Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Reciprocating Feed System Development Status

The reciprocating feed system (RFS) is an alternative means of providing high pressure propellant flow at low cost and system mass, with high fail-operational reliability. The RFS functions by storing the liquid propellants in large, low-pressure tanks and then expelling each propellant through two or three small, high-pressure tanks. Each RFS tank is sequentially filled, pressurized, expelled, vented, and refilled so as to provide a constant, or variable, mass flow rate to the engine. This type of system is much lighter than a conventional pressure fed system in part due to the greatly reduced amount of inert tank weight. The delivered payload for an RFS is superior to that of conventional pressure fed systems for conditions of high total impulse and it is competitive with turbopump systems, up to approximately 2000 psi. An advanced version of the RFS uses autogenous pressurization and thrust augmentation to achieve higher performance. In this version, the pressurization gases are combusted in a small engine, thus making the pressurization system, in effect, part of the propulsion system. The RFS appears to be much less expensive than a turbopump system, due to reduced research and development cost and hardware cost, since it is basically composed of small high- pressure tanks, a pressurization system, and control valves. A major benefit is the high reliability fail-operational mode; in the event of a failure in one of the three tank-systems, it can operate on the two remaining tanks. Other benefits include variable pressure and flow rates, ease of engine restart in micro-gravity, and enhanced propellant acquisition and control under adverse acceleration conditions. We present a system mass analysis tool that accepts user inputs for various design and mission parameters and calculates such output values payload and vehicle weights for the conventional pressure fed system, the RFS, the Autogenous Pressurization Thrust Augmentation (APTA) RFS, and turbopump systems. Using this tool, a preliminary design of a representative crew exploration vehicle (CEV) has been considered. The design parameters selected for a representative system were modeled after the orbital maneuvering system (OMS) on the Shuttle Orbiter, with an increase of roughly a factor of ten in the delta- V capability and a greater thrust (30,000 lbs, vs. 12,000 lbs). Both storable and cryogenic propellants were considered. Results show that a RFS is a low mass alternative to conventional pressure fed systems, with a substantial increase in payload capability and that it is weight-competitive with turbopump systems at low engine pressure (a few hundred psi); at high engine pressures, the APTA RFS appears to offer the highest payload. We also present the status of the RFS test bed fabrication, assembly, and checkout. This test bed is designed to provide flow rates appropriate for engines in the roughly 10,000 to 30,000 lb thrust range.

Trewek, Mary↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

High resolution x-ray Thomson scattering measurements from cryogenic hydrogen jets using the linac coherent light source

We present the first spectrally resolved measurements of x-rays scattered from cryogenic hydrogen jets in the single photon counting limit. The 120 Hz capabilities of the LCLS, together with a novel hydrogen jet design [J. B. Kim et al., Rev. Sci. Instrum. (these proceedings)], allow for the ability to record a near background free spectrum. Such high-dynamic-range x-ray scattering measurements enable a platform to study ultra-fast, laser-driven, heating dynamics of hydrogen plasmas. This measurement has been achieved using two highly annealed pyrolytic graphite crystal spectrometers to spectrally resolve 5.5 keV x-rays elastically and inelastically scattered from cryogenic hydrogen and focused on Cornell-SLAC pixel array detectors [S. Herrmann et al., Nucl. Instrum. Methods Phys. Res., Sect. A 718, 550 (2013)].

43 PARTICLE ACCELERATORS↗

A NEW CONCEPT FOR HIGH POWER RF COUPLING BETWEEN WAVEGUIDES AND RESONANT RF CAVITIES

Microwave engineering of high average-power (hundreds of kilowatts) devices often involves a transition from a waveguide to a device, typically a resonant cavity. This is a basic operation, which finds use in various application areas of significance to science and industry. At relatively low frequencies, L-band and below, it is convenient, sometimes essential, to couple the power between the waveguide and the cavity through a coaxial antenna, forming a power coupler. Power flow to the cavity in the fundamental mode leads to a Fundamental Power Coupler (FPC). High-order mode power generated in the cavity by a particle beam leads to a high-order mode power damper. Coupling a cryogenic device, such as a superconducting cavity to a room temperature power source (or damp) leads to additional constraints and challenges. We propose a new approach to this problem, wherein the coax line element is operated in a TE11 mode rather than the conventional TEM mode. We will show that this method leads to a significant increase in the power handling capability of the coupler as well as a few other advantages. As a result, we describe the mode converter from the waveguide to the TE11 coax line, outline the characteristics and performance limits of the coupler and provide a detailed worked out example in the challenging area of coupling to a superconducting accelerator cavity.

