Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficiencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Efficiency Improvement of Nitride-Based Solid State Light Emitting Materials -- CRADA Final Report

The development of In{sub x}Ga{sub 1-x} N/GaN thin film growth by Molecular Beam Epitaxy has opened a new route towards energy efficient solid-state lighting. Blue and green LED's became available that can be used to match the whole color spectrum of visible light with the potential to match the eye response curve. Moreover, the efficiency of such devices largely exceeds that of incandescent light sources (tungsten filaments) and even competes favorably with lighting by fluorescent lamps. It is, however, also seen in Figure 1 that it is essential to improve on the luminous performance of green LED's in order to mimic the eye response curve. This lack of sufficiently efficient green LED's relates to particularities of the In{sub x}Ga{sub 1-x}N materials system. This ternary alloy system is polar and large strain is generated during a lattice mismatched thin film growth because of the significantly different lattice parameters between GaN and InN and common substrates such as sapphire. Moreover, it is challenging to incorporate indium into GaN at typical growth temperatures because a miscibility gap exists that can be modified by strain effects. As a result a large parameter space needs exploration to optimize the growth of In{sub x}Ga{sub 1-x}N and to date it is unclear what the detailed physical processes are that affect device efficiencies. In particular, an inhomogeneous distribution indium in GaN modifies the device performance in an unpredictable manner. As a result technology is pushed forward on a trial and error basis in particular in Asian countries such as Japan and Korea, which dominate the market and it is desirable to strengthen the competitiveness of the US industry. This CRADA was initiated to help Lumileds Lighting/USA boosting the performance of their green LED's. The tasks address the distribution of the indium atoms in the active area of their blue and green LED's and its relation to internal and external quantum efficiencies. Procedures to measure the indium distribution with near atomic resolution were developed and applied to test samples and devices that were provided by Lumilids. Further, the optical performance of the device materials was probed by photoluminescence, electroluminescence and time resolved optical measurements. Overall, the programs objective is to provide a physical basis for the development of a simulation program that helps making predictions to improve the growth processes such that the device efficiency can be increased to about 20%. Our study addresses all proposed aspects successfully. Carrier localization, lifetime and recombination as well as the strain-induced generation of electric fields were characterized and modeled. Band gap parameters and their relation to the indium distribution were characterized and modeled. Electron microscopy was developed as a unique tool to measure the formation of indium clusters on a nanometer length scale and it was demonstrated that strain induced atom column displacements can reliably be determined in any materials system with a precision that approaches 2 pm. The relation between the local indium composition x and the strain induced lattice constant c(x) in fully strained In{sub x}Ga{sub 1-x}N quantum wells was found to be: c(x) = 0.5185 + {alpha}x with {alpha} = 0.111 nm. It was concluded that the local indium concentration in the final product can be modulated by growth procedures in a predictable manner to favorably affect external quantum efficiencies that approached target values and that internal quantum efficiencies exceeded them.

36 MATERIALS SCIENCE↗

Assessment of Energy Efficiency Improvement in the United States Petroleum Refining Industry

