Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Surgery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Management of Acute Aortic Syndrome and Chronic Aortic Dissection

Acute aortic syndrome (AAS) describes several life-threatening aortic pathologies. These include intramural hematoma, penetrating aortic ulcer, and acute aortic dissection (AAD). Advances in both imaging and endovascular treatment have led to an increase in diagnosis and improved management of these often catastrophic pathologies. Patients, who were previously consigned to medical management or high-risk open surgical repair, can now be offered minimally invasive solutions with reduced morbidity and mortality. Information from the International Registry of Acute Aortic Dissection (IRAD) database demonstrates how in selected patients with complicated AAD the 30-day mortality from open surgery is 17% and endovascular stenting is 6%. Despite these improvements in perioperative deaths, the risks of stroke and paraplegia remain with endovascular treatment (combined outcome risk 4%). The pathophysiology of each aspect of AAS is described. The best imaging techniques and the evolving role of endovascular techniques in the definitive management of AAS are discussed incorporating strategies to reduce perioperative morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Antibiotic Treatment of Severe Staphylococcal Infection of a Long Stent Graft in the Superficial Femoral Artery with Graft Preservation in the Long Term

Introduction: Bacterial infection of endovascular stent grafts is a serious condition, regularly leading to graft replacement by open bypass surgery.Case ReportWe describe the case of a staphylococcal infection of a 150-mm covered stent graft (Gore Viabahn), placed in the superficial femoral artery. Stent graft infection was successfully treated by oral administration of penicillinase-resistant flucloxacillin and the lipopeptide daptomycin with complete graft preservation, not requiring surgical treatment. During 1-year follow-up, the graft infection did not reappear. However, the patient developed restenosis at the proximal margin of the stent with recurrence of mild claudication, so far treated conservatively. Conclusion: With the increased use of covered stent grafts in the peripheral vasculature, the frequency of graft infection will increase. We demonstrate that with newly developed antibiotics, it is possible to treat this severe complication conservatively, with complete graft preservation and without the need for bypass surgery in selected cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lymphangiography in the Diagnosis and Localization of Various Chyle Leaks

Purpose: Chyle leaks are rare entities infrequently encountered by most physicians. However, large centers providing advanced surgical care are inevitably confronted with chyle leaks as a complication of surgery, an extension of disease, or as a primary disorder. Regardless of the etiology, proper diagnosis and localization are paramount in the management of any chyle leak. Materials and Methods: Here we present 16 patients with 17 chyle leaks (5 chyluria, 8 chylothorax, and 4 chylous ascites) who underwent bipedal lymphangiography (LAG) and postprocedure computed tomography (CT) imaging. Results: In each case, the source of the chyle leak was identified and properly localized to guide further treatment. Of the 16 patients who underwent LAG and postprocedure CT imaging, the initial LAG alone provided the diagnosis and localized the chyle leak in 4 patients (25%); the postprocedure CT imaging provided the diagnosis and localized the chyle leak in 6 patients (37.5%); and the two modalities were equal in the diagnosing and localizing the chyle leak in the remaining 6 patients (37.5%)ConclusionThese cases highlight the unparalleled abilities of LAG and the added benefit of post-LAG CT imaging in the diagnosis and fine anatomic localization of chyle leaks. In addition, these cases demonstrate the retained utility of LAG in these investigations despite the development of alternative tests involving CT, magnetic resonance imaging, and nuclear medicine imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Selective Embolectomy using a Fogarty Thru-Lumen Catheter for Pancreas Graft Thrombosis: A Case Report

A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas-kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor's portal vein was anastomosed to the recipient's inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our technique for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutaneous Bronchobiliary Fistula Treated with Tissucol Sealant

Bronchobiliary fistula is a rare and is an uncommon but severe complication of hydatid disease of the liver. Treatment has traditionally been surgical resection, but embolization and stent placement have been described. The invasive method seems to be a key component of patient treatment. We describe a case of a 58-year-old woman who, 25 years before, had undergone surgery for a hydatid cyst. A total cystectomy without previous puncture or parasite extraction was carried out. The lower aspect of the cyst was found to be completely perforated over the biliary duct. During the postoperative course, the patient had subphrenic right-sided pleural effusion and biliary fistula that subsided with medical treatment. Afterward, the patient came to the outpatient area of our hospital complaining of leakage of purulent exudate through the cutaneous opening, pain located on the right hypochondrium radiating to the right hemithorax, malaise, fever, chronic cough, and occasional vomiting of bile. Fistulography revealed an anfractuous cavity communicating with a residual cystic cavity on the right hepatic lobe. We observed communication with the intrahepatic canaliculi. Computed tomographic scan revealed a fistulous tract on the anterior liver border through the abdominal wall. There were no posttreatment complications. The patient is asymptomatic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Thrombin Injection to Control Rapid Expansion of Ascending Aortic False Aneurysm 15 Months After Bentall-Bono Operation

