Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Quarterly Research Performance Progress Report

The goal of this project is to develop a high temperature, high-pressure well integrity evaluation device that can operate in enhanced geothermal system (EGS) boreholes without active cooling or substantial mitigation of borehole conditions. The product must provide consistent high resolution data regarding the efficacy of wellbore casing and cement for long-term operation. This project aims to deliver a ruggedized tool that can withstand a corrosive geothermal environment with pressure ranges up to 15,000 psi and temperatures up to 250°C for a 24-hour operating period.

15 GEOTHERMAL ENERGY↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves the resistance measurement of a thin film of niobium. During coating, the change in resistance reflects the conversion of the film to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the thickness, allowing for increased precision in future depositions.

Howard, K. [Unlisted] (ORCID:0000000325613308)↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves a four-point resistance measurement of a thin film of niobium, inside the coating region. During coating, the change in resistance reflects the conversion of the film from Nb to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the Nb3Sn film thickness, allowing for increased precision in future depositions for cavity applications.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Non-Nuclear Test Facility Development to Support Verification and Validation Needs

This study focuses on developing a non-nuclear test facility to help meet the verification and validation (V&V) requirements of a water-cooled small modular reactor (SMR) system. The scaling analysis necessary for reactor system experimentation and assessment model V&V considers various reactor system accident scenarios such as main steam line break (MSLB), steam generator tube rupture (SGTR), and containment condensation and heat transfer. The goal is to identify key physics based phenomena of interest (POI), specific figures of merit (FOMs), and the state of knowledge (SOK) by employing phenomena identification and ranking table (PIRT) studies. Important physics phenomena such as heat transfer, fluid dynamics, structural integrity, and material selection must be addressed when scaling a thermal-hydraulics system. Alongside these considerations, modifications to the facility may be needed to align the scaled system with the available footprint (height and space) of the facility. These modifications may include infrastructure upgrades, changes to the piping layout, implementation of safety measures, and installation of new instrumentation and control systems. The test facility aims to provide a scaled-down version of prototypic facilities for comprehensive V&V activities by overcoming these challenges and making the necessary modifications. This approach minimizes scaling distortion, simulates prototypic plant conditions, and accurately models accident event progressions. Thus, the facility will be capable of adequately modeling a scaled SMR system to support the design, development and licensing needs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Lateral Alignment for Cooling Airflow during Heavy-Truck Platooning

A truck platooning system was tested using two heavy-duty tractor-trailer trucks on a closed test track to investigate the thermal control/heat rejection system sensitivity to intentional lateral offsets over a range of intervehicle spacings. Previous studies have shown the following vehicle can experience elevated temperatures and reduced airflow through the cooling package as a result of close-formation platooning. Four anemometers positioned across the grille of the following trucks as well as aligned and multiple offset positions are used to evaluate the sensitivity of the impact. Straight sections of the track are isolated for the most accurate airflow impact measurements and to be most representative of on-highway driving. An intentional lateral offset in truck platooning is considered as a controls approach to mitigate reduced cooling efficacy at close following scenarios where the highest platoon savings are achieved. The truck platooning system was tested at four gap distances from 9 to 23 meters and the following truck was either aligned with the lead or offset with a 25% width (0.65 m) or 50% width (1.3 m) lateral distance. The experimental results clearly show that offset driving is effective at bringing cooling airflow from 56% with an aligned platoon back up to 75%-80% with minimal impact to fuel savings. In addition, the offset driving can also reduce the trailing truck’s engine coolant temperature by 2°C and the corresponding underhood temperature rise by 10°C. The test outcomes indicate a plausible controls strategy to mitigate reduced cooling flow during hot-weather truck platooning while still enabling the highest-energy-saving, close-following scenarios.

27 ARPA - Advanced Research Projects Agency-Energy↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combinatorial measurement of critical cooling rates in aluminum-base metallic glass forming alloys

Direct measurement of critical cooling rates has been challenging and only determined for a minute fraction of the reported metallic glass forming alloys. Here, we report a method that directly measures critical cooling rate of thin film metallic glass forming alloys in a combinatorial fashion. Based on a universal heating architecture using indirect laser heating and a microstructure analysis this method offers itself as a rapid screening technique to quantify glass forming ability. We use this method to identify glass forming alloys and study the composition effect on the critical cooling rate in the Al–Ni–Ge system where we identified Al 51 Ge 35 Ni 14 as the best glass forming composition with a critical cooling rate of 10 4 K/s.

