Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Quantitative assessment of Distributed Acoustic Sensing at the Source Physics Experiment (Phase II)

In this report, we assess the data recorded by a Distributed Acoustic Sensing (DAS) cable deployed during the Source Physics Experiment, Phase II (DAG) in comparison with the data recorded by nearby 4.5-Hz geophones. DAS is a novel recording method with unprecedented spatial resolution, but there are significant concerns around the data fidelity as the technology is ramped up to more common usage. Here we run a series of tests to quantify the similarity between DAS data and more conventional data and investigate cases where the higher spatial resolution of the DAS can provide new insights into the wavefield. These tests include 1D modeling with seismic refraction and bootstrap uncertainties, assessing the amplitude spectra with distance from the source, measuring the frequency dependent inter-station coherency, estimating time-dependent phase velocity with beamforming and semblance, and measuring the cross-correlation between the geophone and the particle velocity inferred from the DAS. In most cases, we find high similarity between the two datasets, but the higher spatial resolution of the DAS provides increased details and methods of estimating uncertainty.

58 GEOSCIENCES↗

Predicted and measured strain response of rectangular panels due to acoustic loading

The objective of the research described in this paper is to assess the accuracy of classical linear acceleration/strain prediction theory for flat, rectangular panels excited by low level, acoustic plane waves. Predictions for both aluminum and laminated composite panels were based on the Ritz method using an orthotropic, multi-mode analysis with rotational springs on the boundaries. The measured natural frequencies and critical damping ratio of the panels were empirial inputs to the model. The comparison between measured and predicted acceleration was very good. Although a factor of three bias error was found between measured and predicted strains, the model was good for predicting the trends in the spatial variation in strain across the panel.

Roussos, L. A.↗

Biogeochemistry of DMS in Surface Waters

Dimethylsulfide (DMS) is important in influencing the formation of aerosols in the troposphere over large areas of the world's oceans. Understanding the dynamics of aerosols is important to understanding the earth's radiation balance. In evaluating the factors controlling DMS in the troposphere it is vital to understand the dynamics of DMS in the surface ocean. The biogeochemical processes controlling DMS concentration in seawater are myriad; modeling and theoretical estimation are problematic. At the beginning of this project we believed that we were on the verge of simplifying the ship-track measurement of DMS, and we proposed to deploy such a system to develop a database relating high frequency DMS measurements to biological and physicochemical and optical properties of surface water that can be quantified by remote sensing techniques. We designed a system to measure DMS concomitantly with other basic chemical and biological data in a flow-through system. The project was collaborative between Woods Hole Oceanographic Institution (WHOI) and Bermuda Biological Station for Research (BBSR). The project on which we are reporting was budgeted for only one year with a one year no-cost extension. At WHOI our effort was directed towards designing traps which would be used to concentrate DMS from seawater and allow storage for subsequent analysis. At that time, GC systems were too large for easy long-term deployment on a research vessel like R/V Weatherbird, so we focused on simplifying the shipboard sampling procedure. Initial studies of sample recovery with high levels of DMS suggested that Carboxen 1000, a relatively new carbon molecular sieve, could be used as a stable storage medium. The affinity of Carboxen for DMS is several orders of magnitude higher than gold wool (another adsorbent used for DMS collection) on a weight or volume basis. Furthermore, Carboxen's affinity for DMS is also far less susceptible to humidity than gold wool. Unfortunately, further experiments with low level DMS indicated that recovery of DMS after storage was not quantitative. The material has proven to be completely acceptable for short term storage and has been incorporated into a micro-GC system. Since working on this project, we have collaborated with RVM Scientific in Santa Barbara in the design and construction of small portable micro-GC's that will make feasible at-sea measurement in moving ships, making rapid gas analysis and quantification feasible in a ship-track mode. Throughout this period at both WHOI and BBSR, we continued to analyze field data to understand that patterns of time and space variability in DMS and the processes that govern it. These insights will be crucial to determining the specifications for our automated sampling program. The data from this, the longest continuous sampling program for ocean DMS, provided insights into year to year and short-term variability.