We report a case of 57-year-old man treated emergently with CT-guided local thrombin injection as the first, life-saving step for control rapid expansion of the aortic pseudoaneurysm. Fifteen months earlier, he was operated on for ascending aortic true aneurysm and coronary artery disease. Upon admission, he had an anterior thoracic wall pulsatile tumor. Due to critical status, definite surgery was postponed and thrombin was injected close to the origin of pseudoaneurysm. It controlled successfully, bleeding from the ascending aorta and enabled the patient to survive the acute phase.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of Acute Nonvariceal Upper Gastrointestinal Hemorrhage Resistant to Endoscopic Treatment: Results and Predictors of Recurrent Bleeding

Acute nonvariceal upper gastrointestinal (UGI) hemorrhage is a frequent complication associated with significant morbidity and mortality. The most common cause of UGI bleeding is peptic ulcer disease, but the differential diagnosis is diverse and includes tumors; ischemia; gastritis; arteriovenous malformations, such as Dieulafoy lesions; Mallory-Weiss tears; trauma; and iatrogenic causes. Aggressive treatment with early endoscopic hemostasis is essential for a favorable outcome. However, severe bleeding despite conservative medical treatment or endoscopic intervention occurs in 5-10% of patients, requiring surgery or transcatheter arterial embolization. Surgical intervention is usually an expeditious and gratifying endeavor, but it can be associated with high operative mortality rates. Endovascular management using superselective catheterization of the culprit vessel, < sandwich> occlusion, or blind embolization has emerged as an alternative to emergent operative intervention for high-risk patients and is now considered the first-line therapy for massive UGI bleeding refractory to endoscopic treatment. Indeed, many published studies have confirmed the feasibility of this approach and its high technical and clinical success rates, which range from 69 to 100% and from 63 to 97%, respectively, even if the choice of the best embolic agent among coils, cyanaocrylate glue, gelatin sponge, or calibrated particles remains a matter of debate. However, factors influencing clinical outcome, especially predictors of early rebleeding, are poorly understood, and few studies have addressed this issue. This review of the literature will attempt to define the role of embolotherapy for acute nonvariceal UGI hemorrhage that fails to respond to endoscopic hemostasis and to summarize data on factors predicting angiographic and embolization failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Arterial Embolisation in a Trauma Patient with a Pre-Existing Aortobifemoral Graft

Pelvic fractures secondary to blunt trauma are associated with a significant mortality rate due to uncontrolled bleeding. Interventional radiology (IR) can play an important and central role in the management of such patients, offering definitive minimally invasive therapy and avoiding the need for high-risk surgery. Rapid access to whole-body computed tomography has been shown to improve survival in polytrauma patients and allows rapid diagnosis of vascular injury and assessment of suitability for endovascular therapy. IR can then target and treat the specific area of bleeding. Embolisation of bleeding pelvic arteries has been shown to be highly effective and should be the treatment of choice in this situation. The branches of the internal iliac artery (IIA) are usually involved, and these arteries are accessed by way of IIA catheterisation after abdominal aortography. Occasionally these arteries cannot be accessed by way of this conventional route because of recent IIA ligation carried out surgically in an attempt to stop the bleeding or because (in the rare situation we describe here) these vessels are excluded secondary to previous aortoiliac repair. In this situation, knowledge of pelvic arterial collateral artery pathways is important because these will continue to supply pelvic structures whilst making access to deep pelvic branches challenging. We describe a rare case, which has not been previously reported in the literature, in which successful embolisation of a bleeding pelvic artery was carried out by way of the collateral artery pathways.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Budd-Chiari Syndrome Complicating Hydatid Cyst of the Liver Managed by Venoplasty and Stenting

Budd-Chiari syndrome (BCS) and portal hypertension is an uncommon complication of hydatid cyst of the liver. Previous reports describe cyst excision or portosystemic shunt surgery for such patients. Here we present a case of hydatid cyst of the liver with BCS that was treated successfully with hepatic venoplasty and transjugular stent placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of Lung Tumours with the Patient Under Thoracic Epidural Anaesthesia

