Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Solid-state transformation of uranyl peroxide materials through high-level irradiation

The solid-state transformation of sodium uranyl triperoxide (Na 4 (UO 2 )(O 2 ) 3 ∙9H 2 O, NaUT) to sodium uranyl tricarbonate (Na 4 (UO 2 )(CO 3 ) 3 ) by radiolysis has been observed for the first time. The exposure of NaUT to 3 MGy gamma irradiation resulted in partial breakdown of the peroxides forming a mixed peroxide and carbonate species. The effects of He ion irradiation on NaUT was also investigated up to 225 MGy using both hydrated argon and dry argon. The complete conversion to the uranyl tricarbonate phase by 56 MGy using hydrated argon, while dry argon did not fully convert showing the importance of water in the system. He-ion irradiated NaUT samples all convert to the tricarbonate phase with time in air post radiation exposure. This transition was monitored via Raman spectroscopy, infrared spectroscopy (IR), and powder X-ray diffraction (PXRD) to further confirm the identity of the final product as the sodium uranyl tricarbonate, čejkaite. This transformation outlines a mechanism for the mobility of uranyl in natural environments and in the Hanford tanks.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Simultaneous Exposure of Cultured Human Lymphoblastic Cells to Simulated Microgravity and Radiation Increases Chromosome Aberrations

During space travel, humans are continuously exposed to two major environmental stresses, microgravity (μG) and space radiation. One of the fundamental questions is whether the two stressors are interactive. For over half a century, many studies were carried out in space, as well as using devices that simulated μG on the ground to investigate gravity effects on cells and organisms, and we have gained insights into how living organisms respond to μG. However, our knowledge on how to assess and manage human health risks in long-term mission to the Moon or Mars is drastically limited. For example, little information is available on how cells respond to simultaneous exposure to space radiation and μG. In this study, we analyzed the frequencies of chromosome aberrations (CA) in cultured human lymphoblastic TK6 cells exposed to X-ray or carbon ion under the simulated μG conditions. A higher frequency of both simple and complex types of CA were observed in cells exposed to radiation and μG simultaneously compared to CA frequency in cells exposed to radiation only. Our study shows that the dose response data on space radiation obtained at the 1G condition could lead to the underestimation of astronauts’ potential risk for health deterioration, including cancer. This study also emphasizes the importance of obtaining data on the molecular and cellular responses to irradiation under μG conditions.

59 BASIC BIOLOGICAL SCIENCES↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

Microbial Community Characteristics Largely Unaffected by X-Ray Computed Tomography of Sediment Cores

X-ray computed tomography (CT) scanning is used to study the physical characteristics of soil and sediment cores, allowing scientists to analyze stratigraphy without destroying core integrity. Microbiologists often work with geologists to understand the microbial properties in such cores; however, we do not know whether CT scanning alters microbial DNA such that DNA sequencing, a common method of community characterization, changes as a result of X-ray exposure. Our objective was to determine whether CT scanning affects the estimates of the composition of microbial communities that exist in cores. Sediment cores were extracted from a salt marsh and then submitted for CT scanning. We observed a minimal effect of CT scanning on microbial community composition in the sediment cores either when the cores were examined shortly after recovery from the field or after the cores had been stored for several weeks. In contrast, properties such as sediment layer and marsh location did affect microbial community structure. While we observed that CT scanning did not alter microbial community composition as a whole, we identified a few amplicon sequence variants (13 out of 7,037) that showed differential abundance patterns between scanned and unscanned samples among paired sample sets. Our overall conclusion is that the CT-scanning conditions typically used to obtain images for geological core characterization do not significantly alter microbial community structure. We stress that minimizing core exposure to X-rays is important if cores are to be studied for biological properties. Future investigations might consider variables, such as the length and energy of radiation exposure, the volume of the core, or the degree, to which microbial communities are stressed as important factors in assessing the impact of X-rays on microbes in geological cores.

59 BASIC BIOLOGICAL SCIENCES↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Ronchi shearing interferometry for wavefronts with circular symmetry

Ronchi testing of a focused electromagnetic wave has in the last few years been used extensively at X-ray free-electron laser (FEL) facilities to qualitatively evaluate the wavefront of the beam. It is a quick and straightforward test, is easy to interpret on the fly, and can be used to align phase plates that correct the focus of aberrated beams. In general, a single Ronchigram is not sufficient to gain complete quantitative knowledge of the wavefront. However the compound refractive lenses that are commonly used at X-ray FELs exhibit a strong circular symmetry in their aberration, and this can be exploited. Furthermore, a simple algorithm that uses a single recorded Ronchigram to recover the full wavefront of a nano-focused beam, assuming circular symmetry, is presented, and applied to experimental measurements at the Matter in Extreme Conditions instrument at the Linac Coherent Light Source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Helicity evolution at small x : quark to gluon and gluon to quark transition operators

