Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Design of a digital holography system for PFC erosion measurements on Proto-MPEX

A project has been started at ORNL to develop a dual-wavelength digital holography system for plasma facing component (PFC) erosion measurements on Proto-MPEX. Such a system will allow in-situ real-time measurements of component erosion. Initially the system will be developed with one laser, and first experimental laboratory measurements will be made with the single laser system. In the second year of development a second CO2 laser will be added and measurements with the dual wavelength system will begin. Adding the second wavelength allows measurements at a much longer synthetic wavelength equal to the average of the two wavelengths times the average divided by the difference of the two wavelengths.

plasma diagnostics digital holography↗

Nucleation and Growth of Atmospheric Particles

New particle formation (NPF) in the atmospheric is a two-step process: Nucleation leads to the birth of stable nuclei that subsequently grow to sizes that can be detected and affect the atmosphere’s radiative properties. Our group is studying both of these processes. Our nucleation research is largely supported by NSF and involves measurements of neutral molecular clusters formed by nucleation with a new custom-designed mass spectrometer (the Cluster-CIMS) and measurements of nanoparticle size distributions as small as 1 nm with a new aerosol spectrometer (the DEG SMPS). These measurements are providing new insights into aspects of cluster behavior that affect nucleation rates. The U.S. DOE supports our research on nanoparticle growth rates. This research couples physical and chemical measurements of aerosol properties and behavior. The TDCIMS, which enables real-time measurements of composition for freshly nucleated particles as small as 8 nm and was developed with support from DOE, is the most important tool in this work. Our most important discoveries about processes that affect growth rates are summarized in a recent PNAS article (doi:10.1073/pnas.0912127107). In short, this work has shown that alkylammonium-carboxylate salts, formed, for example, by reactions between amines and carboxylic acids, account for 20–50% of the mass of freshly nucleated particles in locations that include Atlanta, Mexico City, Boulder, and Hyytiälä, while sulfates account for only about 10%. These newly discovered compounds help to explain the high growth rates of freshly nucleated particles that have been observed around the globe and help to explain why nucleation is an important atmospheric process, not just a scientific curiosity. Our poster will provide an overview of this work.

54 ENVIRONMENTAL SCIENCES↗

New calibration techniques for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Recent laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) include new methods for the characterization of the geometric, spectral, temporal and radiometric properties of the sensor. New techniques are desired in order to: (1) increase measurement accuracy and precision, (2) minimize measurement time and expense, (3) prototype new field and inflight calibration systems, (4) resolve measurement ambiguities, and (5) add new measurement dimensions. One of the common features of these new methods is the use of the full data collection and processing power of the AVIRIS instrument and data facility. This allows the collection of large amounts of calibration data in a short period of time and is well suited to modular data analysis routines.

Chrien, Thomas G.↗

Timing Sampler For Delay Measurements

Integrated circuit called timing sampler used to measure delays in complementary metal oxide/silicon logic gates. Circuit chip contains chains of inverters and metal traces having minimum parasitic delays (delay chains), circuits to compare pulse timings, and output multiplexer. Timing sampler enables delay measurements for both positive and negative logic-level transitions by use of variety of circuit geometries representing tentative practical designs.

Blaes, Brent R.↗

Time-of-flight measurements of heavy ions using Si PIN diodes

A new off-line timing method for PIN diode signals is presented which allows the plasma delay effect to be suppressed. Velocities of heavy ions measured by the new method are in good agreement within a wide range of masses and energies with velocities measured by time stamp detectors based on microchannel plates.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-speed quantum-random number generation by continuous measurement of arrival time of photons

We demonstrate a novel high speed and multi-bit optical quantum random number generator by continuously measuring arrival time of photons with a common starting point. To obtain the unbiased and post-processing free random bits, the measured photon arrival time is converted into the sum of integral multiple of a fixed period and a phase time. Theoretical and experimental results show that the phase time is an independent and uniform random variable. A random bit extraction method by encoding the phase time is proposed. An experimental setup has been built and the unbiased random bit generation rate could reach 128 Mb/s, with random bit generation efficiency of 8 bits per detected photon. The random numbers passed all tests in the statistical test suite.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Activation Study of Isotopically Enriched Samples During Neutron Time-of-Flight Measurements

Over the course of a time-of-flight neutron cross section measurement, the sample isotope(s) of interest are irradiated by neutrons and photons. Ideally, the enriched sample will not have any additional radioactivity after the measurement as compared to the baseline detectable radioactivity (0.6 Bq/g) established prior to acquisition of the sample. This document presents the process for estimating the activation of a stable enriched isotope exposed to a mixed photon and neutron source using tools from the SCALE code system developed at Oak Ridge National Laboratory. The report also presents the activation analysis for the isotopes of current interest: 90;91;92;94 Zr. This information is provided for two sets of Zr samples: one set of ZrO 2 samples, and one set of metal Zr samples. It was determined that, following measurements at the GELINA linear accelerator facility, all of the enriched Zr samples would contain less than 0.6 Bq/g of radioactivity within 183 days after irradiation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.

