Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Longitudinal Diagnostics of Short Bunches at FLASH

Novel acceleration concepts such as laser- or beam-driven plasma acceleration require advanced diagnostic techniques to characterize and monitor the beam. A particular challenge is to measure bunch lengths of the order of 10 femtoseconds. Several methods are currently explored at the free-electron laser FLASH at DESY/Hamburg and will be discussed it this paper, such as electro-optical sampling, streaking bunches with a transversely deflecting cavity, and -most recently implemented at FLASH--the optical-replica synthesizer, a laser-based technique promising a time resolution of a few femtoseconds.

43 PARTICLE ACCELERATORS↗

Four-dimensional phase-space reconstruction of flat and magnetized beams using neural networks and differentiable simulations

Beams with cross-plane coupling or extreme asymmetries between the two transverse phase spaces are often encountered in particle accelerators. Flat beams with large transverse-emittance ratios are critical for future linear colliders. Similarly, magnetized beams with significant cross-plane coupling are expected to enhance the performance of electron cooling in hadron beams. Preparing these beams requires precise control and characterization of the four-dimensional transverse phase space. In this study, we employ generative phase-space reconstruction techniques to rapidly characterize magnetized and flat-beam phase-space distributions using a conventional quadrupole-scan method. The reconstruction technique is experimentally demonstrated on an electron beam produced at the Argonne Wakefield Accelerator and successfully benchmarked against conventional diagnostics techniques. Specifically, we show that predicted beam parameters from the reconstructed phase-space distributions (e.g., as magnetization and flat-beam emittances) are in excellent agreement with those measured from the conventional diagnostic methods. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Nonintrusive Emittance Measurement of 1GeV H- Beam with a Laser

A laser wire based transverse phase space measurement system has been developed at the Spallation Neutron Source (SNS). The system allows a nonintrusive measurement of 1GeV hydrogen ion (H-) beam at the high energy beam transport (HEBT). This paper describes the design, installation, and measurement performance of the system. Major technical challenges in the implementation and commissioning of the nonintrusive phase space diagnostics at high brightness particle accelerator facilities are discussed.

43 PARTICLE ACCELERATORS↗

Reconstruction of the 4D beam matrix

The widely used transverse parameters characterizing particle beams are the Twiss parameters. These parameters can be measured experimentally but they do not fully characterize the beam since they do not account for possible correlations in particle distribution between two transverse coordinates. These correlations may occur due to uncompensated magnetic field at the cathode or misalignment of focusing quadrupoles in the transport beamline. We test a novel diagnostic for diagnosing full 4D beam matrix which may be used to identify such imperfections. The diagnostic is based on transporting the beam through the beamline which includes a quadrupole and a skew quadrupole magnets and measuring the resulting 2D beam distribution at the screen downstream. Such a measurement can be viewed as measuring a 2D projection of the 4D distribution. Different settings of the quads provide measurements of different slices of the phase space. The reconstruction of the original beam matrix from a number of measurements is done using machine learning algorithm, which provides a fast and reliable way of reconstruction for an arbitrary configuration of the scanning beamline. In August 2024, we set up the diagnostic beamline to perform a quadrupole scan of the beam. The setup includes a skew quadrupole, a regular quadrupole, and a screen. The images on the screen were post-processed to remove experimental artifacts and enhance contrast by eliminating background noise outside the core of the distribution=. The rms parameters of the distribution were then calculated and used as inputs for the reconstruction algorithm. This algorithm attempts to determine the initial beam matrix that produces expected images on the screen closely matching the observed images across all quadrupole settings. The algorithm found a solution in which the expected rms parameters closely align with the observations. Validation of the results is planned for FY25.

43 PARTICLE ACCELERATORS↗

Development of Thomson scattering system on Shenguang-III prototype laser facility

A Thomson scattering diagnostic system, using a 263 nm laser as the probe beam, is designed and implemented on Shenguang-III prototype laser facility. The probe beam is provided by an additional beam line completed recently. The diagnostic system allows simultaneous measurements of both ion feature and red-shifted electron feature from plasmas in a high-temperature (≥2 keV) and high-density (≥10{sup 21} cm{sup −3}) regime. Delicate design is made to satisfy the requirements for successful detection of the electron feature. High-quality ion feature spectra have already been diagnosed via this system in recent experiments with gas-filled hohlraums.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of high-current electron beams from X pinches and wire array Z pinches

