Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Biological Research and Space Health Enabled by Machine Learning to Support Deep Space Missions

A key science goal of the NASA “Moon to Mars” campaign is to understand how biology responds to the Lunar, Martian, and deep space environments in order to advance fundamental knowledge, reduce risk, and support safe, productive human space missions. Through the powerful emerging computer science approaches of artificial intelligence (AI) and machine learning (ML), a paradigm shift has begun in biomedical science and engineered astronaut health systems, to enable Earth-independence and autonomy of mission operations. We present a decadal view of AI/ML architecture to support deep space mission goals, developed in concert with leaders in the field. We describe current AI/ML methods to support 1) fundamental biology, 2) in situ analytics, 3) high performance computing hardware, 4) automated science, 5) self-driving labs, 6) remote data management, 7) integrated real-time mission biomonitoring, and 8) a Precision Space Health system. Cutting-edge AI/ML approaches that can be integrated to support these domains include active learning, explainable AI, adaptive learning, causal inference, knowledge graphs, federated learning, transfer learning, and large language models. Finally, we present results from several current ML projects that are underway in the field to address key challenges of small sample n, high feature count, heterogeneity, and sparse data. These include 1) connecting omics data to phenotypic data using an ensemble model to infer causality of spaceflight rodent liver health disruption, 2) usage of explainable ML to interrogate the muscular underpinnings of spaceflight muscle atrophy, 3) ML models analyzing and determining directed acyclic graphs of human space health risk leveraging rodent bone datasets, 4) usage of large pre-trained models connecting biomedical knowledgebases with small spaceflight datasets to understand gene-to-gene interaction networks, and 5) a suite of benchmarked open science datasets (spaceflight mouse liver; radiation DNA damage) enabling programmers to identify the best ML algorithms to answer space biological science questions.

space biology↗

Artificial Intelligence Medical Support for Long-Duration Space Missions

We envision an artificial intelligence (AI) based system that will provide support and recommendations to the crew medical officer (CMO) and ground flight surgeon during long-duration space missions. Such a system would be pretrained on the knowledgebase of clinical knowledge on Earth, minimizing the amount of Earth data that needs to be transferred into space. Then during deployment, the system would be constantly refined through active learning from diverse streams of data from sensors in the spacecraft, data collected daily from individual astronauts, and human-in-the-loop feedback from the crew. The model could be interrogated for predictions and recommendations on personalized crew health based on the overall status of the spacecraft, medicinal stores, and status of other crew members. Adaptation techniques would be used to incorporate spaceflight data that have very different distributions from the training data due to the extreme environment. Edge computing and the most advanced neuromorphic processing would enable computation in scenarios with low power and bandwidth, while dimensionality reduction would be employed to ensure that the input data streams from spaceflight are as small as possible. In order to realize this long-term vision, several hardware and software aspects need to be developed and assembled. First, models pretrained on Earth biomedical data would need to be evaluated for predictive accuracy, and the best one selected. That model would need to be adapted to learn from diverse, sparse, and inconsistently measured data streams, as well as human-in-the-loop feedback. A data integration, standardization, and dimensionality reduction methodology would need to be developed to handle all data types and feed them into the model. Once the software and data infrastructure is developed, it would need to be integrated with small footprint compute processors and tested in high-radiation, high-vibration, unregulated temperature situations. As a short-term goal, we recommend to focus on the development of the data and model software structure. Several large language models (LLM) already exist that have been trained on Earth biomedical and clinical knowledgebases, including BioMedLLM, Med-PaLM, SPOKE LLM, and Foresight. These models need to be evaluated for accuracy and the best one chosen for a proof-of-concept structure, while maintaining awareness of the accelerating AI field and incorporating any newly improved model architectures as needed. Then, we recommend to develop a database of synthetic data types to mimic the diverse data streams that are expected in a long-duration space mission. This should include environmental and microbial data from the spacecraft, non-invasive data from wearables and point-of-care devices employed by astronauts, and more invasive molecular and physiological monitoring of clinical and biomarker data from astronauts. The data standardization methodology should be developed, and these data streams used to refine the clinical LLM. Several scenarios should be developed that could plausibly come up in a long-duration space mission, and changes or aberrations introduced to the data at specific times to mimic these scenarios. Then, question and answer tasks should be designed to interrogate the model for predictions and recommendations, with acceptable answers already identified.

