Shape evolution of the highly deformed {sup 75}Kr nucleus examined with the Doppler-shift attenuation method

High-spin states of the {sup 75}Kr nucleus have been populated via the {sup 50}Cr({sup 28}Si,2pn){sup 75}Kr reaction at an incident beam energy of 90 MeV. Lifetimes of nine states up to spin I=33/2 for the positive-parity band and seven states up to I=27/2 for the negative-parity band have been measured using the Doppler-shift attenuation method. The deduced transition quadrupole moments Q{sub t} of these bands have been compared to the projected shell-model calculations to gain insight into the evolution of collectivity for the two experimentally studied bands in {sup 75}Kr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atomic cascade of K{sup -}p and K{sup -}d atoms and Doppler broadening contribution on x-ray widths

In this article we present a new calculation of the cascade of K{sup -}p and K{sup -}d atoms by the Monte Carlo method. Energy dependence of the collisional cascade processes is taken into account. The x-ray yields due to the radiative transition during the cascade are also calculated. We compare our results with the previous calculations by others and by KEK and DEAR experimental data for K{sup -}p atoms. We have also investigated the kinetic energy distribution of K{sup -}p atoms and the role of Coulomb transition on x-ray yields. Finally, the Doppler broadening contribution on the measured width of x-ray spectra are determined. In order to study the strong interaction in low energies, our results for x-ray yields from K{sup -}p and K{sup -}d atoms can be compared with the forthcoming SIDDHARTA collaboration results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resampling technique to correct for the Doppler effect in a search for gravitational waves

The frequency of any gravitational-wave signal received from a spinning neutron star will appear Doppler-shifted by the Earth's rotation and orbital motion. This frequency shift must be compensated to recover the signal energy as a spectral monochromatic peak with a high signal-to-noise ratio. Generally the correction depends on the source's position in the sky, spin, and spin-down rate. Here we propose a method of applying a single correction to the data which is valid for all the emission frequencies at a fixed position in the sky and for a given spin-down rate. We advance or retard the antenna proper time by removing (or repeating) single samples of the digitized output signal to keep the effective receiver and source clocks in accurate synchronization. The method, which requires just a few lines of code and little computational effort, appears to be very effective for ''semitargeted'' searches, where the source direction is known but the emission frequency is not.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler Spectrometry for Ultrafast Temporal Mapping of Density Dynamics in Laser-Induced Plasmas

We present high resolution measurements of the ultrafast temporal dynamics of the critical surface in moderately overdense, hot plasma by using two-color, pump-probe Doppler spectrometry. Our measurements clearly capture the initial inward motion of the plasma inside the critical surface of the pump laser which is followed by outward expansion. The measured instantaneous velocity and acceleration profiles are very well reproduced by a hybrid simulation that uses a 1D electromagnetic particle-in-cell simulation for the initial evolution and a hydrodynamics simulation for the later times. The combination of high temporal resolution and dynamic range in our measurements clearly provides quantitative unraveling of the dynamics in this important region, enabling this as a powerful technique to obtain ultrafast snapshots of plasma density and temperature profiles for providing benchmarks for simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of a Doppler-Free Saturation Spectroscopy (DFSS) Diagnostic for Helicon Wave Electric Field Vector Measurement in Edge Plasma in DIII-D

A laser-based technique known as Doppler-free saturation spectroscopy (DFSS) has been designed, fabricated, and installed on the DIII-D National Fusion Facility to measure the helicon wave electric field vector in the edge plasma. These experimental measurements quantify phenomena resulting in decreased current drive efficiency due to wave/edge plasma interactions. This implementation of DFSS on DIII-D is the first of its kind on a tokamak and thus presents unique engineering challenges, including integration of the system onto an existing multidiagnostic port flange without impacts to system serviceability, as well as maintaining precise laser alignment over a 2-m distance during disruptions and thermal drift of the vessel. Further, these challenges were resolved using innovative design approaches such as a novel decoupled shutter system to facilitate serviceability of the in-vessel mirror assemblies without the need for personnel vessel entry, as well as an ex-vessel piezo-mirror-based optical system for laser beam shaping and real-time steering of the measurement location. The solutions to these engineering challenges were demonstrated during the successful installation and operation of these diagnostic components during the 2022 DIII-D vent and subsequent experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Note: Improved implementation of doppler broadening in MCNP5

