Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Weak-lensing magnification as a probe for the dark Universe

This Thesis is devoted to the analysis of weak-lensing magnification on the Dark Energy Survey. Two analysis with different goals each are made on different data-sets: the Science Verification (DES-SV) and the Year 1 (DES-Y1). The DES-SV analysis aims the development of techniques to detect the weak-lensing number count magnification signal and the mitigation of systematic errors. The DES-Y1 analysis employs the methods used with the DES-SV data to measure the convergence profile of the emptiest regions of the Universe –voids and troughs–to use them as a new cosmological probe.

79 ASTRONOMY AND ASTROPHYSICS↗

Geospatial Modeling and Simulation Based Approach for Developing Commuting patterns of School Children

Numerous socio-environmental studies, including those in public health, utilize population data as one of the essential elements of modeling and analysis. Typically population data are reported by administrative or accounting units. For example, in the US the Census Bureau reports population counts by census blocks, block groups, and tracts. At any resolution, a uniform population distribution is assumed and the population figures and demographic characteristics are typically associated with block (polygon) centroids. In geographic analyses these points are considered representative of the population for census polygons. Traditional spatial modeling approaches commonly include intersection of census data with buffers of influence to quantify target population, using either inclusion-exclusion (of the centroids) or the area weighted population estimation methods. However, it is well understood that uniform population distribution is the weakest assumption and by considering census polygon centroids as representative of population all analytical approaches are very likely to overestimate or underestimate the analytical results. Given that population is spatially restricted by Census accounting units (such as blocks), there often is great uncertainty about spatial distribution of residents within those accounting units. This is particularly appropriate in suburban and rural areas, where the population is dispersed to a greater degree than urban areas. Because of this uncertainty, there is significant potential to misclassify people with respect to their location from pollution sources, and consequently it becomes challenging to determine if certain sub-populations are actually more likely than others to get differential environmental exposure. In this paper, we describe development and utilization of a high resolution demographic data driven approach for modeling and simulation at Oak Ridge National Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Technical Evaluation Report for the NDMAS AGR-5/6/7 TRISO Irradiation Monitoring System

The Nuclear Data Management and Analysis System (NDMAS) manages irradiation experiment data collected under the Advanced Gas Reactor (AGR) Fuel Development and Qualification program within the Advanced Reactor Technologies Technology Development Office. The AGR-5/6/7 irradiation experiment combines the fifth, sixth, and seventh planned irradiation campaigns of the U.S. Department of Energy AGR Fuel Development and Qualification Program. These combined irradiation tests will consist of fuel qualification tests (AGR-5/6) and a margin test (AGR-7) for the industrially produced uranium oxycarbide (UCO) tristructural isotropic (TRISO) coated particle fuel developed by the AGR program. The objective of the AGR-5/6/7 irradiation experiment is to establish the performance of UCO TRISO fuel fabricated using engineering-scale equipment in a production environment under and beyond normal operating conditions (PNL-5245). Experimental irradiation measurements for this experiment (i.e., thermocouple temperature, gas flow rate, fission product release rate, gross gamma count, and Advanced Test Reactor (ATR) operational parameters) are captured automatically to the NDMAS database. Data derived from numerical simulation or other mathematical analyses (i.e., fast fluence, burnup, temperature, and fission product release to birth ratio) are captured to the database when provided by the researchers. The NDMAS database is a relational database accessed via structured query language and managed with Microsoft SQL Server. While select users can directly access the database, that is not the most convenient way to interact with the data. The NDMAS team constructs numerous tables that combine related datasets, and delivers those data to researchers via graphs and spreadsheets on a Microsoft SharePoint-based website. For the AGR-5/6/7 experimental data, a new subsite has been developed, along with a set of web pages. These pages will be used by members of fuel irradiation team for monitoring irradiation conditions according to specification (SPC-1749), by the physics modelers to access necessary model inputs, and by the nuclear engineering community to view and access data such as fuel temperatures, fission product release from capsules, and ATR operational parameters. The deliverable represented in this document is a SharePoint website containing tables of the AGR-5/6/7 measured and calculated data, graphs displaying the data, and links to source documents and references.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Irradiation Monitoring Web Site Design

