Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Hierarchical models and iterative optimization of hybrid systems

A class of hybrid control systems on the base of two-level discrete-continuous model is considered. The concept of this model was proposed and developed in preceding works as a concretization of the general multi-step system with related optimality conditions. A new iterative optimization procedure for such systems is developed on the base of localization of the global optimality conditions via contraction the control set.

97 MATHEMATICS AND COMPUTING↗

SAVANNAH RIVER SITE ENVIRONMENTAL REPORT FOR 2010

This report was prepared in accordance with U.S. Department of Energy (DOE) Order 231.1A, 'Environment, Safety and Health Reporting,' to present summary environmental data for the purpose of: (a) characterizing site's environmental management performance; (b) summarizing environmental occurrences and responses reported during the calendar year; (c) describing compliance status with respect to environmental standards and requirements; and (d) highlighting significant site programs and efforts. This report is the principal document that demonstrates compliance with the requirements of DOE Order 5400.5, 'Radiation Protection of the Public and the Environment,' and is a key component of DOE's effort to keep the public informed of environmental conditions at Savannah River Site (SRS). SRS has four primary missions: (1) Environmental Management - Cleaning up the legacy of the Cold War efforts and preparing decommissioned facilities and areas for long-term stewardship; (2) Nuclear Weapons Stockpile Support - Meeting the needs of the U.S. nuclear weapons stockpile through the tritium programs of the National Nuclear Security Administration (NNSA); (3) Nuclear Nonproliferation Support - Meeting the needs of the NNSA's nuclear nonproliferation programs by safely storing and dispositioning excess special nuclear materials; and (4) Research and Development - Supporting the application of science by the Savannah River National Laboratory (SRNL) to meet the needs of SRS, the DOE complex, and other federal agencies During 2010, SRS worked to fulfill these missions and position the site for future operations. SRS continued to work with the South Carolina Department of Health and Environmental Control (SCDHEC), the Environmental Protection Agency (EPA), and the Nuclear Regulatory Commission to find and implement solutions and schedules for waste management and disposition. As part of its mission to clean up the Cold War legacy, SRS will continue to address the highest-risk waste management issues by safely storing and preparing liquid waste and nuclear materials for disposition, and by safely stabilizing any tank waste residues that remain on site.

54 ENVIRONMENTAL SCIENCES↗

TIME-VARYING FLAME IONIZATION SENSING APPLIED TO NATURAL GAS AND PROPANE BLENDS IN A PRESSURIZED LEAN PREMIXED (LPM) COMBUSTOR

In-situ monitoring of combustion phenomena is a critical need for optimal operation and control of advanced gas turbine combustion systems. The concept described in this paper is based on naturally occurring flame ionization processes that accompany the combustion of hydrocarbon fuels. Previous work has shown that flame ionization techniques may be applied to detect flashback, lean blowout, and some aspects of thermo-acoustic combustion instabilities. Previous work has focused on application of DC electric fields. By application of time-varying electric fields, significant improvements to sensor capabilities have been observed. These data have been collected in a lean premixed combustion test rig operating at 0.51-0.76 MPa (5-7.5 atm) with air preheated to 588 K (600°F). Five percent of the total fuel flow is injected through the centerbody tip as a diffusion pilot. The fuel composition is varied independently by blending approximately 5% (volume) propane with the pipeline natural gas. The reference velocity through the premixing annulus is kept constant for all conditions at a nominal value of 70 m/s. The fuel-air equivalence ratio is varied independently from 0.46 – 0.58. Relative to the DC field version, the time-varying combustion control and diagnostic sensor (TV-CCADS) shows a significant improvement in the correlation between the measured flame ionization current and local fuel-air equivalence ratio. In testing with different fuel compositions, the triangle wave data show the most distinct change in flame ionization current in response to an increase in propane content. Continued development of this sensor technology will improve the capability to control advanced gas turbine combustion systems, and help address issues associated with variations in fuel supplies.

