Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Evaluation of a far infrared Ge:Ga multiplexed detector array

The performance of a multielement Ge:Ga linear array under low-background conditions is investigated. On-focal plane switching is accomplished by MOSFET switches and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the responsivity was measured to be nominally 584 A/W, and the NEP was 1.0 x 10 exp -16 W/sq rt Hz. A detailed description of the test setup and the procedure is presented.

Farhoomand, Jam↗

Integrating indium antimonide linear arrays at 65K and below

A schematic is presented of a simplified electronic architecture of experimental 128 element infrared imager. Tables are given of sample diode responsivity, 512 element focal plane performance summary, and 128 element FPA mechanical and electrical characteristics. Typical 43 x 43 micron detector IV characteristics at 84 K are given, along with typical 43 x 43 micron Indium Antimonide CV characteristic at 83 K.

Bailey, Gary C.↗

Comparison of the EO-1 Advanced Land Imager Performance With the Landsat Data Continuity Mission Specification

The performance requirements for the Advanced Land Imager were developed under NASA's New Millennium Program and were intended to facilitate the validation of new sensor technologies and architectures for potential application in future remote sensing missions. The Advanced Land Imager (ALI) was designed and flown well before the Landsat Data Continuity Mission (LDCM) specifications were developed. Nevertheless, the science focus of the ALI technology validation was Landsat data continuity. Therefore, although exact compliance by ALI is not expected, the performance should demonstrate a path to a compliant sensor system. The performance of the ALI, as determined from preflight and flight data, is compared to the LDCM specification. Twenty-one noncompliances have been identified: four data collection, four spectral, six spatial, and seven radiometric (Table I). All but six of these are considered minor. The six major noncompliances are the result of stray light, leaky detectors, and contamination. Appendix A replicates the LDCM specification and contains ALI compliance notes where appropriate. Details of the ALI stray light, contamination, and leaky detectors are provided in Appendix B, C, and D respectively. Additional information pertaining to the calculation of the ALI edge response and coherent noise is presented in Appendix E and F. A list of ALI related publications is provided in Appendix G.

Mendenhall, J. A.↗

Complementary Barrier Infrared Detector (CBIRD) with Double Tunnel Junction Contact and Quantum Dot Barrier Infrared Detector (QD-BIRD)

The InAs/GaSb type-II superlattice based complementary barrier infrared detector (CBIRD) has already demonstrated very good performance in long-wavelength infrared (LWIR) detection. In this work, we describe results on a modified CBIRD device that incorporates a double tunnel junction contact designed for robust device and focal plane array processing. The new device also exhibited reduced turn-on voltage. We also report results on the quantum dot barrier infrared detector (QD-BIRD). By incorporating self-assembled InSb quantum dots into the InAsSb absorber of the standard nBn detector structure, the QD-BIRD extend the detector cutoff wavelength from approximately 4.2 micrometers to 6 micrometers, allowing the coverage of the mid-wavelength infrared (MWIR) transmission window. The device has been observed to show infrared response at 225 K.

antimonide↗

Development of Mirror Modules for the ART-XC Instrument aboard the Spectrum-Roentgen-Gamma Mission

The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART-XC instrument on board the Spectrum-Roentgen Gamma Mission. Four of those modules are being fabricated under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) An additional three flight modules and one spare for the ART-XC Instrument are produced under a Cooperative Agreement between NASA and IKI. The instrument will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Each module consists of 28 nested thin Ni/Co shells giving an effective area of 65 cm2 at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. Delivery of the first four modules is scheduled for November 2013, while the remaining three modules will be delivered to IKI in January 2014. We present a status of the ART x-ray module development at MSFC.

