Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “form factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Forward doubly-virtual Compton scattering off an unpolarized deuteron in pionless effective field theory

In this work, we calculate the forward unpolarised doubly-virtual Compton scattering (VVCS) off the deuteron in the framework of pionless effective field theory, up to next-to-next-to-next-to-leading order (N3LO) for the longitudinal and next-to-leading order (NLO) for the transverse amplitude. The charge elastic form factor of the deuteron, obtained from the residue of the longitudinal VVCS amplitude, is used to extract the value of the single unknown two-nucleon one-photon contact coupling that enters the longitudinal amplitude at N3LO. We also study the lowest spin-independent generalised polarisabilities of the deuteron. The calculated unpolarised VVCS amplitude provides a high-precision model-independent input for a future calculation of the two-photon-exchange correction to the Lamb shift of muonic deuterium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative properties of clustering within modern microscopic nuclear models

A method for studying cluster spectroscopic properties of nuclear fragmentation, such as spectroscopic amplitudes, cluster form factors, and spectroscopic factors, is developed on the basis of modern precision nuclear models that take into account the mixing of large-scale shell-model configurations. Alpha-cluster channels are considered as an example. A mathematical proof of the need for taking into account the channel-wave-function renormalization generated by exchange terms of the antisymmetrization operator (Fliessbach effect) is given. Examples where this effect is confirmed by a high quality of the description of experimental data are presented. By and large, the method in question extends substantially the possibilities for studying clustering phenomena in nuclei and for improving the quality of their description.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nonrenormalization and Operator Mixing via On-Shell Methods

Using on-shell methods, we present a new perturbative nonrenormalization theorem for operator mixing in massless four-dimensional quantum field theories. By examining how unitarity cuts of form factors encode anomalous dimensions, we show that longer operators are often restricted from renormalizing shorter operators at the first order where Feynman diagrams exist. The theorem applies quite generally and depends only on the field content of the operators involved. We apply our theorem to operators of dimension five through seven in the standard model effective field theory, including examples of nontrivial zeros in the anomalous-dimension matrix at one through four loops. The zeros at two and higher loops go beyond those previously explained using helicity selection rules. We also include explicit sample calculations at two loops.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lattice finite-volume dependence of the nucleon parton distributions

There have been rapid developments in the direct calculation of the Bjorken-x dependence of parton distribution functions (PDFs) using lattice QCD, and the technique shows promising results. Among various new methods, large-momentum effective theory (LaMET), which calculates boosted hadron matrix elements of multiple spatial displacements on the lattice, shows promising PDFs at physical pion mass by both LP 3 and ETMC Collaborations. However, the finite-volume systematics have not yet been studied, and it has been suggested that such systematics can be more significant for LaMET-type operators than the traditional bilinear quark operators in charges and form factors. In this work, we present the first study of the finite-volume systematic for both isovector nucleon unpolarized and helicity matrix elements on three lattice volumes (2.88, 3.84, 4.8 fm) with lattice spacing 0.12 fm and 220-MeV pion mass. We perform two-state simultaneous fits using multiple source-sink separations to remove excited-state contamination and obtain reliable ground-state matrix elements. We then implement nonperturbative renormalization and Fourier transform the matrix elements to momentum-space quasi-PDFs. Overall, we do not see significant finite-volume systematics at the studied boost momenta of P z = 1.3 and 2.6 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Physics Research at Jefferson Lab

The Florida International University (FIU) experimental nuclear physics group consists of four to five faculty, four to eight graduate students, at times one postdoctoral scholar, and several undergraduate students. Our research is mainly conducted at Jefferson Lab's Continuous Electron Accelerator Beam Facility. We are studying the electroprodcution of strangeness and also the interaction of strange baryons, hyperons, with nuclear matter; the effects of two-photon exchange on nuclear form factor measurements; the short range correlations in nuclei; and the production of exotic mesons. Over the entire period of this project, members of the group have been leading the data acquisition and analysis efforts as co-spokespersons of 12 Jefferson Lab experiments, as well as contributed to the efforts of the broader JLab user community. This has resulted in the publication of over 300 papers in peer reviewed journals and conference proceedings. Twelve students received their Ph.D. and four their M.S. based on analysis of data collected during this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multichannel low power time-to-digital converter card with 21 ps precision and full scale range up to 10 μs

We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μs, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-, frequency-, and wavevector-resolved x-ray diffraction from single molecules

Using a quantum electrodynamic framework, we calculate the off-resonant scattering of a broadband X-ray pulse from a sample initially prepared in an arbitrary superposition of electronic states. The signal consists of single-particle (incoherent) and two-particle (coherent) contributions that carry different particle form factors that involve different material transitions. Single-molecule experiments involving incoherent scattering are more influenced by inelastic processes compared to bulk measurements. The conditions under which the technique directly measures charge densities (and can be considered as diffraction) as opposed to correlation functions of the charge-density are specified. The results are illustrated with time- and wavevector-resolved signals from a single amino acid molecule (cysteine) following an impulsive excitation by a stimulated X-ray Raman process resonant with the sulfur K-edge. Our theory and simulations can guide future experimental studies on the structures of nano-particles and proteins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bit Error Rate Performance of a Free Space Optical Link Using Double Clad Fibers

