At least 811 records · Page 45

Control algorithms for dynamic attenuators

Purpose: The authors describe algorithms to control dynamic attenuators in CT and compare their performance using simulated scans. Dynamic attenuators are prepatient beam shaping filters that modulate the distribution of x-ray fluence incident on the patient on a view-by-view basis. These attenuators can reduce dose while improving key image quality metrics such as peak or mean variance. In each view, the attenuator presents several degrees of freedom which may be individually adjusted. The total number of degrees of freedom across all views is very large, making many optimization techniques impractical. The authors develop a theory for optimally controlling these attenuators. Special attention is paid to a theoretically perfect attenuator which controls the fluence for each ray individually, but the authors also investigate and compare three other, practical attenuator designs which have been previously proposed: the piecewise-linear attenuator, the translating attenuator, and the double wedge attenuator. Methods: The authors pose and solve the optimization problems of minimizing the mean and peak variance subject to a fixed dose limit. For a perfect attenuator and mean variance minimization, this problem can be solved in simple, closed form. For other attenuator designs, the problem can be decomposed into separate problems for each view to greatly reduce the computational complexity. Peak variance minimization can be approximately solved using iterated, weighted mean variance (WMV) minimization. Also, the authors develop heuristics for the perfect and piecewise-linear attenuators which do not requirea priori knowledge of the patient anatomy. The authors compare these control algorithms on different types of dynamic attenuators using simulated raw data from forward projected DICOM files of a thorax and an abdomen. Results: The translating and double wedge attenuators reduce dose by an average of 30% relative to current techniques (bowtie filter with tube current modulation) without increasing peak variance. The 15-element piecewise-linear dynamic attenuator reduces dose by an average of 42%, and the perfect attenuator reduces dose by an average of 50%. Improvements in peak variance are several times larger than improvements in mean variance. Heuristic control eliminates the need for a prescan. For the piecewise-linear attenuator, the cost of heuristic control is an increase in dose of 9%. The proposed iterated WMV minimization produces results that are within a few percent of the true solution. Conclusions: Dynamic attenuators show potential for significant dose reduction. A wide class of dynamic attenuators can be accurately controlled using the described methods.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prognosis of Wind Turbine Gearbox Bearing Failures Using SCADA and Modeled Data

Predictive maintenance and condition monitoring systems for wind turbines have seen increased adoption to minimize downtime, reducing operation and maintenance costs. On today’s wind power plants, the integrated supervisory control and data acquisition (SCADA) system provides low- frequency operational data that can be leveraged to quantify a wind turbine’s health. The aim of this study is to utilize machine-learning techniques to predict axial cracking failures in wind turbine gearbox bearings up to 1 month ahead of time. The failures are assumed to have occurred when the investigated bearing was replaced. While current SCADA systems show the overall condition of a wind turbine, often they do not allow for the investigation of specific gearbox bearings’ health. To enrich bearing fault signatures, additional data are computed through physics-based models using gearbox design information. Based on SCADA data, modeled data, and bearing failure log data from an actual wind plant, the performances of different machine-learning models on unseen data are then evaluated using industry-standard metrics such as precision, recall, and F1 score. Results show the overall system performance enhancement in predicting bearing failure when modeled data are included with SCADA data. The reduction in terms of false alarms is about 50%, and improvement in terms of precision and F1 score is about 33% and 12% respectively, based on the best modeling case in this study.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

