Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fire effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Super-Zip separation joint performance investigation

Following functional failures of two of five Lockheed Super-Zip spacecraft separation joints in a development test series to quantify thermal effects, an investigation program was initiated on this and related systems to assist in preventing recurrence. The Super-Zip joint, applied in a ring configuration, utilizes an explosively expanded tube to fracture surrounding prenotched aluminum plates to achieve planar separation. A unique test method was developed and more than 300 individual test firings were conducted to provide an understanding of severance mechanisms, the functional performance effects of system variables, and the most likely cause of system failure. An approach for defining functional margin was developed, as well as specific recommendations for improving existing and future systems.

Bement, Laurence J.↗

RS-25 for the NASA Cargo Launch Vehicle: The Evolution of SSME for Space Exploration

A key element of the National Vision for Space Exploration is the development of a heavy-lift Cargo Launch Vehicle (CaLV). Missions to the Moon, Mars, and beyond are only possible with the logistical capacity of putting large payloads in low-earth orbit. However, beyond simple logistics, there exists the need for this capability to be as cost effective as possible to ensure mission sustainability. An element of the CaLV project is, therefore, the development of the RS-25, which represents the evolution of the proven Space Shuttle Main Engine (SSME) into a high-performance, cost-effective expendable rocket engine. The development of the RS-25 will be built upon the foundation of over one million seconds of accumulated hot-fire time on the SSME. Yet in order to transform the reusable SSME into the more cost-effective, expendable RS-25 changes will have to be made. Thus the project will inevitably strive to maintain a balance between demonstrated heritage products and processes and the utilization of newer technology developments. Towards that end, the Core Stage Engine Office has been established at the NASA Marshall Space Flight Center to initiate the design and development of the RS-25 engine. This paper is being written very early in the formulation phase of the RS-25 project. Therefore the focus of this paper will be to present the scope, challenges, and opportunities for the RS-25 project. Early schedules and development decisions and plans will be explained. For not only must the RS-25 project achieve cost effectiveness through the development of new, evolved components such as a channel-wall nozzle, a new HIP-bonded main combustion chamber, and several others, it must simultaneously develop the means whereby this engine can be manufactured on a scale never envisioned for the SSME. Thus, while the overall project will span the next eight to ten years, there is little doubt that even this schedule is aggressive with a great deal of work to accomplish.

Kynard, Michael H.↗

Simulating Surface and Subsurface Water Balance Changes Due to Burn Severity

Forest fires have a significant impact on hydrology, such as reduced infiltration rates leading to increased flooding. However, post-fire water balance changes and the competing hydrologic response of increased runoff and evapotranspiration as a function of burn severity are not well understood. Comparing pre- and post-fire water balance changes is challenging because measurements of fire-disturbed landscapes with the previously undisturbed character are impractical due to non-repetitive observational conditions. We used a physically based modeling experiment to incorporate burn severity data from the Las Conchas fire to approximate model parameterization to evaluate continuous water balance progression for pre- and post-fire simulations using the same forcing conditions. Fire disturbance decreased evapotranspiration and increased overland flow response to precipitation events. The reduction of evapotranspiration often dominated the new water balance compared with the increase in overland flow, resulting in higher soil moisture. However, this modeling experiment also identified a tipping point where increased overland flow from high burn severity sites eclipses the effect of reduced evapotranspiration on the water balance, causing comparatively drier post-fire soils. In particular, high burn severity sites approach a threshold that results in larger changes to overland flow than changes in evapotranspiration, potentially moving the site to an overland flow dominated regime. The shifts in water balance components have implications for how site conditions will change under a range of burn severity scenarios.