The Nuclear Data Management and Analysis System (NDMAS) manages irradiation experiment data collected under the Advanced Gas Reactor (AGR) Fuel Development and Qualification program within the Advanced Reactor Technologies Technology Development Office. The AGR-5/6/7 irradiation experiment combines the fifth, sixth, and seventh planned irradiation campaigns of the U.S. Department of Energy AGR Fuel Development and Qualification Program. These combined irradiation tests will consist of fuel qualification tests (AGR-5/6) and a margin test (AGR-7) for the industrially produced uranium oxycarbide (UCO) tristructural isotropic (TRISO) coated particle fuel developed by the AGR program. The objective of the AGR-5/6/7 irradiation experiment is to establish the performance of UCO TRISO fuel fabricated using engineering-scale equipment in a production environment under and beyond normal operating conditions (PNL-5245). Experimental irradiation measurements for this experiment (i.e., thermocouple temperature, gas flow rate, fission product release rate, gross gamma count, and Advanced Test Reactor (ATR) operational parameters) are captured automatically to the NDMAS database. Data derived from numerical simulation or other mathematical analyses (i.e., fast fluence, burnup, temperature, and fission product release to birth ratio) are captured to the database when provided by the researchers. The NDMAS database is a relational database accessed via structured query language and managed with Microsoft SQL Server. While select users can directly access the database, that is not the most convenient way to interact with the data. The NDMAS team constructs numerous tables that combine related datasets, and delivers those data to researchers via graphs and spreadsheets on a Microsoft SharePoint-based website. For the AGR-5/6/7 experimental data, a new subsite has been developed, along with a set of web pages. These pages will be used by members of fuel irradiation team for monitoring irradiation conditions according to specification (SPC-1749), by the physics modelers to access necessary model inputs, and by the nuclear engineering community to view and access data such as fuel temperatures, fission product release from capsules, and ATR operational parameters. The deliverable represented in this document is a SharePoint website containing tables of the AGR-5/6/7 measured and calculated data, graphs displaying the data, and links to source documents and references.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electronic spectra from TDDFT and machine learning in chemical space

Due to its favorable computational efficiency, time-dependent (TD) density functional theory (DFT) enables the prediction of electronic spectra in a high-throughput manner across chemical space. Its predictions, however, can be quite inaccurate. We resolve this issue with machine learning models trained on deviations of reference second-order approximate coupled-cluster (CC2) singles and doubles spectra from TDDFT counterparts, or even from DFT gap. We applied this approach to low-lying singlet-singlet vertical electronic spectra of over 20 000 synthetically feasible small organic molecules with up to eight CONF atoms. The prediction errors decay monotonously as a function of training set size. For a training set of 10 000 molecules, CC2 excitation energies can be reproduced to within ±0.1 eV for the remaining molecules. Analysis of our spectral database via chromophore counting suggests that even higher accuracies can be achieved. Based on the evidence collected, we discuss open challenges associated with data-driven modeling of high-lying spectra and transition intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPITZER 70 AND 160 {mu}m OBSERVATIONS OF THE COSMOS FIELD

We present Spitzer 70 and 160 {mu}m observations of the COSMOS Spitzer survey (S-COSMOS). The data processing techniques are discussed for the publicly released products consisting of images and source catalogs. We present accurate 70 and 160 {mu}m source counts of the COSMOS field and find reasonable agreement with measurements in other fields and with model predictions. The previously reported counts for GOODS-North and the extragalactic First Look Survey are updated with the latest calibration, and counts are measured based on the large area SWIRE survey to constrain the bright source counts. We measure an extragalactic confusion noise level of {sigma} {sub c} = 9.4 {+-} 3.3 mJy (q = 5) for the MIPS 160 {mu}m band based on the deep S-COSMOS data and report an updated confusion noise level of {sigma} {sub c} = 0.35 {+-} 0.15 mJy (q = 5) for the MIPS 70 {mu}m band.

79 ASTRONOMY AND ASTROPHYSICS↗

Freeway Loop Detector Data Reconciliation Based on Vehicle Conservation

Loop detector is the most common source of traffic flow measurements on freeways. Though being a mature technology, loop detector is prone to miscounts even when it is properly deployed and adjusted. If a loop detectors systematically over- or under-counts, the estimation based on vehicle conservation leads to results that are not physically plausible such as negative density or density higher than the jam-density. Here we propose an optimization-based method in which plausible values of accumulation is guaranteed through explicit constraints. Compared to similar methods, the proposed method distinct in the following: (i) the optimization problem is convex therefore leads to shorter computational time; (ii) occupancy is also taken into account in order to estimate upper and lower bounds in the accumulation between stations; (iii) no modifications are required when data from one or multiple lanes are missing. The method is first validated using micro-simulation by disturbing the loop-detector from micro-simulation, applying the method and then comparing the results with the ground truth data. The results show the method is able to capture the average counts almost exactly while providing estimate of density with satisfactory accuracy. The method is also successfully applied in a scenario in which field-data is available.