43 PARTICLE ACCELERATORS↗

Formation of niobium hydride precipitates in superconducting qubits

We report evidence for the formation of niobium hydride phase within niobium films on silicon substrates in superconducting qubits fabricated at Rigetti Computing. For this study, we combined complementary techniques—including room-temperature and cryogenic atomic force microscopy (AFM), synchrotron x-ray diffraction, and time-of-flight secondary ion mass spectroscopy (ToF-SIMS)—to directly reveal the existence of niobium hydride precipitates on the surface of superconducting qubits. Upon cryogenic cooling, we observed variation in the size and morphology of the hydrides, ranging from small (∼5 nm) irregular shapes to large (∼10–100 nm) domains within the Nb grains, which were fully converted to niobium hydrides. Since niobium hydrides are nonsuperconducting and can easily change in size and location upon different cooldowns to cryogenic temperature, our finding highlights a previously unknown source of decoherence in superconducting qubits. This contributes to quasiparticle losses, offering a potential explanation for changes in qubit performance upon cooldowns. Finally, by leveraging the RF performance of a 3D bulk Nb resonator, we quantify RF dissipation in a superconducting qubit caused by hydrogen concentration variation, and propose a practical engineering pathway to mitigate the formation of Nb hydrides for superconducting qubit applications.

Sung, Zuhawn [Fermi National Accelerator Laborator↗

Critical currents of YBCO tapes and Bi-2212 wires at different temperatures and magnetic fields

Design studies for the cooling channel of a Muon Collider call for straight and helical solenoids generating field well in excess of the critical fields of state of the art Low Temperature Superconductors (LTS) such as Nb{sub 3}Sn or NbTi. Therefore, High Temperature Superconductors (HTS) will need to be used for the manufacturing of all or certain sections of such magnets to be able to generate and withstand the field levels at the cryogenic temperatures required by the new machine. In this work, two major High Temperature Superconductors - Bi2212 round wires and YBCO coated conductor tapes - are investigated to understand how critical current density of such conductors scales as a function of external field and operating temperature. This is vital information to make conductor choices depending on the application and to proceed with the design of such magnets.

43 PARTICLE ACCELERATORS↗

Cryogenic X-Ray Diffraction Microscopy for Biological Samples

X-ray diffraction microscopy (XDM) is well suited for nondestructive, high-resolution biological imaging, especially for thick samples, with the high penetration power of x rays and without limitations imposed by a lens. We developed nonvacuum, cryogenic (cryo-) XDM with hard x rays at 8 keV and report the first frozen-hydrated imaging by XDM. By preserving samples in amorphous ice, the risk of artifacts associated with dehydration or chemical fixation is avoided, ensuring the imaging condition closest to their natural state. The reconstruction shows internal structures of intact D. radiodurans bacteria in their natural contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Round Robin Test of Residual Resistance Ratio of Nb $_3$ Sn Composite Superconductors

A round robin test of residual resistance ratio (RRR) was performed for Nb 3 Sn composite superconductors prepared by internal tin method by six institutes with the international standard test method described in IEC 61788-4. It was found that uncertainty mainly resulted from determination of the cryogenic resistance from the intersection of two straight lines drawn to fit the voltage vs. temperature curve around the resistive transition. As a result, the measurement clarified that RRR can be measured with expanded uncertainty not larger than 5% with the coverage factor 2 by using this test method.

43 PARTICLE ACCELERATORS↗

Phase segregation dynamics in mixed-halide perovskites revealed by plunge-freeze cryo-electron microscopy

Mixed-halide lead perovskites, with photoexcited charge-carrier properties suitable for high-efficiency photovoltaics, hold significant promise for high-efficiency tandem solar cells. However, phase segregation under illumination, where an iodide-rich phase forms carrier trap states, remains a barrier to application. This study employs plunge-freeze cryoelectron microscopy to visualize nanoscale phase segregation dynamics in CsPb(Br x I 1–x ) 3 films. By rapidly freezing the illuminated samples, we preserve transient photoexcited ion distributions for high-resolution structural and compositional analysis at the nanoscale. Cryogenic scanning transmission electron microscopy (STEM) techniques (electron energy loss spectroscopy [EELS] and 4D-STEM) captured the dynamics of photo-induced iodine migration from grain boundaries to centers, identified the buildup of anisotropic strain, and captured the heterogeneous evolution of this process within a single grain. These findings provide insight into microscopic phase segregation mechanisms and their dynamics, enhancing our understanding of mixed-halide perovskite photostability.