03 NATURAL GAS↗

Initial Studies on Actionable Control for Improving Small Signal Stability in Interconnected Power Systems

Power consumption and demand continues to grow around the world. As the electric power grid continues to be put under more stress, the conditions of instability are more likely to occur. One cause of such instabilities is intearea oscillations, such as the oscillation that resulted in the August 10, 1996 blackout of the WECC. This paper explores different potential operations of different devices on the power system to improve the damping of these interarea oscillations using two different simulation models

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sliding Mode Network Perimeter Control

Urban traffic congestion is a chronic problem faced by many cities in the US and worldwide. It results in inefficient infrastructure use as well as increased vehicle fuel consumption and emission levels. Congestion is intertwined with delay, as road users waste precious hours on the road, which in turn reduces productivity. Researchers have developed, and continue to design, tools and systems to alleviate this problem. Network perimeter control is one such tool that has been studied extensively. It attempts to control the flow of vehicles entering a protected area to ensure that the congested regime predetermined by the Network Fundamental Diagram (NFD) is not reached. In this paper, a method derived from sliding mode control theory is presented. Its main advantages over proportional-integral controllers include (1) minimal tuning, (2) no linearization of the governing equations, (3) no assumptions with regard to the shape of the NFD, and (4) ability to handle various demand profiles without the need to retune the controller. A sliding mode controller was implemented and tested on a congested grid network. The results show that the proposed controller produces network-wide delay savings and disperses congestion effectively.

42 ENGINEERING↗

Active Gate Current Control for Non-Insulating-Gate WBG Devices

This paper proposes an Active Gate Current Control (AGCC) strategy for non-insulating gate WBG devices, for example, gallium nitride gate-injection-transistor (GaN-GIT) and silicon carbide super junction transistor (SiC-SJT). It provides a tool for power converter designers to further improve the converter efficiency and to extend the life time of those higher cost power transistors. By continuously adjusting the device gate current, the proposed AGCC strategy can control the device switching speed, switching loss, conduction loss and gate loss together to achieve operation goals, including lower semiconductor loss, lower thermal stress, lower EMI spectrum, or smaller voltage overshoot across the full range

dv/dt↗

Concepts for Autonomous Operation of Microreactors

Microreactor concepts have seen increasing interest in recent years given their potential use for meeting energy needs in remote and grid-isolated communities. Given the small power outputs of microreactors and the potential for remote siting, there is a need to reduce operational staffing levels to improve their economic viability. A key enabling technology for this purpose is autonomous control that enables autonomous operation of microreactors. While several options for autonomous control exist, the level of human operator involvement in operational decision making needs to be defined as part of the system design process. Once this separation of function is achieved, several options exist for autonomous control ranging from simple automation of some procedures to fully autonomous operational mode decision making and execution.A critical aspect of autonomous decision making is the ability to have as complete an awareness of the system state as possible. In addition to data on temperature, pressure, flow, and neutron flux, measurements of the condition of important components will be necessary. This type of information will allow the autonomous control system to adapt its decision making to any changing conditions within the reactor, thereby not compromising safety while continuing to operate for as long as possible. Several technical advances are needed before widespread use of autonomous control in microreactors. These include sensor and instrumentation technologies that are capable of long term, unattended operation in harsh environments, technologies for inferring the state of the microreactor system or subsystems in an automated fashion, algorithms for predictive decision making that account for the assessed condition of the microreactor subsystems as well as the potential impact on those components of any operational decision, and actuators and control system hardware that are also long-lived in a harsh environment. In addition, given the need to remotely monitor the operations, cybersecurity requirements will likely need to be imposed to ensure secure operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Well-to-wheels greenhouse gas and air pollutant emissions from battery electric vehicles in China

Electric vehicles (EVs) play a crucial role in addressing climate change and urban air quality concerns. China has emerged as the global largest EV market with 1.2 million EVs sold in 2018. This study established a novel life cycle energy use and emission inventory collecting up-to-date data including the electricity generation mix, emission controls in the power and industrial sectors, and the energy use in the fuel transport to estimate the well-to-wheels (WTW) greenhouse gas (GHG), and air pollutant emissions for battery electric vehicles (BEVs) and gasoline passenger vehicles in China. The results show that an average BEV has 35% lower WTW GHG emissions than an average gasoline car. BEVs reduce volatile organic compounds (VOCs) and nitrogen oxides (NOX) emissions by 98% and 34%, respectively, but have comparable or slightly higher primary fine particulate matter (PM2.5) and sulfur dioxide (SO2) emissions. Compact and small-size vehicles generally have lower GHG and air pollutant emissions than mid- and large-size vehicles. Class A vehicles contribute the most in the absolute amount of GHG and air pollutant emissions and therefore have the biggest potential for emission reduction. Our results suggest that global policymakers should continue to promote the transition to clean power sources, emission control, and fuel economy regulations, which are critical to enhancing emission mitigation benefits of BEVs. We also suggest EV development strategies should be formulated targeting vehicle class with the biggest emission mitigation potentials.