γ-Ray spectroscopy using a binned likelihood approach

The measurement of a reaction cross section from a pulse height spectrum is a ubiquitous problem in experimental nuclear physics. In γ-ray spectroscopy, this is accomplished frequently by measuring the intensity of full-energy primary transition peaks and correcting the intensities for experimental artifacts, such as detection efficiencies and angular correlations. Implicit in this procedure is the assumption that full-energy peaks do not overlap with any secondary peaks, escape peaks, or environmental back- grounds. However, for complex γ-ray cascades, this is often not the case. Furthermore, this technique is difficult to adapt for coincidence spectroscopy, where intensities depend not only on the detection efficiency, but also the detailed decay scheme. We present a method that incorporates the intensities of the entire spectrum (e.g., primary and secondary transition peaks, escape peaks, Compton continua, etc.) into a statistical model, where the transition intensities and branching ratios can be determined using Bayesian statistical inference. This new method provides an elegant solution to the difficulties associated with analyzing coincidence spectra. Finally, we describe it in detail and examine its efficacy in the analysis of 18 O(p,γ) 19 F and 25 Mg(p,γ) 26 Al resonance data. For the 18 O(p,γ) 19 F reaction, the measured branching ratios improve upon the literature values, with a factor of 3 reduction in the uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronics qualification of the Jules Horowitz reactor fuel by interpretation of the VALMONT experimental program - Transposition of the uncertainties on the reactivity of JHR with JEF2.2 and JEFF3.1.1

The new European material testing Jules Horowitz Reactor (JHR), currently under construction in Cadarache center (CEA France), will use LEU (20% enrichment in {sup 235}U) fuels (U{sub 3}Si{sub 2} for the start up and UMoAl in the future) which are quite different from the industrial oxide fuel, for which an extensive neutronics qualification database has been established. The HORUS3D/N neutronics calculation scheme, used for the design and safety studies of the JHR, is being developed within the framework of a rigorous verification-validation-qualification methodology. In this framework, the experimental VALMONT (Validation of Aluminium Molybdenum uranium fuel for Neutronics) program has been performed in the MINERVE facility of CEA Cadarache (France), in order to qualify the capability of HORUS3D/N to accurately calculate the reactivity of the JHR reactor. The MINERVE facility using the oscillation technique provides accurate measurements of reactivity effect of samples. The VALMONT program includes oscillations of samples of UAl{sub x}/Al and UMo/Al with enrichments ranging from 0.2% to 20% and Uranium densities from 2.2 to 8 g/cm{sup 3}. The geometry of the samples and the pitch of the experimental lattice ensure maximum representativeness with the neutron spectrum expected for JHR. By comparing the effect of the sample with the one of a known fuel specimen, the reactivity effect can be measured in absolute terms and be compared to computational results. Special attention was paid to the rigorous determination and reduction of the experimental uncertainties. The calculational analysis of the VALMONT results was performed with the French deterministic code APOLLO2. A comparison of the impact of the different calculation methods, data libraries and energy meshes that were tested is presented. The interpretation of the VALMONT experimental program allowed the qualification of JHR fuel UMoAl8 (with an enrichment of 19.75% {sup 235}U) by the Minerve-dedicated interpretation tool: PIMS. The effect of energy meshes and evaluations put forward the JEFF3.1.1/SHEM scheme that leads to a better calculation of the reactivity effect of VALMONT samples. Then, in order to quantify the impact of the uncertainties linked to the basic nuclear data, their propagation from the cross section measurement to the final computational result was analysed in a rigorous way by using a nuclear data re-estimation method based on Gauss-Newton iterations. This study concludes that the prior uncertainties due to nuclear data (uranium, aluminium, beryllium and water) on the reactivity of the Begin Of Cycle (BOC) for the JHR core reach 1217 pcm at 2{sigma}. Now, the uppermost uncertainty on the JHR reactivity is due to aluminium. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Harnessing microbial subsurface metal reduction activities to synthesise nanoscale cobalt ferrite with enhanced magnetic properties

