Design, construction and evaluation of a 12.2 GHz, 4.0 kW-CW high efficiency klystron amplifier

An analytical and experimental program is described, for studying design techniques for optimizing the conversion efficiency of klystron amplifiers, and to utilize these techniques in the development and fabrication of an X-band 4 kW cw klystron, for use in satellite-borne television broadcast transmitters. The design is based on a technique for increasing the RF beam current by using the second harmonic space charge forces in the bunched beam. Experimental analysis was also made of a method to enhance circuit efficiency in the klystron cavities. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments employing an axisymmetric, electrostatic collector for linear beam microwave tubes.

Vishida, J. M.↗

Development of an image converter of radical design

A long term investigation of thin film sensors, monolithic photo-field effect transistors, and epitaxially diffused phototransistors and photodiodes to meet requirements to produce acceptable all solid state, electronically scanned imaging system, led to the production of an advanced engineering model camera which employs a 200,000 element phototransistor array (organized in a matrix of 400 rows by 500 columns) to secure resolution comparable to commercial television. The full investigation is described for the period July 1962 through July 1972, and covers the following broad topics in detail: (1) sensor monoliths; (2) fabrication technology; (3) functional theory; (4) system methodology; and (5) deployment profile. A summary of the work and conclusions are given, along with extensive schematic diagrams of the final solid state imaging system product.

Irwin, E. L.↗

Program on application of communications satellites to educational development: Design of a 12 channel FM microwave receiver

The design, fabrication, and performance of elements of a low cost FM microwave satellite ground station receiver is described. It is capable of accepting 12 contiguous color television equivalent bandwidth channels in the 11.72 to 12.2 GHz band. Each channel is 40 MHz wide and incorporates a 4 MHz guard band. The modulation format is wideband FM and the channels are frequency division multiplexed. Twelve independent CATV compatible baseband outputs are provided. The overall system specifications are first discussed, then consideration is given to the receiver subsystems and the signal branching network.

Risch, C. O.↗

Design of a 12 channel fm microwave receiver

The design, fabrication, and performance of elements of a low cost FM microwave satellite ground station receiver is described. It is capable of accepting 12 contiguous color television equivalent bandwidth channels in the 11.72 to 12.2 GHz band. Each channel is 40 MHz wide and incorporates a 4 MHz guard band. The modulation format is wideband FM and the channels are frequency division multiplexed. Twelve independent CATV compatible baseband outputs are provided. The overall system specifications are first discussed, then consideration is given to the receiver subsystems and the signal branching network.

Risch, C. O.↗

Space processing applications payload equipment study. Volume 2C: Data acquisition and process control

The services provided by the Spacelab Information Management System are discussed. The majority of the services are provided by the common-support subsystems in the Support Module furnished by the Spacelab manufacturer. The information processing requirements for the space processing applications (SPA) are identified. The requirements and capabilities for electric power, display and control panels, recording and telemetry, intercom, and closed circuit television are analyzed.

Kayton, M.↗

Lunar soil grain size distribution

A comprehensive review has been made of the currently available data for lunar grain size distributions. It has been concluded that there is little or no statistical difference among the large majority of the soil samples from the Apollo 11, 12, 14, and 15 missions. The grain size distribution for these soils has reached a steady state in which the comminution processes are balanced by the aggregation processes. The median particle size for the steady-state soil is 40 to 130 microns. The predictions of lunar grain size distributions based on the Surveyor television photographs have been found to be quantitatively in error and qualitatively misleading.

Carrier, W. D., III↗

High resolution multispectral camera system for ERTS A & B

A very high resolution multispectral television camera system has been developed for NASA for use on the Earth Resources Technology Satellite (ERTS) program. There are three cameras in the system, each viewing the same area but operating in the blue-green, red, and near-infrared spectral bands. In the laboratory the cameras' limiting resolution is 4500 TV lines over the 25 x 25-mm image format of the Return Beam Vidicon (RBV). Analysis of typical ERTS scenes shows that actual contrast ratios will be much lower than those of laboratory test targets. A model was developed to predict the resolving power performance of the RBV camera under realistic conditions. To verify the model, tests were conducted using the RBV camera, a laser-beam image reproducer and a series of AF tribar test patterns of known values of contrast. As a more graphic demonstration, simulated multispectral images were generated using color-IR photographs from Apollo 9. The measured signal-to-noise, resolution, and spectral characteristics of the ERTS Flight A and Flight B three-camera systems are presented in conclusion.

Miller, B. P.↗

Encke flyby science package

Cometary exploration objectives are considered, giving attention to reasons for the selection of Encke as a target for early exploration missions. An Encke environmental model is discussed together with the scientific requirements of an exploratory mission, instrument selection criteria, and the science payload. The instruments to be used include a television camera, an IR radiometer, a UV spectrometer, a mass spectrometer, a Sisyphus dust detector, devices for the measurement of the EM field, and instruments for the determination of plasma characteristics. It is pointed out that solar electric propulsion affords the only practical, currently available means of reaching Encke with the desired encounter velocity below 7.5 km/sec.

Newburn, R. L.↗

Terminal navigation analysis for the 1980 comet Encke slow flyby mission

The initial results of a terminal navigation analysis for the proposed 1980 solar electric slow flyby mission to the comet Encke are presented. The navigation technique employs onboard optical measurements with the scientific television camera, groundbased observations of the spacecraft and comet, and groundbased orbit determination and thrust vector update computation. The knowledge and delivery accuracies of the spacecraft are evaluated as a function of the important parameters affecting the terminal navigation. These include optical measurement accuracy, thruster noise level, duration of the planned terminal coast period, comet ephemeris uncertainty, guidance initiation time, guidance update frequency, and optical data rate.

