Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A Concise Method for Storing and Communicating the Data Covariance Matrix

The covariance matrix associated with experimental cross section or transmission data consists of several components. Statistical uncertainties on the measured quantity (counts) provide a diagonal contribution. Off-diagonal components arise from uncertainties on the parameters (such as normalization or background) that figure into the data reduction process; these are denoted systematic or common uncertainties, since they affect all data points. The full off-diagonal data covariance matrix (DCM) can be extremely large, since the size is the square of the number of data points. Fortunately, it is not necessary to explicitly calculate, store, or invert the DCM. Likewise, it is not necessary to explicitly calculate, store, or use the inverse of the DCM. Instead, it is more efficient to accomplish the same results using only the various component matrices that appear in the definition of the DCM. Those component matrices are either diagonal or small (the number of data points times the number of data-reduction parameters); hence, this implicit data covariance method requires far less array storage and far fewer computations while producing more accurate results.

97 MATHEMATICS AND COMPUTING↗

Support of selected X-ray studies to be performed using data from the Uhuru (SAS-A) satellite

A new measurement of the diffuse X-ray emission sets more stringent upper limits on the fluctuations of the background and on the number counts of X-ray sources with absolute value of b 20 deg than previous measurements. A random sample of background data from the Uhuru satellite gives a relative fluctuation in excess of statistics of 2.0% between 2.4 and 6.9 keV. The hypothesis that the relative fluctuation exceeds 2.9% can be rejected at the 90% confidence level. No discernable energy dependence is evident in the fluctuations in the pulse height data, when separated into three energy channels of nearly equal width from 1.8 to 10.0 keV. The probability distribution of fluctuations was convolved with the photon noise and cosmic ray background deviation (obtained from the earth-viewing data) to yield the differential source count distribution for high latitude sources. Results imply that a maximum of 160 sources could be between 1.7 and 5.1 x 10 to the -11 power ergs/sq cm/sec (1-3 Uhuru counts).

Garmire, G. P.↗

Investigation of radiometric properties of the LANDSAT-4 multispectral scanner

The radiometric data quality of the LANDSAT 4 multispectral scanner (MSS) was examined using several LANDSAT 4 frames. It was found that LANDSAT 4 MSS produces high-quality data of the caliber experienced with previous LANDSATS. For example, the detector equalization procedure worked well, leaving a residual banding effect of about 0.3 digital counts RMS, close to the theoretical minimum value of quantization error. Nevertheless, artifacts of the data were found, two of which were not experienced in previous MSS data. A low-level coherent noise effect was observed in all bands, with a magnitude of about 0.5 digital counts and a frequency of approximately 28 KHz (representing a wavelength of about 3.6 pixels); a substantial increase in processing complexity would be required to reduce this artifact in the data. Also, a substantial scan-length variation (of up to six pixels) was noted in MSS data when the TM sensor was operating; the LANDSAT 4 correction algorithms being applied routinely by the EROS Data Center to produce a p-type data should remove most of this variation. Between-satellite calibrations were examined in paired LANDSAT 3 and LANDSAT 4 MSS data sets, which were closely matched in acquisition time and place. Radiometric comparisons showed that all bands were highly linear in digital counts, and a well-determined linear transformation between the MSS's was established.

Malila, W. A.↗

The structure of eight globular clusters

Star counts on short-exposure plates are presented for eight globular clusters. The data are given to several limiting magnitudes for each cluster. Projected radial distributions are determined from the star counts; no significant segregation is observed among the distributions to various limiting magnitudes. The structural parameters of the clusters (core radii and concentration factors) are determined from best-fitting King curves to the observed distributions. The central densities, total masses, central escape velocities, and relaxation times are also calculated. NGC 6093 (M80) and NGC 7099 (M30) have dense compact stellar cores, similar to the established globular X-ray sources. Upper limits are given for the masses of possible central black holes in the eight clusters.

Bahcall, N. A.↗

Data for "Understanding multiscale disorder in superconducting nanowire single photon detectors"

This dataset addresses DC transport, dark-count measurements, and bias-dependent microwave transmission spectroscopy of superconducting nanowire. This publication includes the raw and processed data to produce figures in the paper "Understanding multiscale disorder in superconducting nanowire single photon detectors" (Sarkar et al., 2026).

