Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Development and evaluation of a device for simultaneous uniaxial compression and optical imaging of cartilage samples in vitro

In this paper, we present a system that allows imaging of cartilage tissue via optical coherence tomography (OCT) during controlled uniaxial unconfined compression of cylindrical osteochondral cores in vitro. We describe the system design and conduct a static and dynamic performance analysis. While reference measurements yield a full scale maximum deviation of 0.14% in displacement, force can be measured with a full scale standard deviation of 1.4%. The dynamic performance evaluation indicates a high accuracy in force controlled mode up to 25 Hz, but it also reveals a strong effect of variance of sample mechanical properties on the tracking performance under displacement control. In order to counterbalance these disturbances, an adaptive feed forward approach was applied which finally resulted in an improved displacement tracking accuracy up to 3 Hz. A built-in imaging probe allows on-line monitoring of the sample via OCT while being loaded in the cultivation chamber. We show that cartilage topology and defects in the tissue can be observed and demonstrate the visualization of the compression process during static mechanical loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaching the third dimension

X-ray imaging is extensively used in medical and materials science. Traditionally, the depth dimension is obtained by turning the sample to gain different views. The famous penetrating properties of X-rays mean that projection views of the subject sample can be readily obtained in the linear absorption regime. 180 degrees of projections can then be combined using computed tomography (CT) methods to obtain a full 3D image, a technique extensively used in medical imaging. In the work now presented in Nature Materials, Stephan Hruszkewycz and colleagues have demonstrated genuine 3D imaging by a new method called 3D Bragg projection ptychography1. Our approach combines the 'side view' capability of using Bragg diffraction from a crystalline sample with the coherence capabilities of ptychography. Thus, it results in a 3D image from a 2D raster scan of a coherent beam across a sample that does not have to be rotated.

36 MATERIALS SCIENCE↗

Multifrequency imaging radar polarimetry: Depolarisation of radar echoes at three wavelengths

It is shown that high resolution imaging radar polarimeters can describe depolarization effects in great detail by measuring the complete Stokes matrix for small regions on the Earth's surface, permitting to distinguish between coherent polarization transformation by the surface and diffuse interactions that randomize the polarization state of the received wave. Multiwavelength polarimeter observations of a variety of types of terrain, including images of the coherent and diffuse parts of the received signal are presented. The diffuse image, in particular, is highly indicative of small-scale surface roughness, an effect illustrated by analyzing a set of polarimeter images acquired over lava fields of varying roughness.

Zebker, H. A.↗

Attosecond coherent control of oxygen dissociation by XUV-IR laser fields using three-dimensional momentum imaging

In this paper, we have performed ultrafast three-dimensional ion momentum imaging spectroscopy on the dissociative single ionization of oxygen molecules using attosecond pulse trains with a broad energy spectrum of 5–30 eV. High-resolution momentum imaging allows clear identification of vibrational structures corresponding to the predissociation of highly excited cationic states. By adding a pump infrared field that is synchronized with and polarized orthogonally to the XUV pulse train, and an additional probe IR field, we demonstrate how the yield of O + ions can be steered between different dissociation channels by coherently controlling the coupling between multiple O 2 + * electronic states on an attosecond time scale. Finally, time-dependent calculations in a single active electron approximation allow a qualitative analysis of ion yields for two orientations of the molecular axis.

74 ATOMIC AND MOLECULAR PHYSICS↗

Airborne synthetic aperture radar observations and simulations for waves in ice

The Canada Centre for Remote Sensing CV-580 aircraft collected C-band SAR data over the marginal ice zone off the east coast of Newfoundland during the Labrador Ice Margin Experiment (LIMEX) in March 1989. One component of the LIMEX '89 program was the study of ocean waves penetrating the marginal ice zone. We consider nearly coincidental observations of waves in ice by airborne SAR and wave-induced ice motion measurements. We explain the wave patterns observed in the SAR imagery, and the corresponding SAR image spectra, in terms of SAR wave imaging models. These include the well-known tilt cross-section modulation, linear, quasi-linear, and nonlinear velocity bunching forward mapping models (FMMs), and the assertion that the concept of coherence time limitation applies differently to the cases of waves in ice and open water. We modify the concept of the scene coherence time to include two parts: first, a decorrelation time deduced from the inherent azimuth cutoff in the nonlinear velocity bunching FMM; and second, the intrinsic scene coherence time which is a measure of the time scale over which an open water Bragg scattering patch retains its phase structure. Either of these coherence time scales could dominate the SAR image formation process, depending upon the environmental conditions (the wave spectrum and the wind speed, for example). Observed SAR image spectra and forward mapped ice motion package spectra are favorably compared.

