Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Raman scattering measurements in flames using a tunable KrF excimer laser

A narrow-band tunable KrF excimer laser is used as a spontaneous vibrational Raman scattering source to demonstrate that single-pulse concentration and temperature measurements, with only minimal fluorescence interference, are possible for all major species (O2, N2, H2O, and H2) at all stoichiometries (fuel-lean to fuel rich) of H2-air flames. Photon-statistics-limited precisions in these instantaneous and spatially resolved single-pulse measurements are typically 5 percent, which are based on the relative standard deviations of single-pulse probability distributions. In addition to the single-pulse N2 Stokes/anti-Stokes ratio temperature measurement technique, a time-averaged temperature measurement technique is presented that matches the N2 Stokes Raman spectrum to theoretical spectra by using a single intermediate state frequency to account for near-resonance enhancement. Raman flame spectra in CH4-air flames are presented that have good signal-to-noise characteristics and show promise for single-pulse UV Raman measurements in hydrocarbon flames.

Wehrmeyer, Joseph A.↗

Development and Test Results of Thermocouples Used in the TRISO-Fuel Irradiation Experiment AGR-5/6/7

High-temperature gas reactor irradiation experiments create unique challenges for thermocouple-based temperature measurements. High-temperature industrial thermocouples suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. For lower-temperature applications, Type K and Type N thermocouples are affected by neutron irradiation only to a limited extent. But until recently, the use of these nickel-based thermocouples was limited when the temperature exceeded 1050°C due to drift related to phenomena other than nuclear irradiation. Certain portions of the AGR-5/6/7 experiment experienced temperatures higher than any of the previous AGR tests, up to 1500°C. Recognizing the limitations of existing thermometry to measure such high temperatures, the sponsor of the AGR-5/6/7 test supported a development and testing program for thermocouples capable of low-drift operation at temperatures above 1100°C. This program included additional development of high-temperature irradiation-resistant thermocouples based on molybdenum/niobium thermoelements, which have been studied at Idaho National Laboratory since circa 2004. A step change in accuracy and long-term stability of this thermocouple type was achieved as part of the AGR-5/6/7 thermometry development program. Additionally, long-term testing (7000+ h) at 1250°C of Type N thermocouples utilizing a customized sheath developed at the University of Cambridge has been completed with excellent low-drift results. The results of this testing as well as testing of the improved high-temperature irradiation-resistant design are reported herein. Both the improved high-temperature irradiation-resistant and the Cambridge Type N thermocouple types were incorporated into the AGR-5/6/7 test, which began irradiation in February 2018 and was completed in July 2020. Finally, a summary of the performance of the thermocouples incorporated into the AGR-5/6/7 test is included herein.

In-pile instrumentation↗

Implanted telemeter for electrocardiogram and body temperature

Measuring system requiring one blocking oscillator to generate modulated pulse repetition rate is implantable in the bodies of small animals. Device has life of two years and transmission range of about three feet. EKG sensing unit also is used to sense electromyogram or electrooculogram of laboratory animals.

Barrows, W. F.↗

Satellite (Timed, Aura, Aqua) and In Situ (Meteorological Rockets, Balloons) Measurement Comparability

Measurements using the inflatable falling sphere often are requested to provide density data in support of special sounding rocket launchings into the mesosphere and thermosphere. To insure density measurements within narrow time frames and close in space, the inflatable falling sphere is launched within minutes of the major test. Sphere measurements are reliable for the most part, however, availability of these rocket systems has become more difficult and, in fact, these instruments no longer are manufactured resulting in a reduction of the meager stockpile of instruments. Sphere measurements also are used to validate remotely measured temperatures and have the advantage of measuring small-scale atmospheric features. Even so, with the dearth of remaining falling spheres perhaps it is time to consider whether the remote measurements are mature enough to stand alone. Presented are two field studies, one in 2003 from Northern Sweden and one in 2010 from the vicinity of Kwajalein Atoll that compare temperature retrievals between satellite and in situ failing spheres. The major satellite instruments employed are SABER, MLS, and AIRS. The comparisons indicate that remotely measured temperatures mimic the sphere temperature measurements quite well. The data also confirm that satellite retrievals, while not always at the exact location required for individual studies, are adaptable enough and highly useful. Although the falling sphere will provide a measurement at a specific location and time, satellites only pass a given location daily or less often. This report reveals that averaged satellite measurements can provide temperatures and densities comparable to the falling sphere.