Sarkar, Nirjhar [Oak Ridge National Laboratory] (O↗

Evaluation of a digital data acquisition system and optimization of n-{gamma} discrimination for a compact neutron spectrometer

A compact NE213 liquid scintillation neutron spectrometer with a new digital data acquisition (DAQ) system is now in operation at the Physikalisch-Technische Bundesanstalt (PTB). With the DAQ system, developed by ENEA Frascati, neutron spectrometry with high count rates in the order of 5x10{sup 5} s{sup -1} is possible, roughly an order of magnitude higher than with an analog acquisition system. To validate the DAQ system, a new data analysis code was developed and tests were done using measurements with 14-MeV neutrons made at the PTB accelerator. Additional analysis was carried out to optimize the two-gate method used for neutron and gamma (n-{gamma}) discrimination. The best results were obtained with gates of 35 ns and 80 ns. This indicates that the fast and medium decay time components of the NE213 light emission are the ones that are relevant for n-{gamma} discrimination with the digital acquisition system. This differs from what is normally implemented in the analog pulse shape discrimination modules, namely, the fast and long decay emissions of the scintillating light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-18A-04: Use of An Image-Based Material-Decomposition Algorithm for Multi-Energy CT to Determine Basis Material Densities

Purpose: Published methods for image-based material decomposition with multi-energy CT images have required the assumption of volume conservation or accurate knowledge of the x-ray spectra and detector response. The purpose of this work was to develop an image-based material-decomposition algorithm that can overcome these limitations. Methods: An image-based material decomposition algorithm was developed that requires only mass conservation (rather than volume conservation). With this method, using multi-energy CT measurements made with n=4 energy bins, the mass density of each basis material and of the mixture can be determined without knowledge of the tube spectra and detector response. A digital phantom containing 12 samples of mixtures from water, calcium, iron, and iodine was used in the simulation (Siemens DRASIM). The calibration was performed by using pure materials at each energy bin. The accuracy of the technique was evaluated in noise-free and noisy data under the assumption of an ideal photon-counting detector. Results: Basis material densities can be estimated accurately by either theoretic calculation or calibration with known pure materials. The calibration approach requires no prior information about the spectra and detector response. Regression analysis of theoretical values versus estimated values results in excellent agreement for both noise-free and noisy data. For the calibration approach, the R-square values are 0.9960+/−0.0025 and 0.9476+/−0.0363 for noise-free and noisy data, respectively. Conclusion: From multi-energy CT images with n=4 energy bins, the developed image-based material decomposition method accurately estimated 4 basis material density (3 without k-edge and 1 with in the range of the simulated energy bins) even without any prior information about spectra and detector response. This method is applicable to mixtures of solutions and dissolvable materials, where volume conservation assumptions do not apply. CHM receives research support from NIH and Siemens Healthcare.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seasonal Disorder in Urban Traffic Patterns: A Low Rank Analysis

This article proposes several advances to sparse nonnegative matrix factorization (SNMF) as a way to identify large-scale patterns in urban traffic data. The input to our model is traffic counts organized by time and location. Nonnegative matrix factorization additively decomposes this information, organized as a matrix, into a linear sum of temporal signatures. Penalty terms encourage this factorization to concentrate on only a few temporal signatures, with weights which are not too large. Our interest here is to quantify and compare the regularity of traffic behavior, particularly across different broad temporal windows. In addition to the rank and error, we adapt a measure introduced by Hoyer to quantify sparsity in the representation. Combining these, we construct several curves which quantify error as a function of rank (the number of possible signatures) and sparsity; as rank goes up and sparsity goes down, the approximation can be better and the error should decreases. Plots of several such curves corresponding to different time windows leads to a way to compare disorder/order at different time scalewindows. In this paper, we apply our algorithms and procedures to study a taxi traffic dataset from New York City. In this dataset, we find weekly periodicity in the signatures, which allows us an extra framework for identifying outliers as significant deviations from weekly medians. We then apply our seasonal disorder analysis to the New York City traffic data and seasonal (spring, summer, winter, fall) time windows. We do find seasonal differences in traffic order.