36 MATERIALS SCIENCE↗

Cryogenic control system operational experience at SNS

Abstract The helium cryogenic system at Spallation Neutron Source (SNS) provides cooling to 81 superconducting radio frequency cavities. To support the operation of the cryogenic facility, a highly reliable control system consisting of software, hardware, and Human Machine Interface (HMI) has been developed and improved during the first fifteen years of operation. Integrating the cryogenic control system with other subsystems of the SNS complex is an important aspect to the success of the operation. The operating experience, lessons learned and recommendations to consider for future facilities will be detailed in this paper.

Howell, M. (ORCID:0000000310360707)↗

Analysis of AP1000 Small-Break Loss-of-Coolant Accident Using Reactor Transient Simulator

The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity analysis of design parameters in RowWise borehole layout for ground heat exchangers

Ground source heat pump systems offer a promising pathway toward energy-efficient building heating and cooling. The performance and cost-effectiveness of these systems heavily depend on the design of the ground heat exchanger (GHE), particularly the spatial placement of boreholes used in large commercial buildings. Among various borefield layout strategies, the RowWise approach generates and optimizes borehole configurations within irregular polygonal land boundaries, providing land-use efficiency and installation flexibility. While multiple geometric design parameters constrain the RowWise layout, their influence on the system thermal performance and total drilling requirements remains unclear. Thus, this study presents a sensitivity analysis of key design parameters influencing the RowWise layout of vertical borehole GHEs, including the perimeter spacing ratio, borehole spacing, borehole field rotation angle, and borehole length. GHEDesigner and Ray Tune are employed to generate and assess different RowWise configurations. A series of parametric simulations was conducted to quantify the impact of each parameter on geometric distribution, economic cost, and computational speed. The results provide critical insights into the sensitivity and relative importance of different design parameters of RowWise method, offering practical guidance for designers aiming to optimize GHE layouts by balancing thermal efficiency, land constraints, and economic feasibility.

Xu, Dikai [Purdue University]↗

Sensitivity of surface temperature to oceanic forcing via q-Flux Green’s function experiments. Part III: asymmetric response to warming and cooling

Climate response is often assumed to be linear in climate sensitivity studies. However, by examining the surface temperature (TS) response to pairs of oceanic forcings of equal amplitude but opposite sign in a large set of local q-flux perturbation experiments with CAM5 coupled to a slab, we find strong asymmetry in TS responses to the heating and cooling forcings, indicating a strong nonlinearity intrinsic to the climate system examined. Regardless of where the symmetric forcing is placed, the cooling response to the negative forcing always exceeds the warming to the positive forcing, implying an intrinsic inclination towards cooling of our current climate. Thus, the ongoing global warming induced by increasing greenhouse gases may have already been alleviated by the asymmetric component of the response. The common asymmetry in TS response peaks in high latitudes, especially along sea ice edges, with notable seasonal dependence. Decomposition into different radiative feedbacks through a radiative kernel indicates that the asymmetry in the TS response is realized largely through lapse rate and albedo feedbacks. Further process interference experiments disabling the seasonal cycle and/or sea ice reveal that the asymmetry originates ultimately from the presence of the sea ice component and is further amplified by the seasonal cycle. The fact that a pair of opposite tropical q-flux forcings can excite very similar asymmetric response as a pair placed at 55°S strongly suggests the asymmetric response is a manifestation of an internal mode of the climate model system.

Liu, Fukai↗

Investigation of experimental signatures of spin glass transition temperature

We present a series of temperature and field-dependent magnetization studies of large single-crystal spin glass samples, focusing on both field-cooled (FC) and zero-field-cooled (ZFC) magnetization studies, as well as ac susceptibility measurements. Using the above experimental techniques we aim to understand the nature of spin glass transition in presence of a field, a key factor in understanding the properties of these systems. Building on previous studies that have explored magnetic signatures indicative of spin glass transitions, our research employs a systematic approach to refine the identification of this transition temperature. Through static and dynamic measurements, we aim to shed light on the open issues regarding the key markers of spin glass transitions, enhancing our understanding of these complex systems.

36 MATERIALS SCIENCE↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