Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Plasma Ignition and Combustion Stabilization Technology to Improve Flexible Operation, Reliability and Economics of an Existing Coal-Fired Boiler

GE Steam Power, Inc. (GE) proposed to improve reliability, flexibility, and economics of an existing coal-fired power plant by applying a new advanced technology developed by GE, a plasma-assisted pulverized fuel firing system. The objective of this program is to demonstrate the achievement of lower load by improved flame stabilization and therefore lower operating costs in a full-scale field installation at coal-fired electric utility. GE’s Plasma Ignition and Combustion Stabilization System is designed to operate continuously to support low load operation. With the plasma on, the flame will be attached and stable, removing the firing system as a limitation to low load operation. In addition, GE’s exclusively from ABENZ company licensed AC based technology has a 90+% system efficiency compared to all other systems at which are DC and operate with ~75% efficiency. Plant operating costs are lowered by eliminating use of expensive support fuel as well as the ability to operate at lower loads. The utilities’ ability to better match the demand curve will result in significant savings. Maintenance is lower for an AC system than a DC system as it operates at lower current. This eliminates the need for a demineralized cooling water system and provides longer electrode life which translates into both material and labor savings. It is the objective of GE to not only demonstrate the additional low load achievable with a plasma system after best achievable tuning, sensor and software approach has been exhausted, but also the increased stability of the flame at all loads with plasma assistance as well as cost savings at all low loads using plasma instead of oil. Upon successful completion of this project, GE will have sufficient field experience to rapidly deploy the Plasma Technology. The project objectives were achieved through the implementation of plasma ignitor technology at PacifiCorp Hunter Station Unit 3. A plasma ignitor system was retrofitted on ten wall-fired burners, Mill 3-4 combustion system. The Plasma Ignitors installed at Hunter proved that this GE technology is a direct and complete replacement for the original oil ignitors. The Hunter Unit 3 burner management system allows the plasma system to be used in all applications that originally required oil to be burned. This includes any time the Mill 3-4 is started or stopped for any reason including boiler starts, load changes, and low load support.

01 COAL, LIGNITE, AND PEAT↗

Wind Loading on Parabolic Trough Collectors: Wind and Structural Loads Measurements at an Operational Powerplant

Concentrated Solar Power (CSP) is a promising method for using solar power for electricity generation with thermal energy storage for industrial applications. Solar collectors constitute almost 1/3 of the total cost of the power plant. One of the primary drivers of unrealiability of these collectors is wind-driven loading of mirrors, support structures, and drives. To date, the design of the solar collector structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) parabolic trough powerplant. At this plant, parabolic trough solar collectors track the sun from east to west in the course of a day and face varying wind loads depending on the wind properties and the angle of the troughs. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights into structural dynamic response, and generating a comprehensive wind-loading dataset for validating simulations of wind loading on collector structures. The measurements at NSO consist of sonic anemometers on masts at different heights to characterize the incoming flow and conditions at four trough rows at the edge of the trough field. In addition, a Doppler Lidar scans the horizontal plane above the troughs. The wind measurements at NSO have been continuously collecting data since October 2021 and are combined with structural load measurements that started in November 2022. The load measurements were installed on the same four outermost trough rows and include support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Measurements are planned to continue until May 2023, providing a first-of-a-kind, high-resolution multi-month dataset of combined wind and load measurements. In this presentation, we show first results of the measurement campaign. Based on the measurements, we identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. Most interactions between incoming wind and the trough field are observed when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest wind speed and block the downwind rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales are smaller after the first row. This leads to the highest static loads (bending and torque moments) at the first row but potentially increased dynamic loads within the field. We illustrate our findings with case studies focused on different wind conditions and will present fatigue analysis to highlight the impact of wind-driven loads on collector structures.

CSP collectors↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proactive demand-side participation: Centralized versus transactive demand-Supply coordination

The active participation of demand-side flexible resources in the wholesale market price formation and load dispatch process is crucial to encouraging demand-side participation. This calls for a joint supply-demand coordination mechanism to fully take advantage of the flexible resources in distribution systems, including distributed energy resources (DERs) and responsive loads (RLs). Here this paper aims at comparing and evaluating the centralized and transactive distribution-level market coordination mechanisms. We introduce the centralized and transactive demand-supply coordination mechanisms for the distribution-level market and elaborate on the structural difference between the two frameworks. Relevant metrics and test scenarios are proposed for a meaningful comparison. The key observations of the comparative study are generalized from the perspective of different entities in the market: fixed loads, flexible loads, DERs, and conventional generators. It is observed that while the centralized approach leads to socially optimum solutions, the transactive approach by allowing for competitive bidding at the distribution-level, results in clearing higher flexible demand, and thus higher electricity cost at the transmission-level. As a result, DERs and fixed loads receive a higher surplus in the centralized approach, while conventional generators and flexible loads are more profitable in the transactive approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Silicon Steel Strip by Single-Step Shear Deformation Processing

