Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The Nature of Insoluble Organic Matter in Sutter’s Mill and Murchison Carbonaceous Chondrites: Testing the Effect of X-ray Computed Tomography (XCT) and Exploring Parent Body Organic Molecular Evolution

This study analyzed samples of the Murchison and Sutter’s Mill carbonaceous chondrite meteorites in support of the future analysis of samples returned from the asteroid (10155) Bennu by the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer) mission. Focusing specifically on the insoluble organic matter (IOM), this study establishes that a total of 1.3 g of bulk sample from a single chondritic meteorite is sufficient to obtain a wide range of cosmochemical information, including light element analysis (H, C, and N), isotopic analysis (D/H, 13 C/ 12 C, and 15 N/ 14 N), and X-ray fluorescence spectroscopy for major elemental abundances. IOM isolated from the bulk meteorite samples was analyzed by light element and isotopic analysis as described above, 1 H and 13 C solid-state nuclear magnetic resonance spectroscopy, Raman spectroscopy, and complete noble gas analyses (abundances and isotopes). The samples studied included a pair from Murchison (CM2), one of which had been irradiated with high-energy X-rays in the course of computed tomographic imaging. No differences between the irradiated and non-irradiated Murchison samples were observed in the many different chemical and spectroscopic analyses, indicating that any X-ray–derived sample damage is below levels of detection. Elemental, isotopic, and molecular spectroscopic data derived from IOM isolated from the Sutter’s Mill sample reveals evidence that this meteorite falls into the class of heated CM chondrites.

planetary science↗

Particle-Tracking Proton Computed Tomography—Data Acquisition, Preprocessing, and Preconditioning

Proton CT (pCT) is a promising new imaging technique that can reconstruct relative stopping power (RSP) more accurately than x-ray CT in each cubic millimeter voxel of the patient. This, in turn, will result in better proton range accuracy and, therefore, smaller planned tumor volumes (PTV). The hardware description and some reconstructed images have previously been reported. In a series of two contributions, we focus on presenting the software algorithms that convert pCT detector data to the final reconstructed pCT images for application in proton treatment planning. There were several options on how to accomplish this, and we will describe our solutions at each stage of the data processing chain. In the first paper of this series, we present the data acquisition with the pCT tracking and energy-range detectors and how the data are preprocessed, including the conversion to the well-formatted track information from tracking data and water-equivalent path length from the data of a calibrated multi-stage energy-range detector. These preprocessed data are then used for the initial image formation with an FDK cone-beam CT algorithm. The output of data acquisition, preprocessing, and FDK reconstruction is presented along with illustrative imaging results for two phantoms, including a pediatric head phantom. The second paper in this series will demonstrate the use of iterative solvers in conjunction with the superiorization methodology to further improve the images resulting from the upfront FDK image reconstruction and the implementation of these algorithms on a hybrid CPU/GPU computer cluster.

42 ENGINEERING↗

Electronic stopping power calculation for water under the Lindhard formalism for application in proton computed tomography

Because of the behavior that charged particles have when they interact with biological material, proton therapy is shaping the future of radiation therapy in cancer treatment. The planning of radiation therapy is made up of several stages. The first one is the diagnostic image, in which you have an idea of the density, size and type of tumor being treated; to understand this it is important to know how the particles beam interacts with the tissue. In this work, by using de Lindhard formalism and the Y.R. Waghmare model for the charge distribution of the proton, the electronic stopping power (SP) for a proton beam interacting with a liquid water target in the range of proton energies 10{sup 1} eV - 10{sup 10} eV taking into account all the charge states is calculated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of HLW Glass Melting Rate Between Frit and Glass Forming Chemicals Using X-Ray Computed Tomography

Efforts are being made to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies, as well as requirements for processing, regulatory compliance, and product quality. To achieve these goals, the Department of Energy – Office of River Protection (DOE-ORP) has requested that the Savannah River National Laboratory (SRNL) support the advancement of glass formulations and process control strategies in various key technical areas, which include melting rate studies. Numerous parameters influence cold cap melting and it is important to identify laboratory test methods to discern changes in melting rate. One of the primary screening tools being used at SRNL for melting rate comparisons is the dry-fed melt rate furnace (MRF). The MRF has been very effective in ranking relative melting rates of candidate frits for the Defense Waste Processing Facility (DWPF) on the laboratory-scale, which has successfully translated to facility operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computed Tomography (CT) Analysis of 3D Printed Lattice Structures

LATTICE structures are increasingly used in product design across different industries, including the Department of Energy (DOE), due to their high strength and lightweight properties. These structures possess qualities such as high stiffness, energy absorption, large surface area, and structural support. To ensure lattice structures' quality and symmetry, it is crucial to have defect-free structures. However, in some cases, traditional non-destructive evaluation methods may not be practical due to encasing lattice structures in material. To analyze the lattice structures' quality, this project will employ CT imaging to gain access to the encased structures and perform a detailed analysis of each section. Three 3D printed complex lattice cubes were created, with two exposed and one encased in material, for this project. The CT X-ray cabinet will be used to scan all three cubes, and the data collected will be reconstructed and evaluated using complex interpretation software. This analysis will allow for a detailed examination of the structure's porosity, inclusions, cracks, wall thickness, and symmetry in each section.