Purpose: Incoherent scattering has a substantial effect on spectroscopic measurements and simulations. Many general-purpose Monte Carlo codes include models that account for the effects of bound electrons on incoherent scattering, including Doppler broadening (DB). This work investigates the DB model used in the Monte Carlo N-particle transport code (MCNP5). Methods: Simulations were run with three versions of MCNP5: v1.51, v1.60, and a modified form of v1.60 (v1.60m). All simulations used the MCPLIB04 photon data library, which presents the electron subshell data for incoherent scattering in the form of a probability density function. In v1.60m, the source code was altered to sample the electron subshell from a cumulative density function instead. Each version of the code was tested using an identical set of simulations that investigated DB in a slab of silicon at scattering angles of 15 Degree-Sign , 30 Degree-Sign , and 45 Degree-Sign . For each angle, simulations were run for multiple energies between 200 keV and 800 keV. The spectrum of singly-scattered photons at the exit of the slab was scored. Spectra were analytically calculated for comparison. Results: In v1.51, DB was modeled for incident photon energies below 760 keV, 384 keV, and 260 keV at scattering angles of 15 Degree-Sign , 30 Degree-Sign , and 45 Degree-Sign , respectively. Above these energy thresholds, v1.51 did not model DB. The spectra calculated using v1.60 and v1.60m exhibited DB for all energy-angle combinations; however, v1.60m, exhibited more energy broadening than did v1.60. The spectra calculated with v1.60m agreed with the analytical calculations. Conclusions: MCNP5 v1.51 and v1.60 model partial broadening when used with the MCPLIB04 data library. MCNP5 v1.60m models DB more accurately due to the form of the electron subshell data. In response to these results, Los Alamos National Laboratory has released a new photon data library, MCPLIB84, that presents the electron subshell data in cumulative distribution form. MCNP5 v1.60 should be used with this library when incoherent scattering has a significant impact on simulation results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras

Purpose: The authors investigated how the characteristics of the detectors used in a three-stage Compton camera (CC) affect the CC's ability to accurately measure the emission distribution and energy spectrum of prompt gammas (PG) emitted by nuclear de-excitations during proton therapy. The detector characteristics they studied included the material (high-purity germanium [HPGe] and cadmium zinc telluride [CZT]), Doppler broadening (DB), and resolution (lateral, depth, and energy). Methods: The authors simulated three-stage HPGe and CZT CCs of various configurations, detecting gammas from point sources with energies ranging from 0.511 to 7.12 MeV. They also simulated a proton pencil beam irradiating a tissue target to study how the detector characteristics affect the PG data measured by CCs in a clinical proton therapy setting. They used three figures of merit: the distance of closest approach (DCA) and the point of closest approach (PCA) between the measured and actual position of the PG emission origin, and the calculated energy resolution. Results: For CCs with HPGe detectors, DB caused the DCA to be greater than 3 mm for 14% of the 6.13 MeV gammas and 20% of the 0.511 MeV gammas. For CCs with CZT detectors, DB caused the DCA to be greater than 3 mm for 18% of the 6.13 MeV gammas and 25% of the 0.511 MeV gammas. The full width at half maximum (FWHM) of the PCA in the z-caret direction for HPGe and CZT detectors ranged from 1.3 to 0.4 mm for gammas with incident energy ranging from 0.511 to 7.12 MeV. For CCs composed of HPGe detectors, the resolution of incident gamma energy calculated by the CC ranged from 6% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For CCs composed of CZT detectors, the resolution of gamma energy calculated by the CC ranged from 10% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For HPGe and CZT CCs in which all detector effect were included, the DCA was less than 3 mm for 75% and 68% of the detected gammas, respectively, and restricting gammas to those having energy greater than 2.0 MeV increased these percentages to 83% and 77% for HPGe and CZT, respectively. Distributions of the true gamma origins and the PCA after detector characteristics had been included showed good agreement on beam range and some loss of resolution for the lateral profile of the PG emission. Characteristic energy lines were evident in the calculated gamma energy spectrum. Conclusions: The authors found the following: (1) DB is the dominant source of spatial and energy resolution loss in the CCs at all energy levels; (2) the largest difference in the spatial resolution of HPGe and CZT CCs is that the spatial resolution distributions of CZT have broader tails. The differences in the FWHM of these distributions are small; (3) the energy resolution of both HPGe and CZT three-stage CCs is adequate for PG spectroscopy; and (4) restricting the gammas to those having energy greater than 2.0 MeV can improve the achievable image resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Sub-Doppler Spectroscopy of Optically Excited Atoms in a Thin Gas Cell

