Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Statistical precision of the intensities retrieved from constrained fitting of overlapping peaks in high-resolution mass spectra

Least-squares fitting of overlapping peaks is often needed to separately quantify ions in high-resolution mass spectrometer data. A statistical simulation approach is used to assess the statistical precision of the retrieved peak intensities. The sensitivity of the fitted peak intensities to statistical noise due to ion counting is probed for synthetic data systems consisting of two overlapping ion peaks whose positions are pre-defined and fixed in the fitting procedure. The fitted intensities are sensitive to imperfections in the m/Q calibration. These propagate as a limiting precision in the fitted intensities that may greatly exceed the precision arising from counting statistics. The precision on the fitted peak intensity falls into one of three regimes. In the "counting-limited regime" (regime I), above a peak separation &chi; ~ 2 to 3 half-widths at half-maximum (HWHM), the intensity precision is similar to that due to counting error for an isolated ion. For smaller &chi; and higher ion counts (~ 1000 and higher), the intensity precision rapidly degrades as the peak separation is reduced ("calibration-limited regime", regime II). Alternatively for &chi; < 1.6 but lower ion counts (e.g. 10–100) the intensity precision is dominated by the additional ion count noise from the overlapping ion and is not affected by the imprecision in the m/Q calibration ("overlapping-limited regime", regime III). The transition between the counting and m/Q calibration-limited regimes is shown to be weakly dependent on resolving power and data spacing and can thus be approximated by a simple parameterisation based only on peak intensity ratios and separation. A simple equation can be used to find potentially problematic ion pairs when evaluating results from fitted spectra containing many ions. Longer integration times can improve the precision in regimes I and III, but a given ion pair can only be moved out of regime II through increased spectrometer resolving power. As a result, studies presenting data obtained from least-squares fitting procedures applied to mass spectral peaks should explicitly consider these limits on statistical precision.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Fast Charging Station Network for Electrified Ride-Hailing Services

Today's electric vehicle (EV) owners charge their vehicles mostly at home and seldom use public direct current fast charger (DCFCs), reducing the need for a large deployment of DCFCs for private EV owners. However, due to the emerging interest among transportation network companies to operate EVs in their fleet, there is great potential for DCFCs to be highly utilized and become economically feasible in the future. This paper describes a heuristic algorithm to emulate operation of EVs within a hypothetical transportation network company fleet using a large global positioning system data set from Columbus, Ohio. DCFC requirements supporting operation of EVs are estimated using the Electric Vehicle Infrastructure Projection tool. Operation and installation costs were estimated using real-world data to assess the economic feasibility of the recommended fast charging stations. Results suggest that the hypothetical transportation network company fleet increases daily vehicle miles traveled per EV with less overall down time, resulting in increased demand for DCFC. Sites with overhead service lines are recommended for hosting DCFC stations to minimize the need for trenching underground service lines. A negative relationship was found between cost per unit of energy and fast charging utilization, underscoring the importance of prioritizing utilization over installation costs when siting DCFC stations. Although this preliminary analysis of the impacts of new mobility paradigms on alternative fueling infrastructure requirements has produced several key results, the complexity of the problem warrants further investigation.

33 ADVANCED PROPULSION SYSTEMS↗

Demonstration of the On-the-Fly Shielding Analysis Method: Spent Fuel and Waste Disposition

