Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TARGET SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A METHOD TO EXTRACT THE ANGULAR POWER SPECTRUM OF THE EPOCH OF REIONIZATION FROM LOW-FREQUENCY RADIO INTERFEROMETERS

The redshifted 21 cm signal of neutral hydrogen from the epoch of reionization (EoR) is extremely weak and its first detection is therefore expected to be statistical with first-generation low-frequency radio interferometers. In this Letter, we propose a method to extract the angular power spectrum of the EoR from the visibility correlation coefficients p{sub ij} (u, v), instead of the visibilities V{sub ij} (u, v) measured directly by radio interferometers in conventional algorithm. The visibility correlation coefficients are defined as p{sub ij}(u,v)=V{sub ij}(u,v)/{radical}(|V{sub ii}||V{sub jj}|) by introducing the autocorrelation terms V{sub ii} and V{sub jj} such that the angular power spectrum C{sub l} can be obtained through C{sub l} = T {sup 2}{sub 0}(|p{sub ij} (u, v)|{sup 2}), independently of the primary beams of antennas. This also partially removes the influence of receiver gains in the measurement of C{sub l} because the amplitudes of the gains cancel each other out in the statistical average operation of (|p{sub ij} (u, v)|{sup 2}). We use the average system temperature T{sub 0} as a calibrator of C{sub l}, which is dominated by the Milky Way and extragalactic sources in the frequency range that we are interested in, below 200 MHz. Finally, we demonstrate the feasibility of this novel method using the simulated sky maps as targets and the 21 CentiMeter Array (21CMA) as interferometer.

79 ASTRONOMY AND ASTROPHYSICS↗

Primordial non-Gaussianity from the completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey II: measurements in Fourier space with optimal weights

ABSTRACT We present measurements of the local primordial non-Gaussianity parameter $f_{\mathrm{NL}}^\mathrm{local} $from the clustering of 343 708 quasars with redshifts 0.8 < z < 2.2 distributed over 4808 deg2 from the final data release (DR16) of the extended Baryon Acoustic Oscillation Spectroscopic Survey (eBOSS), the largest volume spectroscopic survey up to date. Our analysis is performed in Fourier space, using the power spectrum monopole at very large scales to constrain the scale-dependent halo bias. We demonstrate the robustness of our analysis pipeline with EZ-mock catalogues that simulate the eBOSS DR16 target selection. We carefully assess the impact of systematics on our measurement, exploiting a novel neural network scheme for cleaning the DR16 sample as well as test multiple contamination removal methods. We estimate the bias due to the overcorrection of the systematic removal to be sub-dominant compared to the statistical uncertainty. We find fNL = −12 ± 21 (68 per cent confidence) for the main clustering sample including quasars with redshifts between 0.8 and 2.2, after applying redshift weighting techniques, designed for non-Gaussianity measurement from large scales structure, to optimize our analysis, which improve our results by 37 per cent.

79 ASTRONOMY AND ASTROPHYSICS↗

Trabecula: A Random Generator of Computational Phantoms for Bone Marrow Dosimetry

This study was motivated by the efforts on evaluation of radiation risk for leukemia incidence in the Techa River Cohort, where the main bone marrow dose contributors were 89,90Sr (bone-seeking beta emitters). Energy deposition in bone marrow targets was evaluated by simulating radiation particle transport using computational phantoms. The present paper describes the computer program “Trabecula” implementing an algorithm for parametric generation of computational phantoms, which serve as the basis for calculating bone marrow doses. “Trabecula” is a user-friendly tool that automatically converts analytical models into voxelized representations that are directly compatible as input to MCNP.

Shishkina, Elena A.↗

Preparing sparse solvers for exascale computing

Sparse solvers provide essential functionality for a wide variety of scientific applications. Highly parallel sparse solvers are essential for continuing advances in high-fidelity, multi-physics and multi-scale simulations, especially as we target exascale platforms. This paper describes the challenges, strategies and progress of the US Department of Energy Exascale Computing project towards providing sparse solvers for exascale computing platforms. We address the demands of systems with thousands of high-performance node devices where exposing concurrency, hiding latency and creating alternative algorithms become essential. The efforts described here are works in progress, highlighting current success and upcoming challenges.

