Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Design of a Thermal Testbed for Metrology of Active Antennas

NASA mission requirements have driven an increased interest in active phased array antennas (APAA) for space-based user communication terminals. Recent advancements in 5G technology have driven down the cost of APAA development and manufacturing all while providing a technology solution that covers many existing Ka-Band satellite communication spectrum bands. While these developments have provided ample opportunities to leverage new chips and arrays for use in space, there is also a need to evaluate these antennas in a relevant environment. Active arrays, as designed for use in 5G, require thermal management to avoid damage to the device as well as to maintain performance. Measured performance under various thermal conditions is essential both for understanding overall APAA performance and ensuring operation is within required tolerances. To address these measurement needs, the SmallSat Ka-band Operations User Terminal (SKOUT) project at the NASA Glenn Research Center (GRC) developed a test environment that combines traditional antenna and communication system metrology with a conduction cooling/heating thermal control system to simulate the space thermal environment. This paper will address the metrologysystem design and performance specifications as well as test article setup and operation. Tests that are typically performed at ambient temperature can now be performed over the typical temperature range of a Low Earth Orbit (LEO) mission. These tests include error vector magnitude (EVM), gain to noise temperature (G/T), antenna patterns, and non-linear characterization. The paper will cover the configuration for each test and provide results from a recent test campaign. Results illustrate the importance of higher fidelity environmental testing when evaluating the performance of an APAA.

active phased array↗

Cabin Thermal Management Analysis for SuperTruck II Next-Generation Hybrid Electric Truck Design

In this article, we present a multistage, coupled thermal management simulation approach, informed by physical testing where available, to aid design decisions for PACCAR's SuperTruck II hybrid truck cabin concept. Focus areas include cabin insulation, battery sizing, and sleeper curtain position, as well as heating, ventilating, and air-conditioning (HVAC) component and accessory configurations, to maintain or improve thermal comfort while saving energy. The authors analyzed weather data and determined the national vehicle miles traveled weighted temperature and solar conditions for long-haul trucks. Example weather day profiles were selected to approximate the 5th and 95th percentile weighted conditions. A daylong drive cycle was developed to impose appropriate external wind conditions during rest and driving periods. Using the National Renewable Energy Laboratory's vehicle HVAC modeling and simulation tool VTCab, HVAC load design trade-off studies for the new truck geometry concept were completed. Parameters analyzed included effects of paint color, insulation, glass transmissivity, and curtain location. Simulation results helped with early design material selections for efficient cabin climate control. A detailed three-dimensional computer-aided engineering (CAE), computational fluid dynamics (CFD), radiation, and human physiology co-simulation, referred to in this article as CAE Thermal-CFD, was used to evaluate thermal comfort and energy impacts of diffuser configurations and air supply settings in driving and hoteling modes. Analysis revealed that it is more difficult to heat the cabin in hoteling mode during the winter than to cool the space in the summer. This seasonal load profile drives the requirement of additional energy storage for heating comfort. To determine the battery capacity requirement, multiday HVAC operation drive cycle simulations were then completed, showing that a 15-kWh battery would be required for HVAC operation during hoteling. Results helped reduce cabin thermal loads, determine component sizing requirements, and improve occupant comfort to save fuel and contribute to the economic viability of the hybrid system.