Artificial Intelligence↗

Biological Research and Space Health Enabled by Machine Learning to Support Deep Space Missions

A key science goal of the NASA “Moon to Mars” campaign is to understand how biology responds to the Lunar, Martian, and deep space environments in order to advance fundamental knowledge, reduce risk, and support safe, productive human space missions. Through the powerful emerging approaches of artificial intelligence (AI) and machine learning (ML), a paradigm shift has begun in biomedical science and engineered astronaut health systems, to enable Earth independence and autonomy of mission operations. Here we present an overview of AI/ML architecture to support deep space mission goals, developed with leaders in the field. First, we focus on the fundamental biological research that supports our understanding of physiological responses to spaceflight, and we describe current efforts to support AI/ML research including data standardization and data engineering through maximally open and FAIR (findable, accessible, interoperable, reusable) databases and the generation of AI-ready datasets for reuse and analysis. We also discuss remote data management frameworks for research data as well as environmental and health data that are generated during deep space missions. We highlight several research projects that leverage data standardization and management for fundamental biological discovery to uncover the complex effects of space travel on living systems. Next, we provide an overview of cutting-edge AI/ML approaches that can be integrated to support remote monitoring and analysis during deep space missions, including generative models and large language models to learn the underlying biomedical patterns and predict outcomes or answer questions during off world medical scenarios. We also describe current AI/ML methods to support this research and monitoring through automated cloud-based labs which enable limited human intervention and closed-loop experimentation in remote settings. These labs could support mission autonomy by analyzing environmental data streams, and would be facilitated through in situ analytics capabilities to avoid sending large raw data files through low bandwidth communications. Finally, in the context of deep space missions with limited communications or access to medical advice from Earth, we describe a solution for integrated, real-time mission biomonitoring across hierarchical levels from continuous environmental monitoring, to wearables and point-of-care devices, to molecular and physiological monitoring. We introduce a precision space health system that will ensure that the future of space health is predictive, preventative, participatory and personalized.

artificial intelligence↗

NASA Open Science Data Repository: Open Science for Life in Space

Space biology and health data are critical for the success of deep space missions and sustainable human presence off-world. At the core of effectively managing biomedical risks is the commitment to open science principles, which ensure that data are findable, accessible, interoperable, reusable, reproducible and maximally open. The 2021 integration of the Ames Life Sciences Data Archive with GeneLab to establish the NASA Open Science Data Repository significantly enhanced access to a wide range of life sciences, biomedical-clinical, and mission telemetry data alongside existing ‘omics data from GeneLab. This paper describes the new database, its architecture, and new data streams supporting diverse data types and enhancing data submission, retrieval, and analysis. Features include the Biological Data Management Environment for improved data submission, a new user interface, controlled data access, an enhanced API, and comprehensive public visualization tools for environmental telemetry, radiation dosimetry data, and ‘omics analyses. By fostering global collaboration through its Analysis Working Groups and training programs, the Open Science Data Repository promotes widespread engagement in space biology, ensuring transparency and inclusivity in research. It supports the global scientific community in advancing our understanding of spaceflight's impact on biological systems, ensuring humans will thrive in future deep space missions.