Air pollutant emissions↗

Inverse Calculation of Burden Distribution Matrix Using B-spline Model Based PDF control in Blast Furnace Burden Charging Process

The inverse calculation of burden distribution matrix (BDM) is one of the most important challenges in the blast furnace operation in iron-making processes. In general, blast furnace consumes 65% of the total energy for the whole steel-making. Focusing on this practical challenge, this article proposes a new burden distribution spatial model in calculating burden charging process, and develops a B-spline approximation-based probability density function (PDF) control algorithm to assign the expected thickness distribution of burden layer and, thus, develops a new method for the required inverse calculation of BDM. First, a novel method for the thickness distribution of burden layer is given using B-spline model to produce an expected distribution shape subjected to a desired tracking within a specific spatial constraint. Then, according to the coexistence of continuous and bounded discrete variables in BDM, a novel hybrid optimization control method by combining integer programming and PDF tracking is further established for the effective inverse calculation of BDM. Finally, the proposed PDF-based iterative inverse calculation of BDM using B-spline models are tested using various data from industrial examples. Furthermore, the simulation results show that the proposed method is well suited to solve the BDM inverse calculation problem in practice.

42 ENGINEERING↗

Final Results of Local-Regional Control and Late Toxicity of RTOG 9003: A Randomized Trial of Altered Fractionation Radiation for Locally Advanced Head and Neck Cancer

Purpose: To test whether altered radiation fractionation schemes (hyperfractionation [HFX], accelerated fractionation, continuous [AFX-C], and accelerated fractionation with split [AFX-S]) improved local-regional control (LRC) rates for patients with squamous cell cancers (SCC) of the head and neck when compared with standard fractionation (SFX) of 70 Gy. Methods and Materials: Patients with stage III or IV (or stage II base of tongue) SCC (n=1076) were randomized to 4 treatment arms: (1) SFX, 70 Gy/35 daily fractions/7 weeks; (2) HFX, 81.6 Gy/68 twice-daily fractions/7 weeks; (3) AFX-S, 67.2 Gy/42 fractions/6 weeks with a 2-week rest after 38.4 Gy; and (4) AFX-C, 72 Gy/42 fractions/6 weeks. The 3 experimental arms were to be compared with SFX. Results: With patients censored for LRC at 5 years, only the comparison of HFX with SFX was significantly different: HFX, hazard ratio (HR) 0.79 (95% confidence interval 0.62-1.00), P=.05; AFX-C, 0.82 (95% confidence interval 0.65-1.05), P=.11. With patients censored at 5 years, HFX improved overall survival (HR 0.81, P=.05). Prevalence of any grade 3, 4, or 5 toxicity at 5 years; any feeding tube use after 180 days; or feeding tube use at 1 year did not differ significantly when the experimental arms were compared with SFX. When 7-week treatments were compared with 6-week treatments, accelerated fractionation appeared to increase grade 3, 4 or 5 toxicity at 5 years (P=.06). When the worst toxicity per patient was considered by treatment only, the AFX-C arm seemed to trend worse than the SFX arm when grade 0-2 was compared with grade 3-5 toxicity (P=.09). Conclusions: At 5 years, only HFX improved LRC and overall survival for patients with locally advanced SCC without increasing late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuous Fly-Through High-Temperature Synthesis of Nanocatalysts

Conventional thermal treatment system, such as muffle and tube furnaces, typically feature low ramping and cooling rates, which lead to steep thermal gradients during bulk material synthesis that generate inefficient, non-uniform reaction conditions and result in nanoparticle aggregation. Herein, we demonstrate a continuous fly-through material synthesis approach using a novel high-temperature reactor design based on the emerging thermal-shock technology. By facing two sheets of carbon paper with a small distance apart (1–3 mm), we are able to generate uniform, ultra-high temperatures that can reach up to 3200 K within 50 ms by simply applying a voltage of 15 V. We can control this high-temperature to enable ultrafast chemical reactions by continuously feeding raw materials through the device from one end to the other, allowing the final products to be rapidly collected. As a proof-of-concept demonstration, we synthesized Pt nanocatalysts ~4 nm in size anchored to carbon black via this fly-through high-temperature reactor at ~1400 K. Furthermore, we find these supported Pt nanoparticles feature excellent electrocatalytic activities toward methanol oxidation reaction. Compared to existing heating methods, this continuous fly-through high temperature reactor offers a new and highly efficient platform for the synthesis of nanomaterials at high temperatures.