This report documents work performed supporting the US Department of Energy (DOE) Office of Nuclear Energy (NE) Spent Fuel and Waste Disposition (SFWD) Integrated Waste Management activities under work breakdown structure element 1.08.02.04.01, “Data and Tools Development, Validation, and Maintenance.” In particular, this report fulfills milestone M3SF-21OR020401016, “Implement on-the-fly dose analysis methodology in UNF-ST&DARDS” within work package SF-21OR02040101, “Commercial SNF Characterization - ORNL.” The Used Nuclear Fuel - Storage, Transportation & Disposal Analysis Resource and Data System (UNFST& DARDS) enables automated dose rate calculations for spent nuclear fuel (SNF) transportation packages and storage casks using a Monte Carlo radiation transport code. The explicit method uses a detailed model of the SNF system and its contents. Therefore, a dose rate calculation is required for each as-loaded transportation package or storage cask because the SNF assemblies within a canister typically have unique irradiation characteristics. An alternate method, referred to as the “on-the-fly” shielding analysis method, has been proposed that requires only a set of Monte Carlo dose rate calculations for each transportation packaging/storage cask design. The results of the Monte Carlo dose rate calculations are independent of the SNF assembly irradiation and decay characteristics. The dose rate values may then be combined with the radiation source strength of the SNF assemblies associated with a particular transportation packaging/storage cask design to determine actual dose rates. This report presents on-the-fly dose rate calculations for a representative SNF storage cask and verification of the on-the-fly dose rate calculation results by comparison with reference dose rate calculations using the explicit Monte Carlo dose rate calculation. The on-the-fly shielding analysis method was implemented in UNF-ST&DARDS. A Python program was developed to process the MAVRIC dose rate results obtained by source particle type, energy group, and fuel geometry region. A Python processor created binary files, which were saved as a special UNF-ST&DARDS library for on-the- fly shielding analyses. UNF-ST&DARDS uses the precalculated on-the-fly binary libraries generated by the Python data processor and directly executes the Python code for on-the-fly dose analysis. This Python code unzips the pre-generated binary files mentioned above, reads the data, and combines them with user-specified sources for dose and uncertainty calculations. The Python programs were verified using Excel calculations and by comparison with the values obtained with the MAVRIC post-processing utilities applied to the 3dmap files. This method can currently be used to determine dose rates for as-loaded HI-STORM FW storage casks. The UNF-ST&DARDS analysis wizard for on-the-fly shielding analysis is described in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis framework for systematically studying ionospheric response to impulsive events from below: Analysis Framework Ionospheric Responses

We present that impulsive phenomena in the Earth's atmosphere produce acoustic and gravity waves which perturb the ionosphere. Such perturbations are often measured using total electron content fluctuations (TEC), derived from ground-based Global Positioning System data. Using TEC data from the Japanese GEONET ground network after the Tōhoku earthquake on 11 March 2011, we demonstrate capabilities of a new framework of methodologies for analyzing ionospheric perturbations. The framework consists of several new techniques: calculating velocity along a single direction to reduce error due to anisotropic propagation, producing normalized bidirectional band-pass spectra that preserve relative timing between various frequencies and allowing a more systematic determination of broadband pulses, and utilizing a wavelet-based technique that considers instantaneous wave phase changes, rather than best fit time differences, to evaluate wave characteristics (speed, direction, and wavelength) within spectral ranges of interest. Using these techniques together decreases subjectivity and reduces errors in attributing fluctuations to given sources. In validating this framework using the Tōhoku case, we consistently identify three kinds of waves: a broad-band pulse (speed: >2000 m/s, max range: >1400 km) arriving in the ionosphere 10–15 min after the quake, acoustic waves following the pulse (period: 3–5 min, speed: 700–1000 m/s, max range: <500 km), and gravity waves (period: 10–15 min, speed: 150–500 m/s, max range: >1400 km) propagating away from the epicenter, consistent with theory and demonstrated in previous studies. Lastly, this framework also can be applied to other impulsive events in the atmosphere that are more difficult to detect and attribute to sources.

58 GEOSCIENCES↗

Application of Spatial Data Modeling and Geographical Information Systems (GIS) for Identification of Potential Siting Options for Various Electrical Generation Sources