54 ENVIRONMENTAL SCIENCES↗

The effects of sulfate and soot in smoke on atmospheric extinction

There was a big forest fire in Northeastern China in May, 1987. An apparently new aerosol layer was detected at the base of the stratosphere. The fire burned from about 6 to 28 May 1987 and produced extensive clouds of smoke that were tracked for thousands of kilometers using NOAA weather satellite imagery. It was found that during and just after this fire, the concentration of particles in the upper tropopause and lower stratosphere above the Pacific Ocean and North America increased as much as 10 times normal concentrations. The increase of the atmospheric extinction coefficient was contributed mostly by sulfates and soot resulting from biomass burning and coal combustion. It was shown that their contributions can reach 80 to 90 percent of the whole extinction coefficient. The forest fire can inject smoke high into the atmosphere, resulting in an increase in atmospheric extinction that might lead to a climate perturbation.

Su, Weihan↗

Validation and Simulation of Ares I Scale Model Acoustic Test - 2 - Simulations at 5 Foot Elevation for Evaluation of Launch Mount Effects

The Ares I Scale Model Acoustics Test (ASMAT) is a series of live-fire tests of scaled rocket motors meant to simulate the conditions of the Ares I launch configuration. These tests have provided a well documented set of high fidelity measurements useful for validation including data taken over a range of test conditions and containing phenomena like Ignition Over-Pressure and water suppression of acoustics. Expanding from initial simulations of the ASMAT setup in a held down configuration, simulations have been performed using the Loci/CHEM computational fluid dynamics software for ASMAT tests of the vehicle at 5 ft. elevation (100 ft. real vehicle elevation) with worst case drift in the direction of the launch tower. These tests have been performed without water suppression and have compared the acoustic emissions for launch structures with and without launch mounts. In addition, simulation results have also been compared to acoustic and imagery data collected from similar live-fire tests to assess the accuracy of the simulations. Simulations have shown a marked change in the pattern of emissions after removal of the launch mount with a reduction in the overall acoustic environment experienced by the vehicle and the formation of highly directed acoustic waves moving across the platform deck. Comparisons of simulation results to live-fire test data showed good amplitude and temporal correlation and imagery comparisons over the visible and infrared wavelengths showed qualitative capture of all plume and pressure wave evolution features.

Strutzenberg, Louise L.↗

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The violence of reaction from a fast projectile fired into heated PBX 9502

The shock sensitivity of hot PBX 9502 is of concern in abnormal combined insult situations. A series of fragment impacts into thin aluminum cased PBX 9502 heated to various temperatures was performed. The explosive was tightly radially confined but effectively unconfined axially. A 15.5 mm diameter by 3 mm thick heavy tungsten fragment (17.5 g/cc) fired at a velocity of approximately 1.4 km s –1 imparted an initial shock pressure of ≈15 GPa into the explosive. Under one dimensional shock conditions, the run to detonation in PBX 9502 at ambient temperature and at this pressure is ≈5 mm, however, given the small dimensions of the fragment in this insult, the pressure is quickly released from the edge so that a dying reaction is created. The situation is very different at higher explosive temperatures when the shock sensitivity of lightly confined PBX 9502 is much greater. Under these specific insult conditions, detonations were not observed at 22 and 70°C, but were observed at 170 and 108°C. The significance of these results is discussed.

36 MATERIALS SCIENCE↗

Material Ignition and Suppression Test (MIST) in Space Exploration Atmospheres, Summary of Research

The Material Ignition and Suppression Test (MIST) project has had the objective of evaluating the ease of ignition and the fire suppression of materials used in spacecraft under environmental condition expected in a spacecraft. For this purpose, an experimental and theoretical research program is being conducted on the effect of space exploration atmospheres (SEA) on the piloted ignition of representative combustible materials, and on their fire suppression characteristics. The experimental apparatus and test methodology is derived from the Forced Ignition and Flame Spread Test (FIST), a well-developed bench scale test designed to extract material properties relevant to prediction of material flammability. In the FIST test, materials are exposed to an external radiant flux and the ignition delay and critical mass flux at ignition are determined as a function of the type of material and environmental conditions. In the original MIST design, a small-scale cylindrical flow duct with fuel samples attached to its inside wall was heated by a cylindrical heater located at the central axis of the cylinder. However, as the project evolved it was decided by NASA that it would be better to produce an experimental design that could accommodate other experiments with different experimental concepts. Based on those instructions and input from the requirements of other researchers that may share the hardware in an ISS/CIR experiment, a cylindrical design based on placing the sample at the center of an optically transparent tube with heaters equally spaced along the exterior of the cylinder was developed. Piloted ignition is attained by a hot wire igniter downstream of the fuel sample. Environment variables that can be studied via this experimental apparatus include: external radiant flux, oxidizer oxygen concentration, flow velocity, ambient pressure, and gravity level (if flown in the ISS/CIR). This constitutes the current experimental design, which maintains fairly good consistency with Dr Tien's and Dr Olson's project approaches. A further goal of the project has been to develop a combined solid/gas phase numerical model based on the MIST test methodology to predict the flammability behavior of practical materials in spacecraft.