OSDR↗

Increasing Data Discovery and Re-Use: The Space Life Sciences Ontology

Two of the most important goals of the adoption of the FAIR principles are increasing the ability of agents to find and re-use research data. Achieving these goals for space life sciences research is even more pressing, given the relatively expensive and scarce nature of these data. We have reported in the past on the progress made by exemplar life sciences data systems towards implementing FAIR, showing gaps particularly in the “interoperability area” of the principles; the lack of common conceptual models for space life science research is one reason for this gap. There were few available resources that define, annotate, categorize or otherwise relate various kinds of metadata describing the acquisition, nature, and intent of investigational space life sciences data. To address this gap, NASA is working with the Open Biological and Biomedical Ontology Foundry (https://obofoundry.org/) to develop the Space Life Science Ontology (SLSO) that is intended to support archival and other kinds of systems that operate using these data. The scope of the ontology includes concepts regarding those aspects of investigation design and execution specific or unique to space environments, such as types of specialized equipment, operating organizations, and documentation. The ontology is continually being developed and published to the life science community (https://github.com/nasa/LSDAO/); at the time of this publication, the SLSO newly and uniquely defines 30 types (classes), 90 properties, and 14 relations specific to space life sciences metadata. In addition, the SLSO reuses (imports) some 2,360 types (classes), 49 properties, and 393 relations from other ontologies that are relevant to these kinds of metadata. In addition to its role as a common conceptualization for space biomedical research activities, the SLSO can also be used to provide automated support for traditionally difficult and expensive activities such as data curation and cross-system data integration and analysis.

fair↗

Collaborative Research Proposal: Time Resolved Optical Emissions Spectroscopy and Laser Induced Fluorescence Spectroscopy of Nanosecond Pulsed Discharges in a Gas-Liquid Water Film Reactor

Electrical discharge plasma formed in contact with liquid water is of interest for a wide range of applications in chemical, biomedical, agricultural, electrical, and materials science and engineering. Such plasma reactors are of very timely importance since they also have significant disinfection capability by inactivating bacteria, viruses and other pathogens. Many types of plasma sources including those driven by AC, DC, RF, microwave, and pulsed electrical power supplies coupled to a wide range of different electrode configurations and reactor designs have been developed and explored which contact the plasma with liquid water. Recent roadmaps have recommended that further work is needed to develop our understanding of the fundamental chemical and physical process which occur at the interface of non-thermal plasma with liquid water solutions in order to advance this large diversity of applications which ultimately depend upon efficient production of key reactive chemical species. There is a wide range of interacting factors that affect the chemical reactions that occur in the plasma, in the liquid phase, and at the interface. These factors ultimately govern the key reactive chemical species formed and used in the various applications and they include a) the reactor design and input parameters, b) the discharge and transport processes, c) the plasma properties, and d) the resulting chemical reactions. For pulsed discharges, the power supply design and output parameters control the applied voltage, frequency, rise time, and width (duration) of the applied pulses. The reactor design involves specification of the gas-liquid contacting methods, electrode gap distance, reactor volume and shape, and gas and liquid flow rates achievable. The gas and liquid compositions as well as the liquid properties such as pH and conductivity are also of key importance in determination of the resulting chemical reactions. In addition, the important plasma properties include plasma gas temperature, electron density, electron energy (distribution), and size of the plasma channels which are all affected by the discharge and transport properties. Many studies have focused on specific aspects of these various processes. Of particular important and relevance to the proposed work is the utilization of nanosecond pulses to generate plasma in gas-liquid systems, liquid bubbles, underwater, and in gases. Recent advances in nanosecond pulses provide significant advantages in utilization with liquid water. For example, fast rise time and short pulses are less sensitive to water conductivity, such short pulses may provide advantages in fast temporal quenching of the plasma, and fundamental analysis of pulse properties, including pulse shape and width, may be facilitated by investigation of single filamentary fast pulses. Many studies have also dealt with the role of the gas composition on formation of reactive oxygen species (ROS) (i.e., hydroxyl radicals – ·OH, hydrogen peroxide – H 2 O 2 , various atomic oxygen species, ozone-O 3 , hydroperoxyl radicals HO 2 ·) and reactive nitrogen species (RNS) (i.e., nitrogen oxides – NO, NO 2 , N 2 O - collectively termed NO X , nitrite-NO 2 - , nitrate-NO 3 - , peroxynitrite-ONOO - ). The hydroxyl radical is the critical species in many chemical oxidation reactions for chemical degradation of toxic compounds in water and gases and for synthesis of some compounds. The mixture of various nitrogen oxide species is important for many biochemical and biological processes involved in biomedical and agricultural applications including disinfection and fertilizer production. The present proposal focuses on determination of the effects of time resolved electron density and hydroxyl radicals on plasma chemical reactions through collaboration with the Princeton Collaborative Low Temperature Plasma Research Facility (PCRF) at the Princeton Plasma Physics Laboratory (PPPL). In order to further investigate the role of the plasma generated electrons and hydroxyl radicals on the overall formation of the key species including hydrogen peroxide, hydroxyl radicals, and nitrogen oxides, the proposed work, thus seeks to determine high resolution time resolved electron density by optical emissions spectroscopy and time resolved hydroxyl radicals using laser induced fluorescence in the nanosecond discharge reactor. The combination of data on electron density and hydroxyl radical concentration will be utilized in the present work to more fully characterize the chemical reaction processes in this system and to advance the design, development, and operation of such chemical reactors for a wide range of applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding diseases at a molecular level