Oak Ridge National Laboratory (ORNL) initiated an internal National Electric Generation Siting Study, which is an ongoing multiphase study addressing several key questions related to our national electrical energy supply. This effort has led to the development of a tool, OR-SAGE (Oak Ridge Siting Analysis for power Generation Expansion), to support siting evaluations. The objective in developing OR-SAGE was to use industry-accepted approaches and/or develop appropriate criteria for screening sites and employ an array of Geographic Information Systems (GIS) data sources at ORNL to identify candidate areas for a power generation technology application. The initial phase of the study examined nuclear power generation. These early nuclear phase results were shared with staff from the Electric Power Research Institute (EPRI), which formed the genesis and support for an expansion of the work to several other power generation forms, including advanced coal with carbon capture and storage (CCS), solar, and compressed air energy storage (CAES). Wind generation was not included in this scope of work for EPRI. The OR-SAGE tool is essentially a dynamic visualization database. The results shown in this report represent a single static set of results using a specific set of input parameters. In this case, the GIS input parameters were optimized to support an economic study conducted by EPRI. A single set of individual results should not be construed as an ultimate energy solution, since US energy policy is very complex. However, the strength of the OR-SAGE tool is that numerous alternative scenarios can be quickly generated to provide additional insight into electrical generation or other GIS-based applications. The screening process divides the contiguous United States into 100 x 100 m (1-hectare) squares (cells), applying successive power generation-appropriate site selection and evaluation criteria (SSEC) to each cell. There are just under 700 million cells representing the contiguous United States. If a cell meets the requirements of each criterion, the cell is deemed a candidate area for siting a specific power generation form relative to a reference plant for that power type. Some SSEC parameters preclude siting a power plant because of an environmental, regulatory, or land-use constraint. Other SSEC assist in identifying less favorable areas, such as proximity to hazardous operations. All of the selected SSEC tend to recommend against sites. The focus of the ORNL electrical generation source siting study is on identifying candidate areas from which potential sites might be selected, stopping short of performing any detailed site evaluations or comparisons. This approach is designed to quickly screen for and characterize candidate areas. Critical assumptions supporting this work include the supply of cooling water to thermoelectric power generation; a methodology to provide an adequate siting footprint for typical power plant applications; a methodology to estimate thermoelectric plant capacity while accounting for available cooling water; and a methodology to account for future ({approx}2035) siting limitations as population increases and demands on freshwater sources change. OR-SAGE algorithms were built to account for these critical assumptions. Stream flow is the primary thermoelectric plant cooling source evaluated in this study. All cooling was assumed to be provided by a closed-cycle cooling (CCC) system requiring makeup water to account for evaporation and blowdown. Limited evaluations of shoreline cooling and the use of municipal processed water (gray) cooling were performed. Using a representative set of SSEC as input to the OR-SAGE tool and employing the accompanying critical assumptions, independent results for the various power generation sources studied were calculated.

01 COAL, LIGNITE, AND PEAT↗

Experimental and numerical studies of seismic fluid-structure interaction in a base-supported cylindrical vessel

Seismic design and qualification of advanced reactors will rely heavily on the use of verified and validated numerical models capable of capturing the interaction of the vessel, its contained fluid, and the internal equipment: fluid-structure interaction (FSI) analysis. Analytical solutions can be used for preliminary sizing and design of such vessels but their application is limited to simple geometries and boundary conditions, and small amplitude, translational (and rotational) inputs. To validate numerical models for seismic FSI analysis in finite element codes, a comprehensive set of experiments was performed on a liquid-filled cylindrical vessel, using a 6 degree-of-freedom earthquake simulator. Results in terms of sloshing frequency, damping ratio in sloshing modes, and hydrodynamic responses (wave height, hydrodynamic pressure, base shear, and base moment) for multi-directional earthquake simulator inputs are reported and compared with analytical solutions for liquid-filled vessels. The impact of seismic (base) isolation on hydrodynamic responses was studied using earthquake simulator inputs generated using a virtual isolation system. Data from the experiments are used to validate a numerical model of the fluid-filled vessel using the Arbitrary Lagrangian Eulerian (ALE) solver in the commercial finite element program LS-DYNA. Validation studies are presented for multi-directional seismic inputs, including rocking motions. Lagrangian modeling approaches using an elastic material formulation for the fluid are also investigated and their limitations and possible applications are identified. Here, the results are broadly applicable to the seismic response of base supported, liquid-filled vessels.

