Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updating Nuclear Energy Cost Estimates for Net Zero World Initiative

Energy modeling of decarbonized scenarios in integrated energy systems requires nuclear energy parameters that are critical for forecasting, modeling and cost structure analysis. Using updated real-world data has always been a challenge to estimate current nuclear reactors costs and deployment scenarios. Given this, an updated set of parameters for overnight capital costs and operation and maintenance costs are estimated for the Net Zero World initiative using recent reports that provided a vast set of open sources data inputs. This paper follows the methodology developed in the Net Zero World report and applies the new ranges estimated in the Gateway for Accelerated Innovation in Nuclear report that address many of the current challenges in obtaining accurate cost data for advanced nuclear concepts. The final goal is to provide new estimates of the overnight capital costs and operational costs for different countries. The present paper improves the earlier capital cost estimations, building on recent literature that aims to obtain accurate data for modeling and simulation to enhance energy system evaluations and support decision-making in areas like de-carbonization and capacity expansion. Finally, the paper compares the new cost estimates with the old cost results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrifying High-Efficiency Future Communities: Impact on Energy, Emissions, and Grid

To combat climate change and meet decarbonization goals, the building sector is improving energy efficiency and electrifying end uses to reduce carbon emissions from fossil fuels. All-electric buildings are becoming a trend among new constructions, introducing opportunities for decarbonization but also technical challenges and research gaps. For instance, further investigation is needed to understand how the adoption of energy efficiency measures (EEMs) and distributed energy resources (DERs) in all-electric communities would affect energy consumption, carbon emissions, and grid planning. This paper presents a case study of a mixed-use, all-electric community located in Denver, Colorado. We use URBANopt TM , a physics-based urban energy modeling platform to model the community and then evaluate the impact of EEMs and DERs (i.e., photovoltaics [PV], electric vehicles [EVs], and batteries) on the community's energy usage, carbon emissions, and peak demand. The results show that adding EEMs and PV led to both energy consumption and carbon emissions reductions across all building types. However, we saw fairly limited impact of EEMs and PV on buildings' peak demand in our case. Additionally, due to overnight EV charging activities and higher grid carbon intensity at night, the carbon emissions in multifamily buildings have a noticeable increase compared to scenarios without vehicles. Finally, the addition of batteries helped reduce peak demand by 11%-29%. The modeling workflow and evaluation methods can be applied to similar communities to evaluate their performance and the effect of integrating EEMs and DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RM3 Wave Tank Validation Model

An approximately 1/75th scale point absorber wave energy absorber was built to validate the testing systems of a 16k gallon single paddle wave tank. The model was build based on the RM3 design and incorporated a linear position sensor, a force transducer, and wetness detection sensors. The data set also includes motion tracking data of the device's two bodies acquired from 4x Qualisys cameras. The tank wave spectrum is measured by 4 ultrasonic water height sensors.

16 TIDAL AND WAVE POWER↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

A Physical Model Enhanced Data Driven Method for High-Resolution Residential Load Profile Generation

Residential buildings account for significant energy consumption, creating opportunities to offer grid services. As electric utilities seek to implement effective system operation strategies, understanding residential energy consumption patterns becomes essential; However, the time intervals of load profiles measured by utilities' smart meters are typically from 15 minutes to 60 minutes. The low-resolution data make it hard to extract appliance-level load information, which is critical for providing grid services. This paper presents a load profile generator designed to produce synthetic load profiles for residential buildings that emphasizes the importance of accurate representations of realistic energy consumption patterns. The generator takes realistic low-resolution residential load measurements and weather data as inputs, producing 1-minute interval profiles that match the characteristics of the original profiles. Further, this generator can be used to populate load profiles in areas where actual measurements are limited to improve the ability of utilities to analyze their distribution systems. By providing more high-resolution residential building load profiles, this tool supports electric utilities to enhance their residential building load control strategies and improve overall grid stability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Battery Modeling for Control-Oriented Techno-Economic Studies: Preprint