42 ENGINEERING↗

$\gamma$-to-neutron branching ratio for deuterium-tritium fusion determined using high-energy-density plasmas and a fused silica Cherenkov detector

A fused silica Cherenkov detector was used to measure deuterium-tritium (DT) gammas during a set of 52 direct-drive cryogenic experiments performed at OMEGA. The detector was calibrated using the 4.4 MeV$\gamma$ from the first-excited state of carbon, which is produced when 14-MeV DT neutrons impinge upon a carbon puck. An approximate DT $\gamma$ spectrum as well as neutron yields from a standard neutron time-of-flight detector at OMEGA were used to calculate a DT $\gamma$-to-neutron branching ratio of (8.42 ± 2.84 ) x 10 -5 . Assuming an excited-state to ground-state ratio of 2.1:1, the measurement detailed in this work results in an approximate ground state only$\gamma$-to-neutron branching ratio of 2.72 x 10 -5 . So, this value is somewhat lower than accelerator-based measurements of the ground-state DT $\gamma$ only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of High Order Modes in 1.3 GHZ CW SRF Electron Linac for a Light Source

Design of a Light Source (LS) based on the continuous wave superconducting RF (CW SRF) electron linac is currently underway. This facility will provide soft coherent X-ray radiation for a braod spectrum of basic research applications. Quality of the X-ray laser radiation is affected by the electron beam parameters such as the stability of the transverse beam position and longitudinal and transverse beam emittances. High order modes (HOMs) excited in the SRF structures by a passing beam may deteriorate the beam quality and affect the beam stability. Deposition of HOM energy in the walls of SRF cavities adds to the heat load of he cryogenic system and leads to the increased cost of building and operation of the linac. In this paper we evaluate effects of HOMs in an LS CW SRF linac based on Tesla-type 9-cell 1.3 GHz cavities. We analyze non-coherent losses and resonance excitation of HOMs. We estimate heat load due to the very high frequency HOMs. We study influence of the HOMs on the transverse beam dynamics.

43 PARTICLE ACCELERATORS↗

High Power Electron Gun for Metal Additive Manufacturing Based on Superconducting Technology

E-beam additive manufacturing is a rapidly growingindustry. Electron guns capable of reaching higher energiesand higher average power can enable larger melt pools,higher production speed, and permit broader range ofmaterials for metal additive applications. Such electronguns require technologies beyond those normally achievedwith DC high voltage sources. As an example,superconducting radio frequency (SRF) technology is anoption to achieve higher energy and higher power withexcellent efficiency. However, current SRF technologyrequires complex cryogenic systems to safely handlecryogenics gases or liquids such as Helium. Suchcomplexity severely restricts their usage to R&D facilities.In this talk, we introduce and describe, for the first time, anovel technique based on SRF technology to build a highpower, high energy electron gun for advanced metaladditive manufacturing applications. Our design is based ona technique which eliminates liquid Helium entirely. Ourmethod dramatically reduces the complexity and thusallows building practical, efficient, and modern electronsources for additive manufacturing.

43 PARTICLE ACCELERATORS↗

A Review of the Mechanical Properties of Materials Used in Nb 3 Sn Magnets for Particle Accelerators

Superconducting magnets experience significant thermo-mechanical loads throughout their life cycle. These are introduced by the electro-magnetic forces during powering, but also by the prestress applied in many magnet designs. Further to this, the large thermal excursion that components of different materials experience can generate significant internal forces. The loads are also experienced by the superconducting coils, whose critical current can decrease as a consequence of the applied strain. It is then crucial to predict the overall mechanical behavior and conservatively design a magnet, avoiding failure of the mechanical components and of the superconducting coils. Finite Element Analysis (FEA) is generally used to perform these tasks, but its results rely heavily on the material properties and models used. This is in particular true for the coil composite, which is simplified to allow reasonable model sizes in full magnet models. Here we present the state-of-art knowledge of the mechanical properties of the materials mostly used in superconducting magnet construction. We review elastic and plastic properties at room and cryogenic temperature, thermal contraction, and summarize the state-of-art failure criteria for these materials. Finally, the paper summarizes the present understanding of the mechanical behavior and limits of Nb3Sn coils. For the first time, an orthotropic failure criteria is proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of PIP-II high-beta 650 cryomodule after transatlantic shipping

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

43 PARTICLE ACCELERATORS↗

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.