58 GEOSCIENCES↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The utility of diffusion-weighted imaging in improving the sensitivity of LI-RADS classification of small hepatic observations suspected of malignancy

Purpose: We investigated the added value of diffusion-weighted imaging (DWI)/apparent diffusion coefficient (ADC) in the categorization of small hepatic observation (≤ 20 mm) detected in patients with chronic liver disease in reference to LI-RADS (liver imaging reporting and data system) classification system. Methods: We prospectively evaluated 165 patients with chronic liver disease with small hepatic observations (≤ 20 mm) which were previously categorized as LI-RADS grade 3–5 on dynamic contrast-enhanced CT (DCE-CT). All patients were submitted to a functional MRI including DCE and DWI. Using LI-RADS v2017, two radiologists independently evaluated the observations and assigned a LI-RADS category to each observation using DCE-MRI alone and combined DCE-MRI and DWI/ADC. In the combined technique, the radiologists assigned a LI-RADS category based on a modified LI-RADS criteria in which restricted diffusion on DWI was considered a major feature of HCC. We evaluated the inter-reader agreement with Kappa statistics and compared the diagnostic performance of the LI-RADS with two imaging techniques by Fisher’s exact test using histopathology as the reference standard. Results: Combined technique in LI-RADS yielded better sensitivities (reader 1, 97% [65/67]; reader 2, 95.5% [64/67]) for HCC diagnosis than DCE-MRI alone (reader 1, 80.6% [54/67], p = 0.005; reader 2, 83.6% [56/67], p = 0.04). The specificities were insignificantly lower in combined technique (reader 1, 88.4% [107/121]; reader 2, 77.7% [94/121]) than in DCE-MRI alone (reader 1, 90.9% [110/121], p = 0.67; reader 2, 79.3% [96/121], p = 0.88). The inter-reader agreement of the LI-RADS scores between combined technique and DCE-MRI was good (κ = 0.765). Conclusion: The use of DWI/ADC as an additional major criterion, improved the sensitivity of LI-RADS in the diagnosis of HCC while keeping high specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of extracolonic findings and clinical outcomes in a screening and diagnostic CT colonography population

Purpose: To compare the distribution of extracolonic findings and clinical outcomes between screening and diagnostic CT colonography (CTC) populations. Methods: 388 consecutive patients (369 men, 19 women; mean ± SD age 67.8 ± 10 years) who underwent first-time CTC (4/2011–4/2017) at a Veteran’s Affairs Medical Center were divided into screening (asymptomatic) or diagnostic (symptomatic) cohorts based on CTC indication. CTC reporting and data system E-scores for extracolonic findings were retrospectively assigned based on prospective CTC radiologic reports. Multinomial logistic regression was used to examine the association between E-scores and CTC indication. Electronic medical records of all patients with E3 or E4 scores were reviewed (median follow-up 2.8 years) to determine clinical outcomes. Results: 68% (262/388) underwent screening and 32% (126/388) diagnostic CTC. 7.2% (28/388) had extracolonic findings considered potentially significant (E4), 4.4% (17/388) had indeterminate but likely unimportant findings (E3), and 88.4% (347/388) had normal or unimportant findings (E1 or E2). E-scores were not significantly different between screening and diagnostic CTC when adjusted for age, gender, and prior imaging (p = 0.44). 4.6% (12/262) of patients with E3/E4 findings in the screening cohort demonstrated clinically significant outcomes, compared with 4.0% (5/126) in the diagnostic cohort, including a total of three extracolonic malignancies (0.8%) and three abdominal aortic aneurysms (0.8%). 4.6% (18/388) underwent follow-up imaging studies to confirm a benign outcome after detection of a category E3/E4 finding. Conclusions: The distribution of extracolonic findings and clinical outcomes were not statistically significantly different between screening and diagnostic CTC populations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LI-RADS for CT diagnosis of hepatocellular carcinoma: performance of major and ancillary features