Nanoscale ferrimagnetic particles have a diverse range of uses from directed cancer therapy and drug delivery systems to magnetic recording media and transducers. Such applications require the production of monodisperse nanoparticles with well-controlled size, composition, and magnetic properties. To fabricate these materials purely using synthetic methods is costly in both environmental and economical terms. However, metal-reducing microorganisms offer an untapped resource to produce these materials. Here, the Fe(III)-reducing bacterium Geobacter sulfurreducens is used to synthesize magnetic iron oxide nanoparticles. A combination of electron microscopy, soft X-ray spectroscopy, and magnetometry techniques was employed to show that this method of biosynthesis results in high yields of crystalline nanoparticles with a narrow size distribution and magnetic properties equal to the best chemically synthesized materials. In particular, it is demonstrated here that cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles with low temperature coercivity approaching 8 kOe and an effective anisotropy constant of {approx} 10{sup 6} erg cm{sup -3} can be manufactured through this biotechnological route. The dramatic enhancement in the magnetic properties of the nanoparticles by the introduction of high quantities of Co into the spinel structure represents a significant advance over previous biomineralization studies in this area using magnetotactic bacteria. The successful production of nanoparticulate ferrites achieved in this study at high yields could open up the way for the scaled-up industrial manufacture of nanoparticles using environmentally benign methodologies. Production of ferromagnetic nanoparticles for pioneering cancer therapy, drug delivery, chemical sensors, catalytic activity, photoconductive materials, as well as more traditional uses in data storage embodies a large area of inorganic synthesis research. In particular, the addition of transition metals other than Fe into the structure of magnetite (Fe{sub 3}O{sub 4}) has been shown to greatly enhance the magnetic properties of the particles, tailoring them to different commercial uses. However, synthesis of magnetic nanoparticles is often carried out at high temperatures with toxic solvents resulting in high environmental and energy costs. Additionally, these ferrite nanoparticles are not intrinsically biocompatible, and to make them suitable for insertion into the human body is a rather intricate task. A relatively unexplored resource for magnetic nanomaterial production is subsurface Fe(III)-reducing bacteria, as these microorganisms are capable of producing large quantities of nanoscale magnetite (Fe{sub 3}O{sub 4}) at ambient temperatures. Metal-reducing bacteria live in environments deficient in oxygen and conserve energy for growth through the oxidation of hydrogen or organic electron donors, coupled to the reduction of oxidized metals such as Fe(III)-bearing minerals. This can result in the formation of magnetite via the extracellular reduction of amorphous Fe(III)-oxyhydroxides causing the release of soluble Fe(II) and resulting in complete recrystallization of the amorphous mineral into a new phase. Some previous studies have reported altering the composition of biogenic magnetite produced by Fe(III)-reducing bacteria for industrial and environmental applications. However, research into the commercial exploitation of bacteria to form magnetic minerals has focused primarily on magnetotactic bacteria which form magnetosomal magnetite internally using very different pathways to those bacteria forming magnetite outside the cell. Magnetotactic bacteria live at the sediment-water interface and use internal nanomagnets to guide them to their preferred environmental niche using the Earth's magnetic field. Since magnetotactic bacteria generally grow optimally under carefully controlled microaerobic conditions, the culturing processes for these organisms are challenging and result in low yields of nanomagnetite. Despite these limitations, magnetotactic bacteria have been shown to incorporate {approx}1% Co into the magnetite structure in vivo, and CoFe{sub 2}O{sub 4} was synthesized in vitro, altering the magnetic properties of the material formed. Although these previous studies are an important first step, in order to obtain the degree of control over the magnetic properties required by potential applications, Co must be incorporated into the spinel structure together with high nanoparticle yields. It is not clear at present how this could be achieved using the highly regulated intracellular magnetosome systems. We present an alternative and efficient method to produce large quantities of highly crystalline magnetite and cobalt ferrite nanoparticles using the Fe(III)-reducing bacterium, Geobacter sulfurreducens, at ambient temperatures through the extracellular dissimilatory reduction of Fe(III)-oxyhydroxides without and with addition of cobalt.