Adoption of efficient process technologies is an important approach to reducing CO 2 emissions, in particular those associated with combustion. In many cases, implementing energy efficiency measures is among the most cost-effective approaches that any refiner can take, improving productivity while reducing emissions. Therefore, careful analysis of the options and costs associated with efficiency measures is required to establish sound carbon policies addressing global climate change, and is the primary focus of LBNL’s current petroleum refining sector analysis for the U.S. Environmental Protection Agency. The analysis is aimed at identifying energy efficiency-related measures and developing energy abatement supply curves and CO 2 emissions reduction potential for the U.S. refining industry. A refinery model has been developed for this purpose that is a notional aggregation of the U.S. petroleum refining sector. It consists of twelve processing units and account s for the additional energy requirements from steam generation, hydrogen production and water utilities required by each of the twelve processing units. The model is carbon and energy balanced such that crud e oil inputs and major refinery sector outputs (fuels) are benchmarked to 2010 data. Estimates of the current penetration for the identified energy efficiency measures benchmark the energy requirements to those reported in U.S. DOE 2010 data. The remaining energy efficiency potential for each of the measures is estimated and compared to U.S. DOE fuel prices resulting in estimates of cost- effective energy efficiency opportunities for each of the twelve major processes. A combined cost of conserved energy supply curve is also presented along with the CO 2 emissions abatement opportunities that exist in the U.S. petroleum refinery sector. Roughly 1,200 PJ per year of primary fuels savings and close to 500 GWh per y ear of electricity savings are potentially cost-effective given U.S. DOE fuel price forecasts. This represents roughly 70 million metric tonnes of CO 2 emission reductions assuming 2010 emissions factor for grid electricity. Energy efficiency measures resulting in an additional 400 PJ per year of primary fuels savings and close to 1,700 GWh per year of electricity savings, and an associated 24 million metric tonnes of CO 2 emission reductions are not cost-effective given the same assumption with respect to fuel prices and electricity emissions factors. Compared to the modeled energy requirements for the U.S. petroleum refining sector, the cost effective potential represents a 40% reduction in fuel consumption and a 2% reduction in electricity consumption. The non-cost-effective potential represents an additional 13% reduction in fuel consumption and an additional 7% reduction in electricity consumption. The relative energy reduction potentials are mu ch higher for fuel consumption than electricity consumption largely in part because fuel is the primary energy consumption type in the refineries. Moreover, many cost effective fuel savings measures would increase electricity consumption. The model also has the potential to be used to examine the costs and benefits of the other CO 2 mitigation options, such as combined heat and power (CHP), carbon capture, and the potential introduction of biomass feedstocks. However, these options are not addressed in this report as this report is focused on developing the modeling methodology and assessing fuels savings measures. These opportunities to further reduce refinery sector CO 2 emissions and are recommended for further research and analysis.

25 ENERGY STORAGE↗

The Future of Utility Customer-Funded Energy Efficiency Programs in the United States: Projected Spending and Savings to 2025

We develop projections of future spending on, and savings from, energy efficiency programs funded by electric and gas utility customers in the United States, under three scenarios through 2025. Our analysis, which updates a previous LBNL study, relies on detailed bottom-up modeling of current state energy efficiency policies, regulatory decisions, and demand-side management and utility resource plans. The three scenarios are intended to represent a range of potential outcomes under the current policy environment (i.e., without considering possible major new policy developments). By 2025, spending on electric and gas efficiency programs (excluding load management programs) is projected to double from 2010 levels to $9.5 billion in the medium case, compared to $15.6 billion in the high case and $6.5 billion in the low case. Compliance with statewide legislative or regulatory savings or spending targets is the primary driver for the increase in electric program spending through 2025, though a significant share of the increase is also driven by utility DSM planning activity and integrated resource planning. Our analysis suggests that electric efficiency program spending may approach a more even geographic distribution over time in terms of absolute dollars spent, with the Northeastern and Western states declining from over 70% of total U.S. spending in 2010 to slightly more than 50% in 2025, with the South and Midwest splitting the remainder roughly evenly. Under our medium case scenario, annual incremental savings from customer-funded electric energy efficiency programs increase from 18.4 TWh in 2010 in the U.S. (which is about 0.5% of electric utility retail sales) to 28.8 TWh in 2025 (0.8% of retail sales). These savings would offset the majority of load growth in the Energy Information Administration’s most recent reference case forecast, given specific assumptions about the extent to which future energy efficiency program savings are captured in that forecast. However, the pathway that customer-funded efficiency programs ultimately take will depend on a series of key challenges and uncertainties associated both with the broader market and policy context and with the implementation and regulatory oversight of the energy efficiency programs themselves.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Combined Heat and Power Systems Technology Development and Demonstration 370 kW High Efficiency Microturbine

