Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Ground-state cooling enabled by critical coupling and dark entangled states

Here, we analyze the cooling of a mechanical resonator coupled to an ensemble of interacting two-level systems via an open quantum systems method. Using an exact analytical result, we find optimal cooling occurs when the phonon mode is critically coupled (γ ~ g) to the two-level system ensemble. Typical systems operate in suboptimal cooling regimes due to the intrinsic parameter mismatch (γ $\gg$ g) between the dissipative decay rate γ and the coupling factor g . To overcome this obstacle, we show that carefully engineering the coupling parameters through the strain profile of the mechanical resonator allows phonon cooling to proceed through the dark (subradiant) entangled states of an interacting ensemble, thereby resulting in optimal phonon cooling. Our findings provide an avenue for ground-state cooling and should be accessible for experimental demonstrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional simulation of the University of Hawai‘i FEL oscillator with cavity desynchronization

In this paper, we present three-dimensional, time-dependent simulations of the University of Hawai‘i (UH) at Mānoa free-electron laser (FEL) oscillator. Using beam parameters from the UH facility, we study the pass-by-pass evolution of the radiation field, including its temporal, spectral, and transverse properties. At nominal bunch length, the radiation pulse develops temporal spiking near saturation, together with sideband formation and increased sensitivity to machine timing jitter. Our results show that modest cavity desynchronization can enhance the radiation energy by 63%. Large cavity desynchronization, on the other hand, can effectively suppress the spiking instabilities and improve robustness to timing fluctuations. Finally, we simulate a short-bunch operational mode with a bunch length comparable to the slippage length, which accelerates saturation and further amplifies the FEL power. Overall, these results provide a quantitative foundation for pulse control studies in the UH FEL oscillator and a critical benchmark for future experimental validation and machine optimization.

free-electron lasers↗

A Large Bore Conduction Cooled Superconducting Magnet for the Princeton Axion Search

Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Trace-gas sensing using the compliance voltage of an external cavity quantum cascade laser

Quantum cascade lasers (QCLs) are increasingly being used to detect, identify, and measure levels of trace gases in the air. External cavity QCLs (ECQCLs) provide a broadly-tunable infrared source to measure absorption spectra of chemicals and provide high detection sensitivity and identification confidence. Applications include detecting chemical warfare agents and toxic industrial chemicals, monitoring building air quality, measuring greenhouse gases for atmospheric research, monitoring and controlling industrial processes, analyzing chemicals in exhaled breath for medical diagnostics, and many more. Compact, portable trace gas sensors enable in-field operation in a wide range of platforms, including handheld units for use by first responders, fixed installations for monitoring air quality, and lightweight sensors for deployment in unmanned aerial vehicles (UAVs). We present experimental demonstration of a new chemical sensing technique based on intracavity absorption in an external cavity quantum cascade laser (ECQCL). This new technique eliminates the need for an infrared photodetector and gas cell by detecting the intracavity absorption spectrum in the compliance voltage of the laser device itself. To demonstrate and characterize the technique, we measure infrared absorption spectra of chemicals including water vapor and Freon-134a. Sub-ppm detection limits in one second are achieved, with the potential for increased sensitivity after further optimization. The technique enables development of handheld, high-sensitivity, and high-accuracy trace gas sensors for in-field use.

infrared spectroscopy, quantum cascade laser, trac↗

TH-C-12A-08: New Compact 10 MV S-Band Linear Accelerator: 3D Finite-Element Design and Monte Carlo Dose Simulations