flammability↗

Commercially available CO{sub 2} capture technology

While many CO{sub 2} removal technologies are being researched through laboratory and pilot-scale testing, an existing technology has a significant operating history at commercial-scale facilities, where it is collecting CO{sub 2} from multiple sources, including low-CO{sub 2} concentration flue gas with high oxygen concentrations. This is an advanced amine-based post-combustion CO{sub 2} capture technology developed by Fluor called Ecoamine FG Plus (EFG+). This has been successfully applied at a natural gas-fired power plant at the Bellingham Energy Centre in Massachusetts. EFG+ technology is a cost effective process for removing CO{sub 2} from low pressure, oxygen-containing flue gas. FLuor and E.ON Energie AG are developing a pilot plant which will begin operation in 2010 at E.ON's coal-fired power plant in Wilhelmshaven, Germany. 4 figs.

01 COAL, LIGNITE, AND PEAT↗

Enhancement of mercury capture by the simultaneous addition of hydrogen bromide (HBr) and fly ashes in a slipstream facility

Low halogen content in tested Powder River Basin (PRB) coals and low loss of ignition content (LOI) in PRB-derived fly ash were likely responsible for higher elemental mercury content (averaging about 75%) in the flue gas and also lower mercury capture efficiency by electrostatic precipitator (ESP) and wet-FGD. To develop a cost-effective approach to mercury capture in a full-scale coal-fired utility boiler burning PRB coal, experiments were conducted adding hydrogen bromide (HBr) or simultaneously adding HBr and selected fly ashes in a slipstream reactor (0.152 x 0.152 m) under real flue gas conditions. The residence time of the flue gas inside the reactor was about 1.4 s. The average temperature of the slipstream reactor was controlled at about 155{sup o}C. Tests were organized into two phases. In Phase 1, only HBr was added to the slipstream reactor, and in Phase 2, HBr and selected fly ash were added simultaneously. HBr injection was effective (>90%) for mercury oxidation at a low temperature (155{sup o}C) with an HBr addition concentration of about 4 ppm in the flue gas. Additionally, injected HBr enhanced mercury capture by PRB fly ash in the low-temperature range. The mercury capture efficiency, at testing conditions of the slipstream reactor, reached about 50% at an HBr injection concentration of 4 ppm in the flue gas. Compared to only the addition of HBr, simultaneously adding bituminous-derived fly ash in a minimum amount (30 lb/MMacf), together with HBr injection at 4 ppm, could increase mercury capture efficiency by 30%. Injection of lignite-derived fly ash at 30 lb/MMacf could achieve even higher mercury removal efficiency (an additional 35% mercury capture efficiency compared to HBR addition alone). 25 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Hydrocarbon concentrations in fire toxicity tests as an indication of flash fire propensity

The concentrations of hydrocarbons in the gases from fire toxicity tests are often determined to obtain an indication of their contribution to toxic effects and of the mechanisms of thermal decomposition. Because the gas compositions produced in the University of San Francisco/NASA toxicity screening test are generated under identical pyrolysis conditions, they offer the potential of comparing the flash-fire propensity of various materials.