60 APPLIED LIFE SCIENCES↗

Critical and Subcritical Experiment NEA Benchmark Possibilities for Measurements at ORCEF and Other USDOE Facilities

This report documents a wide variety of critical and subcritical measurements that could be Nuclear Energy Agency (NEA) or International Criticality Safety Benchmark Program (ICSBEP) benchmarks. The list has omitted some few measurements. The experiments are divided into four classes: critical experiments only, critical and subsequent subcritical experiments, subcritical experiments (all performed in critical experiment facilities, and fourth subcritical measurements performed in Material Balance Areas at the Y-12 National Security Complex (NSC) for Y-12 nuclear criticality safety. This report documents to number of critical facility days utilized used for the measurements. Measurement at critical and subsequently subcritical in critical facilities at Oak Ridge National Laboratory (ORCEF), Los Alamos National Laboratory, Pacific Northwest National Laboratory, and Babcock and Wilcox at Lynchburg, Va, utilized ~350 operational days of critical facility time, Measurement only at subcritical at ORCEF utilized ~200 operational days in this critical facility, and subcritical measurements in Material Balance Areas of the Y-12 National Security Complex used 350 operational days, many were unattended measurements. In view of the high cost of critical facility time and the limitation of only one facility available for measurements in the United States, it is very cost-effective to mine the existing data to produce benchmarks such as those already in NEA and ICSBEP. For measurements at ORCEF the material descriptions from Y-12 NSC and the accuracy of the configurations should (bases on experience with existing NEA or ICSBEP of ORCEF measurement benchmarks) result in uncertainties in measured k eff values lower than ±0.001 and may be as low as ±0.0002; thus, allowing more accurate comparisons between measurements and calculations and thus more accurate verification of calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid Bismuth Feed System for Electric Propulsion

Operation of Hall thrusters with bismuth propellant has been shown to be a promising path toward high-power, high-performance, long-lifetime electric propulsion for spaceflight missions. For example, the VHITAL project aims td accurately, experimentally assess the performance characteristics of 10 kW-class bismuth-fed Hall thrusters - in order to validate earlier results and resuscitate a promising technology that has been relatively dormant for about two decades. A critical element of these tests will be the precise metering of propellant to the thruster, since performance cannot be accurately assessed without an accurate accounting of mass flow rate. Earlier work used a pre/post-test propellant weighing scheme that did not provide any real-time measurement of mass flow rate while the thruster was firing, and makes subsequent performance calculations difficult. The motivation of the present work was to develop a precision liquid bismuth Propellant Management System (PMS) that provides real-time propellant mass flow rate measurement and control, enabling accurate thruster performance measurements. Additionally, our approach emphasizes the development of new liquid metal flow control components and, hence, will establish a basis for the future development of components for application in spaceflight. The design of various critical components in a bismuth PMS are described - reservoir, electromagnetic pump, hotspot flow sensor, and automated control system. Particular emphasis is given to material selection and high-temperature sealing techniques. Open loop calibration test results are reported, which validate the systems capability to deliver bismuth at mass flow rates ranging from 10 to 100 mg/sec with an uncertainty of less than +/- 5%. Results of integrated vaporizer/liquid PMS tests demonstrate all of the necessary elements of a complete bismuth feed system for electric propulsion.

Markusic, T. E.↗

Multi-Sampling Ionization Chamber (MUSIC) for measurements of fusion reactions with radioactive beams

A detection technique for high-efficiency measurements of fusion reactions with low-intensity radioactive beams was developed. The technique is based on a Multi-Sampling Ionization Chamber (MUSIC) operating as an active target and detection system, where the ionization gas acts as both target and counting gas. In this way, we can sample an excitation function in an energy range determined by the gas pressure, without changing the beam energy. The detector provides internal normalization to the incident beam and drastically reduces the measuring time. In the first experiment we tested the performance of the technique by measuring the 10,13,15 C+ 12 C fusion reactions at energies around the Coulomb barrier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum data gathering

Measurement of a quantum system – the process by which an observer gathers information about it – provides a link between the quantum and classical worlds. The nature of this process is the central issue for attempts to reconcile quantum and classical descriptions of physical processes. Here, we show that the conventional paradigm of quantum measurement is directly responsible for a well-known disparity between the resources required to extract information from quantum and classical systems. We introduce a simple form of quantum data gathering, ‘‘coherent measurement’’, that eliminates this disparity and restores a pleasing symmetry between classical and quantum statistical inference. To illustrate the power of quantum data gathering, we demonstrate that coherent measurements are optimal and strictly more powerful than conventional one-at-a-time measurements for the task of discriminating quantum states, including certain entangled many-body states (e.g., matrix product states).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct Measurement of Ammonia Storage on Passive SCR Systems for Lean Gasoline NOx Reduction Using Radio Frequency Sensing