Vachon, Paris W.↗

Ghost imaging of phase objects with classical incoherent light

We describe an optical setup for performing spatial Fourier filtering in ghost imaging with classical incoherent light. This is achieved by a modification of the conventional geometry for lensless ghost imaging. It is shown on the basis of classical coherence theory that with this technique one can realize what we call phase-contrast ghost imaging to visualize pure phase objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multidimensional Coherent Spectroscopy of van der Waals materials and heterostructures (Final Technical Report)

This project advanced multidimensional coherent spectroscopy (MDCS) and related spectroscopic-imaging methods as quantitative probes of many-body optical excitations in two-dimensional (2D) van der Waals (vdW) semiconductors and their heterostructures. Monolayer transition-metal dichalcogenides (TMDs) such as MoSe 2 and WSe 2 provide a uniquely strong platform for excitonic physics due to reduced dielectric screening, which enhances Coulomb interactions and makes higher-order correlated states (e.g., biexcitons and exciton–trion correlations) more prominent than in conventional bulk semiconductors. At the same time, the same sensitivity that enables strong interactions also increases susceptibility to spatial inhomogeneity—e.g., strain gradients, wrinkles, nanoscale disorder potentials, and charge puddling—which can broaden resonances, obscure interaction signatures, and complicate device-to-device reproducibility. The work reported here addressed this dual opportunity and challenge by: (i) developing and deploying coherent multidimensional methods (including double-quantum MDCS) capable of isolating interaction signals with reduced background, (ii) integrating electrostatic control to tune carrier populations and interaction strengths in situ, and (iii) introducing complementary spatially resolved photoluminescence (PL) techniques—hyperspectral PL imaging and polarization-/field-dependent PL lineshape analysis—to directly quantify disorder, strain, and localization that govern the coherent response.

36 MATERIALS SCIENCE↗

Three dimensional full-wave nonlinear acoustic simulations: Applications to ultrasound imaging

Characterization of acoustic waves that propagate nonlinearly in an inhomogeneous medium has significant applications to diagnostic and therapeutic ultrasound. The generation of an ultrasound image of human tissue is based on the complex physics of acoustic wave propagation: diffraction, reflection, scattering, frequency dependent attenuation, and nonlinearity. The nonlinearity of wave propagation is used to the advantage of diagnostic scanners that use the harmonic components of the ultrasonic signal to improve the resolution and penetration of clinical scanners. One approach to simulating ultrasound images is to make approximations that can reduce the physics to systems that have a low computational cost. Here a maximalist approach is taken and the full three dimensional wave physics is simulated with finite differences. This paper demonstrates how finite difference simulations for the nonlinear acoustic wave equation can be used to generate physically realistic two and three dimensional ultrasound images anywhere in the body. A specific intercostal liver imaging scenario for two cases: with the ribs in place, and with the ribs removed. This configuration provides an imaging scenario that cannot be performed in vivo but that can test the influence of the ribs on image quality. Several imaging properties are studied, in particular the beamplots, the spatial coherence at the transducer surface, the distributed phase aberration, and the lesion detectability for imaging at the fundamental and harmonic frequencies. The results indicate, counterintuitively, that at the fundamental frequency the beamplot improves due to the apodization effect of the ribs but at the same time there is more degradation from reverberation clutter. At the harmonic frequency there is significantly less improvement in the beamplot and also significantly less degradation from reverberation. It is shown that even though simulating the full propagation physics is computationally challenging it is necessary to quantify ultrasound image quality and its sources of degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigating Shear-dependent Object Detection Biases with Metacalibration

M ETACALIBRATION is a new technique for measuring weak gravitational lensing shear that is unbiased for isolated galaxy images. Here we test M ETACALIBRATION with overlapping, or "blended" galaxy images. Using standard M ETACALIBRATION , we find a few percent shear measurement bias for galaxy densities relevant for current surveys, and that this bias increases with increasing galaxy number density. We show that this bias is not due to blending itself, but rather to shear-dependent object detection. If object detection is shear-independent, no deblending of images is needed, in principle. We demonstrate that detection biases are accurately removed when including object detection in the M ETACALIBRATION process, a technique we call M ETADETECTION . This process involves applying an artificial shear to images of small regions of sky and performing detection on the sheared images, as well as measurements that are used to calculate a shear response. We demonstrate that the method can accurately recover weak shear signals even in highly blended scenes. In the M ETACALIBRATION process, the space between objects is sheared coherently, which does not perfectly match the real universe in which some, but not all, galaxy images are sheared coherently. We find that even for the worst case scenario, in which the space between objects is completely unsheared, the resulting shear bias is at most a few tenths of a percent for future surveys. We discuss additional technical challenges that must be met in order to implement M ETADETECTION for real surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Coherence Weighting Applied to FMC/TFM Data from Austenitic CRA Clad Lined Pipes

Lined pipe girth weld regions are challenging to inspect using ultrasonic techniques due to their anisotropic and inhomogeneous characteristics, which lead to noise and acoustic beam distortion. This paper is focused on the application of coherence weighting methods to decrease the background noise level and false indications on total focusing method (TFM) images, encompassing the triple boundary of mechanically lined pipes. Three coherence weighting approaches were used here; the coherence factor (CF), the sign CF (SCF) and the phase CF (PCF). All three were found capable to improve the TFM images, however, the CF and the SCF performed better due to their exponential sensitivity factors, unlike the PCF which has a linear sensitivity factor.