Gubarev, M↗

QWIPs, SLS, Landsat and the International Space Station

In 1988 DARPA provided funding to NASA’s Goddard Space Flight Center to support the development of GaAs Quantum Well Infrared Photodetectors (QWIP). The goal was to make a single element photodetector that might be expandable to a two-dimensional array format. Ultimately, this led to the development of a 128 x 128 element array in collaboration with AT&T Bell Labs and Rockwell Science Center in 1990. We continued to develop numerous generations of QWIP arrays most recently resulting in the multi-QWIP focal plane for the NASA-US Geological Survey (USGS) Landsat 8 mission launched in 2013 and a similar instrument on the Landsat 9 mission to be launched in 2020. Toward the end of the Landsat 8 QWIP-based Thermal Infrared Sensor (TIRS) instrument the potential of the newly developed Strained Layer Superlattice (SLS) detector array technology became of great interest to NASA for three primary reasons: 1) higher operating temperature; 2) broad spectral response and; 3) higher sensitivity. We have collaborated extensively with QmagiQ, LLC and Northwestern University to further pursue and advance the SLS technology ever since we started back in 2012. In December of 2018 we launched the first SLS-based IR camera system to the International Space Station on board the Robotic Refueling Mission #3 (RRM3). This paper will describe the evolution of QWIP technology leading to the current development of SLS-based imaging systems at the Goddard Space Flight Center over the past 30 years.

Jhabvala, M.↗

Swift/UVOT Follow-Up of Gravitational Wave Alerts in the O3 Era

In this paper, we report on the observational performance of the Swift Ultra-violet/Optical Telescope (UVOT) in response to the gravitational wave (GW) alerts announced by the Advanced Laser Interferometer Gravitational Wave Observatory and the Advanced Virgo detector during the O3 period. We provide the observational strategy for follow-up of GW alerts and provide an overview of the processing and analysis of candidate optical/UV sources. For the O3 period, we also provide a statistical overview and report on serendipitous sources discovered by Swift/UVOT. Swift followed 18 GW candidate alerts, with UVOT observing a total of 424 deg2. We found 27 sources that changed in magnitude at the 3σ level compared with archival u- or g-band catalogued values. Swift/UVOT also followed up a further 13 sources reported by other facilities during the O3 period. Using catalogue information, we divided these 40 sources into five initial classifications: 11 candidate active galactic nuclei (AGNs)/quasars, three cataclysmic variables (CVs), nine supernovae, 11 unidentified sources that had archival photometry, and six uncatalogued sources for which no archival photometry was available. We have no strong evidence to identify any of these transients as counterparts to the GW events. The 17 unclassified sources are likely a mix of AGN and a class of fast-evolving transient, and one source may be a CV.

gravitational waves↗

Quantum Well Infrared Photodetectors (QWIP)

There has been a lot of interest in III-V long wavelength detectors in the lambda = 8 to 12 micron spectral range as alternatives to HgCdTe. Recently high performance quantum well infrared photodetectors (QWIP) have been demonstrated. They have a responsivity of R = 1.2 A/W, and a detectivity D(exp asterisk) sub lambda = 2 times 10(exp 10) cm Hz(exp 1/2)/W at 68 K for a QWIP with a cutoff wavelength of lambda sub c = 10.7 micron and a R = 1.0 A/W, and D(exp asterisk) sub lambda = 2 times 10(exp 10) cm Hz(exp 1/2)/W at T = 77 K for lambda sub c = 8.4 micron. These detectors consist of 50 periods of molecular beam epitaxy (MBE) grown layers doped n = 1 times 10(exp 18)cm(exp -3) having GaAs quantum well widths of 40 A and barrier widths of 500 A of Al sub x Ga sub 1-x As. Due to the well-established GaAs growth and processing techniques, these detectors have the potential for large, highly uniform, low cost, high performance arrays as well as monolithic integration with GaAs electronics, high speed and radiation hardness. Latest results on the transport physics, device performance and arrays are discussed.

Levine, B. F.↗

Prelaunch Spectral Characterization of the Operational Land Imager-2

The Landsat-9 satellite, launched in September 2021, carries the Operational Land Imager-2 (OLI-2) as one of its payloads. This instrument is a clone of the Landsat-8 OLI and its mission is to continue the operational land imaging of the Landsat program. The OLI-2 instrument is not significantly different from OLI though the instrument-level pre-launch spectral characterization process was much improved. The focal plane modules used on OLI-2 were manufactured as spares for OLI and much of the spectral characterization of the components was performed for OLI. However, while the spectral response of the fully assembled OLI was characterized by a double monochromator system, the OLI-2 spectral characterization made use of the Goddard Laser for Absolute Measurement of Radiance (GLAMR). GLAMR is a system of tunable lasers that cover 350–2500 nm which are fiber-coupled to a 30 in integrating sphere permanently monitored by NIST-traceable radiometers. GLAMR allowed the spectral characterization of every detector of the OLI-2 focal plane in nominal imaging conditions. The spectral performance of the OLI-2 was, in general, much better than requirements. The final relative spectral responses (RSRs) represent the best characterization any Landsat instrument spectral response. This paper will cover the results of the spectral characterization from the component-level to the instrument-level of the Landsat-9 OLI-2.