Mobile and embedded applications are emerging in the growing field of free space optical links (FSOL). Some mobile applications for FSOL include spacecraft, aircraft, and automotive. These applications by nature require low size weight and power (SWaP) solutions. The main challenge with any FSOL system is the strict pointing requirements. Common solutions to pointing and alignment of FSOL include gimbals, fast steering mirrors, and adaptive optics. All of which provide viable solutions at the cost of increased SWaP. Previously, we presented the use of both large core fibers and double clad fibers (DCF) to interface FSOL transmit and receive optics with small form factor pluggable optical transceivers (SFP). Double clad fibers have been shown to enable a common optical path by transmitting through a single mode core and receiving through a large inner cladding. This enables a single set of symmetric transmit and receive optics, which decreases the SWaP. In addition, using DCF increases the received power stability of the link relative to a multi-mode fiber (MMF) transmitting. To determine the viability of the system, bit error rate performance needs to be investigated. The results of this paper show that at a bit rate of 10 Gbps, double clad fibers offer similar bit error rate performance to single mode fibers when transmitting and multi-mode fibers when receiving enabling a symmetric duplex FSOL reducing SWaP.

Small Form-Factor Pluggable Optical Transceiver↗

Invariant amplitudes, unpolarized cross sections, and polarization asymmetries in neutrino-nucleon and antineutrino-nucleon elastic scattering

At leading order in weak and electromagnetic couplings, cross sections for (anti)neutrino-nucleon elastic scattering are determined by four nucleon form factors that depend on the momentum transfer Q 2 . Including radiative corrections in the Standard Model and potential new physics contributions beyond the Standard Model, eight invariant amplitudes are possible, depending on both Q 2 and the (anti)neutrino energy E ν . We review the definition of these amplitudes and use them to compute both unpolarized and polarized observables including radiative corrections. We show that unpolarized accelerator neutrino cross-section measurements can probe new physics parameter space within the constraints inferred from precision beta decay measurements. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The optical, vibrational, structural and elasto-optic properties of Zn{sub 0.25}Cd{sub 0.75}S{sub y}Se{sub 1-y} quaternary alloys

The optical, vibrational, structural and elasto-optic properties of quaternary II-VI alloys Zn{sub 0.25}Cd{sub 0.75}S{sub 0.25}Se{sub 0.75}, Zn{sub 0.25}Cd{sub 0.75}S{sub 0.50}Se{sub 0.50} and Zn{sub 0.25}Cd{sub 0.75}S{sub 0.75}Se{sub 0.25} are presented. Within the empirical pseudopotential method (EPM) the disorder effects are modeled via modified virtual crystal approximation (MVCA). The computed bandgaps and the refined form factors are utilized to evaluate optical, vibrational, structural and elasto-optic properties. The refractive index (n), static (ε{sub 0}) and high frequency dielectric (ε{sub ∞}) constants are calculated to reveal optical behavior of alloys. The longitudinal ω{sub LO}(0) and transverse ω{sub TO}(0) optical frequencies are obtained to see vibrational characteristics. Moreover, the elastic constants (c{sub ij}) and bulk moduli (B) are computed by combining the EPM with Harrison bond orbital model. The elasto-optic nature of alloys is examined by computing the photo-elastic constants. These values are significant with regard to the opto-electronic applications especially when no experimental data are available on this system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bit Error Rate Performance of a Free Space Optical Link Using Double Clad Fibers

Mobile and embedded applications are emerging in the growing field of free space optical links (FSOL). Some mobile applications for FSOL include spacecraft, aircraft, and automotive. These applications by nature require low size weight and power (SWaP) solutions. The main challenge with any FSOL system is the strict pointing requirements. Common solutions to pointing and alignment of FSOL include gimbals, fast steering mirrors, and adaptive optics. All of which provide viable solutions at the cost of increased SWaP. Previously, we presented the use of both large core fibers and double clad fibers (DCF) to interface FSOL transmit and receive optics with small form factor pluggable optical transceivers (SFP). Double clad fibers have been shown to enable a common optical path by transmitting through a single mode core and receiving through a large inner cladding. This enables a single set of symmetric transmit and receive optics, which decreases the SWaP. In addition, using DCF increases the received power stability of the link relative to a multi-mode fiber (MMF) transmitting. To determine the viability of the system, bit error rate performance needs to be investigated. The results of this paper show that at a bit rate of 10 Gbps, double clad fibers offer similar bit error rate performance to single mode fibers when transmitting and multi-mode fibers when receiving enabling a symmetric duplex FSOL reducing SWaP.