A group of scientists at Los Alamos National Laboratory in 2008 successfully pioneered a microscope able to track protein-sized, hard to see particles in three dimensions. The 3D Tracking Microscope, designed and developed by James H. Werner, Guillaume A. Lessard, Nathan Wells and Peter M. Goodwin of LANL's Center for Integrated Nanotechnologies, won a 2008 R&D 100 award. The team's invention is a unique confocal 3D tracking microscope capable of following the motion of nanometer-sized objects, such as individual molecules, quantum dots, organic fluorophores and single green fluorescent proteins as they zoom through three-dimensional space at rates faster than many intracellular transport processes. The 3D tracking microscope can follow the transport of nanometer-sized particles at micrometer per second rates. This enables researchers to follow individual protein, ribonucleic acid (RNA), or deoxyribonucleic acid (DNA) motion throughout the full three-dimensional volume of a cell to discover the path a particular biomolecule takes, the method it employs to get there and the specific proteins it may be interacting with along the way. In addition to applications in molecular spectroscopy and materials research, the 3D tracking microscope is a powerful tool primarily in the fields of cellular biology and biomedical research, Werner said. 'The 3D tracking microscope will advance our understanding of the molecular basis and kinetics of many diseases, such as cancer, diabetes, or muscular dystrophy,' he said. 'We anticipate the microscope will become a valuable weapon in the arsenal of biomedical researchers who are fighting to find cures for cancer, heart disease and other protein or DNA-based diseases.'

47 OTHER INSTRUMENTATION↗

Quantitative multiplex detection of biomarkers on a waveguide-based biosensor using quantum dots