Landsat-9↗

Multiple Waveband Temperature Sensor (MWTS)

This slide presentation reviews the development of Multiple Waveband Temperature Sensor (MWTS). The MWTS project will result in a highly stable, monolithically integrated, high resolution infrared detector array sensor that records registered thermal imagery in four infrared wavebands to infer dynamic temperature profiles on a laser-irradiated ground target. An accurate surface temperature measurement of a target in extreme environments in a non-intrusive manner is required. The development challenge is to: determine optimum wavebands (suitable for target temperatures, nature of the targets and environments) to measure accurate target surface temperature independent of the emissivity, integrate simultaneously readable multiband Quantum Well Infrared Photodetectors (QWIPs) in a single monolithic focal plane array (FPA) sensor and to integrate the hardware/software and system calibration for remote temperature measurements. The charge was therefore to develop and demonstrate a multiband infrared imaging camera with the detectors simultaneously sensitive to multiple distinct color bands for front surface temperature measurements Wavelength ( m) measurements. Amongst the requirements are: that the measurement system will not affect target dynamics or response to the laser irradiation and that the simplest criterion for spectral band selection is to choose those practically feasible spectral bands that create the most contrast between the objects or scenes of interest in the expected environmental conditions. There is in the presentation a review of the modeling and simulation of multi-wave infrared temperature measurement and also a review of the detector development and QWIP capacities.

infrared photodector↗

An Analysis Method for Superconducting Resonator Parameter Extraction with Complex Baseline Removal

A new semi-empirical model is proposed for extracting the quality (Q) factors of arrays of superconducting microwave kinetic inductance detectors (MKIDs). The determination of the total internal and coupling Q factors enables the computation of the loss in the superconducting transmission lines. The method used allows the simultaneous analysis of multiple interacting discrete resonators with the presence of a complex spectral baseline arising from reflections in the system. The baseline removal allows an unbiased estimate of the device response as measured in a cryogenic instrumentation setting.

semi-empirical model↗

Development of improved pyroelectric detectors; Literature survey of pyroelectric materials and their characteristics

The object of this program is to improve the detectivity of the pyroelectric detector with the ultimate goal of operation at or near the temperature-noise limit. Two general areas of investigation are undertaken. The first is to improve responsivity through the use of new materials. The second is directed toward reduction of noise and will be effected with improved field effect transistor characteristics, and improved electroding of the pyroelectric material. The search for new materials has begun with a review of the literature on pyroelectric materials in several languages. The compiled data includes an extensive list of references. From this, several materials have already been selected for investigation. FETs are being obtained from various manufacturers, evaluated, and selected units will be tested with pyroelectric elements as complete detectors.

Weiner, S.↗

On Orbit Measurement of Response vs. Scan Angle for the Infrared Bands on TRMM/VIRS

The Visible and Infrared Scanner on the Tropical Rainfall Measuring Mission (TRMM/VIRS) is a whiskbroom imaging radiometer with two reflected solar bands and three emissive infrared bands. All five detectors are on a single cooled focal plane. This configuration necessitated the use of a paddlewheel scan mirror to avoid the effects of focal plane rotation that arise when using a scan mirror that is inclined to its axis of rotation. System radiometric requirements led to the need for protected silver as the mirror surface. Unfortunately, the SiO(x) coatings currently used to protect silver from oxidation introduce a change in reflectance with angle of incidence (AOI). This AOI dependence results in a modulation of system level response with scan angle. Measurement of system response vs. scan angle (RVS) was not difficult for the VIRS reflected solar bands, but attaining the required accuracy for the IR bands in the laboratory was not possible without a large vacuum chamber and a considerable amount of custom designed testing apparatus. Therefore, the decision was made to conduct the measurement on-orbit. On three separate occasions, the TRMM spacecraft was rotated about its pitch axis and, after the nadir view passed over the Earth's limb, the VIRS performed several thousand scans while viewing deep space. The resulting data has been analyzed and the RVS curves generated for the three IR bands are being used in the VIRS radiometric calibration algorithm. This, to our knowledge, the first time this measurement has been made on-orbit. Similar measurements are planned for the EOS-AM and EOS-PM MODIS sensors and are being considered for several systems under development. The VIRS on-orbit results will be compared to VIRS and MODIS system level laboratory measurements, MODIS scan mirror witness sample measurements and modeled data.