We include the quark to gluon and gluon to quark shock-wave transition operators into the small Bjorken-x evolution equations for helicity in the flavor-singlet channel derived earlier in [1,2,3]. While such transitions do not affect the large-N c version of the evolution equations for helicity, the large-N c & N f equations are affected. (N c and N f are the numbers of quark colors and flavors, respectively.) We derive the corresponding corrected large-N c & N f equations for the polarized dipole amplitudes contributing to the flavor-singlet quark and gluon helicity distributions in the double-logarithmic approximation (DLA), resumming powers of α s ln 2 (1/x) with αs the strong coupling constant. We solve these equations iteratively and extract the polarized splitting functions up to four loops. We show that our splitting functions agree with the fixed-order perturbative calculations up to and including the existing three-loops results [4,5,6,7]. Similar to the large-Nc helicity evolution in the shock-wave approach [8], our large-N c & N f small-x splitting functions agree with those obtained in the infrared evolution equations framework from [9, 10] up to three loops, but appear to slightly disagree at four loops.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanoscale Strain and Octahedral Tilting Removes Structural and Nonradiative Defects in 2D-Templated FAPbI 3

The halide perovskite formamidinium lead iodide (FAPbI 3 ) is a prime candidate for photovoltaics due to its excellent optoelectronic properties, but its application has been limited due to its structural instability. The large size of the FA cation results in metastability of the photoactive cubic phase and a facile degradation into thermodynamically stable hexagonal phases at room temperature. Recently, the incorporation of two-dimensional (2D) Ruddlesden-Popper halide perovskite seeds into a FAPbI 3 precursor solution was shown to template the growth of and stabilize cubic FAPbI 3 . Here, in this study, we investigate the nanoscale structural and optoelectronic mechanisms behind the observed bulk stabilization using synchrotron-based X-ray microscopies. Nanoprobe X-ray diffraction reveals 2D-templated FAPbI 3 films exhibit an average compressive strain normal to the substrate of -3.3%, 2-fold larger than that of MACl-stabilized FAPbI 3 . This compression creates locally templated regions composed of tetragonal-phase FAPbI 3 distributed nonuniformly throughout the film with fewer crystalline defects than purely cubic regions. Scanning X-ray excited optical luminescence (X-ray analog of photoluminescence) reveals that this local templating results in increased radiative recombination and red-shifted band edge and emission. Our results provide insight into the microscopic mechanism for the phase stabilization of FAPbI 3 using 2D perovskites as templates.

X-ray diffraction↗

Back-to-back inclusive dijets in DIS at small x : Sudakov suppression and gluon saturation at NLO

Back-to-back dijet cross-sections in deeply inelastic scattering (DIS) at small xBj are suppressed by many-body multiple scattering and screening effects arising from gluon saturation at high parton densities. They are similarly sensitive in these kinematics to large Sudakov logarithms from soft gluon radiation. Uncovering novel physics in this DIS channel therefore requires understanding the interplay of the two phenomena. In this work, we compute the small $x_\text{Bj}$ inclusive dijet DIS cross-section in back-to-back kinematics at next-to-leading order (NLO) in the Color Glass Condensate effective field theory (CGC EFT). Our result includes, for the first time, all real and virtual NLO contributions to the impact factor. These include all Sudakov double and single logarithm contributions, as well as all other finite $\mathcal{O}(α_s)$ terms that contribute at this order. We demonstrate explicitly that resummations of small x and Sudakov logarithms can be performed simultaneously in the CGC EFT. This requires that the JIMWLK kernel for small x evolution of the Weizsäcker-Williams (WW) gluon distribution satisfies a kinematic constraint imposed by lifetime ordering of successive gluon emissions; the corresponding modifications to the kernel, corresponding to resummations of large double transverse logarithms, are precisely of the type required to stabilize JIMWLK evolution beyond leading logarithmicaccuracy. We compute the azimuthal harmonics of the NLO back-to-back distributions and show their sensitivity to both the unpolarized and linearly polarized WW gluon distributions. Finally, we discuss how TMD factorization is broken by an emergent saturation scale at small $x$.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Eco-friendly passive radiative cooling using recycled packaging plastics