33 ADVANCED PROPULSION SYSTEMS↗

THERMAL MODELING ANALYSIS OF CST MEDIA IN THE SMALL COLUMN ION EXCHANGE PROJECT

Models have been developed to simulate the thermal characteristics of Crystalline Silicotitanate (CST) ion exchange media fully loaded with radioactive cesium in a column configuration and distributed within a waste storage tank. This work was conducted to support the Small Column Ion Exchange (SCIX) program which is focused on processing dissolved, high-sodium salt waste for the removal of specific radionuclides (including Cs-137, Sr-90, and actinides) within a High Level Waste (HLW) storage tank at the Savannah River Site. The SCIX design includes CST columns inserted and supported in the tank top risers for cesium removal. Temperature distributions and maximum temperatures across the column were calculated with a focus on process upset conditions. A two-dimensional computational modeling approach for the in-column ion-exchange domain was taken to include conservative, bounding estimates for key parameters such that the results would provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on CST. One salt processing scenario includes the transport of the loaded (and possibly ground) CST media to the treatment tank floor. Therefore, additional thermal modeling calculations were conducted using a three-dimensional approach to evaluate temperature distributions for the entire in-tank domain including distribution of the spent CST media either as a mound or a flat layer on the tank floor. These calculations included mixtures of CST with HLW sludge or loaded Monosodium Titanate (MST) media used for strontium/actinide sorption. The current full-scale design for the CST column includes one central cooling pipe and four outer cooling tubes. Most calculations assumed that the fluid within the column was stagnant (i.e. no buoyancy-induced flow) for a conservative estimate. A primary objective of these calculations was to estimate temperature distributions across packed CST beds immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed (a primary heat transfer mechanism), inadvertent column drainage, and loss of active cooling in the column. The calculation results showed that for a wet CST column with active cooling through one central and four outer tubes and 35 C ambient external air, the peak temperature for the fully-loaded column is about 63 C under the loss of fluid flow accident, which is well below the supernate boiling point. The peak temperature for the naturally-cooled (no active, engineered cooling) wet column is 156 C under fully-loaded conditions, exceeding the 130 C boiling point. Under these conditions, supernate boiling would maintain the column temperature near 130 C until all supernate was vaporized. Without active engineered cooling and assuming a dry column suspended in unventilated air at 35 C, the fully-loaded column is expected to rise to a maximum of about 258 C due to the combined loss-of coolant and column drainage accidents. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. Results for the in-tank modeling calculations clearly indicate that when realistic heat transfer boundary conditions are imposed on the bottom surface of the tank wall, as much as 450 gallons of ground CST (a volume equivalent to two ion exchange processing cycles) in an ideal hemispherical shape (the most conservative geometry) can be placed in the tank without exceeding the 100 C wall temperature limit. Furthermore, in the case of an evenly-distributed flat layer, the tank wall reaches the temperature limit after the ground CST material reaches a height of approximately 8 inches.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aerosol-deep convection interaction based on joint cell-thermal tracking in Large Eddy Simulations during the TRACER campaign

In cumulus clouds, aerosol concentrations control cloud droplet concentrations, modifying cloud radiative properties, precipitation processes, and cloud electrification. However, mechanisms of aerosol-deep convection interactions are not well understood due to complex cloud dynamics and microphysics. We investigate the interaction of aerosols with isolated deep convection using Large Eddy Simulations of two cases during the TRacking Aerosol Convection interactions ExpeRiment (TRACER) near Houston, Texas, using a joint cell-thermal tracking algorithm. Cumulus thermals are droplet generators, since supersaturation and droplet nucleation coincide with thermal centers, where the strongest updrafts occur. Primary ice crystal formation does not take place inside thermals, but at layers where previous thermals detrained moisture. As subsequent thermals containing supercooled droplets penetrate these layers, hail and graupel form at or near these thermals. Higher aerosol concentrations result in higher droplet concentrations that suppress drizzle, delay warm rain processes, and transport more moisture aloft. This increases snow and ice amount, as well as graupel and hail, leading to more lightning. Polluted thermals initiate at slightly higher altitudes, and are slightly larger and faster, suggesting a weak invigoration. We also find more thermals per cell, but fewer isolated cells, since convection is more aggregated and intense, especially near the end of the 24 h simulation. Non-linear mesoscale feedback likely triggered by temperature and moisture responses to aerosol-thermal interactions causes the aggregation. Time-lagged aerosol-reinitialization experiments show that the mesoscale response is the predominant forcing for the invigoration. These changes happen within one day, on a smaller scale than previously suggested.

54 ENVIRONMENTAL SCIENCES↗

Mars: Past, Present, and Future. Results from the MSATT Program, part 1

This volume contains papers that were accepted for presentation at the workshop on Mars: Past, Present, and Future -- Results from the MSATT Program. Topics include, but are not limited to: Martian impact craters; thermal emission measurements of Hawaiian palagonitic soils with implications for Mars; thermal studies of the Martian surface; Martian atmospheric composition studies; temporal and spatial mapping of Mars' atmospheric dust opacity and surface albedo; studies of atmospheric dust from Viking IR thermal mapper data; the distribution of Martian ground ice at other epochs; numerical simulation of thermally induced near-surface flows over Martian terrain; the pH of Mars; the mineralogic evolution of the Martian surface through time; geologic controls of erosion and sedimentation on Mars; and dielectric properties of Mars' surface: proposed measurement on a Mars Lander.