58 GEOSCIENCES↗

Volumetric Modulated Arc Therapy for Delivery of Prostate Radiotherapy: Comparison With Intensity-Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy

Purpose: Volumetric modulated arc therapy (VMAT) is a novel form of intensity-modulated radiotherapy (IMRT) optimization that allows the radiation dose to be delivered in a single gantry rotation of up to 360{sup o}, using either a constant dose rate (cdr-VMAT) or variable dose rate (vdr-VMAT) during rotation. The goal of this study was to compare VMAT prostate RT plans with three-dimensional conformal RT (3D-CRT) and IMRT plans. Patients and Methods: The 3D-CRT, five-field IMRT, cdr-VMAT, and vdr-VMAT RT plans were created for 10 computed tomography data sets from patients undergoing RT for prostate cancer. The parameters evaluated included the doses to organs at risk, equivalent uniform doses, dose homogeneity and conformality, and monitor units required for delivery of a 2-Gy fraction. Results: The IMRT and both VMAT techniques resulted in lower doses to normal critical structures than 3D-CRT plans for nearly all dosimetric endpoints analyzed. The lowest doses to organs at risk and most favorable equivalent uniform doses were achieved with vdr-VMAT, which was significantly better than IMRT for the rectal and femoral head dosimetric endpoints (p < 0.05) and significantly better than cdr-VMAT for most bladder and rectal endpoints (p < 0.05). The vdr-VMAT and cdr-VMAT plans required fewer monitor units than did the IMRT plans (relative reduction of 42% and 38%, respectively; p = 0.005) but more than for the 3D-CRT plans (p = 0.005). Conclusion: The IMRT and VMAT techniques achieved highly conformal treatment plans. The vdr-VMAT technique resulted in more favorable dose distributions than the IMRT or cdr-VMAT techniques, and reduced the monitor units required compared with IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personalized whole-brain neural mass models reveal combined Aβ and tau hyperexcitable influences in Alzheimer's disease.

Neuronal dysfunction and cognitive deterioration in Alzheimer's disease (AD) are likely caused by multiple pathophysiological factors. However, mechanistic evidence in humans remains scarce, requiring improved non-invasive techniques and integrative models. We introduce personalized AD computational models built on whole-brain Wilson-Cowan oscillators and incorporating resting-state functional MRI, amyloid-β (Aβ) and tau-PET from 132 individuals in the AD spectrum to evaluate the direct impact of toxic protein deposition on neuronal activity. This subject-specific approach uncovers key patho-mechanistic interactions, including synergistic Aβ and tau effects on cognitive impairment and neuronal excitability increases with disease progression. The data-derived neuronal excitability values strongly predict clinically relevant AD plasma biomarker concentrations (p-tau217, p-tau231, p-tau181, GFAP) and grey matter atrophy obtained through voxel-based morphometry. Furthermore, reconstructed EEG proxy quantities show the hallmark AD electrophysiological alterations (theta band activity enhancement and alpha reductions) which occur with Aβ-positivity and after limbic tau involvement. Microglial activation influences on neuronal activity are less definitive, potentially due to neuroimaging limitations in mapping neuroprotective vs detrimental activation phenotypes. Mechanistic brain activity models can further clarify intricate neurodegenerative processes and accelerate preventive/treatment interventions.

60 APPLIED LIFE SCIENCES↗

Adapting In Situ Accelerators for Sparsity With Granular Matrix Reordering

Neural network (NN) inference is an essential part of modern systems and is found at the heart of numerous applications ranging from image recognition to natural language processing. In situ NN accelerators can efficiently perform NN inference using resistive crossbars, which makes them a promising solution to the data movement challenges faced by conventional architectures. Although such accelerators demonstrate significant potential for dense NNs, they often do not benefit from sparse NNs, which contain relatively few non-zero weights. Processing sparse NNs on in situ accelerators results in wasted energy to charge the entire crossbar where most elements are zeros. To address this limitation, this paper proposes Granular Matrix Reordering (GMR): a preprocessing technique that enables an energy-efficient computation of sparse NNs on in situ accelerators. GMR reorders the rows and columns of sparse weight matrices to maximize the crossbars' utilization and minimize the total number of crossbars needed to be charged. The reordering process does not rely on sparsity patterns and incurs no accuracy loss. Finally, GMR achieves an average of 28% and up to 34% reduction in energy consumption over seven pruned NNs across four different pruning methods and network architectures.