Qiao, Yun↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Building Energy Simulation Using EnergyPlus and the Building Controls Test Bed

Most commercial buildings do not perform as well in practice as intended by the design and their performances often deteriorate over time. Reasons include faulty construction, malfunctioning equipment, incorrectly configured control systems and inappropriate operating procedures (Haves et al., 2001, Lee et al., 2007). To address this problem, the paper presents a simulation-based whole building performance monitoring tool that allows a comparison of building actual performance and expected performance in real time. The tool continuously acquires relevant building model input variables from existing Energy Management and Control System (EMCS). It then reports expected energy consumption as simulated of EnergyPlus. The Building Control Virtual Test Bed (BCVTB) is used as the software platform to provide data linkage between the EMCS, an EnergyPlus model, and a database. This paper describes the integrated real-time simulation environment. A proof-of-concept demonstration is also presented in the paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Occupancy Based Demand Controlled Ventilation in Residences

Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as 'dose') as the metric to evaluate the effectiveness and air quality implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant generation. The pollutant generation had two components: a background rate associated with the building materials and furnishings and a second component related to occupants. The demand controlled ventilation system operated at a low airflow rate when the residence was unoccupied and at a high airflow rate when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we can optimize the demand controlled airflow rates to reduce the quantity of air used for ventilation without introducing problematic acute conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IR spectroscopic quantification of small molecule transport and desorption phenomena in polymers

The application, continued performance, and degradation behavior of polymers often depends on their interaction with small organic or gaseous volatiles. Understanding the underlying permeation and diffusion properties of materials is crucial for predicting their barrier properties (permeant flux), drying behavior, solvent loss or tendency to trap small molecules, as well as their interaction with materials in the vicinity due to off-gassing phenomena, perhaps leading to compatibility concerns. Further, the diffusion of low Mw organics is also important for mechanistic aspects of degradation processes. Based on our need for improved characterization methods, a FTIR-based spectroscopic gas/volatile quantification setup was designed and evaluated for determination of the diffusion, desorption and transport behavior of small IR-active molecules in polymers. At the core of the method, a modified, commercially available IR transmission gas cell monitors time-dependent gas concentration. Appropriate experimental conditions, e.g. desorption or permeation under continuous flow or static gas conditions, are achieved using easily adaptable external components such as flow controllers and sample ampoules. This study presents overview approaches using the same IR detection methodology to determine diffusivity (desorption into a static gas environment, continuous gas flow, or intermittent desorption) and permeability (static and dynamic flow detection). Further, the challenges encountered for design and setup of IR gas quantification experiments, related to calibration and gas interaction, are presented. These methods establish desorption and permeation behavior of solvents (water and methanol), CO 2 off-gassing from foam, and offer simultaneous measurements of the permeation of several gases in a gas mixture (CO 2 , CO and CH 4 ) through polymer films such as epoxy and Kapton. They offer complementary guidance for material diagnostics and understanding of basic properties in sorption and transport behavior often of relevance to polymer degradation or materials reliability phenomena.

36 MATERIALS SCIENCE↗

On-demand generation of aqueous two-phase microdroplets with reversible phase transitions

Aqueous two-phase systems contained entirely within microdroplets enable a bottom-up approach to mimicking the dynamic microcompartmentation of biomaterial that naturally occurs within the cytoplasm of cells. Here, we demonstrate the on-demand generation of femtolitre aqueous two-phase droplets within a microfluidic oil channel. Gated pressure pulses were used to generate individual, stationary two-phase microdroplets with a well-defined time zero for carrying out controlled and sequential phase transformations over time. Reversible phase transitions between single-phase, two-phase, and core-shell microgel states were obtained via evaporation-induced dehydration and on-demand water rehydration. In contrast to other microfluidic aqueous two-phase droplets, which require continuous flows and high-frequency droplet formation, our system enables the controlled isolation and reversible transformation of a single microdroplet and is expected to be useful for future studies in dynamic microcompartmentation and affinity partitioning.

Boreyko, Jonathan B↗