Some issues concerning high-current electron beam transport from the X pinch cross point to the diagnostic system and measurements of the beam current by Faraday cups are discussed. Results of computer simulation of electron beam propagation from the pinch to the Faraday cup give limits for the measured current for beams having different energy spreads. The beam is partially neutralized as it propagates from the X pinch to a diagnostic system, but within a Faraday cup diagnostic, space charge effects can be very important. Experimental results show evidence of such effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and Plans for a SRF Accelerator Test Faciliy at Fermilab

A superconducting RF accelerator test facility is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration secti on consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beamlines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of gene rating a 810 MeV electron beam with ILC beam intensity. Expansion plans of the facility are underway that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. In addition to testing accelerator components, this facilit y will be used to test RF power equipment, instrumentation, LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

43 PARTICLE ACCELERATORS↗

Time and space resolved interferometry for laser-generated fast electron measurements

A technique developed to measure in time and space the dynamics of the electron populations resulting from the irradiation of thin solids by ultraintense lasers is presented. It is a phase reflectometry technique that uses an optical probe beam reflecting off the target rear surface. The phase of the probe beam is sensitive to both laser-produced fast electrons of low-density streaming into vacuum and warm solid density electrons that are heated by the fast electrons. A time and space resolved interferometer allows to recover the phase of the probe beam sampling the target. The entire diagnostic is computationally modeled by calculating the probe beam phase when propagating through plasma density profiles originating from numerical calculations of plasma expansion. Matching the modeling to the experimental measurements allows retrieving the initial electron density and temperature of both populations locally at the target surface with very high temporal and spatial resolution ({approx}4 ps,6 {mu}m). Limitations and approximations of the diagnostic are discussed and analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Cloud Generation And Trapping in a Quadrupole Magnet at the Los Alamos PSR

A diagnostic to measure electron cloud formation and trapping in a quadrupole magnet has been developed, installed, and successfully tested at PSR. Beam studies with this diagnostic show that the electron flux striking the wall in the quadrupole is comparable to or larger than in an adjacent drift. In addition, the trapped electron signal, obtained using the sweeping feature of diagnostic, was larger than expected and decayed very slowly with an exponential time constant of 50 to 100 {micro}s. Experimental results were also obtained which suggest that a significant fraction of the electrons observed in the adjacent drift space were seeded by electrons ejected from the quadrupole.

43 PARTICLE ACCELERATORS↗

A collision timing monitor for SuperKEKB

The analysis of beamstrahlung radiation, emitted from a beam of charged particles due to the electromagnetic interaction with a second beam of charged particles, provides a diagnostic tool that can be used to monitor beam–beam collisions in a e + e - storage ring. In this paper we show that the beamstrahlung time profile is related to the timing of the collisions and the length of the beams, and how its measurement can be used to monitor and optimize collisions at the interaction point of the SuperKEKB collider. The method has a unique passive monitor capability, since it allows to monitor the timing of the collision without disturbing (scanning) the beam–beam timing, which needs to be measured to unprecedented accuracy at SuperKEKB. To measure the time dependence of beamstrahlung, here we describe a method based on nonlinear frequency mixing in a nonlinear crystal of beamstrahlung radiation with photons from a pulsed laser. We demonstrate that the method allows to measure and optimize the relative timing and length of the colliding bunches with 3% accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) [and subsequently titled] Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022) (Final Report)

This is the Final Technical Report for the DOE Measurement Innovation grant DE-SC0017998 titled Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) and subsequently titled Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 September 2017 – 31 May 2022. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that could improve understanding of magnetic equilibrium, edge localized modes in tokamaks, and bootstrap and Pfirsch-Schlüter currents in stellarators. We have performed simulations of a novel non-hydrogen beam-based diagnostic that would determine a local value (in the plasma) of the poloidal flux function by measuring the toroidal angle of the beam particles' velocity at a detector external to the plasma. The approach is similar to that of a Heavy Ion Beam Probe (HIBP), but would be able to operate with a smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key results include: Identification of the neutral and singly charged atoms that are most appropriate for use in the beam based diagnostic and the ionization cross-sections that are important for studying the plasma edge of a large device; Development of a promising geometry for operation in which the beam is injected horizontally near the torus midplane; Implementation of simulations using banana orbit trajectories of secondary beam ions to access plasma regions that are commonly in-accessible to an HIBP diagnostic, including sample volumes near the X-point of a diverted tokamak; Assessment of the ability of the diagnostic concept (originally developed under the assumption of, and reliant on, symmetry) to work in stellarators by performing simulations with both quasi-symmetric fields and non-quasi-symmetric fields; Measurement of noise levels with a prototype detector on a stellarator and exploration of techniques to minimize effects of noise on a diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Development of diagnostic and manipulation systems for space-charge dominated electron beams and confined electron plasmas in ELTRAP