The quantitative, simultaneous detection of multiple biomarkers with high sensitivity and specificity is critical for biomedical diagnostics, drug discovery and biomarker characterization [Wilson 2006, Tok 2006, Straub 2005, Joos 2002, Jani 2000]. Detection systems relying on optical signal transduction are, in general, advantageous because they are fast, portable, inexpensive, sensitive, and have the potential for multiplex detection of analytes of interest. However, conventional immunoassays for the detection of biomarkers, such as the Enzyme Linked Immunosorbant Assays (ELISAs) are semi-quantitative, time consuming and insensitive. ELISA assays are also limited by high non-specific binding, especially when used with complex biological samples such as serum and urine (REF). Organic fluorophores that are commonly used in such applications lack photostability and possess a narrow Stoke's shift that makes simultaneous detection of multiple fluorophores with a single excitation source difficult, thereby restricting their use in multiplex assays. The above limitations with traditional assay platforms have resulted in the increased use of nanotechnology-based tools and techniques in the fields of medical imaging [ref], targeted drug delivery [Caruthers 2007, Liu 2007], and sensing [ref]. One such area of increasing interest is the use of semiconductor quantum dots (QDs) for biomedical research and diagnostics [Gao and Cui 2004, Voura 2004, Michalet 2005, Chan 2002, Jaiswal 2004, Gao 2005, Medintz 2005, So 2006 2006, Wu 2003]. Compared to organic dyes, QDs provide several advantages for use in immunoassay platforms, including broad absorption bands with high extinction coefficients, narrow and symmetric emission bands with high quantum yields, high photostablility, and a large Stokes shift [Michalet 2005, Gu 2002]. These features prompted the use of QDs as probes in biodetection [Michalet 2005, Medintz 2005]. For example, Jaiswal et al. reported long term multiple color imaging of live cells using QD-bioconjugates [Jaiswal 2003]. Gao [Gao 2004] and So [So 2006] have used QDs as probes for in-vivo cancer targeting and imaging. Medintz et al. reported self-assembled QD-based biosensors for detection of analytes based on energy transfer [Medintz 2003]. Others have developed an approach for multiplex optical encoding of biomolecules using QDs [Han 2001]. Immunoassays have also benefited from the advantages of QDs. Recently, dihydrolipoic acid (DHLA) capped-QDs have been attached to antibodies and used as fluorescence reporters in plate-based multiplex immunoassays [Goodman 2004]. However, DHLA-QDs are associated with low quantum efficiency and are unstable at neutral pH. These problems limit the application of this technology to the sensitive detection of biomolecules, especially in complex biological samples. Thus, the development of a rapid, sensitive, quantitative, and specific multiplex platform for the detection of biomarkers in difficult samples remains an elusive target. The goal stated above has applications in many fields including medical diagnostics, biological research, and threat reduction. The current decade alone has seen the development of a need to rapidly and accurately detect potential biological warfare agents. For example, current methods for the detection of anthrax are grossly inadequate for a variety of reasons including long incubation time (5 days from time of exposure to onset of symptoms) and non-specific ('flu-like') symptoms. When five employees of the United State Senate were exposed to B. anthracis in the mail (2001), only one patient had a confirmed diagnosis before death. Since then, sandwich immunoassays using both colorimetric and fluorescence detectors have been developed for key components of the anthrax lethal toxin, namely protective antigen (PA), lethal factor (LF), and the edema factor [Mourez 2001]. While these platforms were successful in assays against anthrax toxins, the sensitivity was poor. Furthermore, no single platform exists for the simultaneous and quantitative detection of multiple components of the B. anthracis toxin. Addressing multiple biomarkers at the same time will increase confidence in a positive result, and may lead to application in the simultaneous detection of anthrax and other biowarfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deformable Organic Nanowire Field-Effect Transistors

Deformable electronic devices that are impervious to mechanical influence when mounted on surfaces of dynamically changing soft matters have great potential for next–generation implantable bioelectronic devices. Here, deformable field–effect transistors (FETs) composed of single organic nanowires (NWs) as the semiconductor are presented. The NWs are composed of fused thiophene diketopyrrolopyrrole based polymer semiconductor and high–molecular–weight polyethylene oxide as both the molecular binder and deformability enhancer. The obtained transistors show high field–effect mobility >8 cm 2 V –1 s –1 with poly(vinylidenefluoride– co –trifluoroethylene) polymer dielectric and can easily be deformed by applied strains (both 100% tensile and compressive strains). The electrical reliability and mechanical durability of the NWs can be significantly enhanced by forming serpentine–like structures of the NWs. Remarkably, the fully deformable NW FETs withstand 3D volume changes (>1700% and reverting back to original state) of a rubber balloon with constant current output, on the surface of which it is attached. In conclusion, the deformable transistors can robustly operate without noticeable degradation on a mechanically dynamic soft matter surface, e.g., a pulsating balloon (pulse rate: 40 min –1 (0.67 Hz) and 40% volume expansion) that mimics a beating heart, which underscores its potential for future biomedical applications.