data reconciliation↗

A METHOD FOR INDIVIDUAL SOURCE BRIGHTNESS ESTIMATION IN SINGLE- AND MULTI-BAND DATA

We present a method of reliable extraction of the flux of individual sources from sky maps in the presence of noise and a source population in which number counts are a steeply falling function of flux. The method is an extension of a standard Bayesian procedure in the millimeter/submillimeter literature. As in the standard method, the prior applied to source flux measurements is derived from an estimate of the source counts as a function of flux, dN/dS. The key feature of the new method is that it enables reliable extraction of properties of individual sources, which previous methods in the literature do not. We first present the method for extracting individual source fluxes from data in a single observing band, then we extend the method to multiple bands, including prior information about the spectral behavior of the source population(s). The multi-band estimation technique is particularly relevant for classifying individual sources into populations according to their spectral behavior. We find that proper treatment of the correlated prior information between observing bands is key to avoiding significant biases in estimations of multi-band fluxes and spectral behavior, biases which lead to significant numbers of misclassified sources. We test the single- and multi-band versions of the method using simulated observations with observing parameters similar to that of the South Pole Telescope data used in Vieira et al.

79 ASTRONOMY AND ASTROPHYSICS↗

REGULARITY OF THE NORTH–SOUTH ASYMMETRY OF SOLAR ACTIVITY: REVISITED

Extended time series of Solar Activity Indices (ESAI) extended the Greenwich series of sunspot area from the year 1874 back to 1821. The ESAI's yearly sunspot area in the northern and southern hemispheres from 1821 to 2013 is utilized to investigate characteristics of the north–south hemispherical asymmetry of sunspot activity. Periodical behavior of about 12 solar cycles is also confirmed from the ESAI data set to exist in dominant hemispheres, linear regression lines of yearly asymmetry values, and cumulative counts of yearly sunspot areas in the hemispheres for solar cycles. The period is also inferred to appear in both the cumulative difference in the yearly sunspot areas in the hemispheres over the entire time interval and in its statistical Student's t-test. The hemispherical bias of sunspot activity should be regarded as an impossible stochastic phenomenon over a long time period.

79 ASTRONOMY AND ASTROPHYSICS↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterisation of radiation damage in W and W-based alloys from 2MeV self-ion near-bulk implantations

The displacement damage induced in bulk W and W-5 wt.% Re and W-5 wt.% Ta alloys by 2 MeV W + irradiation to doses 3.3×10 17 - 2.5×10 19 W + /m 2 at temperatures ranging from 300 to750°C has been characterized by transmission electron microscopy. An automated sizing and counting approach based on Image J has been proposed and performed for all irradiation data. In all cases the damage comprised dislocation loops, mostly of interstitial type, with Burgers vectors b = ½<111> (> 60%) and b = <100>. The diameters of loops did not exceed 20 nm, with the majority being ≤ 6 nm. The loop number density varied between 10 22 and 10 23 loops/m 3 . With increasing irradiation temperature, the loop size distributions shifted towards larger sizes, and there was a substantial decrease in loop number densities. The damage microstructure was less sensitive to dose than to temperature. Under the same irradiation conditions, loop number densities in the alloys were higher than in pure W but loops were smaller. In grains with normals close to z = <001>, loop strings developed in W at temperatures ≥ 500°C and doses ≥ 1.2 dpa, but such strings were not observed in the W-Re or W-Ta alloys. However, in other grain orientations complex structures appeared in all materials and dense dislocation networks formed at higher doses.