Radiofrequency ablation of lung tumours is a curative technique that is newly considered being offered to nonsurgical patients. It is of major interest because it enables local destruction of the tumour without surgery and spares healthy parenchyma. However, some patients have previous serious respiratory failure, thus ruling out mechanical ventilation. To operate with the patient under thoracic epidural is an answer to this problem. Our experience shows that the procedure is able to be performed completely without converting to general anaesthesia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relay NBS Graft with the Plus Delivery System to Improve Deployment in Aortic Arch with Small Radius Curve

The purpose of this report is to describe deployment of the Relay NBS Thoracic Stent Graft with the Plus Delivery System (Bolton Medical, Sunrise, FL) in a flexible resin arch model with a 15-mm radius curve as well as our preliminary clinical results. The Relay NBS graft with the Plus Delivery System was evaluated by way of bench testing, which was performed with stent grafts with diameters ranging from 24 to 46 mm and lengths ranging from 100 to 250 mm in flexible resin arch models with a 15-mm arch radius of curvature. The deployment sequence was analyzed. The Relay NBS graft with the Plus Delivery System was deployed in two patients, respectively, having a 6.5-cm penetrating aortic ulcer of the proximal third of the descending thoracic aorta and a DeBakey type-I aortic dissection with chronic false lumen dilatation after surgery due to an entry site at the distal thoracic aorta. Bench tests showed proper conformation and apposition of the Relay NBS graft with the Plus Delivery System in the flexible resin model. This stent graft was deployed successfully into the two patients with a correct orientation of the first stent and without early or late complications. The Relay NBS graft with the Plus Delivery System ensures an optimal conformation and apposition of the first stent in the aortic arch with a small radius of curvature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Device for True Lumen Re-Entry After Subintimal Recanalization of Superficial Femoral Arteries: First-in-Man Experience and Technical Description

Subintimal angioplasty (SAP) is frequently performed for the treatment of critical limb ischemia (CLI) and has been recognized as an effective technique for these patients. Nevertheless, this approach is limited by the lack of controlled re-entry into the true lumen of the target vessel. We describe a novel device for true lumen re-entry after subintimal recanalization of superficial femoral arteries (SFA). We report our experience with six patients treated between April 2009 and January 2010 with a novel system designed to facilitate true lumen re-entry. The device was advanced by ipsilateral antegrade approach through a 6-French sheath. Successful reaccess into the true lumen was obtained in five of six patients without complications. The patient in whom the reaccess to the true lumen was not possible underwent successful bypass surgery. At 30 days follow-up, the SFA was patent in all patients according to echo-Doppler examination. Our preliminary experience indicates that this novel re-entry device increases the success rate of percutaneous revascularization of chronically occluded SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Occlusion of Arteriovenous Fistulas of In-Situ Saphenous Vein Bypass Grafts Using the Amplatzer Vascular Plug 4: Initial Experience

We examined the safety and efficacy of vessel occlusion of the Amplatzer Vascular Plug 4 (AVP-4) in patients with arteriovenous fistulas after in-situ saphenous vein bypass grafts. We treated 18 fistulas of seven patients (four women, mean {+-} standard deviation age 76 {+-} 7 years, range 63-88 years). All fistulas were detected within 14 days after surgery. Initial diagnosis and follow-up was established by sonography. We measured the diameter of the feeding vessel and the time of vessel occlusion after plug deployment. Additionally, we recorded procedure time and the dose area product. Additional interventional procedures were necessary in three patients. We successfully used 19 AVP-4 for occlusion of all fistulas without thromboembolic complications. There was no need for recapturing the device, and we did not observe dislocation. Mean occlusion time was 9.6 min (range 5-22 min). Mean diameter of the feeding vessels was 3.5 mm (range 2.6-5.1 mm). Plug sizes ranged from 4-8 mm (mean 5.5 mm) resulting in an oversizing of 33-88%. Mean procedure time for patients with and without additional intervention was 91 {+-} 38 min and 35 {+-} 18 min, respectively. Mean dose area product was 11,790 cGy/cm{sup 2} (range 1,850-23,500 cGy/cm{sup 2}). Permanent occlusion of the fistulas was confirmed by ultrasound after a mean follow-up of 4 months (1-6 months). Occlusion of arteriovenous fistulas with an AVP-4 seems to be effective and safe in patients with in-situ saphenous vein bypass grafts. The AVP-4 is well suited for this purpose because of the appropriate diameter of the feeding vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advancements in Orthopedic Intervention: Retrograde Drilling and Bone Grafting of Osteochondral Lesions of the Knee Using Magnetic Resonance Imaging Guidance