Schmidlin, F. J.↗

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health↗

A temperature-induced hysteretic behavior of resistivity and magnetoresistance of electrodeposited bismuth microbridges for X-ray transition-edge sensor absorbers

This study investigates the temperature-induced hysteretic behavior of resistivity and magnetoresistance in electrodeposited bismuth films, with a focus on their application as absorbers in transition-edge sensors (TESs) for X-ray detection. Through a series of resistivity versus temperature measurements from room temperature to a few Kelvin, we explore the change in the conductive behavior of bismuth electrodeposited on various substrates. Our findings show for the first time both hysteretic and irreversible changes in resistivity as a function of temperature. Further, magnetoresistance measurements reveal notable variations in resistance behavior under different magnetic fields, highlighting the impact of magnetic fields on these films’ electronic transport properties, with an indication of potential weak anti-localization effects at the lowest temperatures. This study not only provides a deeper understanding of bismuth’s conductivity characteristics at low temperatures but also sheds light on the practical implications for developing more effective TESs for synchrotron X-ray facilities.

42 ENGINEERING↗

A high-speed spatial (linear) scanning pyrometer: A tool for diagnostics, temperature mapping, and property determinations at high temperatures

Development of a fast spatial scanning pyrometer for temperature measurements above 1500 K is described. The salient features of the pyrometer are: (1) it measures spectral radiance temperature (at 0.65 micron) at 1024 points along a straight line (25 mm long) on the target; (2) it has no moving parts and uses a self-scanning linear array of silicon photodiodes as the detector; (3) its output is recorded digitally every 1 microsec with a full-scale resolution of about 1 part in 4000, permitting performance of a complete cycle of measurements (1024 points) in about 1 ms. Operational characteristics of the pyrometer are given. Examples of measurements of the temperature along rapidly heated (resistive self-heating) specimens (rod, tube, strip) are presented. Potential use of the pyrometer in the experiments, both ground-based and in microgravity, requiring temperature mapping and property distribution of the specimen at high temperatures is discussed.

Cezairliyan, A.↗

miniDOT Logger Dissolved Oxygen and Temperature Data of Wetland Surface Water, Old Woman Creek NERR, Huron, OH, 2022-06-15 to 2023-12-15

This dataset contains timeseries data of dissolved oxygen (DO) and temperature measurements of the surface water in a wetland at Old Woman Creek Estuarine Research Reserve in Huron, OH. Dissolved oxygen and temperature measurements were made in the overlying water column of wetland to assess how oxygen changed over time with hydrological events. Measurements were collected by a miniDOT Logger. Data was collected over 1.5 years (June 2022 to December 2023). The miniDOT_DO_Temp_DataFile.csv contains the DO and temperature measurements that were collected every 10 minutes. The water levels of the site varied over-time as the wetland flooded and dried. So, sometimes the miniDOT logger would be out of the water column, resulting in high oxygen levels. Depth of the water column was recorded at every in-person site visit. The miniDOT_Depth_DataFile.csv contains the hand-measured surface water depth measurements for comparison to the logger-collected data. Information on the deployment and measurement methods can be found in the miniDOT_InstallationMethods.csv file.

54 ENVIRONMENTAL SCIENCES↗

CARS measurements of temperature and species number density in supersonic combusting flow

A supersonic combustion burner has been probed by coherent anti-Stokes Raman Spectroscopy and the results compared with computational fluid dynamics. Simultaneous measurement of temperature, nitrogen number density and oxygen number density have been acquired throughout the external combustion region. Preliminary calculations have been made on this system to estimate the burner performance. Comparisons of these techniques are included.

Antcliff, Richard R.↗

Fiber Optic Temperature Sensor Using Dual Air- Filled Fabry-Pérot Cavities With Variable Pressure

We present an approach for high temperature measurement using a pair of fiber-optic Fabry–Pérot (FP) cavities filled with gas of identical but variable pressure. One of the FPs (reference FP) is placed in the cold zone with a known temperature. The temperature of the measuring FP can be deduced by the spectral fringe shift vs. pressure of the two FPs. This method does not require measurement of the pressure or the knowledge of the optical properties of the gas. The use of gas as the sensing material and the measurement mechanism also implies long-term stability and eliminates the cross-sensitivity to strain. We fabricated the sensors and tested them for measuring temperature up to 800 °C. Here, the sensor shows good linearity in the range. Long-term test conducted at 800 °C exhibited the stability of the sensor with fluctuations of ≤0.3% over a duration exceeding 100 hours.