Haberle, R. M.↗

Testing predictions of electron scale turbulent pedestal transport in two DIII-D ELMy H-modes

In this study, we present linear and nonlinear gyrokinetic analyses in the pedestal region of two DIII-D ELMy H-mode discharges using the CGYRO code. The otherwise matched discharges employ different divertor configurations to investigate the impact of varying recycling and particle source on pedestal profiles. Linear gyrokinetic simulations find electrostatic ion-scale instabilities (ion temperature gradient and trapped electron modes, ITG-TEM) are present just inside the top of the pedestal with growth rates that are enhanced significantly by parallel velocity shear. In the sharp gradient region, E x B shearing rates are comparable or larger than ion scale growth rates, suggesting the suppression of ITG-TEM modes in this region. Instead, the electron temperature profiles are found to be correlated with and just above the electron temperature gradient (ETG) instability thresholds. Using gradients varied within experimental uncertainties, nonlinear electron-scale gyrokinetic simulations predict electron heat fluxes from ETG turbulence, that when added to neoclassical ion thermal transport simulated by NEO, account for 30-60% of the total experimental heat flux. In addition, the neoclassical electron particle flux is found to contribute significantly to the experimental fluxes inferred from SOLPS-ITER analysis. Additional nonlinear gyrokinetic simulations are run varying input gradients to develop a threshold-based reduced model for ETG transport, finding a relatively simple dependence on η e = L ne /L Te . Predictive transport simulations are used to validate this pedestal-specific ETG model, in conjunction with a model for neoclassical particle transport. In both discharges, the predicted electron temperatures are always overpredicted, indicative of the insufficient stiffness in the ETG pedestal model to account for all of the experimental electron thermal transport. In the case of the closed divertor discharge with lower particle source, the predicted electron density is close to the experiment, consistent with the magnitude of neoclassical particle transport in that discharge. However, the density profiles are overpredicted in the open divertor discharge (larger particle source), due to insufficient model transport. In conclusion, the implications for other mechanisms accounting for the remainder of transport in the sharp gradient region in the two discharges are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Lifetime Estimate for ACSR Single-Stage Splice Connector Operating at Higher Temperatures

This paper is the continuation of Part I effort to develop a protocol of integrating analytical and experimental approaches to evaluate the integrity of a full tension single-stage splice connector (SSC) assembly during service at high operating temperature.1The Part II efforts are mainly focused on the thermal mechanical testing, thermal-cycling simulation and its impact on the effective lifetime of the SSC system. The investigation indicates that thermal cycling temperature and frequency, conductor cable tension loading, and the compressive residual stress field within a SSC system have significant impact on the SSC integrity and the associated effective lifetime.

43 PARTICLE ACCELERATORS↗

Sedimentary Geothermal Feasibility Study: October 2016

The objective of this project is to analyze the feasibility of commercial geothermal projects using numerical reservoir simulation, considering a sedimentary reservoir with low permeability that requires productivity enhancement. A commercial thermal reservoir simulator (STARS, from Computer Modeling Group, CMG) is used in this work for numerical modeling. In the first stage of this project (FY14), a hypothetical numerical reservoir model was developed, and validated against an analytical solution. The following model parameters were considered to obtain an acceptable match between the numerical and analytical solutions: grid block size, time step and reservoir areal dimensions; the latter related to boundary effects on the numerical solution. Systematic model runs showed that insufficient grid sizing generates numerical dispersion that causes the numerical model to underestimate the thermal breakthrough time compared to the analytic model. As grid sizing is decreased, the model results converge on a solution. Likewise, insufficient reservoir model area introduces boundary effects in the numerical solution that cause the model results to differ from the analytical solution.

15 GEOTHERMAL ENERGY↗

Thermal response of a series- and parallel-connected solar energy storage to multi-day charge sequences

The thermal response of a multi-tank thermal storage was studied under variable charge conditions. Tests were conducted on an experimental apparatus that simulated the thermal charging of the storage system by a solar collector over predetermined (prescribed) daylong periods. The storage was assembled from three standard 270 L hot-water storage tanks each charged through coupled, side-arm, natural convection heat exchangers which were connected in either a series- or parallel-flow configuration. Both energy storage rates and tank temperature profiles were experimentally measured during charge periods representative of two consecutive clear days or combinations of a clear and overcast day. During this time, no draw-offs were conducted. Of particular interest was the effect of rising and falling charge-loop temperatures and collector-loop flow rate on storage tank stratification levels. Results of this study show that the series-connected thermal storage reached high levels of temperature stratification in the storage tanks during periods of rising charge temperatures and also limited destratification during periods of falling charge temperature. This feature is a consequence of the series-connected configuration that allowed sequential stratification to occur in the component tanks and energy to be distributed according to temperature level. This effect was not observed in the parallel charge configuration. A further aspect of the study investigated the effect of increasing charge-loop flow rate on the temperature distribution within the series-connected storage and showed that, at high flow rates, the temperature distributions were found to be similar to those obtained during parallel charging. A disadvantage of both the high-flow series-connected and parallel-connected multi-tank storage is that falling charge-loop temperatures, which normally occur in the afternoon, tend to mix and destratify the storage tanks. (author)