Hilado, C. J.↗

Experimental fire increases soil carbon dioxide efflux in a grassland long‐term multifactor global change experiment

Abstract Numerous studies have demonstrated that soil respiration rates increase under experimental warming, although the long‐term, multiyear dynamics of this feedback are not well constrained. Less is known about the effects of single, punctuated events in combination with other longer‐duration anthropogenic influences on the dynamics of soil carbon (C) loss. In 2012 and 2013, we assessed the effects of decadal‐scale anthropogenic global change – warming, increased nitrogen (N) deposition, elevated carbon dioxide ( CO 2 ), and increased precipitation – on soil respiration rates in an annual‐dominated Mediterranean grassland. We also investigated how controlled fire and an artificial wet‐up event, in combination with exposure to the longer‐duration anthropogenic global change factors, influenced the dynamics of C cycling in this system. Decade‐duration surface soil warming (1–2 °C) had no effect on soil respiration rates, while +N addition and elevated CO 2 concentrations increased growing‐season soil CO 2 efflux rates by increasing annual aboveground net primary production ( NPP ) and belowground fine root production, respectively. Low‐intensity experimental fire significantly elevated soil CO 2 efflux rates in the next growing season. Based on mixed‐effects modeling and structural equation modeling, low‐intensity fire increased growing‐season soil respiration rates through a combination of three mechanisms: large increases in soil temperature (3–5 °C), significant increases in fine root production, and elevated aboveground NPP . Our study shows that in ecosystems where soil respiration has acclimated to moderate warming, further increases in soil temperature can stimulate greater soil CO 2 efflux. We also demonstrate that punctuated short‐duration events such as fire can influence soil C dynamics with implications for both the parameterization of earth system models ( ESM s) and the implementation of climate change mitigation policies that involve land‐sector C accounting.

Strong, Aaron L.↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Spray automated balancing of rotors - How process parameters influence performance

This paper addresses the application of spray-automated balancing of rotors, and the influence that various operating parameters will have on balancing performance. Spray-automated balancing uses the fuel-air repetitive explosion process to imbed short, discrete bursts of high velocity, high temperature powder into a rotating part at an angle selected to reduce unbalance of the part. The shortness of the burst, the delay in firing of the gun, the speed of the disk and the variability in speed all influence the accuracy and effectiveness of the automated balancing process. The paper evaluates this influence by developing an analytical framework and supplementing the analysis with empirical data obtained while firing the gun at a rotating disk. Encouraging results are obtained, and it is shown that the process should perform satisfactorily over a wide range of operating parameters. Further experimental results demonstrate the ability of the method to reduce vibration levels induced by mass unbalance in a rotating disk.

Smalley, A. J.↗

Fire and Drought Affect Multiple Aspects of Diversity in a Migratory Bird Stopover Community

Drought and high-severity, stand-replacing wildfires can have substantial impacts on the composition of avian communities, including stop-over communities during migration. An inextricable link exists between drought and wildfire, each operating and impacting across different timescales. Many studies have found nonlinear avian abundance trends in breeding community time series data that include pre- and post-fire observations, describing an initial decrease in abundance followed by rapid increases that can attenuate over time. Here, we use a fall bird-banding dataset to evaluate shifts in a drought-impacted avian community following wildfire from taxonomic, functional, and phylogenetic perspectives. We looked at the community as a whole and also categorized birds as residents, migrants, and breeders to assess potential varying responses at the study site. We observed post-fire shifts in functional and phylogenetic diversity that corresponded to changes in vegetation. An influx of migratory insectivores post-fire drove much of the variation between pre- and post-fire avian communities and toward a more related, less phylogenetically dispersed community. A concurrent monsoon season drought was also associated with functional and phylogenetic diversity, highlighting the intertwined pulse press effects on avian communities. Overall, our results suggest that, although bird communities are immediately impacted by fire-driven resource changes, they can rebound over time, it is unclear how long-term drought may continue to shape the composition of these avian communities.