It is well known that Fe-Si alloys with Si content higher than in conventional electrical sheet steels (>3.2% Si) can make a significant impact in improving the efficiency of electrical motors if they are available in sheet/foil (strip) forms at suitable cost. While the magnetic and electrical attributes (e.g., resistivity, core loss) of these high-Si Fe alloys, of relevance to electrical motor core laminations, are known to be exceptional, the alloys have limited workability, making them difficult to produce consistently in sheet/foil (strip) forms. Current processing techniques such as rolling, while adequate for producing conventional electrical steel sheet, do have important disadvantages - large energy consumption and emissions, limitations in processing of low-workability alloys (e.g., high-Si content steels), large-scale plant infrastructure, and less than adequate capability to engineer sheet metals with specific microstructures (e.g., fine-grained) and crystallographic textures (e.g., shear textures). It is therefore of interest to have an alternative commercial process that can produce sheet/foil (strip) from high-Si Fe alloys and which can also overcome some of the deficiencies of current multistage strip processes. The goal of the present project was design and demonstration of a new energy-efficient pilot process for producing high-Si electrical steel strip of commercial widths and thickness, and with superior electrical and magnetic properties than current electrical steels (Fe-3.2% Si as benchmark). The applications domain for these steels is electrical motor core laminations. We have addressed this goal by accomplishment of the following specific objectives and tasks: a) Development of an Fe-4Si-4Cr alloy with electrical resistivity >80 μΩ-cm, induction flux density >1.48 T at 5000 A/m and core loss 35% lower than the benchmark 3.2% Si alloy. The alloy which meets DOE target specifications for motor core attributes was designed with the Si content controlled for the electrical properties and the Cr content tailored to meet material/process workability requirements. b) A unique machining-based deformation processing system was designed and scaled-up to produce strip of commercial width (25 mm to 150 mm) and thickness (up to 0.5 mm) from the Fe-4Si-4Cr alloy and other alloys of varied workability including copper, Al6061-T6 and naval brass. The key attributes of the machining-based strip production are deformation processing by concentrated simple-shear; single-step production of strip from ingot using compact machine infrastructure; strip surface finish of Ra 0.35 to 1 micrometer that is comparable/superior to that of rolled strip; discrete production of strip that can potentially be done at point of use; and controllability of strip mechanical/formability properties by deformation control. c) The electrical, magnetic, surface quality, mechanical, formability, and metallurgical properties/attributes of the machining-based strip were established by direct ASTM standard or equivalent measurement techniques. d) Punching characteristics of the strip in terms of load, edge quality and macro defects were similar to those of conventional 3.2% Si electrical steels. These punching characteristics are critical from a manufacturability perspective for motor/transformer core applications. e) A modeling framework for energy analysis of multistage rolling and the machining-based deformation processing has been established. Application of this modeling to the two strip-processes showed that the machining-based process requires significantly lower specific energy for processing, ~ 25% of that for rolling. The modeling framework can be adapted for a range of sheet-metal forming, bulk metal forming, and machining processes. It can be used to identify key parameters controlling process specific energy. f) A comparative analysis of advantages and disadvantages of machining-based processing against rolling for strip production. The single stage machining-based processing, with compact infrastructure, represents a new manufacturing paradigm for sheet and foil manufacturing that can potentially also be applied to advanced titanium, aluminum, copper and magnesium alloys. The goals and objectives were accomplished by a cross-disciplinary project team comprising of personnel from Purdue University; M4 Sciences LLC, a small-business focused on advanced manufacturing technology development; the Pacific Northwest National Labs; and tool manufacturers. The team is currently in advanced discussions with multiple entities for future process development for commercialization.

36 MATERIALS SCIENCE↗

Considerations for Distributed Edge Data Centers and Use of Building Loads to Support Large Interconnections

The rapid expansion of artificial intelligence (AI) and machine learning is driving unprecedented electricity demand from data centers. It is predicted that by 2030, 90% of AI workloads will be inference-based, requiring interconnection of multiple low-latency edge data centers (<20 MW) sited closer to end users - often on already constrained distribution feeders. Although individually small, these loads can aggregate to large loads per feeder, straining infrastructure, creating multi-year interconnection delays, and driving up customer costs. This paper proposes a data center-focused grid-integration framework that combines feeder hosting capacity analysis with building energy efficiency, building load flexibility, and waste heat reuse to expand effective feeder and substation headroom. Such approaches can reduce interconnection delays, lower costs for ratepayers, and accelerate AI-ready infrastructure deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fielding and analyzing performance of a prototype high voltage output gas switch for Saturn

Timing spread between the thirty-six Saturn modules affects peak electrical power delivered to the Bremsstrahlung diode and can affect vacuum power flow and impedance behavior of the load. To reduce the module spread, a new megavolt gas-insulated closing switch was developed employing design techniques developed for the Z-machine laser triggered switches while retaining Saturn’s simpler electrical triggering. Two modules were temporarily outfitted with the new switches and used separately into local resistive loads (instead of the usual Saturn electron beam load). A reliable operating point and switch time jitter at that point were the goals of the experiments. The target switch reliability is less than one pre-fire in one thousand switch-shots, and a timing standard deviation of 4 nanoseconds. The switches were able to meet both requirements but the number of tests at the chosen point are limited.