97 MATHEMATICS AND COMPUTING↗

Population of low-seniority isomeric states of {sup 206}Hg by two-proton knockout reactions at relativistic energies

We consider calculations of direct two-proton removal reactions from a relativistic-energy {sup 208}Pb beam incident on a {sup 9}Be target, leading to the population of two-proton-hole isomeric configurations in {sup 206}Hg. The calculated 5{sup -} and 10{sup +} isomeric state population ratios of 18.8% and 4.7%, respectively, are in fair agreement with the values deduced experimentally (21.9{sub -2.9}{sup +1.2}% and 3.1{sub -1.2}{sup +1.0}%); however, the high density of final states in this case complicates the prediction of isomeric ratios for those states fed by unobserved prompt {gamma}-ray cascades. We also consider and quantify the effects of selection of events, according to the longitudinal momenta of the reaction residues, on the measured isomeric ratios for high-spin final states and, hence, of the potential to exploit such sensitivity to gain further insight into the reaction mechanism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decoupling behavior in {sup 132}La

Heavy-ion fusion reactions {sup 122}Sn({sup 14,15}N, xn){sup 132}La have been utilized for the lifetime measurements using the recoil distance method. The lifetimes of seven low-lying excited states were obtained. In addition, the lifetimes of two states belonging to a band, which was identified as a decoupled band, were obtained. The decoupling behavior in {sup 132}La has been theoretically investigated using the particle-rotor model in the model space of {pi}h{sub 11/2} and ({nu}s{sub 1/2}, {nu}d{sub 3/2}). The pseudospin coupling model was also utilized to understand the decoupling behavior in terms of the valence-particle configuration {pi}h{sub 11/2}({Omega}{sub {pi}}=(1/2)) x {nu}[411-tilde]({Omega}{sub {nu}}=(1/2),(3/2)), and a reasonable agreement with the experiment was obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission fragment angular distributions in the {sup 9}Be + {sup 232}Th reaction

Fission fragment angular distributions have been measured for a {sup 9}Be + {sup 232}Th system at four different beam energies around the Coulomb barrier. The experimental results on fission fragment anisotropies have been compared with predictions of the standard statistical saddle-point model (SSPM) and the preequilibrium fission (PEQ) model including projectile ground-state spin. It is observed that both SSPM and the PEQ model fail to reproduce the experimental results, indicating that projectile breakup may affect the fission fragment anisotropies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elemental characterization of LL-MA radioactive waste packages with the associated particle technique

The French Alternative Energies and Atomic Energy Commission (CEA) and National Radioactive Waste Management Agency (ANDRA) are conducting an R and D program to improve the characterization of long-lived and medium activity (LL-MA) radioactive waste packages with analytical methods and with non-destructive nuclear measurements. This paper concerns fast neutron interrogation with the associated particle technique (APT), which brings 3D information about the waste material composition. The characterization of volume elements filled with iron, water, aluminium, and PVC in bituminized and fibre concrete LL-MA waste packages has been investigated with MCNP [1] and MODAR data analysis software [2]. APT provides usable information about major elements presents in the volumes of interest. However, neutron scattering on hydrogen nuclei spreads the tagged neutron beam out of the targeted volume towards surrounding materials, reducing spatial selectivity. Simulation shows that small less than 1 L targets can be characterised up to the half-radius of a 225 L bituminized drum, the matrix of which is very rich in hydrogen. Deeper characterization in concrete is possible but limited by counting statistics due to photon attenuation in this dense matrix and, unless large inspection volumes are considered, by the lack of spatial selectivity of the tagged neutron beam due to neutron scattering. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of Shock Formation Parameters With Drive Conditions in Magnetically Accelerated Plasma Flows

We present experimental data regarding the formation of high-energy-density shocks in magnetically accelerated plasma flows using pulsed power drivers. We quantify the flow velocity and temperature of the ablated plasma using optical Thomson scattering and gated emission imaging across two different generators. We show that, regardless of the drive parameters, the plasma flows show continuous acceleration over centimeter spatial scales, in line with trends in published simulation work. When stationary targets are placed in these supersonic flows, bow-shock formation is observed at all drive parameters in a range of materials. In the higher density flow generated on the 1-MA COBRA generator at Cornell University, heating of the upstream flow ahead of the shock is observed and quantified, which is not observed at the lower density flow on the 0.2-MA Bertha driver at UC San Diego. Here, when combined with previous work on the XP generator at Cornell, we can show that these three experimental setups allow control of the effect of radiation loss and upstream absorption on the formation of the bow shock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array

