Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERAPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

SU-E-T-191: First Principle Calculation of Quantum Yield in Photodynamic Therapy

Purpose: We present a first-principle method to calculate the spin transfer efficiency in oxygen induced by any photon fields especially in MeV energy range. The optical pumping is mediated through photosensitizers, e.g., porphyrin and/or ensemble of quantum dots. Methods: Under normal conditions, oxygen molecules are in the relatively non-reactive triplet state. In the presence of certain photosensitizer compounds such as porphyrins, electromagnetic radiation of specific wavelengths can excite oxygen to highly reactive singlet state. With selective uptake of photosensitizers by certain malignant cells, photon irradiation of phosensitized tumors can lead to selective killing of cancer cells. This is the basis of photodynamic therapy (PDT). Despite several attempts, PDT has not been clinically successful except in limited superficial cancers. Many parameters such as photon energy, conjugation with quantum dots etc. can be potentially combined with PDT in order to extend the role of PDT in cancer management. The key quantity for this optimization is the spin transfer efficiency in oxygen by any photon field. The first principle calculation model presented here, is an attempt to fill this need. We employ stochastic density matrix description of the quantum jumps and the rate equation methods in quantum optics based on Markov/Poisson processes and calculate time evolution of the population of the optically pumped singlet oxygen. Results: The results demonstrate the feasibility of our model in showing the dependence of the optical yield in generating spin-singlet oxygen on the experimental conditions. The adjustable variables can be tuned to maximize the population of the singlet oxygen hence the efficacy of the photodynamic therapy. Conclusion: The present model can be employed to fit and analyze the experimental data and possibly to assist researchers in optimizing the experimental conditions in photodynamic therapy.

60 APPLIED LIFE SCIENCES↗

MO-G-BRF-05: Determining Response to Anti-Angiogenic Therapies with Monte Carlo Tumor Modeling

Purpose: Patient response to anti-angiogenic therapies with vascular endothelial growth factor receptor - tyrosine kinase inhibitors (VEGFR TKIs) is heterogeneous. This study investigates key biological characteristics that drive differences in patient response via Monte Carlo computational modeling capable of simulating tumor response to therapy with VEGFR TKI. Methods: VEGFR TKIs potently block receptors, responsible for promoting angiogenesis in tumors. The model incorporates drug pharmacokinetic and pharmacodynamic properties, as well as patientspecific data of cellular proliferation derived from [18F]FLT-PET data. Sensitivity of tumor response was assessed for multiple parameters, including initial partial oxygen tension (pO{sub 2}), cell cycle time, daily vascular growth fraction, and daily vascular regression fraction. Results were benchmarked to clinical data (patient 2 weeks on VEGFR TKI, followed by 1-week drug holiday). The tumor pO{sub 2} was assumed to be uniform. Results: Among the investigated parameters, the simulated proliferation was most sensitive to the initial tumor pO{sub 2}. Initial change of 5 mmHg can already Result in significantly different levels of proliferation. The model reveals that hypoxic tumors (pO{sub 2} ≥ 20 mmHg) show the highest decrease of proliferation, experiencing mean FLT standardized uptake value (SUVmean) decrease for at least 50% at the end of the clinical trial (day 21). Oxygenated tumors (pO{sub 2} 20 mmHg) show a transient SUV decrease (30–50%) at the end of the treatment with VEGFR TKI (day 14) but experience a rapid SUV rebound close to the pre-treatment SUV levels (70–110%) at the time of a drug holiday (day 14–21) - the phenomenon known as a proliferative flare. Conclusion: Model's high sensitivity to initial pO{sub 2} clearly emphasizes the need for experimental assessment of the pretreatment tumor hypoxia status, as it might be predictive of response to antiangiogenic therapies and the occurrence of proliferative flare. Experimental assessment of other model parameters would further improve understanding of patient response.