Electrochemical batteries, which serve as electric energy storage devices, are becoming increasingly popular among residential buildings that incorporate solar photovoltaic (PV) systems to help meet their energy needs. Battery economics are affected by performance degradation over time, and managing this degradation can help extend the battery's lifespan. The tradeoff between operational costs/benefits and managing battery degradation is of significant research interest. One of the key factors for assessing battery degradation is the dispatch strategy used to control the charging and discharging of the battery. Conventional dispatch strategies typically use simple rule-based methods, and these overly aggressive charging/discharging cycles can significantly reduce a battery’s life span. Our research seeks to develop optimized dispatch strategies for grid-connected PV homes with a goal of extending battery life while simultaneously taking into consideration utility costs and occupant comfort. To achieve this goal, we adapted lithium-ion battery life- and cyclic-degradation models for use in high-fidelity building simulations, so whole-building and grid-interactive controllers can dispatch the batteries along with other flexible loads. With the help of a co-simulation platform, we performed a simulation study to compute the optimized dispatch strategies for relevant operating conditions brought about by changing geographical locations, weather conditions, and utility pricing. Comparing the optimized strategies with the conventional strategies resulted in a >50% decrease in capacity degradation and >10% average reduction in operational costs during the months of January and July in Fort Collins, Colorado; Phoenix, Arizona; and Portland, Oregon.

30 DIRECT ENERGY CONVERSION↗

Model predictive control for active insulation in building envelopes

Active insulation systems (AISs) refer to building envelopes with insulation materials that can change their thermal conductivity and are coupled with thermal mass to reduce building energy consumption and peak power. In this research, a novel optimal control approach is proposed to evaluate the maximum theoretical energy and cost-saving potential of AISs. A time-varying model predictive control (TV-MPC) controller was used to optimally select the AIS mode and simultaneously determine the operation of the heating, ventilation and air conditioning (HVAC) system so that the maximum saving potential of the entire system can be realized. To comprehensively evaluate the power shifting flexibility of AISs, two optimization objectives—minimizing weekly electric energy consumption and minimizing weekly electricity cost—were considered. The summer season simulation results show that under the first objective, more than 50% electric and thermal energy was saved when the upper boundary of the indoor air temperature was set to 25 °C. Furthermore under the second optimization objective, 38% of the cost was saved. It can be expected that the developed approach can be easily applied to multiple types of AISs with different mechanisms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗

A physics-informed data-driven low order model for the wind velocity deficit at the wake of isolated buildings

Detailed simulations of the Atmospheric boundary layer (ABL) provides information on wind velocity, direction and turbulence for optimizing the design of wind turbines and wind farms and their operations. Distributed wind turbines have been considered for use in urban or suburban areas for covering energy needs using a sustainable energy solution. Simulations of high Reynolds number turbulent ABL flows past obstacles can be used for the prediction of the velocity deficit and turbulence characteristics in the leeward side of building-like obstacles, allowing for the estimation of power losses and fatigue loads in wind turbines. However, fully three-dimensional simulations of high Reynolds number ABL flows using Large Eddy Simulation (LES) or Reynolds Average Navier-Stokes Simulations (RANS) continue to require large computational/ execution times. As a result, these 3D simulations may not be ideal tools for the rapid assessment of wind energy potential. In the present study, 3D numerical results from wall resolved RANS simulations were used for the development of a low order model that allows the rapid assessment of wind velocity and turbulence in the leeward side of an isolated building.

17 WIND ENERGY↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NASA POWER: Providing Analysis-Ready, Cloud-Optimized Data for AI /ML Training and Applications in Earth Science