Purpose: To design a new compact S-band linac waveguide capable of producing a 10 MV x-ray beam, while maintaining the length (27.5 cm) of current 6 MV waveguides. This will allow higher x-ray energies to be used in our linac-MRI systems with the same footprint. Methods: Finite element software COMSOL Multiphysics was used to design an accelerator cavity matching one published in an experiment breakdown study, to ensure that our modeled cavities do not exceed the threshold electric fields published. This cavity was used as the basis for designing an accelerator waveguide, where each cavity of the full waveguide was tuned to resonate at 2.997 GHz by adjusting the cavity diameter. The RF field solution within the waveguide was calculated, and together with an electron-gun phase space generated using Opera3D/SCALA, were input into electron tracking software PARMELA to compute the electron phase space striking the x-ray target. This target phase space was then used in BEAM Monte Carlo simulations to generate percent depth doses curves for this new linac, which were then used to re-optimize the waveguide geometry. Results: The shunt impedance, Q-factor, and peak-to-mean electric field ratio were matched to those published for the breakdown study to within 0.1% error. After tuning the full waveguide, the peak surface fields are calculated to be 207 MV/m, 13% below the breakdown threshold, and a d-max depth of 2.42 cm, a D10/20 value of 1.59, compared to 2.45 cm and 1.59, respectively, for the simulated Varian 10 MV linac and brehmsstrahlung production efficiency 20% lower than a simulated Varian 10 MV linac. Conclusion: This work demonstrates the design of a functional 27.5 cm waveguide producing 10 MV photons with characteristics similar to a Varian 10 MV linac.

07 ISOTOPE AND RADIATION SOURCES↗

Fabrication Flaw Density and Distribution In Repairs to Reactor Pressure Vessel and Piping Welds

The Pacific Northwest National Laboratory is developing a generalized fabrication flaw distribution for the population of nuclear reactor pressure vessels and for piping welds in U.S. operating reactors. The purpose of the generalized flaw distribution is to predict component-specific flaw densities. The estimates of fabrication flaws are intended for use in fracture mechanics structural integrity assessments. Structural integrity assessments, such as estimating the frequency of loss-of-coolant accidents, are performed by computer codes that require, as input, accurate estimates of flaw densities. Welds from four different reactor pressure vessels and a collection of archived pipes have been studied to develop empirical estimates of fabrication flaw densities. This report describes the fabrication flaw distribution and characterization in the repair weld metal of vessels and piping. This work indicates that large flaws occur in these repairs. These results show that repair flaws are complex in composition and sometimes include cracks on the ends of the repair cavities. Parametric analysis using an exponential fit is performed on the data. The relevance of construction records is established for describing fabrication processes and product forms. An analysis of these records shows there was a significant change in repair frequency over the years when these components were fabricated. A description of repair flaw morphology is provided with a discussion of fracture mechanics significance. Fabrication flaws in repairs are characterized using optimized-access, high-sensitivity nondestructive ultrasonic testing. Flaw characterizations are then validated by other nondestructive evaluation techniques and complemented by destructive testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron Beam Diagnostics Of The JLAB UV FEL

In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A system of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.

43 PARTICLE ACCELERATORS↗

Surface Characterization of NbTiN Films for Accelerator Applications

The development of next-generation SRF cavities requires the deployment of innovative material solutions with RF performance beyond bulk Nb. Theoretical interest has stimulated efforts to grow and characterize thin multi-layer superconductor/insulator/superconductor (SIS) structures for their potential capability of supporting otherwise inaccessible surface magnetic fields in SRF cavities *. The ternary B1-compound NbTiN is among the candidate superconducting materials for SIS structures. Single crystal NbTiN films with thicknesses below 15 nm are also of interest for the development of high resolution, high sensitivity (SNSPD) detectors for particle physics application. Using DC reactive magnetron sputtering, NbTiN can be deposited with nominal superconducting parameters. This contribution presents the on-going material surface and superconducting properties characterization in order to optimize the NbTiN films for each application.

