Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Use of a multimission system for cost effective support of planetary science data processing

JPL's Multimission Operations Systems Office (MOSO) provides a multimission facility at JPL for processing science instrument data from NASA's planetary missions. This facility, the Multimission Image Processing System (MIPS), is developed and maintained by MOSO to meet requirements that span the NASA family of planetary missions. Although the word 'image' appears in the title, MIPS is used to process instrument data from a variety of science instruments. This paper describes the design of a new system architecture now being implemented within the MIPS to support future planetary mission activities at significantly reduced operations and maintenance cost.

Green, William B.↗

Low pressure electrospray ionization system and process for effective transmission of ions

A system and method are disclosed that provide up to complete transmission of ions between coupled stages with low effective ion losses. A novel "interfaceless" electrospray ionization system is further described that operates the electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer.

47 OTHER INSTRUMENTATION↗

Effect of reducing system on capacitive behavior of reduced graphene oxide film: Application for supercapacitor

To determine the best chemical reduction of graphene oxide film with hydriodic acid that gives maximum energy and power density, we studied the effect of two reducing systems, hydriodic acid/water and hydriodic acid/acetic acid, on the morphology and electrochemical features of reduced graphene oxide film. Using acetic acid as solvent results in high electrical conductivity (5195 S m{sup −1}), excellent specific capacitance (384 F g{sup −1}) and good cyclic stability (about 98% of its initial response after 4000 cycles). Using water as a solvent, results in an ideal capacitive behavior and excellent cyclic stability (about 6% increase of its initial response after 2100 cycles). - Graphical abstract: The choice of reducing system determines the morphology and structure of the chemically reduced graphene film and, as a result, affects largely the capacitive behavior. - Highlights: • The structure of the graphene film has a pronounced effect on capacitive behavior. • The use of water/HI as reducing system results in an ideal capacitive behavior. • The use of acetic acid/HI as reducing system results in a high specific capacitance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Report for contract DE-SC0010151, "A Cost-Effective Oxygen Separation System Based on Open Gradient Magnetic Field by Polymer Beads"

At present much of the oxygen enrichment market is based primarily on cryogenic systems, ion transport membranes made of ceramics, or polymer membranes technologies. All these methods have some positive and some negative attributes, but remain too expensive for the cost effective production of pure oxygen needed for clean renewable energy conversion projects. In a very successful Phase I period, the ITN-TAMU team accomplished the completion of most of the sub-tasks on oxygen separation based on our proposed magnetic field gradients. Theoretical and computer simulation data under different conditions of flow rates, magnetic flux, magnetic beads packing density, pressure and temperature have resulted very valuable observations. Chitosan based polymer magnetic beads showed the best results for uniformity and column packing. Due to limited magnetic force of 1 Tesla, we were restricted to use only single small column of magnetic beads and limited air pressure with controlled flow rate. We also fabricated smaller sized beads column with metal and clear plastic frames to be used for more concentrated packed capacity. Beads made with rare earth Neodymium were not uniform and were quite brittle. Different surfactants have minimized the effect of the de-aggregation of polymer magnetic beads. This Phase I development work also included overcoming key packaging hurdles such as high packing capacity of magnetic polymer beads and formation of consistent batch of magnetic beads. Market and commercialization studies were also initiated to show that there is a growing market for the proposed cost-effective oxygen separation system for energy conversion projects.

20 FOSSIL-FUELED POWER PLANTS↗

The Effective Fragment Molecular Orbital Method: Achieving High Scalability and Accuracy for Large Systems

The effective fragment molecular orbital (EFMO) method has been developed to predict the total energy of a very large molecular system accurately (with respect to the underlying quantum mechanical method) and efficiently by taking advantage of the locality of strong chemical interactions and employing a two-level hierarchical parallelism. The accuracy of the EFMO method is partly attributed to the accurate and robust intermolecular interaction prediction between distant fragments, in particular, the many-body polarization and dispersion effects, which require the generation of static and dynamic polarizability tensors by solving the coupled perturbed Hartree–Fock (CPHF) and time-dependent HF (TDHF) equations, respectively. Solving the CPHF and TDHF equations is the main EFMO computational bottleneck due to the inefficient (serial) and I/O-intensive implementation of the CPHF and TDHF solvers. In this work, the efficiency and scalability of the EFMO method are significantly improved with a new CPU memory-based implementation for solving the CPHF and TDHF equations that are parallelized by either message passing interface (MPI) or hybrid MPI/OpenMP. Here, the accuracy of the EFMO method is demonstrated for both covalently bonded systems and noncovalently bound molecular clusters by systematically examining the effects of basis sets and a key distance-related cutoff parameter, R cut . R cut determines whether a fragment pair (dimer) is treated by the chosen ab initio method or calculated using the effective fragment potential (EFP) method (separated dimers). Decreasing the value of Rcut increases the number of separated (EFP) dimers, thereby decreasing the computational effort. It is demonstrated that excellent accuracy (<1 kcal/mol error per fragment) can be achieved when using a sufficiently large basis set with diffuse functions coupled with a small R cut value. With the new parallel implementation, the total EFMO wall time is substantially reduced, especially with a high number of MPI ranks. Given a sufficient workload, nearly ideal strong scaling is achieved for the CPHF and TDHF parts of the calculation. For the first time, EFMO calculations with the inclusion of long-range polarization and dispersion interactions on a hydrated mesoporous silica nanoparticle with explicit water solvent molecules (more than 15k atoms) are achieved on a massively parallel supercomputer using nearly 1000 physical nodes. In addition, EFMO calculations on the carbinolamine formation step of an amine-catalyzed aldol reaction at the nanoscale with explicit solvent effects are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Propagation effects on satellite systems at frequencies below 10 GHz: A handbook for satellite systems design