The C370 Program was awarded in October 2010 with the ambitious goal of designing and testing the most electrically efficient recuperated microturbine engine at a rated power of less than 500 kW. The aggressive targets for electrical efficiency, emission regulatory compliance, and the estimated price point make the system state-of-the-art for microturbine engine systems. These goals will be met by designing a two stage microturbine engine identified as the low pressure spool and high pressure spool that are based on derivative hardware of Capstone’s current commercially available engines. The development and testing of the engine occurred in two phases. Phase I focused on developing a higher power and more efficient engine, that would become the low pressure spool which is based on Capstone’s C200 (200kW) engine architecture. Phase II integrated the low pressure spool created in Phase I with the high pressure spool, which is based on Capstone’s C65 (65 kW) commercially available engine. Integration of the engines, based on preliminary research, would allow the dual spool engine to provide electrical power in excess of 370 kW, with electrical efficiency approaching 42%. If both of these targets were met coupled with the overall CHP target of 85% total combined heating and electrical efficiency California Air Resources Board (CARB) level emissions, and a price target of $600 per kW, the system would represent a step change in the currently available commercial generation technology. Phase I of the C370 program required the development of the C370 low pressure spool. The goal was to increase the C200 engine power by a minimum of 25% — 250 kW — and efficiency from 32% to 37%. These increases in the C200 engine output were imperative to meet the power requirements of the engine when both spools were integrated. An additional benefit of designing and testing the C370 low pressure spool was the possibility of developing a stand-alone product for possible commercialization. The low pressure spool design activity focused on an aeropath derivative of the current C200 engine. The aeropath derivative included changes to the compressor section —compressor and inducer — and to the turbine nozzle. The increased power also necessitated a larger, more powerful generator and generator controller to support the increased power requirements. These two major design changes were completed by utilizing both advanced 3D modeling and computational fluid dynamics modelling. After design, modeling, and analysis, the decision was made to acquire and integrate the components for testing. The second task of Phase I was to integrate and test the components of the low pressure spool to validate power and efficiency. Acquisition of the components for the low pressure spool was completed utilizing Capstone’s current supplier base. Utilization of Capstone’s supply base for integration of the test article would allow — if the decision was made —expedited commercialization of the product. After integration of the engine components, the engine was tested and evaluated for performance and emissions. Test data analysis confirmed that the engine met all power and efficiency requirements and did so while maintaining CARB level emissions. The emissions were met without the use of any post processing or catalyst. After testing was completed, the DOE authorized — via a milestone review — proceeding to Phase II: the development of the integrated C370 engine. The C370 high pressure spool design activity required significant changes to the C65 engine architecture. The engine required a high power density generator, completely redesigned compressor stage, turbine section, recuperator, controls architecture, and intercooler stage asThe two most critical design challenges were the turbine section (the nozzle and turbine) and the controls architecture. The design and analysis of all of the components was completed and integrated into a system model. The system model — after numerous iterations — indicated that, once integrated, the engine will meet or exceed all system requirements. Unfortunately, the turbine section’s life requirements remain a technical challenge and will require continued refinement of the bi-metallic turbine wheel design and manufacturing approach to meet the life requirement at theses high temperatures. The current controls architecture requires substantial effort to develop a system capable of handling the high-speed, near real-time controls requirement, but it was determined not to be a technical roadblock for the project. The C370 Program has been a significant effort with state-of-the-art technical targets. The targets have pushed Capstone’s designers to the limits of current technology. The program has been fortunate to see many successes: the successful testing of the low pressure spool (C250), the development of new material processes, and the implementation of new design practices. The technology and practices learned during the program will be utilized in Capstone’s current product lines and future products. The C370 Program has been a resounding success on many fronts for the DOE and for Capstone.

none↗

Using learning curves on energy-efficient technologies to estimate future energy savings and emission reduction potentials in the U.S. iron and steel industry

Increasing concerns on non-sustainable energy use and climate change spur a growing research interest in energy efficiency potentials in various critical areas such as industrial production. This paper focuses on learning curve aspects of energy efficiency measures in the U.S iron and steel sector. A number of early-stage efficient technologies (i.e., emerging or demonstration technologies) are technically feasible and have the potential to make a significant contribution to energy saving and CO 2 emissions reduction, but fall short economically to be included. However, they may also have the cost effective potential for significant cost reduction and/or performance improvement in the future under learning effects such as ‘learning-by-doing’. The investigation is carried out using ISEEM, a technology oriented, linear optimization model. We investigated how steel demand is balanced with/without the availability learning curve, compared to a Reference scenario. The retrofit (or investment in some cases) costs of energy efficient technologies decline in the scenario where learning curve is applied. The analysis also addresses market penetration of energy efficient technologies, energy saving, and CO 2 emissions in the U.S. iron and steel sector with/without learning impact. Accordingly, the study helps those who use energy models better manage the price barriers preventing unrealistic diffusion of energy-efficiency technologies, better understand the market and learning system involved, predict future achievable learning rates more accurately, and project future savings via energy-efficiency technologies with presence of learning. We conclude from our analysis that, most of the existing energy efficiency technologies that are currently used in the U.S. iron and steel sector are cost effective. Penetration levels increases through the years, even though there is no price reduction. However, demonstration technologies are not economically feasible in the U.S. iron and steel sector with the current cost structure. In contrast, some of the demonstration technologies are adapted in the mid-term and their penetration levels increase as the prices go down with learning curve. We also observe large penetration of 225kg pulverized coal injection with the presence of learning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Efficiency Financing for Low- and Moderate-Income Households: Current State of the Market, Issues, and Opportunities