Purpose: To evaluate the diagnostic performance of Liver Imaging Reporting and Data System (LI-RADS) v2017 major features, the impact of ancillary features, and categories on contrast-enhanced computed tomography (CECT) for the diagnosis of hepatocellular carcinoma (HCC). Materials and methods: This retrospective study included 59 patients (104 observations including 72 HCCs) with clinical suspicion of HCC undergoing CECT between 2013 and 2016. Two radiologists independently assessed major and ancillary imaging features for each liver observation and assigned a LI-RADS category based on major features only and in combination with ancillary features. The composite reference standard included pathology or imaging. Per-lesion estimates of diagnostic performance of major features, ancillary features, and LI-RADS categories were assessed by generalized estimating equation models. Results: Major features (arterial phase hyperenhancement, washout, capsule, and threshold growth) respectively had a sensitivity of 86.1%, 81.6%, 20.7%, and 26.1% and specificity of 39.3%, 67.9%, 89.9%, and 85.0% for HCC. Ancillary features (ultrasound visibility as discrete nodule, subthreshold growth, and fat in mass more than adjacent liver) respectively had a sensitivity of 42.6%, 50.8%, and 15.1% and a specificity of 79.2%, 66.9%, and 96.4% for HCC. Ancillary features modified the final category in 4 of 104 observations. For HCC diagnosis, categories LR-3, LR-4, LR-5, and LR-TIV (tumor in vein) had a sensitivity of 5.3%, 29.0%, 53.7%, and 10.7%; and a specificity of 49.1%, 84.4%, 97.3%, and 96.4%, respectively. Conclusion: On CT, LR-5 category has near-perfect specificity for the diagnosis of HCC and ancillary features modifies the final category in few observations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The yield and patient factors associated with CT colonography C-RADS results in a non-screening patient population

Objectives: To determine the proportion of diagnostic computed tomography colonography (CTC) Reporting and Data System (C-RADS) categories in a non-screening population, and which patient factors are associated with a positive CTC (C2–4), a non-diagnostic CTC (C0), and potentially relevant extracolonic findings (ECF, E3–4). Methods: Diagnostic CTCs performed at a single academic center from 2017 to 2018 were retrospectively reviewed. For each examination, the indications, age, sex, admission status, and C-RADS categories were recorded. Multivariate logistic regression was performed of patient demographic factors and clinical indications, with adjusted odds ratios (OR) and 95% confidence intervals. Results: 1373 CTCs were included. The mean age was 66.4 ± 13 years (range 24–97). There were 782 women and 75 inpatients. The number of CTCs reported as C0–C4 were 194/1373 (14.1%), 970/1373 (70.6%), 77/1373 (5.6%), 86/1373 (6.3%), and 46/1373 (3.4%), respectively, and 134/1373 (9.8%), 960/1373 (69.9%), 173/1373 (12.6%), and 106/1373 (7.7%) CTCs were reported as E1–4, respectively. Factors that demonstrated the strongest associations were as follows: with C2–4, age groups 50–79 (OR 2.8, 95% confidence interval 1.4–6.1), 80–89 (6.2, 2.9–14.5) and ≥ 90 (7.6, 2.0–29.1), and inpatients (3.4, 1.8–6.4); with C0, age groups 50–79 (5.9, 2.2–24.4), 80–89 (9.8, 3.4–41.8), and ≥ 90 (22.5, 5.8–113.0), incomplete colonoscopy (3.2, 2.0–5.1) and melena or gastrointestinal bleeding (4.1, 1.8–9.4); and with E3–4, age groups 50–79 (1.6, 1.0–2.9), 80–89 (2.0, 1.1–3.9), and ≥ 90 (3.2, 1.2–8.8), and inpatients (2.3, 1.3–3.9). Conclusion: Older age is increasingly associated with a positive test, a non-diagnostic test and potentially relevant ECF. Inpatients are also associated with positive tests and E3–4 findings. Symptoms are not strongly associated with a positive CTC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Global teleconnections influencing large-scale drought in the United States using SVDI