This work continues a theoretical investigation of the capabilities of the well-known method based on using a monochromatic probe light beam in combination with optical pumping of atoms (molecules) of a rarefied-gas medium by a broadband radiation in a thin cell the diameter of which is much larger than its internal thickness. In contrast to calculations carried out in the previous publications on this method of spectroscopy, here, we consider the case of arbitrary values of pump intensity and thickness of a cylindrical gas cell. Thus, all the possible mechanisms and specificities of velocity selection of atoms in optically excited levels caused by transit-time relaxation of such atoms in gas cells of this kind are analyzed. Within the framework of this approach, sub-Doppler absorption resonances of the probe light beam corresponding to quantum transitions from the upper level excited by optical pumping are investigated. The obtained results can be used in high-resolution spectroscopy of atoms (molecules), as well as for laser-frequency stabilization to established narrow spectral resonances.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurements of nuclear-level lifetimes by the Doppler techniques with large multidetector arrays

This is a brief review of the investigations carried out by scientists from the Ioffe Physical-Technical Institute (St. Petersburg) within the framework of international projects for the study of the structure of high-spin nuclear states using heavy-ion beams and arrays of tens and hundreds of detectors for recording gamma rays and charged particles. The development and results of measurements of nuclear-level lifetime by Doppler techniques in the range 10{sup -14}-10{sup -9} s are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TREND code for reconstruction of neutron reaction cross sections and calculation of the Doppler broadening in the region of resolved resonances

The TREND code is developed for reconstruction of neutron cross sections in the region of resolved resonances from the data of the international evaluated nuclear data libraries using the Reich-Moore, Adler-Adler, and Breit-Wigner formalisms and for calculation of the Doppler broadening of the resulting cross sections within the classical approximation. The TREND code is incorporated into the MCU code package for Monte Carlo reactor calculations. The TREND and MCU codes have been used to evaluate the data of the ROSFOND data bank on uranium and plutonium isotopes in comparison with the data of the ICSBEP data bank.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coplanar Doppler Lidar Retrieval of Rotors from T-REX

Two coherent Doppler lidars were deployed during the Terrain-induced Rotor EXperiment (T-REX). Coplanar Range Height Indicator (RHI) scans by the lidars (along the same azimuthal angle) allowed retrieval of two-dimensional velocity vectors on a vertical/cross-barrier plane using the least squares method. Vortices are shown to evolve and advect in the flow field, allowing analysis of their behavior in the mountain-wave-boundary layer system. The locations, magnitudes, and evolution of the vortices can be studied through calculated fields of velocity, vorticity, streamlines, and swirl. Two classes of vortical motions are identified: rotors and sub-rotors, which differ in scale and behavior. The level of coordination of the two lidars and the nature of the output (i.e., in range-gates) creates inherent restrictions on the spatial and temporal resolution of retrieved fields.

54 ENVIRONMENTAL SCIENCES↗

Wind Measurements from Arc Scans with Doppler Wind Lidar

When defining optimal scanning geometries for scanning lidars for wind energy applications, we found that it is still an active field of research. Our paper evaluates uncertainties associated with arc scan geometries and presents recommendations regarding optimal configurations in the atmospheric boundary layer. The analysis is based on arc scan data from a Doppler wind lidar with one elevation angle and seven azimuth angles spanning 30° and focuses on an estimation of 10-min mean wind speed and direction. When flow is horizontally uniform, this approach can provide accurate wind measurements required for wind resource assessments in part because of its high resampling rate. Retrieved wind velocities at a single range gate exhibit good correlation to data from a sonic anemometer on a nearby meteorological tower, and vertical profiles of horizontal wind speed, though derived from range gates located on a conical surface, match those measured by mast-mounted cup anemometers. Uncertainties in the retrieved wind velocity are related to high turbulent wind fluctuation and an inhomogeneous horizontal wind field. Moreover, the radial velocity variance is found to be a robust measure of the uncertainty of the retrieved wind speed because of its relationship to turbulence properties. It is further shown that the standard error of wind speed estimates can be minimized by increasing the azimuthal range beyond 30° and using five to seven azimuth angles.