60 APPLIED LIFE SCIENCES↗

TH-C-17A-05: Cherenkov Excited Phosphorescence Oxygen (CEPhOx) Imaging During Multi-Beam Radiation Therapy

Purpose: Cherenkov radiation is created during external beam radiation therapy that can excite phosphorescence in tissue from oxygen-sensitive, bio-compatible probes. Utilizing the known spatial information of the treatment plan with directed multiple beam angles, Cherenkov Excited Phosphorescence Oxygen (CEPhOx) imaging was realized from the reconstructions of Cherenkov excited phosphorescence lifetime. Methods: Platinum(II)-G4 (PtG4) was used as the oxygen-sensitive phosphorescent probe and added to a oxygenated cylindrical liquid phantom with a oxygenated/deoxygenated cylindrical anomaly. Cherenkov excited phosphorescence was imaged using a time-gated ICCD camera temporallysynchronized to the LINAC pulse output. Lifetime reconstruction was carried out in NIRFAST software. Multiple angles of the incident radiation beam was combined with the location of the prescribed treatment volume (PTV) to improve the tomographic recovery as a function of location. The tissue partial pressure of oxygen (pO2) in the background and PTV was calculated based on the recovered lifetime distribution and Stern-Volmer equation. Additionally a simulation study was performed to examine the accuracy of this technique in the setting of a human brain tumor. Results: Region-based pO2 values in the oxygenated background and oxygenated/deoxygenated PTV were correctly recovered, with the deoxygenated anomaly (15.4 mmHg) easily distinguished from the oxygenated background (143 mmHg). The data acquisition time could be achieved within the normal irradiation time for a human fractionated plan. The simulations indicated that CEPhOx would be a sufficient to sample tumor pO2 sensing from tumors which are larger than 2cm in diameter or within 23mm depth from the surface. Conclusion: CEPhOx could be a novel imaging tool for pO2 assessment during external radiation beam therapy. It is minimally invasive and should work within the established treatment plan of radiation therapy with multiple beams in situations where tumor pO2 measurement is a pertinent radiotherapy efficiency and dosimetric need.

07 ISOTOPE AND RADIATION SOURCES↗

A scintillator-based approach to monitor secondary neutron production during proton therapy

Here, the primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response for comparison to the measured data. Comparison of the measured and simulated data will validate this approach for monitoring secondary neutron dose during proton therapy. Proton beams of 155- and 200-MeV were used to irradiate a variety of phantom materials and secondary particles were detected using organic liquid scintillators. These detectors are sensitive to fast neutrons and gamma rays: pulse shape discrimination was used to classify each detected pulse as either a neutron or a gamma ray. The mcnpx-PoliMi code was used to simulate the secondary neutron field produced during proton irradiation of the same tissue-equivalent phantom materials. As a result, an experiment was performed at the Loma Linda University Medical Center proton therapy research beam line and corresponding models were created using the mcnpx-PoliMi code. The authors’ analysis showed agreement between the simulations and the measurements. The simulated detector response can be used to validate the simulations of neutron and gamma doses on a particular beam line with or without a phantom. In conclusion, the authors have demonstrated a method of monitoring the neutron component of the secondary radiation field produced by therapeutic protons. The method relies on direct detection of secondary neutrons and gamma rays using organic scintillation detectors. These detectors are sensitive over the full range of biologically relevant neutron energies above 0.5 MeV and allow effective discrimination between neutron and photon dose. Because the detector system is portable, the described system could be used in the future to evaluate secondary neutron and gamma doses on various clinical beam lines for commissioning and prospective data collection in pediatric patients treated with proton therapy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

KiT-RT: An Extendable Framework for Radiative Transfer and Therapy

Here, in this article, we present Kinetic Transport Solver for Radiation Therapy (KiT-RT), an open-source C++-based framework for solving kinetic equations in therapy applications available at https://github.com/CSMMLab/KiT-RT . This software framework aims to provide a collection of classical deterministic solvers for unstructured meshes that allow for easy extendability. Therefore, KiT-RT is a convenient base to test new numerical methods in various applications and compare them against conventional solvers. The implementation includes spherical harmonics, minimal entropy, neural minimal entropy, and discrete ordinates methods. Solution characteristics and efficiency are presented through several test cases ranging from radiation transport to electron radiation therapy. Due to the variety of included numerical methods and easy extendability, the presented open-source code is attractive for both developers, who want a basis to build their numerical solvers, and users or application engineers, who want to gain experimental insights without directly interfering with the codebase.

