Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Accuracy optimized neural networks do not effectively model optic flow tuning in brain area MSTd

Accuracy-optimized convolutional neural networks (CNNs) have emerged as highly effective models at predicting neural responses in brain areas along the primate ventral stream, but it is largely unknown whether they effectively model neurons in the complementary primate dorsal stream. We explored how well CNNs model the optic flow tuning properties of neurons in dorsal area MSTd and we compared our results with the Non-Negative Matrix Factorization (NNMF) model, which successfully models many tuning properties of MSTd neurons. To better understand the role of computational properties in the NNMF model that give rise to optic flow tuning that resembles that of MSTd neurons, we created additional CNN model variants that implement key NNMF constraints – non-negative weights and sparse coding of optic flow. While the CNNs and NNMF models both accurately estimate the observer's self-motion from purely translational or rotational optic flow, NNMF and the CNNs with nonnegative weights yield substantially less accurate estimates than the other CNNs when tested on more complex optic flow that combines observer translation and rotation. Despite its poor accuracy, NNMF gives rise to tuning properties that align more closely with those observed in primate MSTd than any of the accuracy-optimized CNNs. This work offers a step toward a deeper understanding of the computational properties and constraints that describe the optic flow tuning of primate area MSTd.

60 APPLIED LIFE SCIENCES↗

Experimental and Simulation Analysis of Binary Mixtures of Biomass and Inert Material

A literature review was conducted to identify experiments on various scales of biomass combustion specific to circulating fluidized bed (CFB) combustors. Typical feedstock and inert bed material characteristics for biomass combustion in a CFB were gathered. This information was used to design laboratory-scale, non-reacting experiments on biomass-inert bed material mixtures in a 1-in. cylindrical test rig in the Multiphase Flow Analysis Laboratory (MFAL) in Morgantown, WV. The biomass chosen was a hardwood. Pellets from the hardwood were milled and sieved to obtain three size ranges—small, medium, and large. Three mass loadings of each of the biomass samples were fluidized with glass beads as the inert bed material to study the mixing characteristics under varying fluidizing gas velocities. Hydrodynamic data including pressure drop measurements at select vertical locations and video recordings of the mixture behavior were generated in this effort.

09 BIOMASS FUELS↗

Experimental Activities with the IELLLO Lithium-Lead Facility

Fusion power offers the prospect of an almost inexhaustible source of energy for future generations. Although this may be true, it also presents so far serious scientific and engineering challenges. Breeding Blanket is one of key components of future fusion reactors, since it directly involves tritium breeding and energy extraction, both of them critical to development of fusion power. To deal with the development of Breeding Blankets, ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development) designed and built a lead lithium loop (IELLLO: Integrated European Lead Lithium Loop): the experiment aims to support R and D activities for the conceptual and preliminary design of the European test blanket systems. IELLLO was completed, installed and operated at ENEA Brasimone Research Centre. The purpose of this work is to describe the experimental activities that have been carried out concerning the qualification of the facility, and relative instrumentations, for lead lithium applications. A series of thermo-hydraulic investigations on IELLLO facility has been elaborated: lead lithium pressure transducers, heat exchanger, permanent magnet pumping system, mass flow meters and air cooler have been tested. The absolute pressure meter in contact with Pb-16Li was qualified in pressure range up to 10 bar and temperature up to 400 deg. C. The installation of new kinds of Pb-16Li differential pressure transducers will allow to check the pump characteristic curve and accurately calculate valves pressure drops. These factors could give a better information for the thermo-hydraulic qualification of the facility. Vortex Mass Flow Meter has shown good results in terms of accuracy. The performance has been validated by thermal balance with a dedicated heating system. Nevertheless, the installations of different types of mass flow meters will enable to test IELLLO at ITER relevant conditions, and at lower mass flow rates than those tested up to now. The new pumping system with a PM Pump, was qualified for the first time in Pb-16Li, and the procedure for the operation and maintenance of the pump was developed. The pump is able to supply a mass flow rate in the range from 1.2 to 2.4 kg/s with a temperature of Pb-16Li up to 550 deg. C in the test section. Significant results have been obtained also for the heat exchanger, which has shown high efficiencies, even more than expected. Likewise, the Air Cooler has been verified to be able to cool Pb-16Li in a relatively short time, even at the worst temperature and mass flow conditions. (authors)