36 MATERIALS SCIENCE↗

Recent Advances in 3D Printed Sensors: Materials, Design, and Manufacturing

Sensors are of great importance in different aspects of research and industry. Future sensors will require high-efficient and low-cost manufacturing, as well as high-performance functionality in areas, such as mechanical sensing, biomedical, and optical applications. Recent advances in 3D printing open a new paradigm for sensors fabrication as a precision, customizable, and seamless process. Here, in this article, the state-of-the-art 3D printing methods in sensors manufacturing is reviewed and the performance of the 3D printed sensing materials and devices is summarized. Special attention is paid to emerging multimaterial printing and 4D printing technologies, which will benefit the fabrication of a new generation of structures with multifunctionalities. The content on 3D printed sensors covers piezoelectric sensors, medical, and optical sensing devices. The performance of 3D printed sensors in comparison with the sensors made by traditional manufacturing is also covered. Finally, section 4 provides the viewpoints on the future development of 3D printed sensors.

36 MATERIALS SCIENCE↗

Silicone membranes to inhibit water uptake into thermoset polyurethane shape-memory polymer conductive composites

Electroactive shape memory polymer (SMP) composites capable of shape actuation via resistive heating are of interest for various biomedical applications. However, water uptake into SMPs will produce a depression of the glass transition temperature (T g ) resulting in shape recovery in vivo. While water actuated shape recovery may be useful, it is foreseen to be undesirable during early periods of surgical placement into the body. Silicone membranes have been previously reported to prevent release of conductive filler from an electroactive polymer composite in vivo. In this paper, a silicone membrane was used to inhibit water uptake into a thermoset SMP composite containing conductive filler. Thermoset polyurethane SMPs were loaded with either 5 wt % carbon black or 5 wt % carbon nanotubes, and subsequently coated with either an Al 2 O 3 - or silica-filled silicone membrane. It was observed that the silicone membranes, particularly the silica-filled membrane, reduced the rate of water absorption (37°C) and subsequent T g depression versus uncoated composites. Finally, in turn, this led to a reduction in the rate of recovery of the permanent shape when exposed to water at 37°C.

36 MATERIALS SCIENCE↗

Collaborative and Reproducible Research: Goals, Challenges, and Strategies

Combining imaging biomarkers with genomic and clinical phenotype data is the foundation of precision medicine research efforts. Yet, biomedical imaging research requires unique infrastructure compared with principally text-driven clinical electronic medical record (EMR) data. The issues are related to the binary nature of the file format and transport mechanism for medical images as well as the post-processing image segmentation and registration needed to combine anatomical and physiological imaging data sources. The SiiM Machine Learning Committee was formed to analyze the gaps and challenges surrounding research into machine learning in medical imaging and to find ways to mitigate these issues. At the 2017 annual meeting, a whiteboard session was held to rank the most pressing issues and develop strategies to meet them. The results, and further reflections, are summarized in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PathBot: A Radiology-Pathology Correlation Dashboard

Pathology is considered the “gold standard” of diagnostic medicine. The importance of radiology-pathology correlation is seen in interdepartmental patient conferences such as “tumor boards” and by the tradition of radiology resident immersion in a radiologic-pathology course at the American Institute of Radiologic Pathology. In practice, consistent pathology follow-up can be difficult due to time constraints and cumbersome electronic medical records. We present a radiology-pathology correlation dashboard that presents radiologists with pathology reports matched to their dictations, for both diagnostic imaging and image-guided procedures. In creating our dashboard, we utilized the RadLex ontology and National Center for Biomedical Ontology (NCBO) Annotator to identify anatomic concepts in pathology reports that could subsequently be mapped to relevant radiology reports, providing an automated method to match related radiology and pathology reports. Radiology-pathology matches are presented to the radiologist on a web-based dashboard. We found that our algorithm was highly specific in detecting matches. Our sensitivity was slightly lower than expected and could be attributed to missing anatomy concepts in the RadLex ontology, as well as limitations in our parent term hierarchical mapping and synonym recognition algorithms. By automating radiology-pathology correlation and presenting matches in a user-friendly dashboard format, we hope to encourage pathology follow-up in clinical radiology practice for purposes of self-education and to augment peer review. We also hope to provide a tool to facilitate the production of quality teaching files, lectures, and publications. Diagnostic images have a richer educational value when they are backed up by the gold standard of pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics-informed neural networks (PINNs) for fluid mechanics: a review