Computer-assisted surgery is currently a novel challenge for surgeons and interventional radiologists. Magnetic resonance imaging (MRI)-guided procedures are still evolving. In this experimental study, we describe and assess an innovative passive-navigation method for MRI-guided treatment of osteochondritis dissecans of the knee. A navigation principle using a passive-navigation device was evaluated in six cadaveric knee joint specimens for potential applicability in retrograde drilling and bone grafting of osteochondral lesions using MRI guidance. Feasibility and accuracy were evaluated in an open MRI scanner (1.0 T Philips Panorama HFO MRI System). Interactive MRI navigation allowed precise drilling and bone grafting of osteochondral lesions of the knee. All lesions were hit with an accuracy of 1.86 mm in the coronal plane and 1.4 mm the sagittal plane. Targeting of all lesions was possible with a single drilling. MRI allowed excellent assessment of correct positioning of the cancellous bone cylinder during bone grafting. The navigation device and anatomic structures could be clearly identified and distinguished throughout the entire drilling procedure. MRI-assisted navigation method using a passive navigation device is feasible for the treatment of osteochondral lesions of the knee under MRI guidance and allows precise and safe drilling without exposure to ionizing radiation. This method may be a viable alternative to other navigation principles, especially for pediatric and adolescent patients. This MRI-navigated method is also potentially applicable in many other MRI-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Treatment of Small Renal Tumors: Trends in Renal Cancer Diagnosis and Management

Renal cell carcinoma is a common malignancy causing significant mortality. In recent years abdominal imaging, often for alternate symptomatology, has led the trend toward the detection and confirmation of smaller renal tumors. This has permitted the greater use of localized and nephron-sparing techniques including partial nephrectomy and image-guided ablation. This article aims to review the current role of image-guided biopsy and ablation in the management of small renal tumors. The natural history of renal cell carcinoma, the role of renal biopsy, the principles and procedural considerations of thermal energy ablation, and the oncological outcomes of these minimally invasive treatments are discussed and illustrated with cases from the authors' institution. Image-guided ablation, in particular, has changed the treatment paradigm and, by virtue of its increasingly evident efficacy and low morbidity, now favors the treatment of smaller tumors in patients previously unfit for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Carotid-Internal Jugular Fistula as a Late Complication After Carotid Endarterectomy: A Rare Case

A 66-year-old man presented with mild amnesia, progressive fatigue, ataxia, visual hallucinations, and debility. His past medical history included right-sided carotid endarterectomy performed elsewhere 6 years previously. Cranial magnetic resonance imaging showed left parieto-occipital arteriovenous malformation-like tortous vessels, venous congestion, and ischemic areas. Cerebral angiography showed right-sided compound external carotid artery-internal jugular vein (IJV) fistula, and distal occlusion of the right IJV. Transvenous embolization via contralateral IJV was performed, and the fistula, together with fistulous portion of the distal IJV, was sealed using coils. Two years later, patient is well with normal neurologic examination findings. The presence of an arteriovenous communication after vascular surgery is a serious complication with potential long-term effects and therefore should be diagnosed and treated as promptly as possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measured 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intra-Arterial Hepatic Chemotherapy: A Comparison of Percutaneous Versus Surgical Implantation of Port-Catheters

Purpose: To compare retrospectively the safety and efficacy of percutaneous and surgical implantations of port-catheters for intra-arterial hepatic chemotherapy (IAHC). Materials and Methods: Between January 2004 and December 2008, 126 consecutive patients (mean age 58 years) suffering from liver colorectal metastases were referred for intra-arterial hepatic chemotherapy (IAHC). Port-catheters were percutaneously implanted (P) through femoral access with the patient under conscious sedation when no other surgery was planned or were surgically implanted (S) when laparotomy was performed for another purpose. We report the implantation success rate, primary functionality, functionality after revision, and complications of IAHC. Results: The success rates of implantation were 97% (n = 65 of 67) for P and 98% (n = 58 of 59) for S. One hundred eleven patients received IAHC in our institution (n = 56P and n = 55S). Primary functionality was the same for P and S (4.80 vs. 4.82 courses), but functionality after revision was significantly higher for P (9.18 vs. 5.95 courses, p = 0.004) than for S. Forty-five complications occurred during 516 courses for P and 28 complications occurred during 331 courses for S. The rates of discontinuation of IAHC linked to complications of the port-catheters were 21% (n = 12 of 56) for P and 34% (n = 19 of 55) for S. Conclusion: Overall, significantly better functionality and similar complication rates occurred after P versus S port-catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