Barnes, William L.↗

Rapid-response, light-exposure control system

Rapid-response electro-optical, light exposure control system, will maintain the light reaching a camera film or other light-sensitive detector at essentially constant level, despite wide variations in the brightness of the light source. The system permits detailed photographic or photoelectric recording of the phenomenon over a range of brightnesses.

Kuehl, D. K.↗

Hydrogen detection study

The effectiveness was assessed of a hydrogen (H2) detection concept for regenerative environmental control life support systems (EC/LSS). The concept evaluated was that utilized for the electrochemical depolarized concentrator (EDC) design, constructed, and tested for the EC/LSS space station prototype program. The EDC contains combustible gas detectors (CGDs) which were evaluated with H2. The CGDs were evaluated for linearity, position sensitivity, reproducibility, ambient effects, repeatability, speed of response, recovery time, and interchangeability. The effectiveness of CGDs located within the EDC for sensing H2 leaks at various line replaceable units in the subsystem was determined. The effects of H2 leak rate, H2 concentration of leaking gas and air currents in the vicinity of the EDC were determined. Proposed improvements for the H2 detection concept were documented and alternative H2 detection approaches were identified and analyzed.

Shumar, J. W.↗

Calibration of the ISEE plasma composition experiment

The Plasma Composition experiment on the ISEE-1 satellite was designed to measure ions from 1 to 16 amu, at energies from near zero to 16 keV. The two nearly identical flight instruments were calibrated by means of preflight laboratory tests and in-flight data comparisons. This document presents most of the details of those efforts, with special emphasis on the low energy (0 to 100 eV) portion of the instrument response. The analysis of the instrument includes a ray-tracing calculation, which follows an ensemble of test particles through the detector.

Baugher, C. R.↗

Performance of multiplexed Ge:Ga detector arrays in the far infrared

The performance of two multi-element, multiplexed Ge:Ga linear arrays under low-background conditions was investigated. The on-focal switching is accomplished by MOSFET switches, and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns, and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the highest responsivity was 584 A/W, the noise equivalent power was 1.0 x 10(exp -16) W/square root of Hz, and the read noise was 6100 electrons/sample. A detailed description of the test setup and procedure is presented.

Farhoomand, Jam↗

Doppler lidar wind measurement with the edge technique

The edge technique is a new and powerful method for measuring small frequency shifts. Range resolved lidar measurements of winds can be made with high accuracy and high vertical resolution using the edge technique to measure the Doppler shift of an atmospheric backscattered signal from a pulsed laser. The edge technique can be used at near-infrared or visible wavelengths using well developed solid state lasers and detectors with various edge filters. In the edge technique, the laser frequency is located on the steep slope of the spectral response function of a high resolution optical filter. Due to the steep slope of the edge, very small frequency shifts cause large changes in measured signal. The frequency of the outgoing laser pulse is determined by measuring its location on the edge of the filter. This is accomplished by sending a small portion of the beam to the edge detection setup where the incoming light is split into two channels - an edge filter and an energy monitor channel. The energy monitor signal is used to normalize the edge filter signal for magnitude. The laser return backscattered from the atmosphere is collected by a telescope and directed through the edge detection setup to determine its frequency (location on the edge) in a similar manner for each range element. The Doppler shift, and thus the wind, is determined from a differential measurement of the frequency of the outgoing laser pulse and the frequency of the laser return backscattered from the atmosphere. We have conducted simulations of the performance of an edge lidar system using an injection seeded pulsed Nd:YAG laser at 1.06 microns. The central fringe of a Fabry-Perot etalon is used as a high resolution edge filter to measure the shift of the aerosol return.

Korb, C. Laurence↗