Understanding recent large-scale drought patterns and the mechanisms producing extreme drought events is vital for future drought forecasts and understanding future drought risks. Increasingly, vapor pressure deficit (VPD) has been used as an important measure of evaporative demand and proxy for drought detection. In this study, VPD is used to calculate the new Standardized VPD Drought Index (SVDI) with NASA North American Land Data Assimilation System (NLDAS) data. Previous studies have shown that SVDI accurately identifies the timing and magnitude short-term droughts in the United States (U.S). In the present study, SVDI is now used to identify large-scale drought patterns between 1980 and 2021 and drought variability driven by selected global teleconnections originating in the Pacific and Atlantic Oceans. Spatial drought characteristics were extracted from SVDI using empirical orthogonal function (EOF) analysis. Then a k-means clustering algorithm was applied to both EOF principal components and primary teleconnections, including the El Nino-Southern Oscillation (ENSO) and Pacific Decadal Oscillation (PDO) to identify drought events driven by the Pacific Ocean. Results show that the SVDI is useful in evaluating large-scale drought variability in the U.S. related to global teleconnections, and that mechanisms influencing summer drought patterns in the Western and Southwestern U.S. are driven by a tropical-extratropical interactions originating in the equatorial Pacific Ocean related to ENSO dynamics with interdecadal variability modulated by PDO. The large-scale droughts in the Central and Southern U.S., like those in 2011 and 2012, on the other hand, are driven by the North Pacific Ocean warm pool during a strong negative PDO, which subsequently influenced variability in the Bermuda-Azores High in the Atlantic Ocean. In summer 2011, the Bermuda-Azores High weakened, reducing the onshore winds and moisture transport along the eastern Gulf of Mexico and contributing to ongoing drought in the region. The Northern Pacific and Atlantic Ocean sea surface temperatures (SSTs) have increased between 1980 and 2021. In conclusion, as SSTs continue to rise in the Northern Pacific Ocean, one consequence of the coupled North Pacific warm pool and atmospheric dynamics, is to increase summer drought variability over a large region in the southern and midwestern U.S. under global warming.

54 ENVIRONMENTAL SCIENCES↗

Understanding Clinical Mammographic Breast Density Assessment: a Deep Learning Perspective

Mammographic breast density has been established as an independent risk marker for developing breast cancer. Breast density assessment is a routine clinical need in breast cancer screening and current standard is using the Breast Imaging and Reporting Data System (BI-RADS) criteria including four qualitative categories (i.e., fatty, scattered density, heterogeneously dense, or extremely dense). In each mammogram examination, a breast is typically imaged with two different views, i.e., the mediolateral oblique (MLO) view and cranial caudal (CC) view. The BI-RADS-based breast density assessment is a qualitative process made by visual observation of both the MLO and CC views by radiologists, where there is a notable inter- and intra-reader variability. In order to maintain consistency and accuracy in BI-RADS-based breast density assessment, gaining understanding on radiologists’ reading behaviors will be educational. In this study, we proposed to leverage the newly emerged deep learning approach to investigate how the MLO and CC view images of a mammogram examination may have been clinically used by radiologists in coming up with a BI-RADS density category. We implemented a convolutional neural network (CNN)-based deep learning model, aimed at distinguishing the breast density categories using a large (15,415 images) set of real-world clinical mammogram images. Our results showed that the classification of density categories (in terms of area under the receiver operating characteristic curve) using MLO view images is significantly higher than that using the CC view. This indicates that most likely it is the MLO view that the radiologists have predominately used to determine the breast density BI-RADS categories. Our study holds a potential to further interpret radiologists’ reading characteristics, enhance personalized clinical training to radiologists, and ultimately reduce reader variations in breast density assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling of Gas Dynamic Processes in the Interelectrode Gap of a Multielement Thermionic Electricity Generating Channel by Solving the Kinetic Equation

This work is devoted to the application of a numerical method of solving Boltzmann’s equation for modeling the behavior of radionuclides (Kr, Xe, Rb, Sr, Cs, Ba) in the cavity of the interelectrode gap of a multielement electricity generating channel. Modeling methods were developed and software system implemented in the course of this work. Calculations were performed for two structural arrangements: with uni- and bilateral extraction of radionuclides into the vacuum-cesium system. Data on the pressure and flow distributions were obtained. The krypton and xenon pressure near the collector as functions of their flow and the cesium gas pressure at the gap exits were determined computationally.