97 MATHEMATICS AND COMPUTING↗

CORE-BFS: Communication-Optimized REctangular-partitioned BFS Achieving 160.845 TeraTEPS on Frontier Supercomputer

Distributed Breadth-First Search (BFS) is fundamental to many large-scale graph applications, but its performance on parallel systems is often limited by high communication overhead. This paper presents CORE-BFS, an extremely scalable GPU-based BFS implementation that introduces a unique rectangular 2D partitioning-based design for Frontier supercomputer. To further improve performance, we propose four key optimizations: (1) Rectangular 2D-partition specific data formats that use two compressed row and one compressed column status array bitmaps combined with a Double Compressed Sparse Row (DCSR) format per partition, reducing memory footprint and inter-rank traffic; (2) Adaptive frontier & communication strategy that unifies top-down and bottom-up traversal on the rectangular layout, uses lazy synchronization in top-down levels, and switches variants based on frontier size to minimize communication overhead; (3) Frontier-split degree-aware update that maps frontier vertices to thread-centric, wavefront-centric, and block-centric kernels based on their degree to improve GPU utilization and memory coalescing; (4) Row-reduction pipeline that overlaps bottom-up adjacency list processing with row-wise bitmap reduction to hide inter-rank latency. Together, these techniques increase parallelism while reducing memory and communication overhead. On the Graph500 benchmark, CORE - BFS scales up to 9,248 Frontier nodes with scale-42 graphs and reaches 160.845 TTEPS, delivering a 5.42 × speedup over our previous Frontier implementation.

Yang, Haoshen [Rutgers University]↗

Extracting Operating Modes from Building Electrical Load Data: Preprint

Empirical techniques for characterizing electrical energy use now play a key role in reducing electricity consumption, particularly miscellaneous electrical loads, in buildings. Identifying device operating modes (mode extraction) creates a better understanding of both device and system behaviors. Using clustering to extract operating modes from electrical load data can provide valuable insightsinto device behavior and identify opportunities for energy savings. We present a fast and effective heuristic clustering method to identify and extract operating modes in electrical load data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracking the topology of neural manifolds across populations

Neural manifolds summarize the intrinsic structure of the information encoded by a population of neurons. Advances in experimental techniques have made simultaneous recordings from multiple brain regions increasingly commonplace, raising the possibility of studying how these manifolds relate across populations. However, when the manifolds are nonlinear and possibly code for multiple unknown variables, it is challenging to extract robust and falsifiable information about their relationships. We introduce a framework, called the method of analogous cycles, for matching topological features of neural manifolds using only observed dissimilarity matrices within and between neural populations. We demonstrate via analysis of simulations and in vivo experimental data that this method can be used to correctly identify multiple shared circular coordinate systems across both stimuli and inferred neural manifolds. Conversely, the method rejects matching features that are not intrinsic to one of the systems. Further, as this method is deterministic and does not rely on dimensionality reduction or optimization methods, it is amenable to direct mathematical investigation and interpretation in terms of the underlying neural activity. We thus propose the method of analogous cycles as a suitable foundation for a theory of cross-population analysis via neural manifolds.

97 MATHEMATICS AND COMPUTING↗

MODELING MULTI-WAVELENGTH STELLAR ASTROMETRY. II. DETERMINING ABSOLUTE INCLINATIONS, GRAVITY-DARKENING COEFFICIENTS, AND SPOT PARAMETERS OF SINGLE STARS WITH SIM LITE

We present a novel technique to determine the absolute inclination of single stars using multi-wavelength submilliarcsecond astrometry. The technique exploits the effect of gravity darkening, which causes a wavelength-dependent astrometric displacement parallel to a star's projected rotation axis. We find that this effect is clearly detectable using SIM Lite for various giant stars and rapid rotators, and present detailed models for multiple systems using the REFLUX code. We also explore the multi-wavelength astrometric reflex motion induced by spots on single stars. We find that it should be possible to determine spot size, relative temperature, and some positional information for both giant and nearby main-sequence stars utilizing multi-wavelength SIM Lite data. These data will be extremely useful in stellar and exoplanet astrophysics, as well as supporting the primary SIM Lite mission through proper multi-wavelength calibration of the giant star astrometric reference frame, and reduction of noise introduced by starspots when searching for extrasolar planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep Hierarchical Super Resolution for Scientific Data