97 MATHEMATICS AND COMPUTING↗

The faint limit of the Hubble Space Telescope faint object spectrograph and rejection of the cosmic-ray background

The faintest object which can be observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) is set by the detector cosmic-ray background and not by object flux. We use data from Beaver and Lyons to show that 48% of the background counts are from cosmic rays which each generate a near instantaneous burst of two or more counts. Setting the FOS threshold parameter REJLIM = 1, which rejects all frames with more than one count increases the ratio of signal-to-dark counts (S/D) by a factor of 1.94, regardless of the frame time or the object signal, because half of the dark counts which arrive in single counts (from either cosmic-ray bursts or thermal dark current photoemission) are rejected at the same rate as the object signal. But the signal-to-noise ratio (SNR proportional to S/square root of S + D) increases by at most a factor of 1.35, and for realistic parameters and taking into account dead time, we expect a gain in SNR of only 1.18. If a diode has failed and now emits noise, no data at all will be recorded. The chance of this occurring is approximately = 10% , and for this reason we do not recommend the use of REJLIM. The two-point correlation function of dark counts per pixel has strong peaks every four pixels, caused by the action of quarter-stepping on the counts from large bursts. The counts from such bursts spread over at least 80-100 diodes, and we show that such bursts can be rejected during data reduction if the data are recorded in RAPID mode with individual exposures of about 35 seconds. The SNR of the spectrum can also be improved by weighting each exposure by its SNR (a function ofthe mean dark count rate at that time), since dark varies by a factor of 2 around an orbit. These two procedures together increase the SNR by a factor of 1.1.3 (a 28% gain in exposure time) in regions of a spectrum where the object is much fainter than the background. We find that the Ly-alpha and O I sky emission lines give at most 4 (counts/array/s/sq arcsec), and typically half this number. With a small frame time and a small entrance aperture, these counts cause REJLIM = 1 to reject only a few percent of the data. We discuss only the HST FOS blue side detector, but the same ideas apply to any photon counter which records bursts of noise, and the calculations resemble those for the loss of signal due to coincidences in photon counters. In the ideal photon counter the dark counts are readily distinguished from photons. One way to do this is to add detectors which records only dark current, so that every cosmic ray produces more than one count and the instrument can be operated in an anti-coincidence mode.

Tytler, David↗

Modeling the stellar contribution to the Galactic component of the diffuse soft X-ray background. I - Background fluxes and number counts

A combination of a stellar Galaxy model based on optical data, stellar X-ray luminosity functions derived from the full Einstein base, and a model for X-ray absorption derived from hydrogen column densities are used to estimate the contribution to the diffuse soft X-ray background flux from the main-sequence A, F, G, K, and M stars, and RS CVn stars, at various energies ranging from 0.1 to about 5 keV. Previous discrepancies between earlier estimates of the stellar contribution to the diffuse soft X-ray background are resolved; this stellar contribution to the diffuse soft X-ray background is found to be under 3 percent for photon energies less than energy I and J bands (about 0.8-2 keV), at a threshold sensitivity for point source detection about 10 exp -10 ergs/s sq cm. At low latitudes, stellar contribution estimates are less than 3 percent below 0.3 keV, 7-40 percent in the medium-energy bands, and 27-70 percent in the I and J bands. It is shown that while dM stars are the major contributors to the diffuse stellar flux, other stellar types contribute as much as 40 percent of this flux at the higher energies in the passband studied.

Kashyap, V.↗

BOREAS Landsat MSS Imagery: Digital Counts

The Boreal Ecosystem-Atmospheric Study (BOREAS) Staff Science Satellite Data Acquisition Program focused on providing the research teams with the remotely sensed satellite data products they needed to compare and spatially extend point results. The Earth Resources Technology Satellite (ERTS) Program launched the first of a series of satellites (ERTS-1) in 1972. Part of the NASA Earth Resources Survey Program, the ERTS Program and the ERTS satellites were later renamed Landsat to better represent the civil satellite program's prime emphasis on remote sensing of land resources. Landsat satellites 1 through 5 carry the Multispectral Scanner (MSS) sensor. Canada for Remote Sensing (CCRS) and BOREAS personnel gathered a set of MSS images of the BOREAS region from Landsat satellites 1, 2, 4, and 5 covering the dates of 21 Aug 1972 to 05 Sep 1988. The data are provided in binary image format files of various formats. The Landsat MSS imagery is available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hall, Forrest G.↗

Pulse shape discrimination of Cs 2 LiYCl 6 :Ce 3+ detectors at high count rate based on triangular and trapezoidal filters

Cs 2 LiYCl 6 :Ce 3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. In this work, a disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. Finally, they are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A HYBRID MODEL FOR THE EVOLUTION OF GALAXIES AND ACTIVE GALACTIC NUCLEI IN THE INFRARED