Passive daytime radiative cooling, requiring zero external energy consumption, is a promising cooling strategy achieved by simultaneously reflecting solar irradiance and thermally radiating heat into the cold outer space (~3 K) through the atmospheric transparency window. However, current materials for passive radiative cooling face huge challenges, such as complicated fabrication approaches, expensive raw materials, and environmental requirements for practical applications. In line with the urgent need for plastic recycling to curb global environmental pollution, the recycled plastics are used to fabricate a passive radiative cooling material. Herein, the foam-paper composite (FPC) with excellent self-cooling capability is fabricated by a simple crushing-and-mixing procedure using recycled polystyrene (PS) foam and printer paper. The superhydrophobic PS foam particles not only protect the FPC from water damage for field applications but also reinforce its solar reflectivity via their porous structure. The cellulose fibers in printer paper can efficiently emit infrared thermal radiation into the cold outer space and bond dispersed PS foam particles together, further increasing its mechanical strength. The combination of highly diffusely reflective PS foam particles and fiber-based printer paper results in a reflectivity of 96% in the solar spectrum, a sub-ambient cooling performance of 8.4 degrees C, and a maximum radiative cooling power of 90 W/m2 during a 24-h cycle. Meanwhile, the FPC with high humidity can maintain its high solar reflectivity, which promotes its application in humid subtropical areas. Further, the low material cost and ease of fabrication will provide a path for effective daytime radiative cooling, especially in less developed areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio and X-Ray Observations of the Luminous Fast Blue Optical Transient AT 2020xnd

We present deep X-ray and radio observations of the fast blue optical transient (FBOT) AT 2020xnd/ZTF 20acigmel at z = 0.2433 from 13 days to 269 days after explosion. AT 2020xnd belongs to the category of optically luminous FBOTs with similarities to the archetypal event AT 2018cow. AT 2020xnd shows luminous radio emission reaching L ν ≈ 8 × 10 29 erg s -1 Hz -1 at 20 GHz and 75 days post-explosion, accompanied by luminous and rapidly fading soft X-ray emission peaking at L X ≈ 6 × 10 42 erg s -1 . Interpreting the radio emission in the context of synchrotron radiation from the explosion's shock interaction with the environment, we find that AT 2020xnd launched a high-velocity outflow (v ~ 0.1c–0.2c) propagating into a dense circumstellar medium (effective $\dot{M}\approx {10}^{-3}\,{M}_{\odot }$ yr -1 for an assumed wind velocity of v w = 1000 km s -1 ). Similar to AT 2018cow, the detected X-ray emission is in excess compared to the extrapolated synchrotron spectrum and constitutes a different emission component, possibly powered by accretion onto a newly formed black hole or neutron star. These properties make AT 2020xnd a high-redshift analog to AT 2018cow, and establish AT 2020xnd as the fourth member of the class of optically luminous FBOTs with luminous multiwavelength counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges in solving structures from radiation-damaged tomograms of protein nanocrystals assessed by simulation

Structure-determination methods are needed to resolve the atomic details that underlie protein function. X-ray crystallography has provided most of our knowledge of protein structure, but is constrained by the need for large, well ordered crystals and the loss of phase information. The rapidly developing methods of serial femtosecond crystallography, micro-electron diffraction and single-particle reconstruction circumvent the first of these limitations by enabling data collection from nanocrystals or purified proteins. However, the first two methods also suffer from the phase problem, while many proteins fall below the molecular-weight threshold required for single-particle reconstruction. Cryo-electron tomography of protein nanocrystals has the potential to overcome these obstacles of mainstream structure-determination methods. Here, a data-processing scheme is presented that combines routines from X-ray crystallography and new algorithms that have been developed to solve structures from tomograms of nanocrystals. This pipeline handles image-processing challenges specific to tomographic sampling of periodic specimens and is validated using simulated crystals. The tolerance of this workflow to the effects of radiation damage is also assessed. The simulations indicate a trade-off between a wider tilt range to facilitate merging data from multiple tomograms and a smaller tilt increment to improve phase accuracy. Since phase errors, but not merging errors, can be overcome with additional data sets, these results recommend distributing the dose over a wide angular range rather than using a finer sampling interval to solve the protein structure.

59 BASIC BIOLOGICAL SCIENCES↗

Soft X-ray quantum efficiency of a commercial CMOS imaging sensor

The demonstrated performance and cost-effectiveness of complementary metal-oxide-semiconductor (CMOS) sensors make them a potentially attractive option for low-cost space-based X-ray observatories. We have previously reported on the performance of a commercially available backside-illuminated Sony IMX290LLR-C CMOS sensor and found it to offer X-ray spectral resolutions comparable to the charged coupled devices (CCDs) aboard Suzaku and Chandra and to have a sufficient radiation hardness for use in low Earth orbit. Here, in this work, we report on the quantum efficiency (QE) of this sensor, an essential metric for modeling the sensitivity of an instrument as an X-ray detector. Using the Advanced Photon Source at Argonne National Laboratory, we measure the soft X-ray QE of this CMOS sensor to be 0.28 ± 0.02 at a photon energy of 490.5 eV. This energy was chosen for its proximity to the astrophysically important O VII triplet emission lines (~574 eV) studied by the HaloSat mission. Although not surpassing that of the back-illuminated CCDs aboard Suzaku and Chandra, this QE compares favorably to that of the front-illuminated CCDs aboard the same observatories and is competitive with that of the silicon drift detectors used aboard HaloSat, making it a strong candidate for use on future X-ray small satellite (SmallSat) missions.