Purpose: The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array, which generates all the projection images needed for tomosynthesis reconstruction by electronically activating individual x-ray sources without any mechanical motion. The stationary digital breast tomosynthesis (s-DBT) design aims to (i) increase the system spatial resolution by eliminating image blurring due to x-ray tube motion and (ii) reduce the scanning time. Low spatial resolution and long scanning time are the two main technical limitations of current DBT technology. Methods: A CNT x-ray source array was designed and evaluated against a set of targeted system performance parameters. Simulations were performed to determine the maximum anode heat load at the desired focal spot size and to design the electron focusing optics. Field emission current from CNT cathode was measured for an extended period of time to determine the stable life time of CNT cathode for an expected clinical operation scenario. The source array was manufactured, tested, and integrated with a Selenia scanner. An electronic control unit was developed to interface the source array with the detection system and to scan and regulate x-ray beams. The performance of the s-DBT system was evaluated using physical phantoms. Results: The spatially distributed CNT x-ray source array comprised 31 individually addressable x-ray sources covering a 30 angular span with 1 pitch and an isotropic focal spot size of 0.6 mm at full width at half-maximum. Stable operation at 28 kV(peak) anode voltage and 38 mA tube current was demonstrated with extended lifetime and good source-to-source consistency. For the standard imaging protocol of 15 views over 14, 100 mAs dose, and 2 x 2 detector binning, the projection resolution along the scanning direction increased from 4.0 cycles/mm [at 10% modulation-transfer-function (MTF)] in DBT to 5.1 cycles/mm in s-DBT at magnification factor of 1.08. The improvement is more pronounced for faster scanning speeds, wider angular coverage, and smaller detector pixel sizes. The scanning speed depends on the detector, the number of views, and the imaging dose. With 240 ms detector readout time, the s-DBT system scanning time is 6.3 s for a 15-view, 100 mAs scan regardless of the angular coverage. The scanning speed can be reduced to less than 4 s when detectors become faster. Initial phantom studies showed good quality reconstructed images. Conclusions: A prototype s-DBT scanner has been developed and evaluated by retrofitting the Selenia rotating gantry DBT scanner with a spatially distributed CNT x-ray source array. Preliminary results show that it improves system spatial resolution substantially by eliminating image blur due to x-ray focal spot motion. The scanner speed of s-DBT system is independent of angular coverage and can be increased with faster detector without image degration. The accelerated lifetime measurement demonstrated the long term stability of CNT x-ray source array with typical clinical operation lifetime over 3 years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗

Verification and compensation of respiratory motion using an ultrasound imaging system

Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm displacement resulted in compensation rates of 60%–84.4%. Conclusions: This study has shown that a respiratory compensating system combined with noninvasive ultrasound can provide real-time compensation of the respiratory motion of patients.

60 APPLIED LIFE SCIENCES↗

SU-F-T-671: Effects of Collimator Material On Proton Minibeams

Purpose: To investigate the dosimetric effects of collimator material on spatially modulated proton minibeams (pMBRT). Methods: pMBRT holds promise to exhibit shallow depth normal-tissue sparing effects similar to synchrotron based microbeams while also retaining potential for uniform dose distributions for tumor targets. TOPAS Monte Carlo simulations were performed for a 5cm thick multislit collimator with 0.3mm slits and 1mm center-to-center spacing for a 50.5MeV proton minibeam while varying collimator material between brass, tungsten, and iron. The collimator was placed both “flush” at the water phantom surface and at 5cm distance to investigate the effects on surface dose, peak-to-valley-dose-ratio (PVDR) and neutron contribution. Results: For flush placement, the neutron dose at the phantom surface for the tungsten collimator was approximately 20% higher than for brass and iron. This was not reflected in the overall surface dose, which was comparable for all materials due to the relatively low neutron contribution of <0.1%. When the collimator was retracted, the overall neutron contribution was essentially identical for all three collimators. Surface dose dropped by ∼40% for all collimator materials with air gap compared to being flush with the phantom surface. This surface dose reduction was at the cost of increase in valley dose for all collimator materials due to increased angular divergence of the mini-beams at the surface and their consequent geometric penumbra at depth. When the collimator was placed at distance from the phantom surface the PVDR decreased. The peak-to-entrance-dose ratio was highest for the iron collimator with 5cm air gap. Conclusion: The dosimetric difference between the collimator materials is minimal despite the relatively higher neutron contribution at the phantom surface for the tungsten collimator when placed flush. The air gap between the collimator and phantom surface strongly influences all dosimetry parameters due to the influence of scatter on the narrow spatial modulation.