Beverstock, David R.↗

OECD MCCI Project: Small-Scale Water Ingression and Crust Strength Tests (SSWICS) (SSWICS-9 & 10 Design Report)

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanisms that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.20 m. This decoupling is not expected for a typical reactor cavity where the lateral span is much larger, ~5-6 m. Instead, the crust is expected to fracture under the weight of the coolant and the crust itself so that coolant contact with the melt is maintained. However, because of a lack of knowledge of the strength of the crust, one cannot be certain that it would actually fracture under such circumstances. SSWICS-9 & 10, in contrast to previous tests, are designed to optimize the ingot for load testing. A reduced amount of corium will be used in the quench test to produce a thinner ingot. The ingot will then be load tested without sectioning. This report details the design modifications and test conditions that will be used to carry out the SSWICS-9 & 10 quench tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Efficiency Low-Cost Solar Receiver for Use Ina a Supercritical CO 2 Recompression Cycle

This project has performed solar receiver designs for two supercritical carbon dioxide (sCO 2 ) power cycles. The first half of the program focused on a nominally 2 MWe power cycle, with a receiver designed for test at the Sandia Solar Thermal Test Facility. This led to an economical cavity-type receiver. The second half of the program focused on a 10 MWe power cycle, incorporating a surround open receiver. Rigorous component life and performance testing was performed in support of both receiver designs. The receiver performance objectives are set to conform to the US DOE goals of 6¢/kWh by 2020 . Key findings for both cavity-type and direct open receiver are highlighted below: A tube-based absorber design is impractical at specified temperatures, pressures and heat fluxes for the application; a plate-fin architecture however has been shown to meet performance and life targets; the $148/kW th cost of the design is significantly less than the SunShot cost target with a margin of 30%; the proposed receiver design is scalable, and may be applied to both modular cavity-type installations as well as large utility-scale open receiver installations; the design may be integrated with thermal storage systems, allowing for continuous high-efficiency electrical production during off-sun hours; costs associated with a direct sCO 2 receiver for a sCO 2 Brayton power cycle are comparable to those of a typical molten salt receiver; lifetimes in excess of the 90,000 hour goal are achievable with an optimal cell geometry; the thermal performance of the Brayton receiver is significantly higher than the industry standard, and enables at least a 30% efficiency improvement over the performance of the baseline steam-Rankine boiler/cycle system; brayton’s patent-pending quartz tube window provides a greater than five-percent efficiency benefit to the receiver by reducing both convection and radiation losses.

14 SOLAR ENERGY↗

OPTIMUS{sup TM} Packaging for Intermediate Level Wastes and Spent Fuel - 20129

NAC's OPTIMUS{sup TM} packaging is a family of Type B(U)F transportation packages designed for maximum flexibility and cost-efficiency to support shipment of a wide range of challenging wastes and materials. They are small, modular packaging designs meeting DOT weight limits for road transport. OPTIMUS{sup TM} contents include low level waste, mixed low-level waste, irradiated fuel waste and intermediate level waste. Contents can also include aerosol cans with compressed gas and liquefied gas propellants and standard DOT 3E lecture bottles for shipment to treatment facilities. OPTIMUS{sup TM} packaging provides a cost-effective solution for challenging and unique waste contents combined with design simplicity and operational flexibility meeting the requirements of both SSR-6 and 10 CFR 71 for Type B(U)F packaging. The modular design of the packaging components combined with the flexibility to add modified internals for enhanced packaging performance makes OPTIMUS{sup TM} the preferred solution for many radioactive material transportation needs. The OPTIMUS{sup TM} product line currently includes two packaging designs; OPTIMUS{sup TM}-L and OPTIMUS{sup TM}-H. OPTIMUS{sup TM}-L is a lightweight transportation packaging intended for low-activity wastes, whereas OPTIMUS{sup TM}-H is a larger, heavier package intended for high-activities wastes. Due to its small size and weight, six (6) to ten (10) OPTIMUS{sup TM}-L packages can be accommodated on a single legal-weight truck shipment, depending on the weight of the contents. For typical payloads, two (2) OPTIMUS{sup TM}-H packages can be accommodated on a single legal-weight truck shipment. The OPTIMUS{sup TM} packaging share the same cask containment vessel (CCV) in the OPTIMUS{sup TM}-H and OPTIMUS{sup TM}-L. The large cavity size of the CCV, which can accommodate a 416-liter (110-gallon) drum, combined with the small size, low weight and modularity of the OPTIMUS{sup TM} packaging provides unmatched flexibility. In this paper, NAC provides a technical overview of the OPTIMUS{sup TM} packaging and identifies the design features and technology advancements making the OPTIMUS{sup TM} a readily adaptable and flexible solution for packaging processing facilities, reactor and decommissioning wastes. Optimized shielding performance through the addition of internal shielding components and alternative shipping configurations are discussed. In addition, an overview of the first major deployment of the OPTIMUS{sup TM} packaging for the Whiteshell Laboratories Closure Project (WLCP) is discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of using intermediate x-ray energies for highly conformal extracranial radiotherapy