Modifications have been implemented in the Penning-Malmberg device ELTRAP aimed at performing studies on the dynamics of space-charge dominated nanosecond electron bunches traveling along the magnetic field. In particular, a Thomson backscattering apparatus has been developed where an infrared (IR) laser pulse collides with the bunched electron beam. The frequency-shifted backscattered radiation, acquired by means of a photomultiplier (PMT), can be exploited to evaluate information on energy, energy spread and density of the bunch. The achievable sensitivity of the diagnostics has been estimated, and valuable information on the main parameters affecting the signal-to-noise (S/N) ratio has been obtained [B. Paroli, F. Cavaliere, M. Cavenago, F. De Luca, M. Ikram, G. Maero, C. Marini, R. Pozzoli, and M. Rome, JINST 7, P01008 (2012)]. A series of upgrades are under way, aimed at increasing the S/N ratio through the use of a new laser for the electron source, the insertion of a stray light shield, and the optimization of the detection electronics. Moreover, electromagnetic simulations relevant to the design and implementation of a microwave heating system are presented. The generation of an electron plasma in ELTRAP by means of a low-power radio frequency (RF) drive in the MHz range applied on one of the trap electrodes and under ultra-high vacuum (UHV) conditions has previously been demonstrated [B. Paroli, F. De Luca, G. Maero, F. Pozzoli, and M. Rome, Plasma Sources Sci. Technol. 19, 045013 (2010)]. The new heating system will allow the extension of the RF studies to the GHz range and in particular the production of a more energetic electron plasma via cyclotron resonant excitation.

43 PARTICLE ACCELERATORS↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Validation of the imaging neutral particle analyzer in nearly MHD quiescent plasmas using injected beam ions on DIII-D

The imaging neutral particle analyzer (INPA) is a scintillator-based diagnostic that provides energy and radially resolved measurements of confined fast ions. To verify operation, understanding, and modeling of the diagnostic performance, distributions of deuterium beam ions in low density, nearly MHD-quiescent plasmas are measured on the DIII-D tokamak using the INPA. Here, the distribution is altered by changing the pitch-angle scattering rate with electron cyclotron heating (ECH). Experimental images are mostly reproduced with simulation of core fast ions charge exchanging with injected beam and edge cold neutrals in classical cases. Image comparisons between the experiment and simulation show agreement with less than 25% discrepancies near the beam injection energy of 50 keV. Other strong passive signals, observed in a localized region on the image, are suggested to come from charge exchange between cold neutrals and fast ions around the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Megavoltage bremsstrahlung end point voltage diagnostic

In a material, a beam of x rays is accompanied by various kinds of secondary radiation, including Compton electrons from collisions between the x rays and the material's electrons. For megavoltage bremsstrahlung in air, many of these Compton electrons are forward-directed and fast enough to be deflected outside the beam's edge by a magnetic field perpendicular to the beam. At the beam's edge, the dose from the deflected Compton electrons has a pattern that depends on the radiation's end point energy. Dose patterns measured with radiochromic film on a nominally 1 and 2 MV linear accelerator agree reasonably well with the corresponding Monte Carlo computations. With further development, the dose pattern produced outside the beam by such a sweeper magnet could become a noninvasive way to monitor megavoltage bremsstrahlung, when the end point energies are difficult to determine with other methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present and Future X-ray Tomographic Microscopy at TOMCAT

During its first four years of life, the TOMCAT beamline at the Swiss Light Source has established itself as a state-of-the art hard x-ray tomographic microscopy endstation for experiments on a large variety of samples, ranging from the fields of biology to materials science. It routinely performs absorption as well as phase-contrast imaging with an isotropic voxel size ranging from 0.360 up to 14.8 microns. Phase contrast is obtained either with simple edge-enhancement, a modified transport of intensity approach or grating interferometry. Typical acquisition times are on the order of a few minutes, depending on energy and resolution. A recently implemented automatic sample exchanger is now available for high-throughput studies. In addition to further developments in phase-contrast imaging, current scientific activities at the beamline focus on pushing spatial and temporal resolution by a few orders of magnitude, aiming at nano- and 'real-time' tomography.

43 PARTICLE ACCELERATORS↗