Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A phase contrast imaging–interferometer system for detection of multiscale electron density fluctuations on DIII-D

Heterodyne interferometry and phase contrast imaging (PCI) are robust, mature techniques for measuring low-k and high-k electron density fluctuations, respectively. This work describes the first-ever implementation of a combined PCI–interferometer. The combined system uses a single 10.6 μm probe beam, two interference schemes, and two detectors to measure electron density fluctuations at large spatiotemporal bandwidth (10 kHz <f < 5 MHz and 0 cm{sup -1} ≤k ≤ 20 cm{sup -1}), allowing simultaneous measurement of ion- and electron-scale instabilities. Further, correlating our interferometer’s measurements with those from DIII-D’s pre-existing, toroidally separated interferometer allows core-localized, low-n MHD studies that may otherwise be inaccessible via external magnetic measurements. The combined diagnostic’s small port requirements and minimal access restrictions make it well-suited to the harsh neutron environments and limited port space expected in next-step devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrally-broadened multimode lasing based on structurally graded InGaN nanocolumn photonic crystals suitable for reduction of speckle contrast

Bottom-up grown structurally graded InGaN-based nanocolumn photonic crystals, in which nanocolumns were arranged in triangular lattice and the nanocolumn diameter changed one-dimensionally from 93 to 213 nm with a fixed lattice constant of 250 nm, were fabricated. The spatial distribution of the diameter resulted in random-laser-like operation under optical excitation. A broad multi-wavelength lasing spectrum with more than 10 peaks was obtained with a full width at half maximum of 27 nm at 505 nm wavelength as well as lowering of the polarization degree, which is expected to be suitable for speckle contrast reduction in laser projection display applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The phase-contrast imaging instrument at the matter in extreme conditions endstation at LCLS

Here, we describe the phase-contrast imaging instrument at the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source. The instrument can image phenomena with a spatial resolution of a few hundreds of nanometers and at the same time reveal the atomic structure through X-ray diffraction, with a temporal resolution better than 100 fs. It was specifically designed for studies relevant to high-energy-density science and can monitor, e.g., shock fronts, phase transitions, or void collapses. This versatile instrument was commissioned last year and is now available to the MEC user community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photothermoelastic contrast in nanoscale infrared spectroscopy

The contrast formation mechanism in nanoscale Infrared (IR) Spectroscopy is analyzed. The temperature distribution and elastic displacement across the illuminated T-shape boundary between two materials with different IR-radiation absorption coefficients and thermo-physical and elastic properties located on a rigid substrate are calculated self-consistently for different frequencies f ~ (1 kHz–1 MHz) of IR-radiation modulation (fully coupled problem). Analytical expressions for the temperature and displacement profiles across the “thermo-elastic step” are derived in the decoupling approximation for f = 0 (“static limit”), and conditions for approximation validity at low frequencies of IR-modulation are established. The step height was found to be thickness-independent for thick layers and proportional to the square of the thickness for very thin films. The theoretical results will be of potential interest for applications in the scanning thermo-ionic and thermal infrared microscopies for relatively long sample thermalization times and possibly for photothermal induced resonance microscopy using optomechanical probes.

36 MATERIALS SCIENCE↗

Simultaneous 8.2 keV phase-contrast imaging and 24.6 keV X-ray diffraction from shock-compressed matter at the LCLS

In this paper, we demonstrate simultaneous phase-contrast imaging (PCI) and X-ray diffraction from shock compressed matter at the Matter in Extreme Conditions endstation, at the Linac Coherent Light Source (LCLS). We utilize the chromaticity from compound refractive X-ray lenses to focus the 24.6 keV 3rd order undulator harmonic of the LCLS to a spot size of 5 μm on target to perform X-ray diffraction. Simultaneous PCI from the 8.2 keV fundamental X-ray beam is used to visualize and measure the transient properties of the shock wave over a 500 μm field of view. Furthermore, we demonstrate the ability to extend the reciprocal space measurements by 5 Å –1 , relative to the fundamental X-ray energy, by utilizing X-ray diffraction from the 3rd harmonic of the LCLS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 μm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm -1 < |k R | ≤ 25 cm -1 ) fluctuations with sensitivity 3×10 13 m -2 /$\sqrt{kHz}$, while the interferometer simultaneously measures low-k (|k R | < 5 cm -1 ) fluctuations with sensitivity 3×10 14 m -2 /$\sqrt{kHz}$. The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ~ T i regime. Lastly, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of the Wendelstein 7-X phase contrast imaging diagnostic

A phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. This diagnostic, funded by the U.S. Department of Energy through the Office of Fusion Energy Sciences, is a collaboration between the Max Planck Institute for Plasmaphysics, MIT, and SUNY Cortland. The primary motivation for the development of the PCI diagnostic is measurement of turbulent fluctuations, such as the ion temperature gradient, electron temperature gradient, and the trapped electron mode instabilities. Understanding how the magnetic geometry and other externally controllable parameters, such as the fueling method and heating scheme, modify the amplitude and spectrum of turbulence is important for finding operational scenarios that can lead to improved performance at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, as may arise from Alfvén eigenmodes or other MHD activity, for example. The PCI method creates an image of line-integrated variations in the index of refraction. For a plasma, the image created is proportional to the line-integral of electron density fluctuations. Here, this paper provides an overview of some key features of the hardware and the optical system and presents two examples of recent measurements from the W7-X OP1.2a experimental campaign.

47 OTHER INSTRUMENTATION↗

Direct observation of dislocation structure evolution in SRF cavity niobium using electron channeling contrast imaging

Two major goals of superconducting radio frequency cavity research and development are achieving higher accelerating gradient and gaining the highest quality factor, a measure of efficiency. However, the consistent improvement of these performance metrics is restricted by many factors, one of which is microstructural defects, such as dislocation substructures within the material. In this work, dislocation evolution is compared in four samples extracted from a 2.8 mm thick large-grain niobium slice, with tensile axes chosen to generate specific dislocation structures during subsequent deformation. The four samples are (1) as-extracted, (2) extracted and annealed, (3) extracted and then deformed to 40% tensile strain, and (4) extracted, annealed at 800 °C 2 h, and then deformed to 40% strain. Electron channeling contrast imaging was performed on all samples to characterize initial dislocation density and dislocation structure evolution due to annealing and deformation, and related to the mechanical behavior observed in stress-strain curves. A fundamental understanding of dislocation evolution in niobium is necessary to develop computational models to simulate cavity forming, which could enable new processing methods for cavity fabrication to be identified that could lead to improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluorescence intensity correlation imaging with high spatial resolution and elemental contrast using intense x-ray pulses

We theoretically investigate the fluorescence intensity correlation (FIC) of Ar clusters and Mo-doped iron oxide nanoparticles subjected to intense, femtosecond, and sub-femtosecond x-ray free-electron laser pulses for high-resolution and elemental contrast imaging. We present the FIC of Kα and Kαh emission in Ar clusters and discuss the impact of sample damage on retrieving high-resolution structural information and compare the obtained structural information with those from the coherent diffractive imaging (CDI) approach. We found that, while sub-femtosecond pulses will substantially benefit the CDI approach, few-femtosecond pulses may be sufficient for achieving high-resolution information with the FIC. Furthermore, we show that the fluorescence intensity correlation computed from the fluorescence of the Mo atoms in Mo-doped iron oxide nanoparticles can be used to image dopant distributions in the nonresonant regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High spatial resolution and contrast radiography of hydrodynamic instabilities at the National Ignition Facility

In this work, we are developing techniques for studying the Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high-energy-densities at the National Ignition Facility (NIF). In particular, through the improvement of experimental imaging quality, we are progressing toward the study of the turbulent regime of the mixing regions in capsule implosion experiments for inertial confinement fusion, which requires few micrometers resolution. Using 60 NIF beams, a solid shock tube is driven launching a shock wave that crosses the interface between a dense and a light material pre-machined in the target to obtain sinusoidal ripples, which results in RM and RT instabilities that are imaged using the NIF Crystal Backlighter Imager. High-quality images were obtained with a mean resolution of 7 μm and improved contrast. While the obtained resolution does not allow the observation of the smallest scale of the “turbulent” energy spectrum, the generated image encompasses 63% of the total flow energy, a 50% improvement over previous studies, which is observed for the first time a roll-up feature in a high energy density-type RT experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation protocol for revealing magnonic contrast in TR-STXM measurements