Purpose: To investigate the feasibility of using intermediate energy 2 MV x-rays for extracranial robotic intensity modulated radiation therapy. Methods: Two megavolts flattening filter free x-rays were simulated using the Monte Carlo code MCNP (v4c). A convolution/superposition dose calculation program was tuned to match the Monte Carlo calculation. The modeled 2 MV x-rays and actual 6 MV flattened x-rays from existing Varian Linacs were used in integrated beam orientation and fluence optimization for a head and neck, a liver, a lung, and a partial breast treatment. A column generation algorithm was used for the intensity modulation and beam orientation optimization. Identical optimization parameters were applied in three different planning modes for each site: 2, 6 MV, and dual energy 2/6 MV. Results: Excellent agreement was observed between the convolution/superposition and the Monte Carlo calculated percent depth dose profiles. For the patient plans, overall, the 2/6 MV x-ray plans had the best dosimetry followed by 2 MV only and 6 MV only plans. Between the two single energy plans, the PTV coverage was equivalent but 2 MV x-rays improved organs-at-risk sparing. For the head and neck case, the 2MV plan reduced lips, mandible, tongue, oral cavity, brain, larynx, left and right parotid gland mean doses by 14%, 8%, 4%, 14%, 24%, 6%, 30% and 16%, respectively. For the liver case, the 2 MV plan reduced the liver and body mean doses by 17% and 18%, respectively. For the lung case, lung V20, V10, and V5 were reduced by 13%, 25%, and 30%, respectively. V10 of heart with 2 MV plan was reduced by 59%. For the partial breast treatment, the 2 MV plan reduced the mean dose to the ipsilateral and contralateral lungs by 27% and 47%, respectively. The mean body dose was reduced by 16%. Conclusions: The authors showed the feasibility of using flattening filter free 2 MV x-rays for extracranial treatments as evidenced by equivalent or superior dosimetry compared to 6 MV plans using the same inverse noncoplanar intensity modulated planning method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aperiodic signals processing via parameter-tuning stochastic resonance in a photorefractive ring cavity

Based on solving numerically the generalized nonlinear Langevin equation describing the nonlinear dynamics of stochastic resonance by Fourth-order Runge-Kutta method, an aperiodic stochastic resonance based on an optical bistable system is numerically investigated. The numerical results show that a parameter-tuning stochastic resonance system can be realized by choosing the appropriate optical bistable parameters, which performs well in reconstructing aperiodic signals from a very high level of noise background. The influences of optical bistable parameters on the stochastic resonance effect are numerically analyzed via cross-correlation, and a maximum cross-correlation gain of 8 is obtained by optimizing optical bistable parameters. This provides a prospective method for reconstructing noise-hidden weak signals in all-optical signal processing systems.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo calculations for reference dosimetry of electron beams with the PTW Roos and NE2571 ion chambers