36 MATERIALS SCIENCE↗

Three-Dimensional Imaging and Quantification of Gas Storativity in Nanoporous Media via X-rays Computed Tomography

This study provides the engineering science underpinnings for improved characterization and quantification of the interplay of gases with kerogen and minerals in shale. Natural nanoporous media such as shale (i.e., mudstone) often present with low permeability and dual porosity, making them difficult to characterize given the complex structural and chemical features across multiple scales. These structures give nanoporous solids a large surface area for gas to sorb. In oil and gas applications, full understanding of these media and their sorption characteristics are critical for evaluating gas reserves, flow, and storage for enhanced recovery and CO 2 sequestration potential. Other applications include CO 2 capture from industrial plants, hydrogen storage on sorbent surfaces, and heterogeneous catalysis in ammonia synthesis. Therefore, high-resolution experimental procedures are demanded to better understand the gas–solid behavior. In this study, CT imaging was applied on the sub-millimeter scale to shale samples (Eagle Ford and Wolfcamp) to improve quantitative agreement between CT-derived and pulse decay (mass balance) derived results. Improved CT imaging formulations are presented that better match mass balance results, highlighting the significance of gas sorption in complex nanoporous media. The proposed CT routine implemented on the Eagle Ford sample demonstrated a 17% error reduction (22% to 5%) when compared to the conventional CT procedure. These observations are consistent in the Wolfcamp sample, emphasizing the reliability of this technique for broader implementation of digital adsorption studies in nanoporous geomaterials.

42 ENGINEERING↗

SU-G-IeP4-14: Prostate Brachytherapy Activity Measurement and Source Localization by Using a Dual Photon Emission Computed Tomography System: A Feasibility Study

Purpose: To monitor the activity distribution and needle position during and after implantation in operating rooms. Methods: Simulation studies were conducted to assess the feasibility of measurement activity distribution and seed localization using the DuPECT system. The system consists of a LaBr3-based probe and planar detection heads, a collimation system, and a coincidence circuit. The two heads can be manipulated independently. Simplified Yb-169 brachytherapy seeds were used. A water-filled cylindrical phantom with a 40-mm diameter and 40-mm length was used to model a simplified prostate of the Asian man. Two simplified seeds were placed at a radial distance of 10 mm and tangential distance of 10 mm from the center of the phantom. The probe head was arranged perpendicular to the planar head. Results of various imaging durations were analyzed and the accuracy of the seed localization was assessed by calculating the centroid of the seed. Results: The reconstructed images indicate that the DuPECT can measure the activity distribution and locate the seeds dwelt in different positions intraoperatively. The calculated centroid on average turned out to be accurate within the pixel size of 0.5 mm. The two sources were identified when the duration is longer than 15 s. The sensitivity measured in water was merely 0.07 cps/MBq. Conclusion: Preliminary results show that the measurement of the activity distribution and seed localization are feasible using the DuPECT system intraoperatively. It indicates the DuPECT system has potential to be an approach for dose-distribution-validation. The efficacy of acvtivity distribution measurement and source localization using the DuPECT system will evaluated in more realistic phantom studies (e.g., various attenuation materials and greater number of seeds) in the future investigation.

60 APPLIED LIFE SCIENCES↗

Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET{sub HCT}/HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET{sub ACT}/ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV{sub max}), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET{sub HCT}, and for all patients the artifact was removed or reduced in the corresponding PET{sub ACT}. The impact of respiration artifact was the worst for lesions less than 50 cm{sup 3} and located below the dome of the diaphragm. For lesions in this group, the mean SUV{sub max} difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Meso-scale framework for modeling granular material using computed tomography

Numerical modeling of unconsolidated granular materials is comprised of multiple nonlinear phenomena. Accurately capturing these phenomena, including grain deformation and intergranular forces depends on resolving contact regions several orders of magnitude smaller than the grain size. Here, we investigate a method for capturing the morphology of the individual particles using computed X-ray and neutron tomography, which allows for accurate characterization of the interaction between grains. The ability of these numerical approaches to determine stress concentrations at grain contacts is important in order to capture catastrophic splitting of individual grains, which has been shown to play a key role in the plastic behavior of the granular material on the continuum level. Discretization approaches, including mesh refinement and finite element type selection are presented to capture high stress concentrations at contact points between grains. The effect of a grain’s coordination number on the stress concentrations is also investigated.