As global demand for sustainable development grows, the integration of Earth Observation (EO) data into decision making frameworks has become a primary objective for the scientific community. The NASA Prediction of Worldwide Energy Resources (POWER) project serves as a bridge between NASA EO data and the specialized needs of the renewable energy, sustainable infrastructure and agroclimatology communities. In this poster presentation we will present an overview of POWER data products and services along with its use in diverse research to decision-making workflows. By providing over 40 years of high-resolution historical, hourly and daily solar and meteorological data, POWER transforms satellite observations and global model reanalysis into actionable, Analysis-Ready Dataset (ARD). Currently, the project delivers over 250 industry-friendly parameters to the users from different NASA datasets like CERES SYN1Deg, MERRA-2, and IMERG alongside downscaled CMIP6 climate model data, fulfilling over 16 million requests from 50,000 unique users monthly. To ensure data quality and traceability, these parameters are rigorously validated against the ground-based observations from the Baseline Surface Radiation Network (BSRN) and the Global Surface Summary of the Day (GSOD) – these results will be discussed in the presentation. A newly introduced web-based PaRameter Uncertainty ViEwer (PRUVE) tool will be presented that provides an online validation platform to the users that benchmarks satellite-based and assimilation data products against these surface measurements. To reduce technical barriers to data adoption, POWER data is accessible through RESTful APIs, ESRI ArcGIS Image Services, a web-based Data Access Viewer tool, allowing users to visualize, validate and apply the dataset. For efficient data delivery POWER data is cloud-optimized into Zarr datastore accessible through NASA managed Amazon S3 ensures high-performance allowing users to integrate EO directly into operational pipelines. These customized services will be presented. Use cases from application will be presented from the energy sector - such as for design of generation systems, performance monitoring of solar power plants, in infrastructure sector- optimizing building energy efficiency and thermal comfort, in agriculture – such as driving crop simulation and yield forecasting models to enable climate resilient farming. Furthermore, the shift toward machine learning (ML) in EO research that has positioned POWER as a key provider for training datasets which will be discussed. Use-cases will be presented to showcase how NASA data is enabling the development of predictive tools for climate variability and resource management. The poster will present POWER’s future plans including technology development to enhance data traceability and reproducibility and improving I/O performance to support the rapid integration of new EO products, ensuring that POWER remains a robust scalable backend for the evolving landscape of AI-driven Earth Science. Additionally, POWER is developing an AI Agent and an MCP-Server to enable industry AI-Agentic workflows.

Neha Khadka↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model predictive control for optimal dispatch of chillers and thermal energy storage tank in airports

Cost of energy consumption is one of the biggest operational cost for airports, and it is increasing from time to time as airports expand to support growing number of passengers. Various factors affect the energy consumption including efficiency of airport Heating Ventilation and Air conditioning (HVAC) systems, which in turn depends on the efficiency of individual subsystems. Here, in this paper, we present an optimal scheduling method for the central plant system at Dallas Fort Worth airport, involving chillers, pumps, and a thermal energy storage (TES) system. A model predictive control (MPC) problem is formulated to minimize both energy and demand charge costs while satisfying the cooling needs of the airport. The proposed Mixed-Integer Nonlinear Programming (MINLP) formulation includes performance curve based models for chillers and pumps and a simplified state of charge model for TES. The formulation also includes predictions of cooling load and chilled water return temperature. Simulation results for a month in summer show savings around 10% compared to the baseline. Initial recommendations based on insights from simulation results to the manual operation procedures resulted in significant savings. Field test results show a 7% chiller efficiency improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Climate and air pollution implications of potential energy infrastructure and policy measures in India

India is a rapidly developing economy with interrelated air quality, sustainable development, and climate change mitigation goals. There are unique challenges to achieving each of these goals as well as potential tradeoffs among them. This study examines the implications of possible future energy, climate, and air pollution control policies and measures in India through 2050. We take a scenario approach using the GCAM global energy-climate-land model combined with the Hector simple climate model and the TM5-FASST air quality source-receptor model to examine energy, climate and air quality outcomes. Reducing use of traditional biomass in buildings can reduce primary carbonaceous particulate emissions well below 2015 levels. However, policies that are more ambitious than current plans would likely be required to reduce SO 2 and NO x emissions well below 2015 levels. Among single policy cases considered, pricing of greenhouse gas (GHG) emissions and expansion of natural gas infrastructure have the largest impacts on overall energy system changes relative to the reference scenario. Ambitious air pollution control and GHG policies lead to the largest reductions in air pollution concentrations and radiative forcing, respectively. However, ambitious air pollution control and GHG policies differ in the extent to which they support or impede other policy objectives. Forcing increases due to reduced aerosols from ambitious air pollution policies can be mitigated, at least in part, by applying air pollution control and GHG policies together.

India↗