Ensuring that low- and moderate-income (LMI) households have access to energy efficiency is equitable, provides energy savings as a resource to meet energy needs, and can support multiple policy goals, such as affordable energy, job creation, and improved public health. Although the need is great, many LMI households may not be able to afford efficiency improvements or may be inhibited from adopting efficiency for other reasons. Decision-makers across the country are currently exploring the challenges and potential solutions to ramping up adoption of efficiency in LMI households, including the use of financing. The report’s objective is to offer state and local policymakers, state utility regulators, program administrators, financial institutions, consumer advocates and other LMI stakeholders with an understanding of: -The relationship between LMI communities and financing for energy efficiency, including important considerations for its use such as consumer protections -The larger programmatic context of grant-based assistance and other related resources supporting LMI household energy efficiency -Lessons learned from existing energy efficiency financing programs serving LMI households -Financing products used by these programs and their relative advantages and disadvantages in addressing barriers to financing or to energy efficiency uptake for LMI households

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Time-Sensitive Value of Efficiency: Use Cases in Electricity Sector Planning and Programs

Most energy efficiency measures produce energy savings that vary over the course of a year. The value of the hourly electricity savings also varies over the course of a year because the cost of generating, transmitting and distributing electricity during peak demand periods may be significantly higher than during off-peak, or lower load, hours. But many planning and program activities across the United States are missing this important element. A variety of trends are changing the electricity system, including increased adoption of other distributed energy resources, electrification of buildings and vehicles, and relative costs for natural gas-fired and renewable energy generation. Knowing when energy efficiency occurs and the value of the energy or demand savings to the electricity system—the time-sensitive value of efficiency—provides public utility commissions, utilities and other decision makers with key information needed to procure the optimal amount of energy efficiency for their system. The report begins with a discussion of our approach to determining use cases and examples, and then examines the need for time-sensitive efficiency data. Next, it examines five use cases in which states, independent system operators/regional transmission operators (ISOs/RTOs), utilities, and efficiency program administrators consider the TSV-EE: (1) energy efficiency program planning and evaluation, (2) distribution system planning, (3) electricity resource planning (4) electricity rate design, and (5) state and local government activities. The report concludes with areas for future research on the time-sensitive value of efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Update of Emission Factors of Greenhouse Gases and Criteria Air Pollutants, and Generation Efficiencies of the U.S. Electricity Generation Sector

The last decade has seen a steady evolution of the electricity generation sector. Fuels used for electricity generation have shifted from coal to cleaner energy sources such as natural gas and renewables including solar, wind, and other renewable sources. The share of U.S. electricity generated from coal decreased from 45% in 2010 to 24% in 2019, and is expected to decrease further to 13% by 2050. The conversion efficiency of electricity generation has also increased gradually for fuels such as natural gas due as less-efficient old generators are retired and more-efficient generators replace them. These changes in the electricity generation industry are likely to cause changes in the emissions from power generation units. Emission factors of greenhouse gases (GHG) including CO 2 , CH 4 , and N 2 O, and criteria air pollutants (CAPs) including CO, NO x , PM 10 , PM 2.5 , and SO x , from power plants are important parameters for estimating life-cycle emissions associated with vehicle electrification, energy systems, and the production of materials and chemicals. The electricity generation technologies and associated emission factors in the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model need to be updated to reflect recent developments in the electricity generation sector. The most recent update of the electricity generation emission factors in GREET adopted a mixed method. The emission factors of CH 4 , N 2 O, NO x , and SOx were estimated using a “topdown” approach by dividing the total emissions by the total net electricity generation, because emission data of these pollutants are readily available in the Emissions & Generation Resource Integrated Database (eGRID). For other CAPs such as CO, VOC, PM 10 , and PM 2.5 , emission data were not reported in eGRID. A “bottom-up” method was used to estimate the emission factors for these pollutants by considering generic uncontrolled emission factors and the pollutant removal efficiencies of emission control technologies adopted in the electricity generation sector. However, the uncontrolled emission factors and the emission removal efficiencies of various emission control technologies considered in the 2012 study came from the legacy AP-42 emission factors, and may not reflect the actual emission performances of the electricity generation sector of today. To leverage new data that recently became available, especially emission data measured from continuous emission monitoring systems (CEMS), we developed a new “top-down” approach to estimate efficiencies and GHG and CAP emission factors for electricity generation from combustion of individual fuel types by individual combustion technologies on the basis of power-generation data from U.S. Energy Information Administration’s (EIA’s) form EIA-923, and plant emission data from Environmental Protection Agency’s (EPA’s) Clean Air Markets Division (CAMD) dataset and National Emissions Inventory (NEI) dataset. Detailed discussion of the method and data used in this study can be found in Section 2.1. With this topdown approach, we aim to improve the estimates of energy efficiencies and emission factors for power plants using a more consistent methodology, and to update the emission factors, generation efficiencies, and generation technologies mixes in GREET to reflect recent technology advancements in the electricity generation sector.