42 ENGINEERING↗

Role of electric charge in shaping equilibrium configurations of fluid tori encircling black holes

Astrophysical fluids may acquire nonzero electrical charge because of strong irradiation or charge separation in a magnetic field. In this case, electromagnetic and gravitational forces may act together and produce new equilibrium configurations, which are different from the uncharged ones. Following our previous studies of charged test particles and uncharged perfect fluid tori encircling compact objects, we introduce here a simple test model of a charged perfect fluid torus in strong gravitational and electromagnetic fields. In contrast to ideal magnetohydrodynamic models, we consider here the opposite limit of negligible conductivity, where the charges are tied completely to the moving matter. This is an extreme limiting case which can provide a useful reference against which to compare subsequent more complicated astrophysically motivated calculations. To clearly demonstrate the features of our model, we construct three-dimensional axisymmetric charged toroidal configurations around Reissner-Nordstroem black holes and compare them with equivalent configurations of electrically neutral tori.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A kW-scale, 24-hour continuously operational, radiative sky cooling system: Experimental demonstration and predictive modeling

With the advancement in sub-ambient cooling of water during daytime under the sun with scalable-manufactured radiative cooling metamaterials, the challenge for applications lies in design and building of large-scale radiative cooling systems. Here, we present a kW-scale, 24-hour continuously operational, radiative sky cooling system, with both experimental study and detailed modeling. We first quantitatively show how water flow rate directly affects the system cooling power and inversely affects the water temperature drop. A day-and-night stagnant (flow rate = 0 L/(min·m 2 )) water cooling test of the system shows a consistent sub-ambient water temperature drop of 5–7 °C. A daytime cooling test of the system at a low flow rate of 0.227 L/(min·m 2 ) yields a maximum sub-ambient temperature drop of 4.0 °C with an average net cooling power of around 80 W/m 2 . Further modelling for a typical metrological year (in Phoenix, Arizona) shows that the system could generate as much as 350 kWh cold (or 26 kWh/m 2 ) with a sub-ambient temperature drop of 4–5 °C at a low flow rate of 0.1 L/(min·m 2 ) during a typical summer month. The cold generated could be used to assist AC systems in regions or seasons with high ambient temperatures.

30 DIRECT ENERGY CONVERSION↗

Thermoelectric Magnetohydrodynamic Stirring of Liquid Metals

The direct observation of a thermoelectric magnetohydrodynamic (TEMHD) flow has been achieved and is reported here. The origin of the flow is identified based on a series of qualitative tests and corresponds, quantitatively, with a swirling flow TEMHD model. A theory for determining the dominant driver of a free-surface flow, TEMHD or thermocapillary (TC), is found to be consistent with the experimental results. The use of the analytical form for an open geometry develops a new dimensionless parameter describing the ratio of TEMHD to TC generated flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of copper chloride-impregnated sorbents on mercury vapor control in an entrained-flow reactor system

An entrained-flow system has been designed and constructed to simulate in-flight mercury (Hg) capture by sorbent injection in ducts of coal-fired utility plants. The test conditions of 1.2-sec residence time, 140{degree}C gas temperature, 6.7 m/sec (22 ft/sec) gas velocity, and 0-0.24 g/m{sup 3} (0-15 lbs of sorbent per 1 million actual cubic feet of flue gas sorbent injection rates were chosen to simulate conditions in the ducts. Four kinds of sorbents were used in this study. Darco Hg-LH (lignite-based) served as a benchmark sorbent with which Hg control capability of other sorbents could be compared. Also, Darco-FGD (lignite-based) was used as a representative raw activated carbon sorbent. Two different copper chloride-impregnated sorbents were developed in the laboratory and tested in the entrained-flow system to examine the possibility of using these sorbents at coal-fired power plants. The test results showed that one of the copper chloride sorbents has remarkable elemental mercury (Hg{sup 0}) oxidation capability, and the other sorbent demonstrated a better performance in Hg removal than Darco Hg-LH. 13 refs., 4 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Turbulent heat transfer enhancement by counter/co-swirling flow in a tube fitted with twin twisted tapes