Lean gasoline engine operation provides clear efficiency benefits relative to conventional stoichiometric combustion approaches. One of the key hurdles to the widespread, practical implementation of lean gasoline combustion remains the challenge of lean NOx control. One of the potential approaches for controlling NOx emission from lean gasoline engines is the so-called passive selective catalytic reduction (SCR) system. In such systems, periods of rich operation generate ammonia over a three-way catalyst (TWC), which is then adsorbed on the downstream SCR and consumed during lean operation. Brief periods of rich operation must occur in response to the depletion of stored ammonia on the SCR, which requires reliable measurements of the SCR ammonia inventory. Presently, lean exhaust system controls rely on a variety of gas sensors mounted up- and downstream of the catalysts, and which only provide an indirect inference of the operation state.In this study, a radio frequency (RF) sensor was used to provide a direction measurement of the amount of ammonia adsorbed on the SCR in real-time. The RF sensor was calibrated and deployed on a BMW N43B20 4-cylinder lean gasoline engine equipped with a passive SCR system. Brief periods of rich operation performed at lambda values between 0.98 and 0.99 generated the ammonia, subsequently stored on the SCR for consumption during periods of lean operation. The experiments compared real-time measurements of SCR ammonia inventory from the RF sensor with estimates of ammonia coverage derived from exhaust gas composition measurements upstream and downstream of the catalyst. The results showed a high degree of correlation between the RF measurements and SCR ammonia storage inventory, and demonstrated NOx conversion efficiencies above 98%, confirming the feasibility of the concept. Relative to stoichiometric operation, lean-gasoline operation resulted in fuel efficiency gains of up to 10%, which may be further improved through direct feedback control from the RF sensor to optimize lean–rich cycling based on actual, measured SCR ammonia levels.

Ragaller, Paul↗

Obtainment of precise experimental data on diffractometers with 2D and point detectors

A measurement method based on the use of diffractometers with a point detector is proposed that makes it possible to reduce the measurement time by a factor of about 2 in comparison with the conventional experiment. Measures are proposed that allow one to increase the measurement precision for diffractometers with a 2D CCD detector. Refinement of the model of independent atoms from the experimental data obtained by these methods is characterized by consistency between the experimental and calculated structure factors at a level of 1-1.5%. A further significant decrease in refinement Rfactors in going to the multipole model indicates that the data precision is sufficient for studying the charge density in crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DME-Propane Blends Ignition Experiments and Modeling for Heavy-Duty Mixing Controlled Compression Engines

A blend of dimethyl ether (DME) and propane (C3H8) is being studied in a shock tube at heavy-duty engine conditions at 110 bar. Due to its intrinsic combustion properties, DME/propane blend can potentially replace diesel in mixing controlled compression ignition engines. A blend of DME/propane can reduce emissions in mixing controlled compression ignition in heavy-duty engines through modifications, which require simulations using a high-fidelity chemical kinetics model that can accurately predict the chemistry of the blend. An essential aspect of testing the chemical kinetics model is doing baseline fundamental chemistry studies on neat DME and propane, which include ignition delay time measurements. In this work, using a high-pressure shock tube, ignition delay times were gathered for DME/Propane blends at 110 bar diluted with AR to test chemical kinetic models published in the literature. These models include Aramco 3.0, NUIG V1.1, C3mech V3.3, and Dames et al. Comparisons with the experimental IDTs and models were conducted, and general agreement was observed. A sensitivity analysis was conducted, and important reactions were outlined.

Mohammed, Zuhayr Pasha [University of Central Flor↗

Current status: Animal models of nausea

The advantages, and possible benefits of a valid, reliable animal model for nausea are discussed, and difficulties inherent to the development of a model are considered. A principle problem for developing models arises because nausea is a subjective sensation that can be identified only in humans. Several putative measures of nausea in animals are considered, with more detailed consideration directed to variation in cardiac rate, levels of vasopressin, and conditioned taste aversion. Demonstration that putative measures are associated with reported nausea in humans is proposed as a requirement for validating measures to be used in animal models. The necessity for a 'real-time' measure of nausea is proposed as an important factor for future research; and the need for improved understanding of the neuroanatomy underlying the emetic syndrome is discussed.

Robert A Fox↗

Is the changing orbital period of EXO 0748-676 evidence for a triple system?

We present eclipse timing measurements of the low-mass X-ray binary (LMxB) EXO 0748-676 made with ASCA. These measurements, when combined with previous results, are consistent with the hypothesis that eclipse times are modulated by a third body. The parameters of the orbit of the postulated third body are now apparently well constrained and will allow further observations to effectively test the hypothesis that EXO 0748-676 is a triple system. The derived orbital parameters are such that, unless the inclination angle is very low, a third body in the system must have a mass less than the lower limit for a main-sequence star.

Corbet, R. H. D.↗

Off-beam (multiply-scattered) lidar returns from stratus: Cloud-information content and sensitivity to noise - 1

We review the basic multiple scattering theory of off-beam lidar returns from optically thick clouds using the diffusion approximation. The shape of the temporal signal - the stretched pulse - depends primarily on the physical thickness of the cloud whereas its spatial counterpart - the diffuse spot - conveys specific information on the cloud's optical thickness, as do the absolute returns. This makes observation of the weak off-beam lidar returns an attractive prospect in remote sensing of cloud properties. By estimating the signal-to-noise ratio, we show that night-time measurements can be performed with existing technology. By the same criterion, day-time operation is a challenge that can only be met with a combination of cutting-edge techniques in filtering and in laser sources.

Davis, Anthony B.↗