20 FOSSIL-FUELED POWER PLANTS↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accelerating Energy Efficiency Improvements in Room Air Conditioners in India: Potential, Costs-Benefits, and Policies

Rising incomes, increasing urbanization, and large cooling demand prompted by India’s hot, humid climate are driving increasing uptake of room air conditioners (ACs). Air conditioning already accounts for 40-60% of summer peak load in large Indian cities such as Delhi and is on track to contribute 140 gigawatts (GW) (~30%) to peak demand in 2030. India’s standards and labeling policies improved the market average efficiency of room ACs by about 35% between 2006 and 2016 (3% per year) even as inflation-adjusted room AC prices continued to decline. In this report, we assess the technical feasibility and costs and benefits of accelerating the efficiency improvement in room ACs in India and discuss policy enhancements needed to achieve this goal. We also describe examples of rapid AC efficiency improvement from Japan and Korea. Driven by appropriate policies and programs, AC efficiency in these countries improved by more than 8% per year, resulting in near-doubling of energy efficiency over seven to ten years while inflationadjusted AC prices declined. We also find that the most efficient room AC sold on the Indian market is almost twice as efficient as the average AC sold on the market in 2015-16. As a result, we conclude that the technology needed to accelerate room AC efficiency in India is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling Egypt: Cost and benefits of room air conditioner efficiency improvement in Egypt

Egypt is one of the largest countries in the Middle East and North Africa region with a population of a total of 106 million (as of July 2022). Increasing urbanization, population growth, and increasing temperatures will likely continue to drive demand for electricity from air conditioning, with corresponding negative impacts on the peak load, air quality, and greenhouse gas emissions from refrigerant use and energy consumption. Since 2003, Egypt has adopted a standards and labeling program for various appliances, and has improved its room air conditioner (RAC) energy efficiency requirements in 2016 and 2017. However, its market is still dominated by inefficient fixed-speed drive (FSD) RACs due to a price-sensitive market. Seasonal metrics such as Cooling Season Performance Factor (CSPF) measure the energy efficiency of FSD and variable-speed drive (VSD) RACs on the same scale. Leading markets, most notably China, have already adopted a new MEPS in 2020 and 2022, which align largely with the United for Efficiency (U4E) Model Regulations Guidelines. India has also adopted a CSPF metric. Both India and China are now experiencing (1) increased demand and consumption of higher efficiency VSD RACs, as well as (2) a corresponding drop in prices from the economies of scale of production of these higher efficiency RACs. Because China is a leading manufacturer in the global air conditioner (AC) market, its adoption of the model U4E regulations have effectively raised the energy efficiency of the ACs in the global market. To achieve the benefits of taking a similar approach to Egypt’s market, we offer the following recommendations: 1. Adopt a common metric to measure the efficiency of both FSD and VSD RACs 2. Raise the stringency of MEPS to the level of the U4E Model Regulation Guidelines 3. Restructure the labeling program from the “A++” labeling scheme to a simpler A through E or a star-rating program 4. Strengthen the compliance regime governing the Egyptian AC MEPS 5. Assist small and medium AC manufacturers in Egypt to transition manufacturing lines to produce low-cost, high-efficiency VSD RACs. Adopting these recommendations would reduce Egypt’s electricity consumption to 11 TWh in 2030 and 89 TWh in 2050—with corresponding carbon dioxide (CO2) emissions reductions and avoided generation capacity requirements compared to the baseline.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