47 OTHER INSTRUMENTATION↗

Plasmonic Ag nanocomposite phosphate glasses produced via γ-ray irradiation as reduction route

This paper reports on the impact of γ-ray irradiation (10, 100 kGy) on melt-quenched Ag + -doped phosphate glass and the effects of subsequent thermal processing leading to the production of plasmonic Ag nanocomposites. The γ-irradiated glasses were characterized alongside the pristine by differential scanning calorimetry (DSC), Raman spectroscopy, electron paramagnetic resonance (EPR) spectroscopy, optical absorption, and photoluminescence (PL) spectroscopy. DSC characterization showed consistent glass transition temperatures (T g ) before and after γ-irradiation whereas the crystallization temperatures tended to decrease with increasing γ-ray dose. However, a lack of alteration of the glass network structure was supported by Raman spectroscopy. Room temperature EPR spectra clearly showed the formation of phosphorus oxygen hole center (POHC) defects in the undoped host, in addition to another doublet likely associated with a P 3 defect. The presence of paramagnetic silver species encompassing Ag 2+ and 107/109 Ag 0 atoms was also indicated in the silver-activated glass together with POHC defects. Optical absorption spectra were also consistent with the presence of various radiation-induced centers. Further analyzing the glass absorption edge via Tauc plots suggested the formation of electron center (EC) defects in γ-irradiated samples wherein the silver-doped glass exhibited decreasing band gap energies with increasing γ-ray dose. The PL characterization showed the silver-related radio-PL effect was induced exhibiting broad band emission with two maxima around 500 and 625 nm stemming from various molecular Ag$^{x+}_{n}$ clusters. Emission decay analyses revealed that the longer wavelength emission exhibited slower decay. The highest radiation dose of 100 kGy however resulted in weaker emission and faster decay kinetics attributed to energy transfer between the luminescent silver species and POHC defects. Finally subjecting the γ-irradiated Ag-doped glasses to heat treatment near the T g at 490 °C led to the development of the surface plasmon resonance of Ag nanoparticles (NPs) and the vanishing of the Ag$^{x+}_{n}$ clusters luminescence. In conclusion, the presence of the matrix-related EC defects was deemed accountable for the thermally induced reduction and consequent precipitation of Ag NPs making the plasmonic glasses attractive for photonic applications such as nonlinear optics.

36 MATERIALS SCIENCE↗

Progress in DIII-D towards validating divertor power exhaust predictions

In this study, UEDGE simulations highlight the role of cross-field drifts on the onset of detached conditions, and new calibrated divertor vacuum ultra violet (VUV) spectroscopy is used to challenge the predictions of radiative constituents in these simulations. UEDGE simulations for DIII-D H-mode plasmas with the open divertor with the ion ∇B-drift towards the X-point show a bifurcated onset of the low field side (LFS) divertor detachment, consistent with experimentally observed step-like detachment onset (Jaervinen A.E. et al 2018 Phys. Rev. Lett. 121 075001). The divertor plasma in the simulations exhibits hysteresis in upstream separatrix density between attached and detached solution branches. Reducing the drift magnitude by a factor of 3 eliminates the step-like detachment onset in the simulations, confirming the strong role of drifts in the bifurcated detachment onset. When measured local plasma densities and temperatures are within proximity of predicted values in the simulations, there is no shortfall of the local emission of the dominant resonant radiating lines. However, the simulations systematically predict a factor of two lower total integrated radiated power than measured by the bolometer with the difference lost through radial heat flow out of the computational domain. Even though there is no shortfall in the emission of the dominant lines, a shortfall of total radiated power can be caused by underpredicted spatial extent of the radiation front, indicating a potential upstream or divertor transport physics origin for the radiation shortfall, or shortfall of radiated power in the spectrum between the dominant lines. In addition to the underpredicted spatial extent, in detached conditions, the simulations overpredict the peak radiation and dominant carbon lines near the X-point, which can be alleviated by manually increasing divertor diffusivity in the simulations, highlighting the ad hoc cross-field transport as one of the key limitations of the predictive capability of these divertor fluid codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