Despite the significant progress over the last 50 years in simulating flow problems using numerical discretization of the Navier–Stokes equations (NSE), we still cannot incorporate seamlessly noisy data into existing algorithms, mesh-generation is complex, and we cannot tackle high-dimensional problems governed by parametrized NSE. Moreover, solving inverse flow problems is often prohibitively expensive and requires complex and expensive formulations and new computer codes. Here, we review flow physics-informed learning, integrating seamlessly data and mathematical models, and implement them using physics-informed neural networks (PINNs). Here, we demonstrate the effectiveness of PINNs for inverse problems related to three-dimensional wake flows, supersonic flows, and biomedical flows.

42 ENGINEERING↗

A historical perspective on porphyrin-based metal–organic frameworks and their applications

Porphyrins are important molecules widely found in nature in the form of enzyme active sites and visible light absorption units. Recent interest in using these functional molecules as building blocks for the construction of metal–organic frameworks (MOFs) have rapidly increased due to the ease in which the locations of, and the distances between, the porphyrin units can be controlled in these porous crystalline materials. Porphyrin-based MOFs with atomically precise structures provide an ideal platform for the investigation of their structure–function relationships in the solid state without compromising accessibility to the inherent properties of the porphyrin building blocks. Here, this review will provide a historical overview of the development and applications of porphyrin-based MOFs from early studies focused on design and structures, to recent efforts on their utilization in biomimetic catalysis, photocatalysis, electrocatalysis, sensing, and biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Dioxide Conversion to Nanomaterials: Methods, Applications, and Challenges

Anthropogenic carbon dioxide (CO 2 ) emission is one of the biggest global threats that we are confronted with in the 21st century. A lack of prompt action to mitigate the atmospheric CO 2 level could lead to global catastrophic events. As a result of the significance of the aforementioned threat, multiple nations have agreed to enact carbon capture, storage, utilization, and sequestration (CCUS) technologies at academic and industrial scales with the aim of lowering the atmospheric CO 2 level. Although there are many reviews on CCUS technologies, there is a lack of comprehensive review on CO 2 conversion to more economically valuable products, such as nanomaterials. Carbon dioxide capture and conversion into nanomaterials is an interesting research topic in many ways because it contributes to our fundamental knowledge of material conversion, provides alternative ways to reduce atmospheric pollution, and yields lucrative products, which has not been explored broadly. Aside from the positive outcomes, we have a moral obligation to rectify a global threat caused by anthropogenic emission. Herein, we present current methods of converting CO 2 into organic and inorganic nanomaterials with a focus on operating conditions and challenges as well as the potential of nanomaterials in specifically biomedical applications as opposed to extensively reviewed energy-related uses. Furthermore, our review emphasizes the toxicity issues related to using such nanomaterials in biological settings based on literature and other comparable studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the near-wall accumulation of injectable particles in the microcirculation: smaller is not better

Although most nanofabrication techniques can control nano/micro particle (NMP) size over a wide range, the majority of NMPs for biomedical applications exhibits a diameter of ,100 nm. Here, the vascular distribution of spherical particles, from 10 to 1,000 nm in diameter, is studied using intravital microscopy and computational modeling. Small NMPs (#100 nm) are observed to move with Red Blood Cells (RBCs), presenting an uniform radial distribution and limited near-wall accumulation. Larger NMPs tend to preferentially accumulate next to the vessel walls, in a size-dependent manner (,70% for 1,000 nm NMPs). RBC-NMP geometrical interference only is responsible for this behavior. In a capillary flow, the effective radial dispersion coefficient of 1,000 nm particles is ,3-fold larger than Brownian diffusion. This suggests that sub-micron particles could deposit within diseased vascular districts more efficiently than conventional nanoparticles.

BIOMEDICAL MATERIALS↗