American Homeowner Perceptions and Choices for Energy Efficiency: Summary of Technology Adoption – Census Division Level

In 2020 a nationwide survey of homeowners was conducted to determine what energy efficiency upgrades homeowners had made to their homes and which ones they would make in the near future. The survey also included results on respondent financials about energy efficiency home upgrades/retrofits and perceptions of the value of energy efficiency/who should support improving the energy efficiency of the residential sector. The Department of Energy’s goal for this survey is to inform ongoing work in the residential energy efficiency research portfolio on the human dimensions of residential energy systems transformation. In addition, DOE envisions this work supports efforts by industry, non-profits, and other government partners in informing programming, customer discovery, and policy writ large. This report provides a general summary of the nationwide results as they pertain to the following three issues: (1) how much did respondents indicate spending on energy efficiency-related home upgrades, (2) what upgrades/improvements had they made to their homes, and (3) which upgrades/improvements do they believe have the most significant impact on energy efficiency. The results provided are segmented by census division as specific regions demonstrated unique preferences for energy efficiency and willingness to expend family resources to achieve those goals. As such, the goal of this report is not to analyze the data nor draw cross-cutting conclusions but to serve as a resource for any groups interested in reviewing national trends about residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Covers J and K

Drainage structures are used in urban street and highway systems to capture stormwater runoff. These structures typically consist of catch basins fitted with grates, inlets, or combination grate/inlet configurations that collect runoff and convey it through buried drainage systems. They are strategically placed within curb-and-gutter systems to enhance public safety by efficiently removing water from roadways and thereby reducing the risk of hydroplaning. The performance of drainage structures is commonly evaluated in terms of hydraulic efficiency, defined as the percentage of flow captured by the basin relative to the total flow reaching the structure. Understanding the hydraulic performance of these structures allows designers to properly space inlets, resulting in cost-effective designs that also help ensure the safety of the traveling public. MDOT uses a variety of drainage structures for runoff capture, as documented in Michigan Department of Transportation (MDOT) Drainage Manual. Many of these structures incorporate sinusoidal-type grates that are not addressed in HEC-22. Because physical modeling of these structures has been limited, further analysis is needed to verify their capture efficiency. Under current MDOT practice, the capture efficiency of these grates is estimated by assuming performance similar to that of a comparably sized reticuline grate described in HEC22. The first phase of this effort, titled Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C, focused on evaluating the hydraulic performance of MDOT’s Cover C grate. Cover C was selected as the initial test candidate because its sinusoidal pattern is representative of other MDOT grates, while it is typically used in high-volume, higher-speed applications. A similar version, Cover CX, is used on interstate highways but does not include transverse bars for bicycle safety. The current second phase of the study expands this work to evaluate MDOT’s Covers J and K. These grates were selected for additional analysis to further assess the hydraulic performance of MDOT drainage structures that are not directly represented by grate configurations in HEC-22. The results of this phase will build on the findings from the Cover C analysis and support improved understanding of the capture efficiency of MDOT’s standard drainage grates. This report is intended to serve as a companion document to the earlier study, Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C [3]. The present work applies the same overall CFD-based evaluation approach to MDOT Covers J and K and compares the resulting performance trends with those previously identified for Cover C. In particular, both studies assess on-grade interception efficiency, sag-location hydraulic capacity, and the effects of partial obstruction relative to HEC-22-based design estimates.

42 ENGINEERING↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Historical perspective of barriers to achieving high-efficiency silicon solar cells

Early silicon solar cells were made of metallurgical-grade silicon with very low efficiency. The single-crystal silicon introduced in the mid-50's increased the efficiency to the 5% to 10% region. Throughout the 1960s the technology of the 2 x 2 cm or 2 x 4 cm space solar cell with 10% efficiency was established. In the early 1970s work related to the violet cell upset the status quo and space solar cells and cells in general became more efficient. The rest of the decade became characterized by establishing a terrestrial photovoltaic technology to support the development of a new industry. Costs per watt became the dominant consideration and frequently the efficiency was compromised. The introduction of materials and other forms of silicon dropped the efficiency and it is now a state of mine that accomplishing 10% efficiency with some alternative combination is regarded as success. Silicon solar cells are capable of delivering efficiences much greater than 10%.