17 WIND ENERGY↗

Laser Doppler vibrometer employing active frequency feedback

We present a heterodyne Michelson interferometer for vibration measurement in which feedback is used to obviate the need to unwrap phase data. The Doppler shift of a vibrating target mirror is sensed interferometrically and compensated by means of a voltage-controlled oscillator driving an acousto-optic modulator. For frequencies within the servo bandwidth, the oscillator control voltage provides a direct measurement of the target velocity. Outside the servo bandwidth, phase-sensitive detection is used to evaluate high-frequency displacements. This approach is of great interest for the frequently-occurring situation where vibration amplitudes at low frequency exceed an optical wavelength, but knowledge of the vibration spectrum at high frequency is important as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bragg cell laser intensity modulation: effect on laser Doppler velocimetry measurements

In most laser Doppler velocimetry (LDV) systems, the frequency of one of the two laser beams that intersect to create the probe volume is shifted with an acousto-optic element. It is shown here that Bragg shifting can impose a problematic fluctuation in intensity on the frequency-shifted beam, producing spurious velocity measurements. This fluctuation occurs at twice the Bragg cell frequency, and its relative amplitude to the time average intensity is a function of the ratio of the laser beam diameter to the Bragg cell acoustic wavelength. A physical model and a configuration procedure to minimize adverse effects of the intensity modulations are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective optical pumping process in Doppler-broadened atoms

By solving the optical Bloch equations with the rate-equation approximation, we calculate the time dependence of the magnetic sublevel populations of Doppler-broadened atoms. With an increase of the left-circularly polarized pump intensity, the population fraction of a certain sublevel of the excited state almost reaches 0.3, resulting in anisotropy in the excited state, which is important to the optical filter based on circular birefringence and dichroism. Furthermore, numerical results show that the real saturation pump intensity for the moving atoms is much larger than that for the resting atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Scattering effects at near-wall flow measurements using Doppler global velocimetry

Doppler global velocimetry (DGV) is considered to be a useful optical measurement tool for acquiring flow velocity fields. Often near-wall measurements are required, which is still challenging due to errors resulting from background scattering and multiple-particle scattering. Since the magnitudes of both errors are unknown so far, they are investigated by scattering simulations and experiments. Multiple-particle scattering mainly causes a stochastic error, which can be reduced by averaging. Contrary to this, background scattering results in a relative systematic error, which is directly proportional to the ratio of the background scattered light power to the total scattered light power. After applying a correction method and optimizing the measurement arrangement, a subsonic flat plate boundary layer was successfully measured achieving a minimum wall distance of 100 {mu}m with a maximum relative error of 6%. The investigations reveal the current capabilities and perspectives of DGV for near-wall measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pacific Marine Energy Center Laser Doppler Velocimetry Commissioning

First commissioning data for the new laser doppler velocimetry (LDV) system that will be used at the Tyler Flume at the University of Washington. The LDV system can measure three components of velocity at a point. For this dataset the three components were operated in non-coincident mode and data were acquired at the center of the empty facility. Comparisons of freestream turbulence were made with a Vectrino slightly upstream of the LDV measurement location.

16 TIDAL AND WAVE POWER↗

Microscale Heat Conduction Models and Doppler Feedback

The objective of this project is to establish an approach for providing the fundamental input that is needed to estimate the magnitude and time-dependence of the Doppler feedback mechanism in Very High Temperature reactors. This mechanism is the foremost contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic (TRISO) coated particles. Therefore, its correct prediction is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat deposition, heat transfer and temperature rise must be correctly predicted. To achieve the above objective, this project will explore an approach that accounts for lattice effects as well as local temperature variations and the correct definition of temperature and related local effects.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