60 APPLIED LIFE SCIENCES↗

Mathematical modeling of gas-dynamic and radiative processes in experiments with the use of laser and heavy-ion beams

Results are presented from theoretical and experimental studies of gas-dynamic and radiative processes in the plasma that is planned to be used in future experiments on the stopping of fast heavy-ion beams. These experiments are aimed at measuring the enhanced (as compared to cold substance) plasma stopping power. To reliably interpret the experimental results, it is necessary to create a hydrodynamically stable homogeneous plasma with a uniform temperature and a lifetime exceeding the transit time of the heavy-ion beam (3–5 ns). The method for calculating plasma gas-dynamic characteristics with allowance for radiative heat transfer is described. The specific features of the so-called ion model of plasma, which is used to calculate plasma radiative characteristics, are discussed. The emission spectrum formed as a result of conversion of laser radiation into X-rays and the subsequent passing through a triacetate cellulose (C{sub 12}H{sub 16}O{sub 8}) target is calculated. The simulated spectrum of transmitted radiation satisfactorily agrees with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

QCD For Intel(R) Xeon Phi(tm) and Xeon(tm) processors

This library provides a library containing highly optimized Wilson-Dslash, Wilson Clover operator and Krylov subspace solvers for Lattice QCD simulations. The library is targeted at Intel(R) Xeon Phi(tm), and Intel(R) Xeon(tm) processors.

Joo, Balint↗

Utah FORGE: Well 16A(78)-32 Planned Trajectory

This submission includes an Excel spreadsheet containing the Utah FORGE deep well 16A(78)-32 planned trajectory including UTM coordinates, elevations, and depths from the well head to the toe. This proposed new injection well is expected to descend vertically to a depth of approximately 1810 m and then extend laterally at an angle to a MD of approximately 3290 m and a maximum vertical depth of approximately 2584 m. There is approximately 1500 m of basin fill at the well head, and less than that above the simulation region with the targeted reservoir region fully enclosed in granitoid basement. The last 60 m of the well will be open hole. Drilling is planned for October 2020. Please direct questions to the Utah FORGE team: utahforge@utah.edu and check the Utah FORGE website: https://utahforge.com after October for more information.

15 GEOTHERMAL ENERGY↗

Patch-level CO2 and CH4 fluxes and porewater concentrations in experimental wetlands, 5 and 10 PPT saltwater intrusion simulations, Louisiana 2023-2024

This dataset containes carbon dioxide (CO2) and methane (CH4) flux measurements collected from wetland vegetation patches dominated by Typha domingensis and Panicum hemitomon to assess greenhouse gas flux responses to experimental saltwater intrusion (SWI) pulses. Measurements were conducted before, during, and after simulated SWI events at target salinities of approximately 5 parts per thousand (ppt) with durations of 6, 10, and 17 days and 10 ppt with a duration of 48 days, alongside a control wetland (with no salinity added, flood manipulation only). These data were generated to evaluate how the magnitude and duration of SWI alter wetland carbon exchange and related biogeochemical and plant responses. This data package includes flux measurements from the wetland surface (i.e, soil/water surface and enclosed vegetation) and from the soil/water surface only; porewater and surface water concentrations of CO2 and CH4; salinity, pH, electrical conductivity collected in porewater (at 5, 10, and 20 cm soil depths) and in surface water; soil redox potential; leaf spectral indices, leaf vapor pressure deficit, stomatal conductance; water level, salinity, and photosynthetically active radiation; and aboveground biomass.

EARTH SCIENCE > AGRICULTURE > SOILS > SOIL RESPIRA↗