36 MATERIALS SCIENCE↗

The use of analgesics for intentional self-poisoning: Trends in U.S. poison center data

In the U.S., intentional self-poisonings with analgesics that are available without a prescription increased from 2000 to 2018. Given concerns regarding mental health outcomes during the COVID-19 pandemic, we examined and compared trends in pediatric and adult intentional self-poisoning with acetaminophen, aspirin, ibuprofen, and naproxen from 2016 to 2021 using the National Poison Data System (NPDS) to see if these trends have continued. We extracted annual case counts of all suspected suicide attempts from intentional poisoning, and of suspected suicide attempts resulting in major effects or death, from the NPDS for non-prescription single ingredient adult formulation acetaminophen, non-prescription single ingredient adult formulation aspirin, single ingredient formulation ibuprofen, and single ingredient formulation naproxen. We enumerated the cases by year, age, and gender. Most cases of intentional self-poisoning within the review period involved acetaminophen and ibuprofen and the 13–19-year-olds constituted the highest proportion of intentional self-poisoning cases across age groups for all four analgesics. Cases involving females predominated cases involving males by 3:1 or greater. Here, the 13–19-year-old age group also represented the largest proportion of cases that resulted in major clinical effects or deaths. An increasing trend in suicide poisoning cases with acetaminophen and ibuprofen was observed in the 6-19-years age group and this trend appeared to exacerbate from 2020 to 2021 corresponding with the start of the COVID-19 pandemic period.

60 APPLIED LIFE SCIENCES↗

Using the JCC-71 neutron coincidence collar as a benchmark for detector characterization with PTR-32 list mode data acquisition

Augmenting or interchanging current international safeguards shift registerbased data acquisition systems with list mode data acquisition systems gives nondestructive assay (NDA) systems greater versatility. Neutron list mode data analysis offers comparable analytical results to the more widely used shift register analysis in nuclear material quantification applications and offers several diagnostic tools that are specifically beneficial to in-laboratory characterization and calibration measurements. These benefits include identification of non-ideal behavior, optimization of operational parameters from a single measurement, and an improved understanding of the physics-based behavior of NDA systems for a more precise system representation and more confident assay results. In this work the advantages of using list mode data acquisition for detector characterization are demonstrated experimentally. Two commercial-off-the-shelf International Atomic Energy Agency-supported technologies are used for a typical detector characterization procedure and their performance is compared. Specifically, a 3 He-based Canberra Industries JCC-71 Neutron Coincidence Collar is characterized using the Hungarian Institute of Isotopes’ Pulse Train Recorder-32 (PTR-32) list mode data acquisition system, and the results are compared to those obtained using the standard Canberra Industries JSR-15 model shift register. The quantitative results from the two systems are in agreement, which demonstrates that the PTR-32 is a technically viable alternative to conventional shift register electronics for this task. A suitable procedure for full instrument characterization is described, and the added benefits of list mode for characterization and data collection are discussed. Furthermore, this is an important step toward establishing a procedure for the routine use of list mode data acquisition and analysis for neutron NDA system characterization in safeguards field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-cell measurement of plasmid copy number and promoter activity

Abstract Accurate measurements of promoter activities are crucial for predictably building genetic systems. Here we report a method to simultaneously count plasmid DNA, RNA transcripts, and protein expression in single living bacteria. From these data, the activity of a promoter in units of RNAP/s can be inferred. This work facilitates the reporting of promoters in absolute units, the variability in their activity across a population, and their quantitative toll on cellular resources, all of which provide critical insights for cellular engineering.

59 BASIC BIOLOGICAL SCIENCES↗

The ECLAIRs telescope onboard the SVOM mission for gamma-ray burst studies

The X- and gamma-ray telescope ECLAIRs onboard the future mission for gamma-ray burst studies SVOM (Space-based multi-band astronomical Variable Objects Monitor) is foreseen to operate in orbit from 2013 on. ECLAIRs will provide fast and accurate GRB triggers to other onboard telescopes, as well as to the whole GRB community, in particular ground-based follow-up telescopes. With its very low energy threshold ECLAIRs is particularly well suited for the detection of highly redshifted GRB. The ECLAIRs X- and gamma-ray imaging camera (CXG), used for GRB detection and localization, is combined with a soft X-ray telescope (SXT) for afterglow observations and position refinement. The CXG is a 2D-coded mask imager with a 1024 cm{sup 2} detection plane made of 80x80 CdTe pixels, sensitive from 4 to 300 keV, with imaging capabilities up to about 120 keV and a localization accuracy better than 10 arcmin. The CXG permanently observes a 2 sr-wide field of the sky and provides photon data to the onboard science and triggering unit (UTS) which detects GRB by count-rate increases or by the appearance of a new source in cyclic sky images. The SXT is a mirror focusing X-ray telescope operating from 0.3 to 2 keV with a sensitivity of 1 mCrab for 100 s observations. The spacecraft slews within {approx_equal}3 min in order to place the GRB candidate into the 23x23 arcmin{sup 2} field of view of the SXT, after which it refines the GRB position to about 10 arcsec. GRB alerts are transmitted to ground-observers within tens of seconds via a VHF network and all detected photons are available hours later for detailed analysis. In this paper we present the ECLAIRs concepts, with emphasis on the expected performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of double beta decay of {sup 116}Cd with the help of enriched {sup 116}CdWO{sub 4} crystal scintillators