Dacey, J. W. H.↗

Temperature Evolution of Excitonic Absorptions in Cd(1-x)Zn(x)Te Materials

The studies consist of measuring the frequency dependent transmittance (T) and reflectance (R) above and below the optical band-gap in the UV/Visible and infrared frequency ranges for Cd(l-x),Zn(x),Te materials for x=0 and x=0.04. Measurements were also done in the temperature range from 5 to 300 K. The results show that the optical gap near 1.49 eV at 300 K increases to 1.62 eV at 5 K. Finally, we observe sharp absorption peaks near this gap energy at low temperatures. The close proximity of these peaks to the optical transition threshold suggests that they originate from the creation of bound electron-hole pairs or excitons. The decay of these excitonic absorptions may contribute to a photoluminescence and transient background response of these back-illuminated HgCdTe CCD detectors.

Quijada, Manuel A.↗

Science Results From The ARCADE Open-Aperture Cryogenic Balloon Payload

The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument to measure the frequency spectrum of the cosmic microwave background and diffuse Galactic foregrounds at centimeter wavelengths. ARCADE greatly reduces measurement uncertainties compared to previous balloon-borne or ground-based instrument using a double-nulled design that features fully cryogenic optics with no windows between the atmosphere and the 2.7 K instrument. A four-hour flight in 2006 achieved sensitivity comparable to the COBE/FIRAS satellite measurement while providing new insights for emission ranging from spinning dust in the interstellar medium to an unexpectedly bright extragalactic radio background. I will discuss scientific results from the ARCADE program and implications of the ARCADE cold optics for millimeter and sub-mm astronomy.

Kogut, Alan J.↗

Compact piezoelectric resonance mass balance for sample verification and mass quantification and mixing.

There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.

Yahnker, Christopher R.↗

Measuring a Fiber-Optic Delay Line Using a Mode-Locked Laser

The figure schematically depicts a laboratory setup for determining the optical length of a fiber-optic delay line at a precision greater than that obtainable by use of optical time-domain reflectometry or of mechanical measurement of length during the delay-line-winding process. In this setup, the delay line becomes part of the resonant optical cavity that governs the frequency of oscillation of a mode-locked laser. The length can then be determined from frequency-domain measurements, as described below. The laboratory setup is basically an all-fiber ring laser in which the delay line constitutes part of the ring. Another part of the ring - the laser gain medium - is an erbium-doped fiber amplifier pumped by a diode laser at a wavelength of 980 nm. The loop also includes an optical isolator, two polarization controllers, and a polarizing beam splitter. The optical isolator enforces unidirectional lasing. The polarization beam splitter allows light in only one polarization mode to pass through the ring; light in the orthogonal polarization mode is rejected from the ring and utilized as a diagnostic output, which is fed to an optical spectrum analyzer and a photodetector. The photodetector output is fed to a radio-frequency spectrum analyzer and an oscilloscope. The fiber ring laser can generate continuous-wave radiation in non-mode-locked operation or ultrashort optical pulses in mode-locked operation. The mode-locked operation exhibited by this ring is said to be passive in the sense that no electro-optical modulator or other active optical component is used to achieve it. Passive mode locking is achieved by exploiting optical nonlinearity of passive components in such a manner as to obtain ultra-short optical pulses. In this setup, the particular nonlinear optical property exploited to achieve passive mode locking is nonlinear polarization rotation. This or any ring laser can support oscillation in multiple modes as long as sufficient gain is present to overcome losses in the ring. When mode locking is achieved, oscillation occurs in all the modes having the same phase and same polarization. The frequency interval between modes, often denoted the free spectral range (FSR), is given by c/nL, where c is the speed of light in vacuum, n is the effective index of refraction of the fiber, and L is the total length of optical path around the ring. Therefore, the length of the fiber-optic delay line, as part of the length around the ring, can be calculated from the FSRs measured with and without the delay line incorporated into the ring. For this purpose, the FSR measurements are made by use of the optical and radio-frequency spectrum analyzers. In experimentation on a 10-km-long fiber-optic delay line, it was found that this setup made it possible to measure the length to within a fractional error of about 3 10(exp -6), corresponding to a length error of 3 cm. In contrast, measurements by optical time-domain reflectometry and mechanical measurement were found to be much less precise: For optical time-domain reflectometry, the fractional error was found no less than 10(exp -4) (corresponding to a length error of 1 m) and for mechanical measurement, the fractional error was found to be about 10(exp -2) (corresponding to a length error of 100 m).