Lindmayer, J.↗

High-efficiency heteroepitaxial InP solar cells

High-efficiency, thin-film InP solar cells grown heteroepitaxially on GaAs and Si single-crystal bulk substrates are being developed as a means of eliminating the problems associated with using single-crystal InP substrates. A novel device structure employing a compositionally graded Ga(x)In(1-x)As layer between the bulk substrate and the InP cell layers is used to reduce the dislocation density and improve the minority carrier properties in the InP. The structures are grown in a continuous sequence of steps using computer-controlled atmospheric pressure metalorganic vapor phase epitaxy (APMOVPE). Dislocation densities as low as 3 x 10(exp 7) sq cm and minority carrier lifetimes as high as 3.3 ns are achieved in the InP layers with this method using both GaAs or Si substrates. Structures prepared in this fashion are also completely free of microcracks. These results represent a substantial improvement in InP layer quality when compared to heteroepitaxial InP prepared using conventional techniques such as thermally cycled growth and post-growth annealing. The present work is is concerned with the fabrication and characterization of high-efficiency, thin-film InP solar cells. Both one-sun and concentrator cells were prepared for device structures grown on GaAs substrates. One-cell cells have efficiencies as high as 13.7 percent at 25 C. However, results for the concentrator cells are emphasized. The concentrator cell performance is characterized as a function of the air mass zero (AM0) solar concentration ratio and operating temperature. From these data, the temperature coefficients of the cell performance parameters are derived as a function of the concentration ratio. Under concentration, the cells exhibit a dramatic increase in efficiency and an improved temperature coefficient of efficiency. At 25 C, a peak conversion efficiency of 18.9 percent is reported. At 80 C, the peak AM0 efficiency is 15.7 percent at 75.6 suns. These are the highest efficiencies yet reported for InP heteroepitaxial cells. Approaches for further improving the cell performance are discussed.

Wanlass, M. W.↗

Optimization for efficient structure-control systems

The efficiency of a structure-control system is a nondimensional parameter which indicates the fraction of the total control power expended usefully in controlling a finite-dimensional system. The balance of control power is wasted on the truncated dynamics serving no useful purpose towards the control objectives. Recently, it has been demonstrated that the concept of efficiency can be used to address a number of control issues encountered in the control of dynamic systems such as the spillover effects, selection of a good input configuration and obtaining reduced order control models. Reference (1) introduced the concept and presented analyses of several Linear Quadratic Regulator designs on the basis of their efficiencies. Encouraged by the results of Ref. (1), Ref. (2) introduces an efficiency modal analysis of a structure-control system which gives an internal characterization of the controller design and establishes the link between the control design and the initial disturbances to affect efficient structure-control system designs. The efficiency modal analysis leads to identification of principal controller directions (or controller modes) distinct from the structural natural modes. Thus ultimately, many issues of the structure-control system revolve around the idea of insuring compatibility of the structural modes and the controller modes with each other, the better the match the higher the efficiency. A key feature in controlling a reduced order model of a high dimensional (or infinity-dimensional distributed parameter system) structural dynamic system must be to achieve high efficiency of the control system while satisfying the control objectives and/or constraints. Formally, this can be achieved by designing the control system and structural parameters simultaneously within an optimization framework. The subject of this paper is to present such a design procedure.

Oz, Hayrani↗

ARC and Melting Efficiency of Plasma ARC Welds

A series of partial penetration Variable Polarity Plasma Arc welds were made at equal power but various combinations of current and voltage on 2219 Aluminum. Arc efficiency was measured calorimetrically and ranged between 48% and 66% for the conditions of the welds. Arc efficiency depends in different ways on voltage and current. The voltage effect dominates. Raising voltage while reducing current increases arc efficiency. Longer, higher voltage arcs are thought to transfer a greater portion of arc power to the workpiece through shield gas convection. Melting efficiency depends upon weld pool shape as well as arc efficiency. Increased current increases the melting efficiency as it increases the depth to width ratio of the weld pool. Increased plasma gas flow does the same thing. Higher currents are thought to raise arc pressure and depress liquid at the bottom of the weld pool. More arc power then transfers to the workpiece through increasing plasma gas convection. If the power is held constant, the reduced voltage lowers the arc efficiency, while the pool shape change increases the melting efficiency,

McClure, J. C.↗