14 SOLAR ENERGY↗

Thermal Properties of Lunar Regolith Simulants

Various high temperature chemical processes have been developed to extract oxygen and metals from lunar regolith. These processes are tested using terrestrial analogues of the regolith. But all practical terrestrial analogs contain H2O and/or OH-, the presence of which has substantial impact on important system behaviors. We have undertaken studies of lunar regolith simulants to determine the limits of the simulants to validate key components for human survivability during sustained presence on the Moon. Differential Thermal Analysis (DTA) yields information on phase transitions and melting temperatures. Thermo-Gravimetric Analysis (TGA) with Fourier Transform Infrared (FTIR) analysis provides information on evolved gas species and their evolution temperature profiles. The DTA and TGA studies included JSC-1A fine (Johnson Space Center Mare Type 1A simulant), NU-LHT-2M (National Aeronautics and Space Administration (NASA)-- United States Geological Survey (USGS)--Lunar Highlands Type 2M simulant) and its proposed feedstocks: anorthosite; dunite; high quality (HQ) glass and the norite from which HQ glass is produced. As an example, the DTA and TGA profiles for anorthosite follow. The DTA indicates exothermic transitions at 355 and 490 C and endothermic transitions at 970 and 1235 C. Below the 355 C transition, water is lost accounting for approximately 0.1 percent mass loss. Just above 490 C a second type of water is lost, presumably bound in lattices of secondary minerals along with other volatile oxides. Limited TGA-FTIR data is available at the time of this writing. For JSC-1A fine, the TGA-FTIR indicates at least two kinds of water are evolved in the 100 to 500 and the 700 to 900 C ranges. Evolution of carbon dioxide types occurs in the 250 to 545, 545 to 705, and 705 to 985 C ranges. Geologically, the results are consistent with the evolution of "water" in its several forms, CO2 from break down of secondary carbonates and magmatic, dissolved gas and glass recrystallization

Street, Kenneth W., Jr.↗

Integration of Hydra-TH in VERA (L2 Milestone THM.CFD.P5.01)

This report describes the work carried out for completion of the Thermal Hydraulics Methods (THM) Level 2 Milestone THM.CFD.P5.01 for the Consortium for Advanced Simulation of Light Water Reactors (CASL). This milestone focused primarily on the initial integration of Hydra-TH in VERA. The primary objective for this milestone was the integration of Hydra-TH as a standalone executable in VERA. A series of code extensions/modifications have been made to Hydra-TH to facilitate integration of Hydra-TH in VERA and to permit future tighter integration and physics coupling. A total of 61 serial and 64 parallel regression tests have been supplied with Hydra-TH. These tests are are being executed in the TriBITS environment. Once the VERA team enables the full suite of tests, the results can be posted to the VERA CDash site. Future work will consider the use of the LIME 2.0 interface for tighter integration in VERA with additional efforts focused on multiphysics coupling with radiation transport, fuel performance, and solid/structural mechanics.

97 MATHEMATICS AND COMPUTING↗

GTRF Calculations Using Hydra-TH (THM.CFD.P5.05) [Slides]

This report describes the work carried out for completion of the Thermal Hydraulics Methods (THM) Level 3 Milestone THM.CFD.P5.05 for the Consortium for Advanced Simulation of Light Water Reactors (CASL). A series body-fitted computational meshes have been generated by Numeca's Hexpress/Hybrid, a.k.a. 'Spider', meshing technology for the V5H 3x3 and 5x5 rod bundle geometry used to compute the fluid dynamics of grid-to-rod fretting (GTRF). Spider is easy to use, fast, and automatically generates high-quality meshes for extremely complex geometries, required for the GTRF problem. Hydra-TH has been used to carry out large-eddy simulations on both 3x3 and 5x5 geometries, using different mesh resolutions. The results analyzed show good agreement with Star-CCM+ simulations and experimental data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GTRF Calculations Using Hydra-TH (L3 Milestone THM.CFD.P5.05)

This report describes the work carried out for completion of the Thermal Hydraulics Methods (THM) Level 3 Milestone THM.CFD.P5.05 for the Consortium for Advanced Simulation of Light Water Reactors (CASL). A series of body-fitted computational meshes have been generated by Numeca's Hexpress/Hybrid, a.k.a. 'Spider', meshing technology for the V5H 3 x 3 and 5 x 5 rod bundle geometries and subsequently used to compute the fluid dynamics of grid-to-rod fretting (GTRF). Spider is easy to use, fast, and automatically generates high-quality meshes for extremely complex geometries, required for the GTRF problem. Hydra-TH has been used to carry out large-eddy simulations on both 3 x 3 and 5 x 5 geometries, using different mesh resolutions. The results analyzed show good agreement with Star-CCM+ simulations and experimental data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Optical Properties of Lunar Dust Simulants and Their Constituents