42 ENGINEERING↗

Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery

Purpose: Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. The authors report the safety and feasibility and illustrate common imaging findings of frequency-domain OCT (FD-OCT) imaging of the femoropopliteal artery in a series of 20 patients who underwent infrainguinal angioplasty. Methods: After crossing the lesion of interest, OCT was performed with a dextrose saline flush technique with simultaneous obstructive manual groin compression. An automatic pullback FD-OCT device was employed (each scan acquiring 54 mm of vessel lumen in 271 consecutive frames). OCT images were acquired before and after balloon dilatation and following provisional stenting if necessary and were evaluated for baseline characteristics of plaque or in-stent restenosis (ISR), vessel wall trauma after angioplasty, presence of thrombus, stent apposition, and tissue prolapse. Imaging follow-up was not included in this study's protocol. Results: Twenty-seven obstructive lesions (18 cases of de novo atherosclerosis and 9 of ISR) of the femoropopliteal artery were imaged and 148 acquisitions were analyzed in total. High-resolution intravascular OCT imaging with effective blood clearance was achieved in 93.9%. Failure was mainly attributed to preocclusive proximal lesions and/or collateral flow. Mixed features of lipid pool areas, calcium deposits, necrotic core, and fibrosis were identified in all of the imaged atherosclerotic lesions, whereas ISR was purely fibrotic. After balloon angioplasty, OCT identified extensive intimal tears in all cases and one case of severe dissection that biplane subtraction angiography failed to identify. Conclusions: Infrainguinal frequency-domain optical coherence tomography is safe and feasible and may provide intravascular high-resolution imaging of the femoropopliteal artery during infrainguinal angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wnt interaction and extracellular release of prominin-1/CD133 in human malignant melanoma cells

Prominin-1 (CD133) is the first identified gene of a novel class of pentaspan membrane glycoproteins. It is expressed by various epithelial and non-epithelial cells, and notably by stem and cancer stem cells. In non-cancerous cells such as neuro-epithelial and hematopoietic stem cells, prominin-1 is selectively concentrated in plasma membrane protrusions, and released into the extracellular milieu in association with small vesicles. Previously, we demonstrated that prominin-1 contributes to melanoma cells pro-metastatic properties and suggested that it may constitute a molecular target to prevent prominin-1-expressing melanomas from colonizing and growing in lymph nodes and distant organs. Here, we report that three distinct pools of prominin-1 co-exist in cultures of human FEMX-I metastatic melanoma. Morphologically, in addition to the plasma membrane localization, prominin-1 is found within the intracellular compartments, (e.g., Golgi apparatus) and in association with extracellular membrane vesicles. The latter prominin-1–positive structures appeared in three sizes (small, ≤40 nm; intermediates ∼40–80 nm, and large, >80 nm). Functionally, the down-regulation of prominin-1 in FEMX-I cells resulted in a significant reduction of number of lipid droplets as observed by coherent anti-Stokes Raman scattering image analysis and Oil red O staining, and surprisingly in a decrease in the nuclear localization of beta-catenin, a surrogate marker of Wnt activation. Moreover, the T-cell factor/lymphoid enhancer factor (TCF/LEF) promoter activity was 2 to 4 times higher in parental than in prominin-1-knockdown cells. Collectively, our results point to Wnt signaling and/or release of prominin-1–containing membrane vesicles as mediators of the pro-metastatic activity of prominin-1 in FEMX-I melanoma. - Highlights: ► First report of release of prominin-1–containing microvesicles from cancer cells. ► Pro-metastatic role of prominin-1–containing microvesicles in FEMX-I melanoma. ► Down-regulation of prominin-1 results in decreased nuclear localization of β-catenin. ► Wnt signaling as mediator of the pro-metastatic activity of prominin-1.

60 APPLIED LIFE SCIENCES↗

Programmable low-coherence wavefronts for enhanced localization

Engineering the properties of electromagnetic wavefronts has become essential to imaging, wireless security, sensing, and wireless communication. In particular, wavefronts that exhibit low spatial coherence can enable sensing functionalities with high accuracy and low latency. The typical use of such wavefronts cannot take advantage of these possibilities, as they require the ability to dynamically reconfigure the wavefront in a controllable and repeatable fashion, over a broad spectral bandwidth. Here, we propose a new approach for generating broadband reconfigurable wavefronts which not only exhibit low spatial coherence at a particular frequency, but are also decorrelated with the wavefronts simultaneously generated at other frequencies. We demonstrate that this frequency-domain decorrelation is a key feature that, in combination with dynamic reconfigurability, enables localization measurements with an order-of-magnitude improvement in accuracy compared to the state of the art.