97 MATHEMATICS AND COMPUTING↗

Epigenetic biomarker screening by FLIM-FRET for combination therapy in ER+ breast cancer

Hormone-dependent gene expression involves dynamic and orchestrated regulation of epigenome leading to a cancerous state. Estrogen receptor (ER)-positive breast cancer rely on chromatin remodeling and association with epigenetic factors in inducing ER-dependent oncogenesis and thus cell over-proliferation. The mechanistic differences between epigenetic regulation and hormone signaling provide an avenue for combination therapy of ER-positive breast cancer. We hypothesized that epigenetic biomarkers within single nucleosome proximity of ER-dependent genes could serve as potential therapeutic targets. We described here a Fluorescence lifetime imaging-based Förster resonance energy transfer (FLIM-FRET) methodology for biomarker screening that could facilitate combination therapy based on our study. We screened 11 epigenetic-related markers which include oxidative forms of DNA methylation, histone modifications, and methyl-binding domain proteins. Among them, we identified H4K12acetylation (H4K12ac) and H3K27 acetylation (H3K27ac) as potential epigenetic therapeutic targets. When histone acetyltransferase inhibitor targeting H4K12ac and H3K27ac was combined with tamoxifen, an enhanced therapeutic outcome was observed against ER-positive breast cancer both in vitro and in vivo. Together, we demonstrate a single molecule approach as an effective screening tool for devising targeted epigenetic therapy.

59 BASIC BIOLOGICAL SCIENCES↗

The Prognostic Value of a Pathologic Complete Response After Neoadjuvant Therapy for Digestive Cancer: Systematic Review and Meta-Analysis of 21 Studies

Background: Neoadjuvant therapy (NAT) before radical excision has become the preferred initial option for locally advanced digestive cancers such as esophageal cancer (EC), esophagogastric junction adenocarcinoma (EGJAC), gastric adenocarcinoma (GAC), rectal cancer (RC), and pancreatic cancer (PC). Although some patients reportedly achieve a pathologic complete response (pCR) after neoadjuvant therapy, the published data are inconsistent regarding whether pCR yields a survival benefit. The current meta-analysis was performed to assess the potential prognostic value of pCR after preoperative therapy for patients with digestive cancers. Methods: An extensive electronic search in PubMed, Web of Science, and the Cochrane Library was performed for relevant articles, from which data relative to independent correlations of pCR with overall survival (OS) and disease-free survival (DFS) were extracted for analysis. A random-effects model was used to calculate the pooled hazard ratios (HRs) with their corresponding 95% confidence intervals (CIs). Results: The study identified 6780 patients who met the inclusion and exclusion criteria. The results showed that pCR was significantly correlated with better OS (HR, 0.50; 95% CI, 0.43–0.58; P < 0.001) and DFS (HR, 0.49; 95% CI, 0.40–0.60; P < 0.001) for the digestive cancer patients who achieved pCR than for those who did not achieve pCR. Subgroup analysis showed that the correlation of pCR with OS was significant in EC (HR, 0.57; 95% CI, 0.47–0.69; P < 0.001), EGJAC/GAC (HR, 0.38; 95% CI, 0.17–0.86; P = 0.02), RC (HR, 0.48; 95% CI, 0.28–0.81; P = 0.006), and PC (HR, 0.41; 95% CI, 0.17–0.97; P = 0.04). In addition, the survival benefit for pCR patients was of similar magnitude, irrespective of the type of study, type of NAT, or ethnicity. Conclusions: A pCR is correlated with favorable survival outcomes compared with a non-pCR for digestive cancer patients after NAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Significance of {sup 18}F-Fluorodeoxyglucose-Positron Emission Tomography-Positive Lymph Nodes to Outcomes of Trimodal Therapy for Esophageal Squamous Cell Carcinoma

Background: The clinical significance of lymph node (LN) status determined by preoperative {sup 18}F-fluorodeoxyglucose-positron emission tomography (FDG-PET) has not been investigated in patients with locally advanced esophageal squamous cell carcinoma (ESCC) treated with neoadjuvant chemoradiotherapy (NCRT) followed by surgery (trimodal therapy). Methods: This study reviewed 132 consecutive patients with ESCC who had been preoperatively evaluated using FDG-PET before and after NCRT to analyze associations among LN status according to PET findings, pathologic LN metastasis, and prognosis of ESCC after trimodal therapy. Results: Lymph nodes that were PET-positive both before and after NCRT comprised significant predictive markers of pathologic LN metastasis in station-by-station analyses (sensitivity, specificity, and accuracy respectively 41.7%, 95.0%, and 92.7% before, and 12.0%, 99.4%, and 95.6% after NCRT; both p < 0.0001). The numbers of LNs evaluated using PET before and after NCRT were significantly associated with those of pathologic metastatic LNs. Uni- and multivariable analyses selected LN status determined by PET before NCRT as a significant independent predictor of both recurrence-free [LN-negative vs LN-positive: hazard ratio (HR) 1.90; 95% confidence interval (CI) 1.02–3.23; p = 0.045] and overall survival (HR 2.62; 95% CI 1.29–5.30; p = 0.01). Conclusions: The status of LN determined by preoperative FDG-PET is significantly associated with pathologic LN status and the prognosis of ESCC with trimodal therapy. Thus, FDG-PET is a useful diagnostic tool for preoperative prediction of pathologic LN metastasis and survival among patients with ESCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards modeling phage therapy