The total reflectance spectra of lunar simulant dusts (< 20 mm particles) were measured in order to determine their integrated solar absorptance (alpha) and their thermal emittance (epsilon) for the purpose of analyzing the effect of dust on the performance of thermal control surfaces. All of the simulants except one had a wavelength-dependent reflectivity (p (lambda)) near 0.10 over the wavelength range of 8 to 25 microns and so are highly emitting at room temperature and lower. The 300 K emittance (epsilon) of all the lunar simulants except one ranged from 0.78 to 0.92. The exception was Minnesota Lunar Simulant 1 (MLS-1), which has little or no glassy component. In all cases the epsilon was lower for the < 20 micron particles than for larger particles reported earlier. There was considerably more variation in the lunar simulant reflectance in the solar spectral range (250 to 2500 nm) than in the thermal infrared. As expected, the lunar highlands simulants were more reflective in this wavelength range than the lunar mare simulants. The integrated solar absorptance (alpha) of the simulants ranged from 0.39 to 0.75. This is lower than values reported earlier for larger particles of the same simulants (0.41 to 0.82), and for representative mare and highlands lunar soils (0.74 to 0.91). Since the of some mare simulants more closely matched that of highlands lunar soils, it is recommended that and values be the criteria for choosing a simulant for assessing the effects of dust on thermal control surfaces, rather than whether a simulant has been formulated as a highlands or a mare simulant.

Gaier, James R.↗

Classification of machine learning frameworks for data-driven thermal fluid models

Thermal fluid processes are inherently multi-physics and multi-scale, involving mass-momentum-energy transport phenomena at multiple scales. Thermal fluid simulation (TFS) is based on solving conservative equations, for which – except for “first-principles” direct numerical simulation – closure relations (CRs) are required to provide microscopic interactions or so-called sub-grid-scale physics. In practice, TFS is realized through reduced-order modeling, and its CRs as low-fidelity models can be informed by observations and data from relevant and adequately evaluated experiments and high-fidelity simulations. This paper is focused on data-driven TFS models, specifically on their development using machine learning (ML). Five ML frameworks are introduced including physics-separated ML (PSML or Type I ML), physics-evaluated ML (PEML or Type II ML), physics-integrated ML (PIML or Type III ML), physics-recovered (PRML or Type IV ML), and physics-discovered ML (PDML or Type V ML). The frameworks vary in their performance for different applications depending on the level of knowledge of governing physics, source, type, amount and quality of available data for training. Notably, outlined for the first time in this paper, Type III models present stringent requirements on modeling, substantial computing resources for training, and high potential in extracting value from “big data” in thermal fluid research. Here the current paper demonstrates and investigates ML frameworks in three examples. First, we utilize the heat diffusion equation with a nonlinear conductivity model formulated by convolutional neural networks (CNNs) and feedforward neural networks (FNNs) to illustrate the applications of Type I, Type II, Type III, and Type V ML. The results indicate a preference for Type II ML under deficient data support. Type III ML can effectively utilize field data, potentially generating more robust predictions than Type I and Type II ML. CNN-based closures exhibit more predictability than FNN-based closures, but CNN-based closures require more training data to obtain accurate predictions. Second, we illustrate how to employ Type I ML and Type II ML frameworks for data-driven turbulence modeling using reference works. Third, we demonstrate Type I ML by building a deep FNN-based slip closure for two-phase flow modeling. The results show that deep FNN-based closures exhibit a bounded error in the prediction domain.

42 ENGINEERING↗

Convection and lunar thermal history

The effects of solid interior convection on the thermal history of the moon are examined. Convective models of lunar evolution are calculated to demonstrate the influence of various viscosities, radioactive heat source distributions and initial temperature profiles and tested by means of a thermal history simulation code. Results indicate that solid convection does not necessarily produce a quasi-steady thermal balance between heat sources and surface losses. The state of the lithosphere is found to be sensitive to the efficiency of heat source redistribution, while that of the convecting interior depends primarily on rheology. Interior viscosities of 10 to the 21st to 10 to the 22nd cm/sec are obtained, along with a central temperature above 1100 C. It is suggested that mare flooding could have been the result of magma production by pressure release melting in the upwelling region of convection cells.

Cassen, P.↗