47 OTHER INSTRUMENTATION↗

LLE Review 114 (January-March 2008)

This volume of the LLE Review, covering January-March 2008, features 'Cryogenic Targets: Current Status and Future Development', by D. R. Harding, D. H. Edgell, M. D. Wittman, L. M. Elasky, S. J. Verbridge, A. J. Weaver, L. D. Lund, W. Seka, W. T. Shmayda, R. T. Janezic, M. J. Shoup III, M. Moore, R. Junquist, and A. V. Okishev. In this article (p. 57), the authors report on the status of layering cryogenic DT and D{sub 2} targets at LLE for inertial confinement fusion (ICF) targets. This critical effort achieves the important milestone of routinely providing cryogenic DT targets that meet the 1.0-{micro}m (rms) OMEGA ice-quality-surface specification. The best D{sub 2}-ice layers produced so far (rms roughness of 1.1 {micro}m) are approaching the quality typically achieved in DT targets. Efforts to improve the consistency of this process are reported along with investigations supporting the National Ignition Campaign studying issues relevant to indirect-drive and direct-drive cryogenic targets. Additional highlights of recent research presented in this issue include the following: (1) an improved laser speckle smoothing scheme that augments the current NIF 1-D SSD system by using multiple-FM modulators (MultiFM 1-D SSD) (p. 73). With a judicious choice of modulator frequencies, MultiFM 1-D SSD smoothes resonances produced at the higher spatial frequencies and can attain similar or even faster smoothing rates compared to the baseline NIF 2-D SSD system. DRACO simulations have shown that MultiFM 1-D SSD beam smoothing is sufficient for the direct-drive-ignition targets and pulse shapes analyzed thus far, and may even allow reducing the bandwidth enough to eliminate the need for dual-tripler frequency conversion on the NIF. (2) describes a time-gated, monoenergetic proton radiography that provides unique measurements of implosion dynamics of spherical targets in direct-drive inertial confinement fusion (ICF) (p. 81). Radiographs obtained at different implosion times, from acceleration, through coasting, deceleration, to final stagnation, display a comprehensive picture of spherical ICF implosion. Critical information inferred from such images characterizes the spatial structure and temporal evolution of self-generated fields and plasma areal density. (3) describes a single-shot cross-correlator based on a pulse replicator that produces a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test (p. 86). The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm, where a dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps. The dynamic range can be extended with standard optical-density filters and the temporal range extended with larger optics. (4) presents a novel focal-spot diagnostic developed for OMEGA EP that will be used to characterize on-shot focal spots to support high-quality laser-matter interaction experiments (p. 94). The complex fields in the region of the high-energy focus are calculated using high-resolution measurements of the main beam wavefront using the focal-spot diagnostic (FSD) located on the short-pulse diagnostic package and a careful calibration of the transfer wavefront between the FSD instrument and target chamber center. The concept of this calibration procedure is experimentally verified in the Multi-Terawatt (MTW) Laser System, which serves as a development platform for OMEGA EP. A technique based on phase retrieval is employed for the transfer-wavefront calibration since the OMEGA EP infrastructure cannot be replicated in the MTW laser; however, this approach also shows promise as an alternative method for OMEGA EP. (5) report on a systematic study to improve the laser-damage resistance of multilayer high-reflector coatings for use at 351 nm on the OMEGA EP Laser System (p. 103). A series of ha

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MD simulations of resistive cooling in HITRAP using GPUs

In the HITRAP facility at GSI it is planned to store 10{sup 5} highly charged ions up to U{sup 92+} in a cryogenic Penning trap and cool them down to 4 K via electron and resistive cooling. During the cooling process the ion density increases and the characteristics of the ion cloud are increasingly determined by Coulomb interactions. We present a parallel algorithm for the simulation of the resistive cooling for ion clouds in cylindrical Penning traps. For the simulation of the resistive cooling we run an Open Cl code on a single GPU device.

43 PARTICLE ACCELERATORS↗

Where are the AGS snakes?

A series of questions have arisen, in preparation to the polarized protons RHIC Run 13, and of future polarized helion runs, regarding the field settings as well as the spin precession angles in the AGS warm and cryogenic helical partial snakes. This is the main reason for the present studies, which consist essentially in re-visiting and clarifying various parameters of the snakes, and assessing their optimum settings. This work also led to a re-assessment of the periodic stable spin precession axis in the AGS at extraction, and of its transport to RHIC; this is briefly reported here and will be subject to a detailed companion Tech.

43 PARTICLE ACCELERATORS↗