43 PARTICLE ACCELERATORS↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Structure, properties, and applications of polyacrylonitrile/carbon nanotube ( CNT ) fibers at low CNT loading

Abstract Bi‐component, polyacrylonitrile (PAN)/carbon nanotube (CNT) fibers were processed, at different core‐sheath area ratios, by gel spinning. A percolated CNT network at 10 wt% CNT in the sheath enhanced electrical conductivity as compared to the neat PAN fiber, while PAN polymer in the core contributed to the good mechanical properties. Fibers with relatively thin sheath allowed overall CNT loading as low as 3.7 wt% to be made with good electrical conductivity, and PAN stabilization by Joule heating was demonstrated. Such fibers with combined good mechanical properties and electrical conductivity can also potentially be used for electrical heating of fabrics, for making smart textiles, and for electromagnetic interference shielding.

Lu, Mingxuan↗

A nuclear-hydrogen hybrid energy system with large-scale storage: A study in optimal dispatch and economic performance in a real-world market

Here a study in optimal dispatch and economic analysis of a novel nuclear hybrid energy system (NHES) with large-scale hydrogen storage and a novel control scheme is conducted. The control scheme makes charge and discharge decisions by using the real-time electricity price relative to the historical price distribution. The pricing data is taken from the ERCOT Houston and West load zones with different price oscillations. Six case control studies with different levels of aggressiveness were chosen for each load zone for a total of 12 case studies. It is found that in a high price volatility load zone, a more aggressive control strategy maximizes revenue, while in a less oscillatory load zone, a moderate control strategy performs better. The NHES can store energy when the price is low and sell additional electricity when the price is high, as well as participate in the ancillary services market. Due to these advantages, the NHES can generate 10–40 million USD more revenue annually than a stand-alone nuclear plant. Due to higher costs, the NHES has a higher LCOE (81.36 USD/MWh) than a stand-alone plant (68.66 USD/MWh); however, the LCOE of the NHES is still comparable to other new forms of electricity generation. It is found that both the NHES and the stand-alone plant are not economical in the existing electricity market. Due to the extra revenue generated, the hybrid system has a positive annual cashflow whereas the stand-alone plant does not. It is found that the hybrid plant needs less cost subsidy than a stand-alone plant to become economical.

08 HYDROGEN↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Addressing energy storage needs at lower cost via on-site thermal energy storage in buildings

Cost-effective energy storage is a critical enabler for the large-scale deployment of renewable electricity. Significant resources have been directed toward developing cost-effective energy storage, with research and development efforts dominated by work on lithium ion (Li-ion) battery technology. Though Li-ion batteries have many attractive qualities, it is not clear whether they can provide an affordable levelized cost of storage (LCOS) for certain applications, such as buildings. Buildings consume most of the world's electricity, and as much as 50% of their consumption goes toward meeting thermal loads. Thermal energy storage (TES) can provide a cost-effective alternative to Li-ion batteries for buildings; however, two questions remain to be answered. First, how much of total building energy storage requirements can be met via thermal storage for building loads? Second, can the LCOS for TES be favorable compared with Li-ion batteries? In this perspective, using the United States as a case study, we show that the total requirement for TES in buildings is in the range of ~1200–4500 electrical GW h, depending on the fraction of solar versus wind in the generation mix. Furthermore, we show that with at least 25% wind generation, all of the storage needed by buildings to support the grid can be met by TES. We also introduce a framework to calculate LCOS for on-site TES in buildings to enable a direct comparison with electrical storage technologies such as Li-ion batteries. This is not trivial, because the input energy type for TES (electricity) differs from the output energy type (thermal energy), and the efficiency can depend on ambient conditions. Our LCOS analysis shows that in many situations, TES can be more cost-effective for buildings than Li-ion batteries. We conclude our perspective by discussing future research and development opportunities that can significantly advance the deployment of TES for buildings to help enable a renewable electricity-dependent grid.

25 ENERGY STORAGE↗

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Improved CHP Systems utilizing Improved Gas Turbine and sCO2 Cycles Using Additive Manufacturing (AM) Components

This project seeks to integrate a sCO2 bottoming cycle with a 5.3 MW gas turbine to develop a CHP system that is able to transition rapidly between 50% and 100% load by engaging or bypassing the bottoming cycle while maintaining electrical system efficiency above 30% at all times. The project team will engineer an optimized design of the power systems. The needed new key components, such as advanced heat exchangers and a steam injection system for the gas turbine, will be developed and their performance demonstrated in rig tests. The feasibility of the whole integrated CHP system will be validated through a cyber-physical approach.

36 MATERIALS SCIENCE↗

H3 Final Design and Technical Report

The goal of this Project was to develop a standards-compliant, fabrication-ready design of Columbia Power Technologies’ (C·Power) next-generation wave energy converter (WEC), the StingRAY H3p. The H3p is a design iteration of C·Power’s StingRAY WEC and is intended for electrical power generation suitable for micro-grids or remote loads. The H3p was designed for grid-connection and at least two years of continuous testing and operation at the proposed PacWave-South (PWS) test site.

16 TIDAL AND WAVE POWER↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