In the present study, the influences of twin-counter/co-twisted tapes (counter/co-swirl tape) on heat transfer rate (Nu), friction factor (f) and thermal enhancement index ({eta}) are experimentally determined. The twin counter twisted tapes (CTs) are used as counter-swirl flow generators while twin co-twisted tapes (CoTs) are used as co-swirl flow generators in a test section. The tests are conducted using the CTs and CoTs with four different twist ratios (y/w = 2.5, 3.0, 3.5 and 4.0) for Reynolds numbers range between 3700 and 21,000 under uniform heat flux conditions. The experiments using the single twisted tape (ST) are also performed under similar operation test conditions, for comparison. The experimental results demonstrate that Nusselt number (Nu), friction factor (f) and thermal enhancement index ({eta}) increase with decreasing twist ratio (y/w). The results also show that the CTs are more efficient than the CoTs for heat transfer enhancement. In the range of the present work, heat transfer rates in the tube fitted with the CTs are around 12.5-44.5% and 17.8-50% higher than those with the CoTs and ST, respectively. The maximum thermal enhancement indices ({eta}) obtained at the constant pumping power by the CTs with y/w = 2.5, 3.0, 3.5 and 4.0, are 1.39, 1.24, 1.12 and 1.03, respectively, while those obtained by using the CoTs with the same range of y/w are 1.1, 1.03, 0.97 and 0.92, respectively. In addition, the empirical correlations of the heat transfer (Nu), friction factor (f) and thermal enhancement index ({eta}) are also reported. (author)

42 ENGINEERING↗

Development of Electrical Capacitance Sensors for Accident Tolerant Fuel (ATF) Testing at the Transient Reactor Test (TREAT) Facility

A variety of instruments are being developed and qualified to support the Accident Tolerant Fuels (ATF) program and future transient irradiations at the Transient Reactor Test (TREAT) facility at Idaho National Laboratory (INL). The University of New Mexico (UNM) is working with INL to develop capacitance-based void sensors for determining the timing of critical boiling phenomena in static capsule fuel testing and the volume-averaged void fraction in flow-boiling in-pile water loop fuel testing. The static capsule sensor developed at INL is a plate-type configuration, while UNM is utilizing a ring-type capacitance sensor. Each sensor design has been theoretically and experimentally investigated at INL and UNM. Experiments are being performed at INL in an autoclave to investigate the performance of these sensors under representative Pressurized Water Reactor (PWR) conditions in a static capsule. Experiments have been performed at UNM using air-water two-phase flow to determine the sensitivity and time response of the capacitance sensor under a flow boiling configuration. Initial measurements from the capacitance sensor have demonstrated the validity of the concept to enable real-time measurement of void fraction. The next steps include designing the cabling interface with the flow loop at UNM for Reactivity Initiated Accident (RIA) ATF testing at TREAT and further characterization of the measurement response for each sensor under varying conditions by experiments and modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of DNB Predictive Capability in Multiphase Boiling Model of STAR-CCM+

The current milestone report is to evaluate the predictive capability of the existing boiling model in the commercial Computational Fluid Dynamics (CFD) package (so called, STARCCM+ 11.04.012), and validate the numerical calculation of a boiling curve with identification of departure from nucleate boiling (DNB) point by comparing with experimental measurements in the literatures. The current work directly demonstrates the DNB predictive capability in multiphase boiling model for nuclear reactor applications, which is tightly coupled with the CASL mission goal and evolving need from the nuclear industry. The boiling model tested here is based on the heat flux partitioning RPI approach (so called Generation-I boiling model in STAR-CCM+). A traditional experimental DNB test with a vertical pipe flow performed by Argonne National Laboratory (ANL), and a realistic 5x5-bundle fuel bundle with non-mixing vane DNB test conducted by Westinghouse Electric Company (WEC) are selected as reference experimental measurement. A baseline DNB simulation methodology is reported and its predictive capability is evaluated qualitatively as well as quantitatively with existing experiments. A parametric study of the microscopic boiling closure relations is investigated. For the pipe flow DNB validation study, the calculated DNB from the current study demonstrates good agreement with measured DNB data. The maximum deviation is observed less than 20%. The trend behaviors of DNB in varying operating conditions are similar with the observation reported in the literature. In addition, a meshing strategy for 5x5 bundle case is reported, some challenges on 5x5 bundle DNB model are also discussed. The current study provide a fundamental insight on the usefulness and limitations of the generation-I boiling model approach and may contribute to an advanced boiling model development for a practical nuclear thermal hydraulic application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of experimental and numerical studies of the performance characteristics of a pumped counterflow virtual impactor