07 ISOTOPE AND RADIATION SOURCES↗

Sodium benzoate induced developmental defects, oxidative stress and anxiety-like behaviour in zebrafish larva

Highlights: • Sodium benzoate induced developmental defects in zebrafish. • Sodium benzoate induced oxidative stress in zebrafish by upregulation of glutathione reductase (gsr). • Sodium benzoate induced anxiety-like behaviour in zebrafish. Sodium benzoate (SB) is a common food preservative. Its FDA described safety limit is 1000 ppm. Lately, increased use of SB has prompted investigations regarding its effects on biological systems. Data regarding toxicity of SB is divergent and controversial with studies reporting both harmful and beneficial effects. Therefore, we did a systematic dose dependent toxicity study of SB using zebrafish vertebrate animal model. We also investigated oxidative stress and anxiety-like behaviour in zebrafish larva treated with SB. Our results indicate that SB induced developmental (delayed hatching), morphological (pericardial edema, yolk sac edema and tail bending), biochemical (oxidative stress) and behavioural (anxiety-like behaviour) abnormalities in developing zebrafish larva. LC{sub 50} of SB induced toxicity was approximately 400 ppm after 48 h of SB exposure. Our study strongly supports its harmful effects on vertebrates at increasing doses. Thus, we suggest caution in the excessive use of this preservative in processed and convenience foods.

60 APPLIED LIFE SCIENCES↗

Integrating science for water security governance

Hydrological extremes are intensifying globally, increasing the complexity of decisions required to ensure water security. Advances in hydrological science, modeling, and data systems have expanded the technical frontier of water research, yet uptake of scientific insights in policy and management decisions remains limited. This persistent science–policy gap is not primarily a failure of knowledge generation or robustness, but an institutional challenge shaped by how scientific and governance systems are organized, coordinated, and connected to support the effective use of scientific knowledge. These challenges are particularly pronounced in multi-level and transboundary water governance, where decisions span jurisdictions and require coordination across institutional and political boundaries. We synthesize research at the science–policy interface and evidence from water security initiatives to show how institutional arrangements, scientific tool development, and research practices enable or constrain the sustained use of scientific knowledge in water-security governance processes. Building on these insights, we develop ‘shared decision infrastructure’ as a framing to describe how scientific knowledge is embedded within the institutional, relational, and procedural arrangements that connect science to decision-making processes over time. We translate this framing into a practical intervention roadmap centered on institutional design, tool translation, sustained co-production, and outcome-oriented evaluation to support the integration of science into ongoing governance processes. By positioning science as shared decision infrastructure, the roadmap clarifies how researchers can design scientific efforts that support more coordinated, accountable, and adaptive water security decisions amid deepening uncertainty.

M whitney, Kristen [NASA Goddard Space Flight Cent↗

Distance to Radiation Facility and Treatment Choice in Early-Stage Breast Cancer

Purpose: Breast-conserving therapy (BCT) is a recommended alternative to mastectomy (MT) for early-stage breast cancer. Limited access to radiation therapy (RT) may result in higher rates of MT. We assessed the association between distance to the nearest RT facility and the use of MT, in a modern cohort of women. Methods and Materials: Women with stage 0-II breast cancer eligible for BCT diagnosed from 2004 to 2010 were identified from the Florida Cancer Data System (FCDS). Distances from patient census tracts to the nearest RT facility census tract were calculated. Multivariate logistic regression was used to identify explanatory variables that influenced MT use. Results: Of the 27,489 eligible women, 32.1% (n=8841) underwent MT, and 67.8% (n=18,648) underwent BCS. Thirty-two percent of patients lived in a census tract that was >5 miles from an RT facility. MT use increased with increasing distance to RT facility (31.1% at ≤5 miles, 33.8% at >5 to <15 miles, 34.9% at 15 to <40 miles, and 51% at ≥40 miles, P<.001). The likelihood was that MT was independently associated with increasing distance to RT facility on multivariate analysis (P<.001). Compared to patients living <5 miles away from an RT facility, patients living 15 to <40 miles away were 1.2 times more likely to be treated with MT (odds ratio [OR]: 1.19, 95% confidence interval [CI]: 1.05-1.35, P<.01), and those living ≥40 miles away were more than twice as likely to be treated with MT (OR: 2.17, 95% CI: 1.48-3.17, P<.001). However, in patients younger than 50 years (n=5179), MT use was not associated with distance to RT facility (P=.235). Conclusions: MT use in a modern cohort of women is independently associated with distance to RT facility. However, for young patients, distance to RT is not a significant explanatory variable for MT use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