Jacobson, R. A.↗

Advance techniques for monitoring human tolerance to positive Gz accelerations

Tolerance to positive g accelerations was measured in ten normal male subjects using both standard and advanced techniques. In addition to routine electrocardiogram, heart rate, respiratory rate, and infrared television, monitoring techniques during acceleration exposure included measurement of peripheral vision loss, noninvasive temporal, brachial, and/or radial arterial blood flow, and automatic measurement of indirect systolic and diastolic blood pressure at 60-sec intervals. Although brachial and radial arterial flow measurements reflected significant cardiovascular changes during and after acceleration, they were inconsistent indices of the onset of grayout or blackout. Temporal arterial blood flow, however, showed a high correlation with subjective peripheral light loss.

Pelligra, R.↗

Distribution pattern of temperature and biomass in the upwelling area along the NW coast of Africa

Atmospheric conditions and wind systems are considered together with temperature observations. Data from scanning radiometers in the infrared and television cameras for the visible were applied to derive temperature data over cloudfree regions. From the analyzed spacecraft data it is obvious that the distribution of temperature and nonconservative parameters is much more complicated than one might expect from conventional measurements onboard a ship.

Szekielda, K.-H.↗

Mariner 9 photometric observations of Mars from November 1971 through March 1972

The large quantity of Mariner 9 television pictures taken at phase angles ranging up to twice those accessible from earth has been used to describe integrated photometric properties of Mars. Although frame-to-frame variations emphasize the shortcomings of vidicon cameras when used in a photometric mode, statistical trends have yielded data comparable with earth-based observations. Analysis of atmospheric parameters over a period of changing opacity - November 1971 through March 1972 - has provided time-varying optical depths and light-scattering information. Linear function characterization of the Mars reflectance is clearly discrepant at large incidence or emission angles and at phase angles greater than 40 deg.

Thorpe, T. E.↗

Mariner 10 Venus encounter

Review of the scientific objectives of the Mariner 10 mission with regard to observations of Venus during a flyby, and description of the equipment installed on the spacecraft to fulfill these objectives. A detailed description is given of the hardware modifications made to the payload specifically for the Venus sequence. In discussing the encounter operations, two spacecraft problems which significantly affected the Venus encounter sequence are cited - namely, a failure of the television optic heaters to come on shortly after launch, and the occurrence of a roll gyro oscillation.

Dunne, J. A.↗

Venus - Atmospheric motion and structure from Mariner 10 pictures

The Mariner 10 television cameras imaged the planet Venus in the visible and near ultraviolet for a period of 8 days at resolutions ranging from 100 meters to 130 kilometers. The general pattern of the atmospheric circulation in the upper tropospheric/lower stratospheric region is displayed in the pictures. Atmospheric flow is symmetrical between north and south hemispheres. The equatorial motions are zonal (east-west) at approximately 100 meters per second, consistent with the previously inferred 4-day retrograde rotation. Angular velocity increases with latitude. The subsolar region, and the region downwind from it, show evidence of large-scale convection that persists in spite of the main zonal motion. Dynamical interaction between the zonal motion and the relatively stationary region of convection is evidenced by bowlike waves.

Murray, B. C.↗

Low-altitude acceleration of auroral electrons during breakup observed by a mother-daughter rocket

By the use of a mother-daughter rocket combination and ground-based observations with television, time and space variations are resolved in particle measurements in breakup aurora. The spectral variations measured during a temporal variation in the aurora can be explained by a nearly uniform acceleration of all the electrons such as would be caused by an electric potential drop along the magnetic field lines. Many other explanations can be eliminated.

Johnstone, A. D.↗

Video systems for real-time oil-spill detection

Three airborne television systems are being developed to evaluate techniques for oil-spill surveillance. These include a conventional TV camera, two cameras operating in a subtractive mode, and a field-sequential camera. False-color enhancement and wavelength and polarization filtering are also employed. The first of a series of flight tests indicates that an appropriately filtered conventional TV camera is a relatively inexpensive method of improving contrast between oil and water. False-color enhancement improves the contrast, but the problem caused by sun glint now limits the application to overcast days. Future effort will be aimed toward a one-camera system. Solving the sun-glint problem and developing the field-sequential camera into an operable system offers potential for color 'flagging' oil on water.

Millard, J. P.↗

Photogrammetric measurements of Olympus Mons on Mars

Mariner 9 took many pictures of the giant Olympus Mons during its year in orbit around Mars. Control points have been identified on the top of Olympus Mons, on the volcanic shield, and on the surrounding plains, and their locations have been measured on the television pictures. These measurements were used to compute the areographic coordinates and the planetary radii of the points. The radii at some of the points were derived from radar elevation measurements and from radio occultation measurements. The mountain rises about 21 km above its base.

Davies, M. E.↗

Chaotic terrain of Mars - A tectonic interpretation from Mariner 6 imagery

Sharp et al. (1971) define chaotic terrain as an irregular jumble of topographic forms covering a certain area within Pyrrhae Regio and adjacent regions centered at about 10 deg S., 35 deg W. This area is covered by Mariner 6 television imagery. An analysis of fracture patterns in the Martian surface from high-resolution Mariner 6 imagery suggests that the lineaments observed in both the chaotic terrain and the cratered plateau areas in Pyrrhae Regio are tectonic fractures resulting from stresses within the Martian crust.