Frequencies below 10 GHz continue to be used for a large portion of satellite service, and new applications, including mobile satellite service and the global positioning system, use frequencies below 10 GHz. As frequency decreases below 10 GHz, attenuation due to precipitation and gases decreases and ionospheric effects increase. Thus the ionosphere, which can be largely neglected above 10 GHz, receives major attention. Although attenuation and depolarization due to rain are less severe below 10 GHz than above, they are nevertheless still important and constitute another major topic. The handbook emphasizes the propagation effects on satellite communications but material that is pertinent to radio navigation and positioning systems and deep-space telecommunications is included as well. Chapter 1 through 7 describe the various propagation impairments, and Chapter 9 is devoted to the estimation or calculation of the magnitudes of these effects for use in system design. Chapter 10 covers link power budget equations and the role of propagation effects in these equations. Chapter 8 deals with the complex subject of interference between space and terrestrial systems.

Flock, Warren L.↗

Analysis of the effect of engine characteristics on the external aerodynamics of STOL wing propulsion systems

The effects of engine presssure ratio, engine size, and engine location on the pressure distribution, lift coefficient, and flow field of a STOL wing propulsion system are presented. The flow variables of the engines are included in the two-dimensional potential flow analysis by considering the effects of mass flow coefficient at the engine inlet and thrust coefficient at the engine exit. A functional relation between these coefficients and engine pressure ratio is given. The results of this study indicate that the effect of engine pressure ratio on the external aerodynamics is a function of engine location. For engines located on the bottom of the wing, the highest pressure ratio engine resulted in the highest lift coefficient. For engines located on the top of the wing, the lowest pressure ratio engine resulted in the highest lift coefficient.

Albers, J. A.↗

Continuous flow electrophoresis: The effect of sample concentration on throughput and resolution in an upward flowing system

The effect of sample concentration on throughput and resolution in a modified continuous particle electrophoresis (CPE) system with flow in an upward direction is investigated. Maximum resolution is achieved at concentrations ranging from 2 x 10 to the 8th power cells/ml to 8 x 10 to the 8th power cells/ml. The widest peak separation is at 2 x 10 to the 8th power cells/ml; however, the sharpest peaks and least overlap between cell populations is at 8 x 10 to the 8th power cells/ml. Apparently as a result of improved electrophoresis cell performance due to coasting the chamber with bovine serum albumin, changing the electrode membranes and rinse, and lowering buffer temperatures, sedimentation effects attending to higher concentrations are diminished. Throughput as measured by recovery of fixed cells is diminished at the concentrations judged most likely to yield satisfactory resolution. The tradeoff appears to be improved recovery/throughput at the expense of resolution.

Jandebeur, T. S.↗

Effects of water during cure on the properties of a carbon/phenolic system

The effects of prepreg water contamination on interlaminar shear strength, tranverse compressive strength, and longitudinal compressive strength were determined. Decreases in these properties due to water contamination were sugstantial: 28 percent for the interlaminar shear strength, 21 percent for the transverse compressive strength and 31 percent for the longitudinal compressive strength. Since voids were not detected by X-ray analysis, the most likely cause for these results is fiber-matrix debounding in the laminate.