Experiments and Computational Fluid Dynamic (CFD) simulations were performed to evaluate the performance characteristics of a Pumped Counterflow Virtual Impactor (PCVI). Tests were conducted for various flow configurations for which the diameter at which 50% of the particles were transmitted was determined. Experimentally determined 50% cutpoints varied from 2.2 to 4.8 micrometers and CFD predicted diameters agreed within ± 0.4 microns. Both experimental and CFD results showed similar transmission efficiency (TE) curves. CFD TE was always greater than experimental results, most likely due to impaction losses in fittings not included in the simulations. Ideal transmission, corresponding to 100% TE, was never realized in either case due to impaction losses and small scale flow features such as eddies. Areas where CFD simulations showed such flow recirculation zones were also found to be the locations where particulate residue was deposited during experiments. CFD parametric tests showed that PCVI performance can be affected by the nozzle geometry and misalignment between the nozzle and collector orifice. We conclude that CFD can be used with confidence for counterflow virtual impactor (CVI) design. Modifications to improve the performance characteristics of the PCVI are suggested.

42 ENGINEERING↗

Heat transfer coefficients of shell and coiled tube heat exchangers

In the present study, the heat transfer coefficients of shell and helically coiled tube heat exchangers were investigated experimentally. Three heat exchangers with different coil pitches were selected as test section for both parallel-flow and counter-flow configurations. All the required parameters like inlet and outlet temperatures of tube-side and shell-side fluids, flow rate of fluids, etc. were measured using appropriate instruments. Totally, 75 test runs were performed from which the tube-side and shell-side heat transfer coefficients were calculated. Empirical correlations were proposed for shell-side and tube-side. The calculated heat transfer coefficients of tube-side were also compared to the existing correlations for other boundary conditions and a reasonable agreement was observed. (author)

42 ENGINEERING↗

SDI CFD MODELING ANALYSIS

The Savannah River Remediation (SRR) Organization requested that Savannah River National Laboratory (SRNL) develop a Computational Fluid Dynamics (CFD) method to mix and blend the miscible contents of the blend tanks to ensure the contents are properly blended before they are transferred from the blend tank; such as, Tank 50H, to the Salt Waste Processing Facility (SWPF) feed tank. The work described here consists of two modeling areas. They are the mixing modeling analysis during miscible liquid blending operation, and the flow pattern analysis during transfer operation of the blended liquid. The transient CFD governing equations consisting of three momentum equations, one mass balance, two turbulence transport equations for kinetic energy and dissipation rate, and one species transport were solved by an iterative technique until the species concentrations of tank fluid were in equilibrium. The steady-state flow solutions for the entire tank fluid were used for flow pattern analysis, for velocity scaling analysis, and the initial conditions for transient blending calculations. A series of the modeling calculations were performed to estimate the blending times for various jet flow conditions, and to investigate the impact of the cooling coils on the blending time of the tank contents. The modeling results were benchmarked against the pilot scale test results. All of the flow and mixing models were performed with the nozzles installed at the mid-elevation, and parallel to the tank wall. From the CFD modeling calculations, the main results are summarized as follows: (1) The benchmark analyses for the CFD flow velocity and blending models demonstrate their consistency with Engineering Development Laboratory (EDL) and literature test results in terms of local velocity measurements and experimental observations. Thus, an application of the established criterion to SRS full scale tank will provide a better, physically-based estimate of the required mixing time, and elevation of transfer pump for minimum sludge disturbance. (2) An empirical equation for a tank with no cooling coils agrees reasonably with the current modeling results for the dual jet. (3) From the sensitivity study of the cooling coils, it was found that the tank mixing time for the coiled tank was about two times longer than that of the tank fluid with no coils under the 1/10th scale, while the coiled tank required only 50% longer than the one without coils under the full scale Tank 50H. In addition, the time difference is reduced when the pumping U{sub o}d{sub o} value is increased for a given tank. (4) The blending time for T-shape dual jet pump is about 20% longer than that of 15{sup o} upward V-shape pump under the 1/10th pilot-scale tank, while the time difference between the two pumps is about 12% for the full-scale Tank 50H. These results are consistent with the literature information. (5) A transfer pump with a solid-plate suction screen operating at 130 gpm can be located 9.5 inches above settled sludge for 2 in screen height in a 85 ft waste tank without disturbing any sludge. Detailed results are summarized in Table 13. Final pump performance calculations were made by using the established CW pump design, and operating conditions to satisfy the two requirements of minimum sludge disturbance, and adequate blending of tank contents. The final calculation results show that the blending times for the coiled and uncoiled tanks coupled with the CW pump design are 159 and 83 minutes, respectively. All the results are provided in Table 16.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effectiveness of Cool Roof Coatings with Ceramic Particles