Purpose: To investigate recommendations for reference dosimetry of electron beams and gradient effects for the NE2571 chamber and to provide beam quality conversion factors using Monte Carlo simulations of the PTW Roos and NE2571 ion chambers. Methods: The EGSnrc code system is used to calculate the absorbed dose-to-water and the dose to the gas in fully modeled ion chambers as a function of depth in water. Electron beams are modeled using realistic accelerator simulations as well as beams modeled as collimated point sources from realistic electron beam spectra or monoenergetic electrons. Beam quality conversion factors are calculated with ratios of the doses to water and to the air in the ion chamber in electron beams and a cobalt-60 reference field. The overall ion chamber correction factor is studied using calculations of water-to-air stopping power ratios. Results: The use of an effective point of measurement shift of 1.55 mm from the front face of the PTW Roos chamber, which places the point of measurement inside the chamber cavity, minimizes the difference betweenR{sub 50}, the beam quality specifier, calculated from chamber simulations compared to that obtained using depth-dose calculations in water. A similar shift minimizes the variation of the overall ion chamber correction factor with depth to the practical range and reduces the root-mean-square deviation of a fit to calculated beam quality conversion factors at the reference depth as a function of R{sub 50}. Similarly, an upstream shift of 0.34 r{sub cav} allows a more accurate determination of R{sub 50} from NE2571 chamber calculations and reduces the variation of the overall ion chamber correction factor with depth. The determination of the gradient correction using a shift of 0.22 r{sub cav} optimizes the root-mean-square deviation of a fit to calculated beam quality conversion factors if all beams investigated are considered. However, if only clinical beams are considered, a good fit to results for beam quality conversion factors is obtained without explicitly correcting for gradient effects. The inadequacy of R{sub 50} to uniquely specify beam quality for the accurate selection of k{sub Q} factors is discussed. Systematic uncertainties in beam quality conversion factors are analyzed for the NE2571 chamber and amount to between 0.4% and 1.2% depending on assumptions used. Conclusions: The calculated beam quality conversion factors for the PTW Roos chamber obtained here are in good agreement with literature data. These results characterize the use of an NE2571 ion chamber for reference dosimetry of electron beams even in low-energy beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Whole Abdominal Radiotherapy After Surgery and Carboplatin/Taxane Chemotherapy for Advanced Ovarian Cancer: Phase I Study

Purpose: To assess the feasibility and toxicity of consolidative intensity-modulated whole abdominal radiotherapy (WAR) after surgery and chemotherapy in high-risk patients with advanced ovarian cancer. Methods and Materials: Ten patients with optimally debulked ovarian cancer International Federation of Gynecology and Obstetrics Stage IIIc were treated in a Phase I study with intensity-modulated WAR up to a total dose of 30 Gy in 1.5-Gy fractions as consolidation therapy after adjuvant carboplatin/taxane chemotherapy. Treatment was delivered using intensity-modulated radiotherapy in a step-and-shoot technique (n = 3) or a helical tomotherapy technique (n = 7). The planning target volume included the entire peritoneal cavity and the pelvic and para-aortal node regions. Organs at risk were kidneys, liver, heart, vertebral bodies, and pelvic bones. Results: Intensity-modulated WAR resulted in an excellent coverage of the planning target volume and an effective sparing of the organs at risk. The treatment was well tolerated, and no severe Grade 4 acute side effects occurred. Common Toxicity Criteria Grade III toxicities were as follows: diarrhea (n = 1), thrombocytopenia (n = 1), and leukopenia (n = 3). Radiotherapy could be completed by all the patients without any toxicity-related interruption. Median follow-up was 23 months, and 4 patients had tumor recurrence (intraperitoneal progression, n = 3; hepatic metastasis, n = 1). Small bowel obstruction caused by adhesions occurred in 3 patients. Conclusions: The results of this Phase I study showed for the first time, to our knowledge, the clinical feasibility of intensity-modulated whole abdominal radiotherapy, which could offer a new therapeutic option for consolidation treatment of advanced ovarian carcinoma after adjuvant chemotherapy in selected subgroups of patients. We initiated a Phase II study to further evaluate the toxicity of this intensive multimodal treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pros and Cons of the Acceleration Scheme (NF-IDS)