Penn, B. G.↗

J-2X Turbopump Cavitation Diagnostics

The J-2X is the upper stage engine currently being designed by Pratt & Whitney Rocketdyne (PWR) for the Ares I Crew Launch Vehicle (CLV). Propellant supply requirements for the J-2X are defined by the Ares Upper Stage to J-2X Interface Control Document (ICD). Supply conditions outside ICD defined start or run boxes can induce turbopump cavitation leading to interruption of J-2X propellant flow during hot fire operation. In severe cases, cavitation can lead to uncontained engine failure with the potential to cause a vehicle catastrophic event. Turbopump and engine system performance models supported by system design information and test data are required to predict existence, severity, and consequences of a cavitation event. A cavitation model for each of the J-2X fuel and oxidizer turbopumps was developed using data from pump water flow test facilities at Pratt & Whitney Rocketdyne (PWR) and Marshall Space Flight Center (MSFC) together with data from Powerpack 1A testing at Stennis Space Center (SSC) and from heritage systems. These component models were implemented within the PWR J-2X Real Time Model (RTM) to provide a foundation for predicting system level effects following turbopump cavitation. The RTM serves as a general failure simulation platform supporting estimation of J-2X redline system effectiveness. A study to compare cavitation induced conditions with component level structural limit thresholds throughout the engine was performed using the RTM. Results provided insight into system level turbopump cavitation effects and redline system effectiveness in preventing structural limit violations. A need to better understand structural limits and redline system failure mitigation potential in the event of fuel side cavitation was indicated. This paper examines study results, efforts to mature J-2X turbopump cavitation models and structural limits, and issues with engine redline detection of cavitation and the use of vehicle-side abort triggers to augment the engine redline system.

Santi, I. Michael↗

Matrix-type effect on the magnetotransport properties of Ni–AlO and Ni–NbO composite systems

The effect of the insulating-matrix material on the electronic and magnetic properties of nanocomposites is investigated in the Ni{sub x}(Al{sub 2}O{sub 3}){sub 100–x} metal–insulator system and the Ni{sub x}(Nb{sub 2}O{sub 5}){sub 100–x} metal–semiconductor system. It is established that the characteristics of composites determined by electron transport through the matrix (the electrical resistivity, the position of the electrical percolation threshold, the magnetoresistance effect) depend on the material type. Replacement of the matrix from Al{sub 2}O{sub 3} to Nb{sub 2}O{sub 5} results in a decrease in the electrical resistivity by two–three orders of magnitude, a decrease in the magnetic resistivity by more than an order of magnitude, and in displacement of the percolation threshold from 40 to 30 at % of Ni. In this case, the magnetic properties of the composites are independent of the type of matrix: the concentration of the magnetic percolation threshold is identical in the two systems (~45 at % of Ni), and the coercive force of the samples occurring beyond the percolation threshold is close in magnitude (5–8 and 12–18 Oe) in the Ni{sub x}(Nb{sub 2}O{sub 5}){sub 100–x} and Ni{sub x}(Al{sub 2}O{sub 3}){sub 100–x} composites, respectively.

36 MATERIALS SCIENCE↗

Grading-System-Dependent Volume Effects for Late Radiation-Induced Rectal Toxicity After Curative Radiotherapy for Prostate Cancer

Purpose: To assess the association between the dose distributions in the rectum and late Radiation Therapy Oncology Group and the European Organisation for Research and Treatment of Cancer (RTOG/EORTC), Late Effects of Normal Tissue SOMA, and Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 graded rectal toxicity among patients with prostate cancer treated with RT. Methods and Materials: Included in the study were 124 patients who received three-dimensional conformal RT for prostate cancer to a total dose of 70 Gy in 2-Gy fractions. All patients completed questionnaires regarding rectum complaints before RT and during long-term follow-up. Late rectum Grade 2 or worse toxicity, according to RTOG/EORTC, LENT SOMA, and CTCAE v3.0 criteria, was analyzed in relation to rectal dose and volume parameters. Results: Dose-volume thresholds (V40 {>=}65%, V50 {>=}55%, V65 {>=}45%, V70 {>=}20%, and a rectum volume {<=}140 cm{sup 3}), significantly discriminated patients with late Grade 0-1 and Grade 2 or worse rectal toxicity, particularly using the LENT SOMA and CTCAE v3.0 systems. The rectum volume receiving {>=}70 Gy (V70) was most predictive for late Grade 2 or worse rectal toxicity with each of the grading systems. The associations were strongest, however, with use of the LENT SOMA system. Conclusions: Volume effects for late radiation-induced rectal toxicity are present, but their clinical significance depends on the grading system used. This should be taken into account in the interpretation of studies reporting on radiation-induced rectal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Cement Changes and Aggregate System on Mechanical Properties of Concrete

In this paper, mechanical properties of concrete mixtures containing different cementitious combinations and two aggregate systems were investigated under plastic and drying conditions. Emphasis was laid on durability and shrinkage of concrete. Life Cycle Analysis was also conducted by using Green Concrete LCA Webtool. Results indicated that the presence of larger aggregate sizes tend to enhance durability of concrete. The presence of nanosilica also imparted superior mechanical properties to concrete. A cementitious combination containing Portland Limestone Cement and fly ash with larger aggregate sizes emerged as a better performing mixture in terms of mechanical properties and with minimum environmental impact.

36 MATERIALS SCIENCE↗