We present a novel technique for hierarchical super resolution (SR) with neural networks (NNs), which upscales volumetric data represented with an octree data structure to a high-resolution uniform gridwith minimal seam artifacts on octree node boundaries. Our method uses existing state-of-the-art SR models and adds flexibility to upscale input data with varying levels of detail across the domain, instead of only uniform grid data that are supported in previous approaches.The key is to use a hierarchy of SR NNs, each trained to perform 2x SR between two levels of detail, with a hierarchical SR algorithm that minimizes seam artifacts by starting from the coarsest level of detail and working up.We show that our hierarchical approach outperforms baseline interpolation and hierarchical upscaling methods, and demonstrate the usefulness of our proposed approach across three use cases including data reduction using hierarchical downsampling+SR instead of uniform downsampling+SR, computation savings for hierarchical finite-time Lyapunov exponent field calculation, and super-resolving low-resolution simulation results for a high-resolution approximation visualization.

97 MATHEMATICS AND COMPUTING↗

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A measurement of stellar surface gravity hidden in radial velocity differences of comoving stars

The gravitational redshift induced by stellar surface gravity is notoriously difficult to measure for non-degenerate stars, since its amplitude is small in comparison with the typical Doppler shift induced by stellar radial velocity. In this study, we make use of the large observational data set of the Gaia mission to achieve a significant reduction of noise caused by these random stellar motions. By measuring the differences in velocities between the components of the pairs of comoving stars and wide binaries, in this work we are able to statistically measure the combined effects of gravitational redshift and convective blueshifting of spectral lines, and nullify the effect of the peculiar motions of the stars. For the subset of stars considered in this study, we find a positive correlation between the observed differences in Gaia radial velocities and the differences in surface gravity and convective blueshift inferred from effective temperature and luminosity measurements. The results rule out a null signal at the 5σ level for our full data set. Additionally, we study the subdominant effects of binary motion, and possible systematic errors in radial velocity measurements within Gaia. Results from the technique presented in this study are expected to improve significantly with data from the next Gaia data release. Such improvements could be used to constrain the mass–luminosity relation and stellar models that predict the magnitude of convective blueshift.

(stars:) binaries: general↗

( d , n ) proton-transfer reactions on Be 9 , B 11 , C 13 , N 14 , 15 , and F 19 and spectroscopic factors at E d = 16 MeV

The (d,n) reaction has been studied with targets of 9 Be, 11 B, 13 C, 14,15 N, and 19F at E d = 16MeV using a deuterated liquid-scintillator array. Advanced spectral unfolding techniques with accurately measured scintillator response functions were employed to extract neutron energy spectra without the need for long-path neutron time-of-flight. An analysis of the proton-transfer data at forward angles to the ground states of the final nuclei, using finite-range distorted-wave Born approximation analysis with common bound-state, global, and local optical-model parameter sets, yields a set of self-consistent spectroscopic factors. These are compared with the results of several previous time-of-flight measurements, most done many years ago for individual nuclei at lower energy and often analyzed using zero-range transfer codes. In contrast to some of the earlier published data, our data generally compare well with simple shell-model predictions, with little evidence for uniform quenching (reduction from shell-model values) that has previously been reported from analysis of nucleon knock-out reactions. Data for low-lying excited states in 14 N from 13 C(d,n) also is analyzed and spectroscopic information relevant to nuclear astrophysics obtained. Here, a preliminary study of the radioactive ion beam induced reaction 7 Be(d,n), E( 7 Be) = 30MeV was carried out and indicates further improvements are needed for such measurements, which require detection of neutrons with E n < 2MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