We present a comprehensive investigation of the cosmological evolution of the luminosity function of galaxies and active galactic nuclei (AGNs) in the infrared (IR). Based on the observed dichotomy in the ages of stellar populations of early-type galaxies on one side and late-type galaxies on the other, the model interprets the epoch-dependent luminosity functions at z {>=} 1.5 using a physical approach for the evolution of proto-spheroidal galaxies and of the associated AGNs, while IR galaxies at z < 1.5 are interpreted as being mostly late-type ''cold'' (normal) and ''warm'' (starburst) galaxies. As for proto-spheroids, in addition to the epoch-dependent luminosity functions of stellar and AGN components separately, we have worked out, for the first time, the evolving luminosity functions of these objects as a whole (stellar plus AGN component), taking into account in a self-consistent way the variation with galactic age of the global spectral energy distribution. The model provides a physical explanation for the observed positive evolution of both galaxies and AGNs up to z {approx_equal} 2.5 and for the negative evolution at higher redshifts, for the sharp transition from Euclidean to extremely steep counts at (sub-)millimeter wavelengths, as well as the (sub-)millimeter counts of strongly lensed galaxies that are hard to account for by alternative, physical or phenomenological, approaches. The evolution of late-type galaxies and z < 1.5 AGNs is described using a parametric phenomenological approach. The modeled AGN contributions to the counts and to the cosmic infrared background (CIB) are always sub-dominant. They are maximal at mid-IR wavelengths: the contribution to the 15 and 24 {mu}m counts reaches 20% above 10 and 2 mJy, respectively, while the contributions to the CIB are of 8.6% and of 8.1% at 15 {mu}m and 24 {mu}m, respectively. The model provides a good fit to the multi-wavelength (from the mid-IR to millimeter waves) data on luminosity functions at different redshifts and on number counts (both global and per redshift slices). A prediction of the present model, useful to test it, is a systematic variation with wavelength of the populations dominating the counts and the contributions to the CIB intensity. This implies a specific trend for cross-wavelength CIB power spectra, which is found to be in good agreement with the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

Evaluation of sliding baseline methods for spatial estimation for cluster detection in the biosurveillance system

Background: The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods: The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results: Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion: The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement.

59 BASIC BIOLOGICAL SCIENCES↗

An experimental comparison of triggered and random pulse train uncertainties

In this paper we present an experimental comparison of signal-triggered and randomly triggered based analysis algorithms of neutron multiplicity data. Traditional shift register type signal-triggered multiplicity analysis of singles, doubles and triples rates is compared with analysis using randomly triggered gates. Two methods of random gate generation are explored - non-overlapping gates (Feyrunan approach) and periodic overlapping gates (fast accidentals). Using californium sources with low, medium and high rate in combination with AmLi sources (as a surrogate for plutonium) we investigate relative standard deviation (RSD) of data in order to determine if there are parameter spaces in which one of the measurement methods should be preferred. Neutron correlation analysis is a commonly used NDA technique to assay plutonium mass. The data can be collected in two distinct ways: using signal-triggered or randomly triggered counting gates. Analysis algorithms were developed for both approaches to determine singles (S), doubles (D) and triples (7) rates from the measured sample. Currently the most commonly implemented technique to collect neutron coincidence data utilizes shift register based electronics. Shift register uses signal-triggered counting gates to generate foreground multiplicity distribution of correlated+accidental events and a random gate (opened after a predefined long delay following the signal trigger) to generate background multiplicity distribution of accidental events. Modern shift registers include fast accidental option to sample data with a fixed clock frequency. This way a set of overlapping gates is used to generate background multiplicity distributions in order to improve the measurement precision. In parallel to shift register approach the Feynman variance technique is frequently used, which utilizes set of consecutive non-overlapping gates. In general, different user communities (e.g. safeguards, nuclear material accountancy, emergency response) have used only one of the two analysis methods for the nuclear material assay. The aim of this study is to provide a systematic comparison of the precision of the measured S, D, T rates and {sup 240}Pu effective mass obtained using the above mentioned pulse train sampling techniques. In order to perform this task, a LANL developed list mode based data acquisition system is used, where the entire pulse train is recorded and subsequently analyzed. The list mode acquisition brings an essential advantage for this type of comparison, since the very same pulse train can be analyzed using signal-triggered as well as randomly triggered counting gates. The aim of this study is not only to compare the precision of signal-triggered versus random triggered sampling techniques, but also to investigate the influence of fast accidental sampling on the precision of signal-triggered results. In addition the different random sampling techniques used in safeguards are investigated. For this purpose we implement two types of random sampling - non-overlapping gates (Feynrnan approach) and periodic overlapping gates (fast accidentals). In the following sections the equations utilized in the pulse train analysis are described, experimental setup and measurement techniques are discussed and finally the results are summarized and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