An experiment to search for 2β processes in {sup 116}Cd with the help of enriched (to 82%) cadmium tungstate crystal scintillators is in progress at the Gran Sasso National Laboratory of the INFN (LNGS, Italy). After 11074 h of data taking in the last configuration, the preliminary estimate for the half-life of 116Cd relatively to 2ν2β decay is T{sub 1/2} = [2.52 ± 0.02(stat.) ± 0.14(syst.)] × 10{sup 19} yr. By using the data of previous stages of the experiment with a similar level of background (≈ 0.1 counts/(keV kg yr) in the energy interval 2.7 – 2.9 MeV; the total time of measurements is 19770 h) we have obtained a new limit on the 0ν2β decay of {sup 116}Cd to the ground state of {sup 116}Sn: T{sub 1/2} ≥ 1.9 × 10{sup 23} yr at 90% C.L. New limits on different 2β processes in {sup 116}Cd (decays with majorons, transitions to the excited levels) are obtained on the level of T{sub 1/2} ≥ 10{sup 20} – 10{sup 22} yr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-scale determination of spontaneous magnetic reversal in oxide heterostructures

Interfaces between transition metal oxides are known to exhibit emerging electronic and magnetic properties. Here we report intriguing magnetic phenomena for La 2/3 Sr 1/3 MnO 3 films on an SrTiO 3 (001) substrate (LSMO/STO), where the interface governs the macroscopic properties of the entire monolithic thin film. The interface is characterized on the atomic level utilizing scanning transmission electron microscopy and electron energy loss spectroscopy (STEM-EELS), and density functional theory (DFT) is employed to elucidate the physics. STEM-EELS reveals mixed interfacial stoichiometry, subtle lattice distortions, and oxidation-state changes. Magnetic measurements combined with DFT calculations demonstrate that a unique form of antiferromagnetic exchange coupling appears at the interface, generating a novel exchange spring-type interaction that results in a remarkable spontaneous magnetic reversal of the entire ferromagnetic film, and an inverted magnetic hysteresis, persisting above room temperature. Formal oxidation states derived from electron spectroscopy data expose the fact that interfacial oxidation states are not consistent with nominal charge counting. The present work demonstrates the necessity of atomically resolved electron microscopy and spectroscopy for interface studies. Theory demonstrates that interfacial nonstoichiometry is an essential ingredient, responsible for the observed physical properties. The DFT-calculated electrostatic potential is flat in both the LSMO and STO sides (no internal electric field) for both Sr-rich and stoichiometric interfaces, while the DFT-calculated charge density reveals no charge transfer/accumulation at the interface, indicating that oxidation-state changes do not necessarily reflect charge transfer and that the concept of polar mismatch is not applicable in metal−insulator polar−nonpolar interfaces.

36 MATERIALS SCIENCE↗

QUASAR-GALAXY CLUSTERING THROUGH PROJECTED GALAXY COUNTS AT z = 0.6-1.2

We investigate the spatial clustering of galaxies around quasars at z = 0.6-1.2 using photometric data from Sloan Digital Sky Survey Stripe 82. The quasar and galaxy cross-correlation functions are measured through the projected galaxy number density n(r{sub p} ) on scales of 0.05 < r{sub p} < 20 h {sup -1} Mpc around quasars for a sample of 2300 quasars from Schneider et al. We detect strong clustering signals at all redshifts and find that the clustering amplitude increases significantly with redshift. We examine the dependence of quasar-galaxy clustering on quasar and galaxy properties and find that the clustering amplitude is significantly larger for quasars with more massive black holes or with bluer colors, while there is no dependence on quasar luminosity. We also show that quasars have a stronger correlation amplitude with blue galaxies than with red galaxies. We finally discuss the implications of our findings.

79 ASTRONOMY AND ASTROPHYSICS↗