Patients infected with life-threatening multi-drug resistant (MDR) bacteria have been treated with cocktails of bacteriophages. This is a complicated form of personalized medicine as the phages given to a patient have to be selected beforehand on the basis of their lytic capacity of the infecting bacteria. Because bacteria rapidly become resistant, the evolution of resistance to a diverse cocktail of phages is a complicated dynamical process, during which competing bacterial strains replace one another by accumulating several resistance mechanisms, each of which may involve a fitness cost. As a consequence, it is typically not known why a particular phage therapy succeeded or failed, and how one can optimize the composition of the cocktails to maximize the rate of success. To improve upon this, we extend an existing in vivo -calibrated mouse model into a novel mathematical model for the human situation, and include multiple phages infecting multiple bacterial strains, differing in their resistance to each of the phages. We adjust several parameter estimates of the bacterial model to the human situation, and use the model to describe a successful case of phage therapy involving several cocktails, each containing several phages. In the model, treatment success crucially depended on pretreatment resistance levels, and on the diversity and the timing of the cocktails. Once an appropriate cocktail is found, it is less important to further optimize the infection rates of the phages. Resistant bacterial strains expand rapidly when sensitive strains decline, and the higher the infectivity of the phages, the faster resistant strains expand. Because resistance evolves rapidly, it is best to provide a diverse set of phages right from the start of therapy, i.e., to hit hard and early, and create a high genetic barrier to bacterial resistance.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding early HIV-1 rebound dynamics following antiretroviral therapy interruption: The importance of effector cell expansion

Most people living with HIV-1 experience rapid viral rebound once antiretroviral therapy is interrupted; however, a small fraction remain in viral remission for an extended duration. Understanding the factors that determine whether viral rebound is likely after treatment interruption can enable the development of optimal treatment regimens and therapeutic interventions to potentially achieve a functional cure for HIV-1. We built upon the theoretical framework proposed by Conway and Perelson to construct dynamic models of virus-immune interactions to study factors that influence viral rebound dynamics. We evaluated these models using viral load data from 24 individuals following antiretroviral therapy interruption. The best-performing model accurately captures the heterogeneity of viral dynamics and highlights the importance of the effector cell expansion rate. Our results show that post-treatment controllers and non-controllers can be distinguished based on the effector cell expansion rate in our models. Furthermore, these results demonstrate the potential of using dynamic models incorporating an effector cell response to understand early viral rebound dynamics post-antiretroviral therapy interruption.

60 APPLIED LIFE SCIENCES↗

Spatial and Temporal Measurements of Temperature and Cell Viability in Response to Nanoparticle Mediated Photothermal Therapy

Aim: Nanoparticle enhanced photothermal therapy is a promising alternative to tumor resection. However, quantitative measurements of cellular response to these treatments are limited. This paper introduces a Bimodal Enhanced Analysis of Spatiotemporal Temperature (BEAST) algorithm to rapidly determine the viability of cancer cells in vitro following photothermal therapy alone or in combination with nanoparticles. Materials & Methods: To illustrate the capability of the BEAST viability algorithm, single wall carbon nanohorns were added to renal cancer (RENCA) cells in vitro and time-dependent spatial temperature maps measured with an infrared camera during laser therapy were correlated with post-treatment cell viability distribution maps obtained by cell-staining fluorescent microscopy. Conclusion: The BEAST viability algorithm accurately and rapidly determined the cell viability as function of time, space, and temperature.

laser↗

Incidence and predictors of loss to follow-up among adult patients receiving antiretroviral therapy in Central Ethiopia: a multi-center retrospective cohort study