Tu, Meirong↗

Measurement of the anomalous spin precession frequency $\omega_\alpha$ in the Muon g-2 experiment at Fermilab

The Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic moment anomaly, $a_{\mu} = (g-2)/2$, with a final accuracy of 0.14 parts per million (ppm). A $3.1$-GeV muon beam is injected into a storage ring of $14\,$m diameter, in the presence of a $1.45\,$T magnetic field. The anomaly $a_\mu$ can be extracted by accurately measuring the anomalous muon spin precession frequency $\omega_a$, based on the arrival time distribution of decay positrons observed by $24$ calorimeters, and the magnetic field. In 2023, the experiment published its second result based on the two datasets Run-2 and Run-3, reaching the unprecedented sensitivity of $0.21\,$ppm --- a factor $\sim2.2$ improvement since its first result published in 2021, based on the first dataset (Run-1). In this paper, we will focus on the measurement of the $\omega_a$ frequency, describing the techniques and major sources of systematic uncertainty in the 2023 publication, and outlining the improvements since the 2021 result. We will also cover the status of the ongoing $\omega_a$ analysis for the last three datasets, collected from 2020 to 2023, along with the projected uncertainties on the final Muon $g-2$ measurement at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Receiver performance of laser ranging measurements between the Lunar Observer and a subsatellite for lunar gravity studies

The optimal receiver for a direct detection laser ranging system for slow Doppler frequency shift measurement is shown to consist of a phase tracking loop which can be implemented approximately as a phase lock loop with a 2nd or 3rd order loop filter. The laser transmitter consists of an AlGaAs laser diode at a wavelength of about 800 nm and is intensity modulated by a sinewave. The receiver performance is shown to be limited mainly by the preamplifier thermal noise when a silicon avalanche photodiode is used. A high speed microchannel plate photomultiplier tube is shown to outperform a silicon APD despite its relatively low quantum efficiency at wavelengths near 800 nm. The maximum range between the Lunar Observer and the subsatellite for lunar gravity studies is shown to be about 620 km when using a state-of-the-art silicon APD and about 1000 km when using a microchannel plate photomultiplier tube in order to achieve a relative velocity measurement accuracy of 1 millimeter per second. Other parameters such as the receiver time base jitter and drift also limit performance and have to be considered in the design of an actual system.

Davidson, Frederic M.↗

Maser research program

Materials preparation and microwave bench measurements for zero-field traveling wave maser

MICROWAVE FREQUENCY↗

Implantable, Ingestible Electronic Thermometer

Small quartz-crystal-controlled oscillator swallowed or surgically implanted provides continuous monitoring of patient's internal temperature. Receiver placed near patient measures oscillator frequency, and temperature inferred from previously determined variation of frequency with temperature. Frequency of crystal-controlled oscillator varies with temperature. Circuit made very small and implanted or ingested to measure internal body temperature.

Kleinberg, Leonard↗

Discovery of a Doppler-limited CO line in the upper mesosphere of Venus - A new dynamical probe

The presence of CO in the upper atmosphere of Venus is a consequence of the photochemistry of CO2, the dominant atmospheric constituent. In December 1989 the J = 1-2 transition of CO was observed at 230 GHz. In addition to the broad absorption line first reported by Kakar et al. (1976), a narrow absorption feature at the center of the line due to upper mesospheric CO, where the temperature profile starts to exhibit diurnal variation with altitude. The narrow feature is approximately 600 kHz wide and is predominantly Doppler-broadened. The Doppler core provides a new means of measuring wind velocities at these altitudes in the atmosphere of Venus. Detection of small Doppler shifts in the line core can in principle be used to measure winds with an accuracy of 10 m/s. Results are presently limited by the 17 kHz uncertainty in the measured rest frequency, corresponding to a systematic error in wind velocity up to 22 m/s, and the absence of laboratory measurements of the pressure shift in CO by CO2.

Buhl, David↗

Track Structure Model for Radial Distributions of Electron Spectra and Event Spectra from High-Energy Ions

An analytic method is described for evaluating the average radial electron spectrum and the radial and total frequency-event spectrum for high-energy ions. For high-energy ions, indirect events make important contributions to frequency-event spectra. The method used for evaluating indirect events is to fold the radial electron spectrum with measured frequency-event spectrum for photons or electrons. The contribution from direct events is treated using a spatially restricted linear energy transfer (LET). We find that high-energy heavy ions have a significantly reduced frequency-averaged final energy (yF) compared to LET, while relativistic protons have a significantly increased yF and dose-averaged lineal energy (yD) for typical site sizes used in tissue equivalent proportional counters. Such differences represent important factors in evaluating event spectra with laboratory beams, in space- flight, or in atmospheric radiation studies and in validation of radiation transport codes. The inadequacy of LET as descriptor because of deviations in values of physical quantities, such as track width, secondary electron spectrum, and yD for ions of identical LET is also discussed.