36 MATERIALS SCIENCE↗

Sinogram restoration in computed tomography with an edge-preserving penalty

Purpose: With the goal of producing a less computationally intensive alternative to fully iterative penalized-likelihood image reconstruction, our group has explored the use of penalized-likelihood sinogram restoration for transmission tomography. Previously, we have exclusively used a quadratic penalty in our restoration objective function. However, a quadratic penalty does not excel at preserving edges while reducing noise. Here, we derive a restoration update equation for nonquadratic penalties. Additionally, we perform a feasibility study to extend our sinogram restoration method to a helical cone-beam geometry and clinical data. Methods: A restoration update equation for nonquadratic penalties is derived using separable parabolic surrogates (SPS). A method for calculating sinogram degradation coefficients for a helical cone-beam geometry is proposed. Using simulated data, sinogram restorations are performed using both a quadratic penalty and the edge-preserving Huber penalty. After sinogram restoration, Fourier-based analytical methods are used to obtain reconstructions, and resolution-noise trade-offs are investigated. For the fan-beam geometry, a comparison is made to image-domain SPS reconstruction using the Huber penalty. The effects of varying object size and contrast are also investigated. For the helical cone-beam geometry, we investigate the effect of helical pitch (axial movement/rotation). Huber-penalty sinogram restoration is performed on 3D clinical data, and the reconstructed images are compared to those generated with no restoration. Results: We find that by applying the edge-preserving Huber penalty to our sinogram restoration methods, the reconstructed image has a better resolution-noise relationship than an image produced using a quadratic penalty in the sinogram restoration. However, we find that this relatively straightforward approach to edge preservation in the sinogram domain is affected by the physical size of imaged objects in addition to the contrast across the edge. This presents some disadvantages of this method relative to image-domain edge-preserving methods, although the computational burden of the sinogram-domain approach is much lower. For a helical cone-beam geometry, we found applying sinogram restoration in 3D was reasonable and that pitch did not make a significant difference in the general effect of sinogram restoration. The application of Huber-penalty sinogram restoration to clinical data resulted in a reconstruction with less noise while retaining resolution. Conclusions: Sinogram restoration with the Huber penalty is able to provide better resolution-noise performance than restoration with a quadratic penalty. Additionally, sinogram restoration with the Huber penalty is feasible for helical cone-beam CT and can be applied to clinical data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of polychromatic attenuation using computed tomography reconstructed images

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

NASA Discipline Musculoskeletal↗

Graphics processing unit management system for computed tomography

A method and apparatus for managing operation of graphics processing units in a computer system. A processing thread in the computer system controls processing of a set of sinogram data by a graphics processing unit to form a set of graphics data. An output thread in the computer system controls writing of the set of graphics data to a storage system. The graphics processing unit is available to perform processing of another set of sonogram data while the set of graphics data is written to the storage system such that the increased availability of a plurality of graphics processing units is present.

97 MATHEMATICS AND COMPUTING↗

Numerical Simulation of Permeability Change in Wellbore Cement Fractures after Geomechanical Stress and Geochemical Reactions Using X-ray Computed Tomography Imaging

X-ray microtomography (XMT) imaging combined with a three-dimensional (3D) computational fluid dynamics (CFD) modeling technique was used to study the effect of geochemical and geomechanical processes on fracture properties in composite Portland cement–basalt caprock core samples. The effect of fluid properties and flow conditions on fracture permeability was numerically studied by using fluids with varying physical properties and simulating different pressure conditions. CFD revealed that the application of geomechanical stress led to increased fluid flow, which resulted in increased fracture permeability. After CO2-reaction, XMT images displayed preferential precipitation of calcium carbonate within the fractures in the cement matrix and less precipitation in fractures located at the cement–basalt interface. CFD predicted changes in flow characteristics and differences in absolute values of flow properties due to different pressure gradients. CFD was able to highlight the profound effect of fluid properties on flow characteristics and hydraulic properties of fractures. This study demonstrates the applicability of XMT imaging and CFD as powerful tools for characterizing the hydraulic properties of fractures in a number of applications like geologic carbon sequestration and storage, hydraulic fracturing for shale gas production, and enhanced geothermal systems.