59 BASIC BIOLOGICAL SCIENCES↗

Automating Risk Assessments of Hazardous Material Shipments for Transportation Routes and Mode Selection

The METEOR project at Idaho National Laboratory (INL) successfully addresses the difficult problem in risk assessment analyses of combining the results from bounding deterministic simulation results with probabilistic (Monte Carlo) risk assessment techniques. This paper describes a software suite designed to perform sensitivity and cost/benefit analyses on selected transportation routes and vehicles to minimize risk associated with the shipment of hazardous materials. METEOR uses Monte Carlo techniques to estimate the probability of an accidental release of a hazardous substance along a proposed transportation route. A METEOR user selects the mode of transportation, origin and destination points, and charts the route using interactive graphics. Inputs to METEOR (many selections built in) include crash rates for the specific aircraft, soil/rock type and population densities over the proposed route, and bounding limits for potential accident types (velocity, temperature, etc.). New vehicle, materials, and location data are added when available. If the risk estimates are unacceptable, the risks associated with alternate transportation modes or routes can be quickly evaluated and compared. Systematic optimizing methods will provide the user with the route and vehicle selection identified with the lowest risk of hazardous material release. The effects of a selected range of potential accidents such as vehicle impact, fire, fuel explosions, excessive containment pressure, flooding, etc. are evaluated primarily using hydrocodes capable of accurately simulating the material response of critical containment components. Bounding conditions that represent credible accidents (i.e; for an impact event, velocity, orientations, and soil conditions) are used as input parameters to the hydrocode models yielding correlation functions relating accident parameters to component damage. The Monte Carlo algorithms use random number generators to make selections at the various decision points such as; crash, location, etc. For each pass through the routines, when a crash is randomly selected, crash parameters are then used to determine if failure has occurred using either external look up tables, correlations functions from deterministic calculations, or built in data libraries. The effectiveness of the software was recently demonstrated in safety analyses of the transportation of radioisotope systems for the US Dept. of Energy. These methods are readily adaptable to estimating risks associated with a variety of hazardous shipments such as spent nuclear fuel, explosives, and chemicals.

42 ENGINEERING↗

Chemical changes in thirdhand smoke associated with remediation using an ozone generator

Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m 3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h -1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O 3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conclusions from 3 years of continuous capture plant operation without exchange of the AMP/PZ-based solvent at Niederaussem – insights into solvent degradation management

A many times heard mantra of solvent degradation management in amine-based post combustion capture is “keep the solvent clean” to minimize solvent consumption. It is assumed that the amine losses would decrease by the removal of metals, degradation products, and reactive trace components which are captured from the flue gas, like NO 2 (as potentially driving components of the amine degradation besides dissolved O 2 ). However, this theoretical hypothesis – based on results from laboratory experiments typically generated with fresh amines – disregards the complexity of the solvent matrix, interaction of potential metal catalysts with degradation products and oxidizing agents, and specific chemical requirements which must be fulfilled before a degradation mechanism can proceed. Degradation of the solvent CESAR1 (aqueous solution of 3.0 molar 2-amino-2-methylpropan-1-ol (AMP) and 1.5 molar piperazine (PZ)) is investigated in a unique long-time test campaign (testing time up to now 40 months; 24/7 operation) without replacement of the solvent inventory at the capture pilot plant at the lignite-fired power plant in Niederaussem. Three solvent management strategies with different effect mechanisms are investigated and evaluated: (a) removal of only anionic compounds and trace elements (within 75 days solvent inventory treated two times) and anionic as well as cationic compounds and trace elements (114 days, inventory treated four times) from the solvent by ion exchange, (b) adsorptive removal of trace elements from the solvent by active carbon in 35% of the operating time, and (c) removal of >80% NO 2 by flue gas pretreatment with thiosulfate/sulfite solution (dosing for 2,000 h). The results of the testing program clearly show that “solvent cleanliness” is not a well-defined parameter and that results from laboratory tests, tests without fully representative industrial flue gasses, and short-term testing of monoethanolamine cannot be generalized for other solvents and industrial application. Furthermore, these results showcase that specific degradation management considering solvent, capture plant and flue gas quality is reasonable. Overshooting efforts for solvent management are contra-productive and produce unnecessary waste streams, efficiency losses and costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