Cucinotta, F. A.↗

Assembly of Colloidal Aggregates by Electrohydrodynamic Flow: Kinetic Experiments and Scaling Analysis

Electric fields generate transverse flows near electrodes that sweep colloidal particles into densely packed assemblies. We interpret this behavior in terms of electrohydrodynamic motion stemming from distortions of the field by the particles that alter the body force distribution in the electrode charge polarization layer. A scaling analysis shows how the action of the applied electric field generates fluid motion that carries particles toward one another. The resulting fluid velocity is proportional to the square of the applied field and decreases inversely with frequency. Experimental measurements of the particle aggregation rate accord with the electrohydrodynamic theory over a wide range of voltages and frequencies.

Ristenpart, W. D.↗

Preliminary Investigation of the Satellite Gravitational Red Shift Experiment

The work performed under this contract involved study, design, and construction of experimental equipment to perform a short-term measurement of the gravitational red shift. In the system designed, phase comparison techniques are employed so that the time interval required to obtain a single measurement for one altitude is of the order of one minute. An elliptical orbit was chosen to permit measurement of frequency shift as a function of altitude. One particularly attractive orbit is that having a 12-hour orbiting period (perigee, 270 miles, apogee 24,800 miles). This orbit, shown in Fig. 1, allows continuous measurements to be made over an 11-hour interval during which time the altitude is varying greatly. Measurements can not be made for the succeeding 14 hours. Since the variation of frequency difference with altitude is of greatest interest, a fixed offset or a slow drift between the oscillator on the ground and. the oscillator in the satellite will not invalidate the measurements.

Zacharias, J. R.↗

Quantum frequency processor for provable cybersecurity

Methods of quantum key distribution include receiving a frequency bin photon at a location, selecting a frequency bin photon quantum key distribution measurement basis, with a quantum frequency processor, performing a measurement basis transformation on the received frequency bin photon so that the frequency bin photon is measurable in the selected frequency bin photon quantum key distribution measurement basis, and detecting the frequency bin photon in the selected quantum key distribution measurement basis and assigning a quantum key distribution key value based on the detection to a portion of a quantum key distribution key. Apparatus and methods for encoding, decoding, transmitting, and receiving frequency bin photons are disclosed.

Lukens, Joseph M.↗

Quantum frequency processor for provable cybersecurity

Methods of quantum key distribution include receiving a frequency bin photon at a location, selecting a frequency bin photon quantum key distribution measurement basis, with a quantum frequency processor, performing a measurement basis transformation on the received frequency bin photon so that the frequency bin photon is measurable in the selected frequency bin photon quantum key distribution measurement basis, and detecting the frequency bin photon in the selected quantum key distribution measurement basis and assigning a quantum key distribution key value based on the detection to a portion of a quantum key distribution key. Apparatus and methods for encoding, decoding, transmitting, and receiving frequency bin photons are disclosed.

Lukens, Joseph M.↗

RXTE Observations of the Anomalous Pulsar 4U 0142+61

We observed the anomalous X-ray pulsar 4U 0142+6l using the Proportional Counter Array (PCA) aboard the Rossi X-ray Timing Explorer (RXTE) in March 1996. The pulse frequency was measured as epsilon = 0.11510039(3) Hz with an upper limit of |epsilon| </= 4 x 10(exp -13) Hz s(exp -1) upon the short term change in frequency over the 4.6 day span of the observations. A compilation of all historical measurements showed an overall spin-down trend with slope epsilon = -3.0 +/- 0.1 x 10(exp -14) Hz s(exp -1). Searches for orbital modulations in pulse arrival times yielded an upper limit of a(sub x) sin i approximately less than 0.26 It-s (99% confidence) for the period range 70 s to 2.5 days. These limits combined with previous optical limits and evolutionary arguments suggest that 4U 0142+61 is not a member of a binary system.

Wilson, Colleen A.↗