36 MATERIALS SCIENCE↗

Electron diffraction using ultrafast electron bunches from a laser-wakefield accelerator at kHz repetition rate

We show that electron bunches in the 50-100 keV range can be produced from a laser wakefield accelerator using 10 mJ, 35 fs laser pulses operating at 0.5 kHz. It is shown that using a solenoid magnetic lens, the electron bunch distribution can be shaped. The resulting transverse and longitudinal coherence is suitable for producing diffraction images from a polycrystalline 10 nm aluminum foil. The high repetition rate, the stability of the electron source, and the fact that its uncorrelated bunch duration is below 100 fs make this approach promising for the development of sub-100 fs ultrafast electron diffraction experiments.

43 PARTICLE ACCELERATORS↗

Direct imaging of structural heterogeneity of the melt-spun Fe{sub 85.2}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 0.8} alloy

A structural heterogeneity of the melt-spun Fe{sub 85.2}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 0.8} alloy has been studied by spherical aberration (C{sub s}) corrected high-resolution transmission electron microscopy. Hollow-cone illumination imaging revealed that the density of coherent scattering regions in the as-quenched Fe{sub 85.2}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 0.8} alloy is much higher than that in the Fe{sub 76}Si{sub 9}B{sub 10}P{sub 5} bulk metallic glass. According to the C{sub s}-corrected TEM, crystalline atomic clusters, typically of ∼1 nm in diameter, are densely distributed in an amorphous matrix of Fe{sub 85.2}Si{sub 2}B{sub 8}P{sub 4}Cu{sub 0.8} alloy. Observation of four-fold and six-fold atomic arrangements of these clusters implies existence of Fe clusters with the body centered cubic structure. These Fe clusters must be responsible for the formation of ultrahigh-density α-Fe nanocrystals produced by post-annealing.

36 MATERIALS SCIENCE↗

Nanoscale femtosecond imaging of transient hot solid density plasmas with elemental and charge state sensitivity using resonant coherent diffraction

Here, we propose to exploit the low energy bandwidth, small wavelength, and penetration power of ultrashort pulses from XFELs for resonant Small Angle Scattering (SAXS) on plasma structures in laser excited plasmas. Small angle scattering allows to detect nanoscale density fluctuations in forward scattering direction. Typically, the SAXS signal from laser excited plasmas is expected to be dominated by the free electron distribution. We propose that the ionic scattering signal becomes visible when the X-ray energy is in resonance with an electron transition between two bound states (resonant coherent X-ray diffraction). In this case, the scattering cross-section dramatically increases so that the signal of X-ray scattering from ions silhouettes against the free electron scattering background which allows to measure the opacity and derived quantities with high spatial and temporal resolution, being fundamentally limited only by the X-ray wavelength and timing. Deriving quantities such as ion spatial distribution, charge state distribution, and plasma temperature with such high spatial and temporal resolution will make a vast number of processes in shortpulse laser-solid interaction accessible for direct experimental observation, e.g., hole-boring and shock propagation, filamentation and instability dynamics, electron transport, heating, and ultrafast ionization dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD-blob correlations in NSTX

This paper describes a study of the cross-correlations between edge fluctuations as seen in the gas puff imaging (GPI) diagnostic and low frequency coherent magnetic fluctuations (“MHD”) in H-mode plasmas in NSTX. The main new result was that large blobs in the SOL were significantly correlated with MHD activity the 3-6 kHz range in 21 of the 223 shots examined. There were also many other shots in which fluctuations in the GPI signal level and its peak radius Rpeak were correlated with MHD activity, but without any significant correlation of the MHD with large blobs. The structure and motion of the MHD is compared with that of the correlated blobs, and some possible theoretical mechanisms for the MHD-blob correlation are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods and algorithms for computer synthesis of holographic elements to obtain a complex impulse response of optical information processing systems based on modern spatial light modulators

The possibilities of designing optical devices for data processing and imaging based on the manipulation of coherent light beams by means of spatial light modulators (SLMs) are investigated. A review of commercially available SLMs is presented and the limitations of their complex modulation characteristics are analysed. The main problem of using present-day SLMs is the lack of the ability to modulate directly all states within a unit circle in the complex plane. In this regard, the characteristics of current methods for the synthesis of holographic elements are described that implement a given complex impulse response of the optical system and are optimal for using SLMs with purely amplitude, purely phase, and hybrid amplitude – phase modulation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