0.15 Hz are also obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Ku band pulsed electron paramagnetic resonance spectrometer using an arbitrary waveform generator for quantum control experiments at millikelvin temperatures

We present a 17 GHz (Ku band) arbitrary waveform pulsed electron paramagnetic resonance spectrometer for experiments down to millikelvin temperatures. The spectrometer is located at room temperature, while the resonator is placed either in a room temperature magnet or inside a cryogen-free dilution refrigerator; the operating temperature range of the dilution unit is from ca. 10 mK to 8 K. This combination provides the opportunity to perform quantum control experiments on electron spins in the pure-state regime. At 0.6 T, spin echo experiments were carried out using γ-irradiated quartz glass from 1 K to 12.3 mK. With decreasing temperatures, we observed an increase in spin echo signal intensities due to increasing spin polarizations, in accordance with theoretical predictions. Through experimental data fitting, thermal spin polarization at 100 mK was estimated to be at least 99%, which was almost pure state. Next, to demonstrate the ability to create arbitrary waveform pulses, we generate a shaped pulse by superposing three Gaussian pulses of different frequencies. The resulting pulse was able to selectively and coherently excite three different spin packets simultaneously—a useful ability for analyzing multi-spin system and for controlling a multi-qubit quantum computer. By applying this pulse to the inhomogeneously broadened sample, we obtain three well-resolved excitations at 8 K, 1 K, and 14 mK.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A frequency tunable, eight-channel correlation ECE system for electron temperature turbulence measurements on the DIII-D tokamak

A new eight-channel correlation electron cyclotron emission diagnostic has recently been installed on the DIII-D tokamak to study both turbulent and coherent electron temperature fluctuations under various plasma conditions and locations. This unique system is designed to cover a broad range of operation space on DIII-D (1.6-2.1 T, detection frequency: 72-108 GHz) via four remotely selected local oscillators (80, 88, 96, and 104 GHz). Eight radial locations are measured simultaneously in a single discharge covering as much as half the minor radius. In this paper, we present design details of the quasi-optical system, the receiver, as well as representative data illustrating operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AlN/AlGaN/AlN quantum well channel HEMTs

We present a compositional dependence study of electrical characteristics of AlxGa1−xN quantum well channel-based AlN/AlGaN/AlN high electron mobility transistors (HEMTs) with x=0.25,0.44, and 0.58. This ultra-wide bandgap heterostructure is a candidate for next-generation radio frequency and power electronics. The use of selectively regrown n-type GaN Ohmic contacts results in contact resistance that increases as the Al content of the channel increases. The DC HEMT device characteristics reveal that the maximum drain current densities progressively reduce from 280 to 30 to 1.7 mA/mm for x=0.25,0.44, and 0.58, respectively. This is accompanied by a simultaneous decrease (in magnitude) in threshold voltage from −5.2 to −4.9 to −2.4 V for the three HEMTs. This systematic experimental study of the effects of Al composition x on the transistor characteristics provides valuable insights for engineering AlGaN channel HEMTs on AlN for extreme electronics at high voltages and high temperatures.

Physics↗

Performance Impact of I/O on QMCPack Simulations at the Petascale and Beyond

Traditional petascale applications, such as QMCPack, can scale their computations to completely utilize modern supercomputers like Titan, but they cannot scale their I/O. To preserve scalability, scientists cannot save data at the granularity needed to enable scientific discovery and are forced to use large intervals between two checkpoint calls. In this paper, we work to increase the granularity of the I/O in QMCPack simulations without increasing the I/O associated overhead or compromising the scalability of the simulations. Our solution redesigns the I/O algorithms used by QMCPack to gather finer-grained data at high frequencies and integrate the ADIOS API to select effective I/O methods without major code changes. The extension of a tool such as Skel to mimic the variable I/O in QMCPack allows us to predict the I/O performance of the code when using ADIOS methods at the petascale. We show how I/O libraries like ADIOS allow us to increase the amount of scientific data extracted from QMCPack simulations at the granularity desired by the scientists while keeping the I/O overhead below 10%. We also show how the impact of checkpoint I/O for the QMCPack code using ADIOS is below 5% when using preventive tactics for checkpointing at the petascale and beyond.

Herbein, Stephen N↗

Wide-Bandwidth, Wide-Beamwidth, High-Resolution, Millimeter-Wave Imaging for Concealed Weapon Detection

Active millimeter-wave imaging is currently being used for personnel screening at airports and other high-security facilities. The lateral resolution, depth resolution, clothing penetration, and image illumination quality obtained from next-generation systems can be significantly enhanced through the selection the aperture size, antenna beamwidth, center frequency, and bandwidth. In this paper, the results of an extensive imaging trade study are presented using both planar and cylindrical three-dimensional imaging techniques at frequency ranges of 10-20 GHz, 10 – 40 GHz, 40 – 60 GHz, and 75 – 105 GHz

Concealed-Weapon Detection↗

TH-E-17A-01: Internal Respiratory Surrogate for 4D CT Using Fourier Transform and Anatomical Features

Purpose: To develop a novel algorithm to generate internal respiratory signals for sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm extracted multiple time resolved features as potential respiratory signals. These features were taken from the 4D CT images and its Fourier transformed space. Several low-frequency locations in the Fourier space and selected anatomical features from the images were used as potential respiratory signals. A clustering algorithm was then used to search for the group of appropriate potential respiratory signals. The chosen signals were then normalized and averaged to form the final internal respiratory signal. Performance of the algorithm was tested in 50 4D CT data sets and results were compared with external signals from the real-time position management (RPM) system. Results: In almost all cases, the proposed algorithm generated internal respiratory signals that visibly matched the external respiratory signals from the RPM system. On average, the end inspiration times calculated by the proposed algorithm were within 0.1 s of those given by the RPM system. Less than 3% of the calculated end inspiration times were more than one time frame away from those given by the RPM system. In 3 out of the 50 cases, the proposed algorithm generated internal respiratory signals that were significantly smoother than the RPM signals. In these cases, images sorted using the internal respiratory signals showed fewer artifacts in locations corresponding to the discrepancy in the internal and external respiratory signals. Conclusion: We developed a robust algorithm that generates internal respiratory signals from 4D CT images. In some cases, it even showed the potential to outperform the RPM system. The proposed algorithm is completely automatic and generally takes less than 2 min to process. It can be easily implemented into the clinic and can potentially replace the use of external surrogates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