CO2 storage↗

Fast Megavoltage Computed Tomography: A Rapid Imaging Method for Total Body or Marrow Irradiation in Helical Tomotherapy

Purpose: Megavoltage computed tomographic (MVCT) imaging has been widely used for the 3-dimensional (3-D) setup of patients treated with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, the result of slow couch speeds of approximately 1 mm/s, which can be difficult for the patient to tolerate. We sought to develop an MVCT imaging method allowing faster couch speeds and to assess its accuracy for image guidance for HT. Methods and Materials: Three cadavers were scanned 4 times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm with a penalty term of total variation and with a conventional filtered back projection (FBP) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors from the 2 reconstruction algorithms were compared. This fast MVCT imaging was tested in 3 cases of total marrow irradiation as a clinical trial. Results: The 3-D registration errors of the MVCT images reconstructed with the IR algorithm were smaller than the errors of images reconstructed with the FBP algorithm at fast couch speeds (2, 3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, faster MVCT (3 mm/s couch speed) scanning reduced the imaging time and still generated images useful for anatomic registration. Conclusions: Fast MVCT with the IR algorithm is clinically feasible for large 3-D target localization, which may reduce the overall time for the treatment procedure. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area. Automated integration of this imaging is at least needed to further assess its clinical benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coronary Events and Anatomy After Arterial Switch Operation for Transposition of the Great Arteries: Detection by 16-Row Multislice Computed Tomography Angiography in Pediatric Patients

The purpose of this study was to evaluate the feasibility of multislice computed tomographic (MSCT) angiography as a noninvasive method for detecting ostial, proximal, and middle segment coronary stenosis or occlusion and anatomy in patients with transposition of the great arteries who had undergone arterial switch operation (ASO). Sixteen-detector-row MSCT angiography was performed in 16 patients treated with ASO for transposition of the great arteries. The median age was 10.3 years (range, 6.2-16.3 years). Sixteen-detector-row MSCT angiography was performed in 16 patients who had undergone ASO. CT imaging was performed in the craniocaudal direction from 2 cm above the carina up to the heart basis. Noninvasive assessment of coronary artery stenosis and anatomy were investigated by MSCT angiography. Two patients were excluded from the study because of artifacts. Of 14 evaluated patients, 1 patient had ostial stenosis (7.1%). A coronary artery anatomy variant was present in six patients: left main artery (LMA) and right coronary artery (RCA) originating from the right sinus as a single orifice (n = 2); left circumflex artery (LCX) originating from the RCA (n = 1); LMA and RCA, after branching to the LCX, originating separately from the right sinus (n = 1); and LMA (n = 1) and left anterior descending artery (LADA; n = 1) originating directly from the right sinus. Intramural bridging in the LAD (n = 2) was detected. Five patients were normal. In conclusion, MSCT angiography, as a noninvasive, feasible technique for assessing coronary stenosis or occlusion and anatomy, can be used in the follow-up of patients who have undergone ASO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Computed Tomography Angiography: Role in the Evaluation of Popliteal Artery Entrapment Syndrome

This study reviews our experience with dynamic computed tomographic angiography (CTA) as an imaging modality in the evaluation of popliteal artery entrapment syndrome (PAES). Eight patients with surgically proven PAES were included in this study. Dynamic CTA studies performed with the feet in neutral and plantar flexed positions were reviewed for the detailed anatomy of the region and to define the location and extent of the stenosis, occlusions and collateral circulation. These findings were compared with intraoperative observations. CTA provided adequate angiographic and anatomic information required to arrive at the diagnosis and make a surgical decision. Thirteen limbs were affected in eight patients. There was popliteal artery occlusion in four limbs, stenosis at rest that was accentuated on stress imaging in two limbs, and patent popliteal artery with marked stenosis on stress imaging in seven limbs. Long-segment stenosis was seen in functional entrapment compared to short-segment stenosis in anatomic PAES. Anteroposterior compression of the popliteal artery in anatomic PAES unlike the side-to-side compression in functional PAES was a unique observation in this study. The CTA and surgical characterisation and classification of PAES matched in all the patients, except for misinterpretation of compressing fibrous bands as accessory slips of muscles in three limbs. In conclusion, dynamic CTA is a robust diagnostic tool that provides clinically relevant information and serves as a rapidly performed and easily available 'one-stop-shop' imaging modality in the management of PAES.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using X-ray Micro-Computed Tomography to Three-Dimensionally Visualize the Foregut of the Glassy-Winged Sharpshooter ( Homalodisca vitripennis )

Dissecting the heads of small insects belonging to the order Hemiptera for detailed anatomical investigation with light or scanning electron microscopy is difficult, time-consuming, and destructive, often resulting in sample preparation artifacts. Nevertheless, the structural details of these insects often hold critical information regarding their interactions with bacterial pathogens. For example, the glassy-winged sharpshooter (GWSS) is an efficient vector of the bacterium Xylella fastidiosa, the causal agent of Pierce’s disease in grape vines, but the foregut of this species is exceptionally difficult to dissect. Here, we describe a simple, non-destructive method to investigate the structure of the anterior gut of GWSS using high-resolution micro-computed X-ray tomography (microCT). The use of microCT eliminates the need for destructive dissection and reveals the morphology of small insects in three dimensions, allowing the user to virtually dissect the sample. The use of microCT imaging is a promising and powerful tool in the entomological sciences for studying the structures of vector insects, especially for difficult-to-dissect regions such as the foregut.

54 ENVIRONMENTAL SCIENCES↗