42 ENGINEERING↗

Accurate temperature determination from XRD and EXAFS measurements (Full Technical Final Report)

Measuring temperature is of fundamental importance for High Energy Density science (HED), for studying melting, phase transitions and equations of state. However, temperature determination of high pressure and high temperature (0.1-1 eV) condensed matter remains one of the biggest challenges in such experiments. This project used a combination of advanced experimental techniques and state-of-the-art computational methods to construct a framework relating the observed attenuation of X-ray diffraction (XRD) and Extended X-ray Absorption Fine Structure (EXAFS) signals due to thermal fluctuations to the actual temperature achieved in the experiments. This approach was benchmarked against low temperature resistive heating diamond anvil cell (DAC) experiments and cross-validated at higher pressure and temperature by combining the two complementary and independent techniques, diffraction and EXAFS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive microwave measurements of temperature and salinity in coastal zones

Experimental methods and results from the maritime remote sensing (MARSEN) experiments using dual frequency microwave radiometer detecting systems on board aircraft are described. The radiometers were operated at 1.43 and 2.65 GHz and flown above U.S. Atlantic coastal areas, Chesapeake Bay, around Puerto Rico, and over the German Bight. The advanced switched radiometers used were configured to be independent of gain variations and errors originating from front-end losses and determined the absolute brightness temperatures to within a few tenths Kelvin. Corrections to the observed brightness temperature of the ocean are analytically defined, including accounts made for roughness, the cosmic background radiation, and the solar radio source. The coastal flight data for salinity gradients and surface temperatures were compared with sea truth measured from ships and found to be accurate to within 1 C and 1 pph.

Blume, H.-J. C.↗

Evidence for accurate temperatures from the inflatable falling sphere

The experiments performed with the inflatable falling sphere technique, for middle atmosphere studies, are reported. It is shown to be a potentially high accurate and independent source of temperature measurement and an intrinsic method for establishing accuracy of other atmospheric measurement techniques. Theoretical derivation, simulations, and actual measurements show that the sphere's temperature data are accurate. It is demonstrated that retrieved temperatures from falling spheres are not significantly affected by linear bias in density caused by uncertainties in sphere mass, volume, or cross sectional area. Case studies illustrate the sphere's capability to produce accurate temperatures. Comparisons with Datasonde temperature measurements obtained close in time and space are in agreement below 60 km.

Schmidlin, F. J.↗

A real time dynamic data acquisition and processing system for velocity, density, and total temperature fluctuation measurements

The real time Dynamic Data Acquisition and Processing System (DDAPS) is described which provides the capability for the simultaneous measurement of velocity, density, and total temperature fluctuations. The system of hardware and software is described in context of the wind tunnel environment. The DDAPS replaces both a recording mechanism and a separate data processing system. DDAPS receives input from hot wire anemometers. Amplifiers and filters condition the signals with computer controlled modules. The analog signals are simultaneously digitized and digitally recorded on disk. Automatic acquisition collects necessary calibration and environment data. Hot wire sensitivities are generated and applied to the hot wire data to compute fluctuations. The presentation of the raw and processed data is accomplished on demand. The interface to DDAPS is described along with the internal mechanisms of DDAPS. A summary of operations relevant to the use of the DDAPS is also provided.

Clukey, Steven J.↗

Resonance lamp absorption measurement of OH number density and temperature in expansion tube scramjet engine tests

In this paper, we report results of hydroxyl radical and static temperature measurements performed in the General Applied Science Laboratories-NASA HYPULSE expansion tube facility using the microwave resonance lamp absorption technique. Data were obtained as part of a series of hydrogen/air and hydrogen/oxygen combustion tests at stagnation enthalpies corresponding to Mach 17 flight speeds. Data from a representative injector configuration is compared to a full Navier-Stokes CFD solution.

Lempert, Walter R.↗

NCTM of liquids at high temperatures using polarization techniques

Temperature measurement and control is extremely important in any materials processing application. However, conventional techniques for non-contact temperature measurement (mainly optical pyrometry) are very uncertain because of unknown or varying surface emittance. Optical properties like other properties change during processing. A dynamic, in-situ measurement of optical properties including the emittance is required. Intersonics is developing new technologies using polarized laser light scattering to determine surface emittance of freely radiating bodies concurrent with conventional optical pyrometry. These are sufficient to determine the true surface temperature of the target. Intersonics is currently developing a system called DAPP, the Division of Amplitude Polarimetric Pyrometer, that uses polarization information to measure the true thermodynamic temperature of freely radiating objects. This instrument has potential use in materials processing applications in ground and space based equipment. Results of thermophysical and thermodynamic measurements using laser reflection as a temperature measuring tool are presented. The impact of these techniques on thermophysical property measurements at high temperature is discussed.

Krishnan, Shankar↗