Background: Globally, loss to follow-up (LTFU) remains a significant public health concern despite the rapid expansion of antiretroviral medication programs. It is a significant cause of treatment failure and threatens the enhancement of HIV treatment outcomes among patients on antiretroviral therapy (ART). However, there is a paucity of evidence on its incidence and predictors in Ethiopia. Thus, this study aimed to examine the incidence and predictors of LTFU among adult HIV patients receiving ART at hospitals in Central Ethiopia. Methods: A multi-centered facility-based retrospective cohort study was conducted among 432 randomly selected adult patients who received antiretroviral therapy. Data were entered into EpiData version 3.1 and exported to Stata version 14 for analysis. The Kaplan–Meier failure function was employed to determine the overall failure estimates, and the log-rank test was used to compare the probability of failure among the different categories of variables. The Cox proportional hazard model was used to identify independent predictors of LTFU. Results: Overall, 172 (39.8%) study participants were lost to follow-up over the 10-year follow-up period with an incidence rate of 8.12 (95% CI: 7.11, 9.09) per 1,000 person-months. Undisclosed HIV status (AHR: 1.96, 95% CI: 1.14, 3.36), not able to work (AHR: 1.84, 95% CI: 1.13, 2.22), opportunistic infections (AHR: 3.13, 95% CI: 2.17, 4.52), CD4 < 200 cell/mL (AHR: 1.95, 95% CI: 1.18, 3.21), not receiving isoniazid preventive therapy (IPT) (AHR: 2.57, 95% CI: 1.62, 4.06), not participating in clubs (AHR: 1.68, 95% CI: 1.10, 2.22), side effects of drugs (AHR: 1.44, 95% CI: 1.02, 2.04), and high viral load (AHR: 3.15, 95% CI: 1.81, 5.47) were identified as significant predictors of loss to follow-up. Conclusion: In this study, the incidence of LTFU was high. The focus should be on creating awareness and prevention programs that aim to reduce loss to follow-up by continuing counseling, especially on the negative effects of loss to follow-up and the benefits of ART care.

60 APPLIED LIFE SCIENCES↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Heavy Ion Minibeam Therapy: Side Effects in Normal Brain

The purpose of this work was to investigate whether minibeam therapy with heavy ions might offer improvements of the therapeutic ratio for the treatment of human brain cancers. To assess neurotoxicity, we irradiated normal juvenile rats using 120 MeV lithium-7 ions at an absorbed integral dose of 20 Gy. Beams were configured either as a solid parallel circular beam or as an array of planar parallel minibeams having 300-micron width and 1-mm center-to-center spacing within a circular array. We followed animals for 6 months after treatment and utilized behavioral testing and immunohistochemical studies to investigate the resulting cognitive impairment and chronic pathologic changes. We found both solid-beam therapy and minibeam therapy to result in cognitive impairment compared with sham controls, with no apparent reduction in neurotoxicity using heavy ion minibeams instead of solid beams under the conditions of this study.

60 APPLIED LIFE SCIENCES↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources. Applications of the DWA accelerator to problems in homeland security will also be discussed.

43 PARTICLE ACCELERATORS↗

Preliminary investigations of Monte Carlo Simulations of neutron energy and LET spectra for fast neutron therapy facilities

No fast neutron therapy facility has been built with optimized beam quality based on a thorough understanding of the neutron spectrum and its resulting biological effectiveness. A study has been initiated to provide the information necessary for such an optimization. Monte Carlo studies will be used to simulate neutron energy spectra and LET spectra. These studies will be bench-marked with data taken at existing fast neutron therapy facilities. Results will also be compared with radiobiological studies to further support beam quality ptimization. These simulations, anchored by this data, will then be used to determine what parameters might be optimized to take full advantage of the unique LET properties of fast neutron beams. This paper will present preliminary work in generating energy and LET spectra for the Fermilab fast neutron therapy facility.

43 PARTICLE ACCELERATORS↗

Update on the Innovative Carbon/Proton Non-Scaling FFAG Isocentric gantries for Cancer Therapy

There is a dramatic increase in numbers of proton/carbon cancer therapy facilities in recent years due to a clear advantage with respect to the other radiation therapy treatments. Cost of the ion cancer therapy is still to high for most of the hospitals and a dominating part comes from the delivery systems. We had previously presented design of the carbon and proton isocentric gantries using the principle of the non-scaling alternating gradient fixed field magnets (NS-FFAG), where a size and weight of the magnets should be dramatically reduced. The weight of the transport elements of the carbon isocentric gantry is estimated to be 1.5 tons compared to the 130 tons a weight of the Heidelberg gantry. The similar claim of 500 kg comes for the transport elements of the proton permanent magnet gantry. We present an update on these designs.

43 PARTICLE ACCELERATORS↗