The overall goal of the acceleration systems: large acceptance acceleration to 25 GeV and beam shaping can be accomplished by various fixed field accelerators at different stages. They involve three superconducting linacs: a single pass linear Pre-accelerator followed by a pair of multi-pass Recirculating Linear Accelerators (RLA) and finally a nonâ scaling FFAG ring. The present baseline acceleration scenario has been optimized to take maximum advantage of appropriate acceleration scheme at a given stage. Pros and cons of various stages are discussed here in detail. The solenoid based Pre-accelerator offers very large acceptance and facilitates correction of energy gain across the bunch and significant longitudinal compression trough induced synchrotron motion. However, far off-crest acceleration reduces the effective acceleration gradient and adds complexity through the requirement of individual RF phase control for each cavity. Close proximity of strong solenoids and superc

43 PARTICLE ACCELERATORS↗

Preclinical Assessment of Volumetric Modulated Arc Therapy for Total Marrow Irradiation

Purpose: A preclinical investigation was undertaken to explore a treatment technique for total marrow irradiation using RapidArc, a volumetric modulated arc technique. Materials and Methods: Computed tomography datasets of 5 patients were included. Plans with eight overlapping coaxial arcs were optimized for 6-MV photon beams. Dose prescription was 12 Gy in 2 Gy per fraction, normalized so that 100% isodose covered 85% of the planning target volume (PTV). The PTV consisted of the whole skeleton (including ribs and sternum), from the top of the skull to the medium distal third of the femurs. Planning objectives for organs at risk (OARs) were constrained to a median dose <6 to 7 Gy. OARs included brain, eyes, oral cavity, parotids, thyroid, lungs, heart, kidneys, liver, spleen, stomach, abdominal cavity, bladder, rectum, and genitals. Pretreatment quality assurance consisted of portal dosimetry comparisons, scoring the delivery to calculation agreement with the gamma agreement index. Results: The median total body volume in the study was 57 liters (range, 49-81 liters), for an average diameter of 47 cm (range, 46-53 cm) and a total length ranging from 95 to 112 cm. The median PTV volume was 6.8 liters (range, 5.8-10.8 liters). The mean dose to PTV was 109% (range, 107-112%). The global mean of median dose to all OARs was 4.9 Gy (range, 4.5-5.1 Gy over the 5 patients). The individual mean of median doses per organ ranged from 2.3 Gy (oral cavity) to 7.3 Gy (bowels cavity). Preclinical quality assurance resulted in a mean gamma agreement index of 94.3 {+-} 5.1%. The delivery time measured from quality assurance runs was 13 minutes. Conclusion: Sparing of normal tissues with adequate coverage of skeletal bones was shown to be feasible with RapidArc. Pretreatment quality assurance measurements confirmed the technical agreement between expected and actually delivered dose distributions, suggesting the possibility of incorporating this technique in the treatment options for patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly collimated monoenergetic target-surface electron acceleration in near-critical-density plasmas

Optimized-quality monoenergetic target surface electron beams at MeV level with low normalized emittance (0.03π mm mrad) and high charge (30 pC) per shot have been obtained from 3 TW laser-solid interactions at a grazing incidence. The 2-Dimension particle-in-cell simulations suggest that electrons are wake-field accelerated in a large-scale, near-critical-density preplasma. It reveals that a bubble-like structure as an accelerating cavity appears in the near-critical-density plasma region and travels along the target surface. A bunch of electrons are pinched transversely and accelerated longitudinally by the wake field in the bubble. The outstanding normalized emittance and monochromaticity of such highly collimated surface electron beams could make it an ideal beam for fast ignition or may serve as an injector in traditional accelerators.

43 PARTICLE ACCELERATORS↗