Double Clad Fiber↗

Energy-momentum tensor in Φ 4 theory at one loop

The energy-momentum tensor form factors are studied in Φ 4 theory to one-loop order with particular focus on the 𝐷-term, a particle property which has attracted a lot of attention in the recent literature. It is shown that the free Klein-Gordon theory value of the 𝐷-term 𝐷 free =−1 is reduced to 𝐷 one-loop =− $\frac{1}{3}$ even if the Φ 4 interaction is infinitesimally small. A companion work in Φ 3 theory confirms this result which may indicate that it is independent of the type of interaction as long as the scalar theory is renormalizable. Dispersion relations are studied. Various definitions of mean square radii including the mechanical radius are investigated. The findings contribute to a better understanding of the energy momentum tensor properties of particles and their interpretation.

form factors↗

Hexagonalization of correlation functions II: two-particle contributions

In this report, we compute one-loop planar five-point functions in N=4 super-Yang-Mills using integrability. As in the previous work, we decompose the correlation functions into hexagon form factors and glue them using the weight factors which depend on the cross-ratios. The main new ingredient in the computation, as compared to the four-point functions studied in the previous paper, is the two-particle mirror contribution. We develop techniques to evaluate it and find agreement with the perturbative results in all the cases we analyzed. In addition, we consider next-to-extremal four-point functions, which are known to be protected, and show that the sum of one-particle and two-particle contributions at one loop adds up to zero as expected. The tools developed in this work would be useful for computing higher-particle contributions which would be relevant for more complicated quantities such as higher-loop corrections and non-planar correlators.

1/N Expansion↗

First Global Extraction of Generalized Parton Distributions from Experiment and Lattice Data with Next-to-Leading-Order Accuracy

We report the first global extraction of generalized parton distributions, GUMP 1.0, by combining deeply virtual Compton scattering and 𝜌-meson production data from Jefferson Lab and the Hadron-Electron Ring Accelerator with global fits of parton distribution functions, charge form factors, and lattice quantum chromodynamics simulations. Using a conformal moment space parametrization, we achieve a unified description across low- and high-𝑥 regions at next to leading order accuracy in perturbative corrections. The results provide state-of-the-art generalized parton distributions consistent with almost all known facts, enabling three-dimensional nucleon imaging in impact parameter space and, at the same time, establishing a benchmark for future theoretical and experimental studies of the nucleon structure.

Form factors↗

Determination of transition metal ion distribution in cubic spinel Co{sub 1.5}Fe{sub 1.5}O{sub 4} using anomalous x-ray diffraction

We report anomalous x-ray diffraction studies on Co ferrite with composition Co{sub 1.5}Fe{sub 1.5}O{sub 4} to obtain the distribution of transition metal ions in tetrahedral and octahedral sites. We synthesize spinel oxide (Co{sub 1.5}Fe{sub 1.5}O{sub 4}) through co-precipitation and subsequent annealing route. The imaginary part (absorption) of the energy dependent anomalous form factor is measured and the real part is calculated theoretically through Kramers–Krönig transformation to analyze anomalous x-ray diffraction peak intensities. Fe and Co K-edge x-ray absorption near edge structure (XANES) spectra are used to estimate charge states of transition metals. Our analysis, within experimental errors, suggests 44% of the tetrahedral sites contain Co in +2 oxidation state and the rest 56% sites contain Fe in +2 and +3 oxidation states. Similarly, 47% of the octahedral sites contain Fe in +3 oxidation states, whereas, the rest of the sites contain Co in +2 and +3 oxidation states. While a distinct pre-edge feature in the Fe K-edge XANES is observed, Co pre-edge remains featureless. Implications of these results to magnetism are briefly discussed.

36 MATERIALS SCIENCE↗

Versatile common instrumentation for optical detection of pH and dissolved oxygen

The recent trend toward use of disposable and miniature bioreactors requires the use of appropriate sensors. pH and dissolved oxygen (DO) are often measured using optical chemical sensors due to their small form factor and convenience in use. These sensors are often interrogated using a specialized opto-electronic transducer that is designed around the optical sensor. In this contribution, we are presenting a new class of opto-electronic transducers that are usable with several different chemical sensors without the need to switch the optics or hardware when changing the type of the chemical sensor. This allows flexibility closer to the lab-grade devices while the size is closer to a dedicated sensor. This versatile instrumentation is capable of seamlessly switching between the pH and DO measurement modes and is capable of auto recognition of the sensor type. The principle of ratiometric fluorescence is used for pH measurements, and that of fluorescence lifetime for DO measurements. An approach to obtain identical calibrations between several devices is also presented. The described hardware constitutes common instrumentation for measuring either pH or DO and has been tested in actual bioprocesses. It has been found adequate for continuous bioprocess monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