Liquid applied coatings promoted as cool roof coatings, including several with ceramic particles, were tested at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tenn., for the purpose of quantifying their thermal performances. Solar reflectance measurements were made for new samples and aged samples using a portable reflectometer (ASTM C1549, Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer) and for new samples using the integrating spheres method (ASTM E903, Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres). Thermal emittance was measured for the new samples using a portable emissometer (ASTM C1371, Standard Test Method for Determination of Emittance of Materials Near Room 1 Proceedings of the 2011 International Roofing Symposium Temperature Using Portable Emissometers). Thermal conductivity of the coatings was measured using a FOX 304 heat flow meter (ASTM C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus). The surface properties of the cool roof coatings had higher solar reflectance than the reference black and white material, but there were no significant differences among coatings with and without ceramics. The coatings were applied to EPDM (ethylene propylene diene monomer) membranes and installed on the Roof Thermal Research Apparatus (RTRA), an instrumented facility at ORNL for testing roofs. Roof temperatures and heat flux through the roof were obtained for a year of exposure in east Tennessee. The field tests showed significant reduction in cooling required compared with the black reference roof (~80 percent) and a modest reduction in cooling compared with the white reference roof (~33 percent). The coating material with the highest solar reflectivity (no ceramic particles) demonstrated the best overall thermal performance (combination of reducing the cooling load cost and not incurring a large heating penalty cost) and suggests solar reflectivity is the significant characteristic for selecting cool roof coatings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Evaluating next-generation intensity–duration–frequency curves for design flood estimates in the snow-dominated western United States

Civil infrastructure such as culverts and bridges are commonly designed using precipitation-based intensity-duration-frequency (PREC-IDF) curves, which assume that the occurrence of precipitation is in the form of rainfall and immediately available for the rainfall-runoff process. In snow-dominated regions, where most winter precipitation occurs as snow that melts during spring to early summer, the use of standard PREC-IDF curves may lead to substantial underestimation of design floods and high failure risk of infrastructure. In this context, we developed next-generation IDF (NG-IDF) curves that characterize the actual water reaching the land surface (i.e., rainfall plus snowmelt) to enhance standard infrastructure design in snow-dominated regions. This study evaluates the performance of NG-IDF curves coupled with U.S. Department of Agriculture Technical Release 55 hydrologic model in estimating design floods for 246 snowy locations in different hydroclimate regimes of the western United States. Design flood estimates from a well-validated continuous simulation using a physics-based hydrologic model, the Distributed Hydrology Soil Vegetation Model (DHSVM), were used as the performance benchmark. Compared with the benchmark estimates, the standard PREC-IDF curves led to substantial errors in design flood estimates while the NG-IDF curves significantly reduced these errors. For example, the averaged error in the 50-year design flood estimates over the 246 locations was reduced from 31% with the use of PREC-IDF curves to 12% with the use of NG-IDF curves. Despite the different model structures, the single-event NG-IDF approach versus the continuous simulation DHSVM did not exhibit statistically significant differences in 91% of the 246 locations for the 50-year design flood estimates. We find this indicates a satisfactory performance of NG-IDF curves to estimate design flow under the conditions tested in the snow-dominated western United States. This article also presents technical suggestions and the limitations of infrastructure design using NG-IDF curves for regulatory agencies and practicing engineers.

54 ENVIRONMENTAL SCIENCES↗