We present a statistically motivated method to extract magnonic contrast from time-resolved scanning transmission x-ray microscopy (TR-STXM) measurements. TR-STXM is an element-specific method for resolving spin-dynamics in space and time. It offers nanometer spatial resolution and picosecond temporal resolution. The presented method makes it possible to obtain phase and amplitude profiles of spin-waves from STXM measurements. Furthermore, it allows for a rigorous transformation to reciprocal magnon k⃗-space, revealing k⃗-dependent magnon properties such as the magnon dispersion in three dimensions and for all directions of the magnetic anisotropy. We demonstrate our method using X-band ferromagnetic resonance on a micrometer-sized permalloy assembly.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contrast optimization of Fresnel zone plate imaging

Fresnel zone plates (FZPs) are circular diffractive elements that operate as a lens for x-rays. They have gained interest in the field of laser-plasma physics due to their ability to achieve higher spatial resolution than pinholes. Their design and implementation are complicated by the fact that a significant amount of the x-rays passing through the FZP will not diffract (zeroth order) and present a background to the measurement. This background can be large and inhomogeneous depending on the geometric setup of the experiment. Furthermore, we present calculations of the diffracted (first order) and un-diffracted (zeroth order) flux profiles, which makes it possible to optimize the contrast between the first order imaging rays and the zeroth order background. Calculations for the implementation of a central block in the FZP, designed to block the zeroth from the entire field of view, are also presented.

47 OTHER INSTRUMENTATION↗

Quantitative x ray phase contrast imaging of oblique shock wave–interface interactions

Oblique shock wave–interface interactions of gases and liquids have been extensively studied in shock tubes using optical methods to measure equation-of-state (EOS) parameters. However, this is difficult with solids due to their opaqueness to visible light. X ray phase contrast imaging (XPCI) has the penetrative strength to probe solids while still being sensitive to mass density and enhancing the visibility of material boundaries. We investigate the accuracy and repeatability of measuring the mean value of the average mass density (areal density divided by thickness) over region S (B S ) and flow deflection angle (θ) from XPCI images of a sample. To that end, a Hough transform-based method for measuring θ is developed. To measure B S , the XPCI image intensity probability density function (PDF) is modeled accounting for the spatial distribution of x ray energy, scintillator response, and pulse-to-pulse variation in the x ray intensity. In addition, a Monte Carlo-based algorithm for computing the B S PDF is developed. Both methods are validated on an impact-generated oblique shock wave interacting at a solid polymer-to-polymer interface. Furthermore this is accomplished through a comparison to hydrodynamic simulations using well-established EOS. Under the modeling framework for the XPCI image intensity, B S is computed with an accuracy of < 0.1% and precision of 3%–5%, while θ has an uncertainty of 0.2°, respectively. This shows that the XPCI-based model that is developed here could be an invaluable tool for high-fidelity testing of hydrodynamic models in shock polar configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Localized phase contrast imaging at the Wendelstein 7-X stellarator

In its basic form, phase contrast imaging (PCI) provides line-integrated measurements of electron density fluctuations in plasmas. As turbulent fluctuations in magnetically confined plasmas have wave vectors almost perpendicular to the background magnetic field, the signals scattered by fluctuations from different parts of the PCI line-of-sight (LoS) are spatially separated in focal planes of the plasma. This allows localized PCI measurements by placing a mask in such a plane, to only permit signals from specific parts of the LoS to reach the PCI detectors. The present paper describes modeling and design of localization masks for the PCI system at the Wendelstein 7-X (W7-X) stellarator as well as the first results obtained using the masks in the recent long-pulse W7-X experimental campaign. During this project, we have extended the theory describing the mask response within the Fraunhofer diffraction model. As a novel development, we show from first principles that the mask response is determined by the fraction of power of the scattered beam spots that passes the mask. These insights have been used to select the W7-X mask design, consisting of a circular cutout, allowing the unscattered beam spot to pass the mask, with wedges covering a fixed angular range outside the central cutout. In the recent W7-X experimental campaign, the masks have verified the location of the main turbulence features observed by the PCI system and provided new information about the location of short-wavelength magnetohydrodynamic modes.

Physics↗

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology↗

Analysis of the process of visualisation of transparent objects using the phase-contrast method with a photothermal Zernike cell

Basic characteristics of the process of visualisation of transparent objects using the phase-contrast method with a photothermal Zernike cell are analysed and evaluated. It is shown that, in spite of nonlocality of the process, visualisation is accomplished with the resolution close to the diffraction limit. The results of the visualisation process analysis in the scheme with a photothermal sell are compared with those obtained in a similar scheme with a Zernike cell based on the local Kerr nonlinearity. (optical image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

62 RADIOLOGY AND NUCLEAR MEDICINE↗