Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Protonic Ceramics for Energy Storage & Electricity Generation with Ammonia (Final Report)

The commercial product resulting from this R&D project will enable cost-effective synthesis of the Carbon Neutral Liquid Fuel (CNLF) ammonia, a common chemical, at a small scale for energy and industrial applications using only intermittent renewable energy, water, and air as feedstocks. These products are also capable of producing electrical energy from the CNLF in a fuel cell mode of operation. Thus, the eventual commercial product enables both single direction production of either CLNF or electricity, or alternatively functions as a fully reversible, self-contained energy storage device. The renewed interest in developing electrolysis systems is driven, in part, by the burgeoning renewable, solar, and wind industries and the need for an energy conversion and storage technology that can convert intermittent solar and wind energy into the production of hydrogen. Electrolysis systems integrated into both distributed and central renewable power plants would utilize solar and wind energy as their primary power source to produce renewably generated hydrogen for local energy storage or chemical feedstock purposes. Ammonia is an excellent surrogate for hydrogen transportation. NH3 presents an attractive alternative to hydrogen as a working fluid in reversible devices towards a sustainable green energy-oriented future. Ammonia can be easily liquefied at room temperature at about 8 bar or at -33°C at ambient pressure. In contrast, the liquefaction temperature of hydrogen is -253°C at ambient pressure. NH3 has a significantly higher volumetric energy density (12.7 MJ/L) than compressed hydrogen (4.5 MJ/L at ~70 MPa) or liquefied hydrogen (8.5 MJ/L). Additionally, ammonia is a widely used raw material for agriculture fertilizer and thus has well-established storage, transport, and handling processes (about 180 million tons of ammonia are produced annually). Techno-economic analysis suggests ammonia is the least expensive fuel among hydrogen, gasoline, natural gas, liquefied petroleum gas, and methanol.

08 HYDROGEN↗

Revenue Analysis for Energy Storage Systems in the United States

In this work we evaluate the potential revenue from energy storage using historical electricity prices, forward-looking projections of hourly electricity prices, and actual reported revenue. This analysis examines the impact of storage characteristics, specifically duration and round-trip efficiency, as well as locational elements of storage revenue within the current and projected U.S. power system. Figure ES-1 illustrates the revenue for a 1 MW storage system in seven market regions with durations range from 1 hour to 12 hours using both historical and forward-looking price data. The historical analysis covers more than 500 price nodes for each market region, while the forward-looking analysis includes balancing areas under different 10 scenarios of the electricity generation mix. The results indicate that the revenues consistently increase with duration, though the marginal value declines as duration grows. Moreover, the range of revenue depends on the system's operational location, and the electricity generation mix changes for future years. This range also widens with increased durations. In addition, the sensitivity analysis of round-trip efficiency reveals that as efficiency improves, system revenue increases, though the value of better round-trip efficiency declines as at higher efficiency levels.

25 ENERGY STORAGE↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Numerical Modeling & Size Optimization of Thermal Energy Storage for Iron & Steel Production

Iron and steel production are responsible for 90 million MtCO2 per year in the United States. Hydrogen direct reduction of iron (H2DRI) is a promising pathway for a more sustainable iron production than commercially deployed technologies which rely on natural gas. The H2DRI process requires hydrogen at a temperature of up to 950 degrees C fed into a reduction furnace to produce pellets or briquettes that are used in the downstream iron and steelmaking process. In this work, we propose to use an electrical thermal energy storage (ETES) system, that can use renewable electricity to store high-temperature heat and dispatch it upon demand. Such a system can buffer the H2DRI plant from the variability of electricity prices by charging during curtailment and running the plant from storage during times of peak electricity price. We have developed heat transfer models for two different ETES systems that can be used to heat up hydrogen to the required temperatures: a particle-based ETES and a firebrick ETES. These models are used to evaluate the performance of such a system and support the sizing and preliminary cost estimation. The preliminary results using both models show that designing ETES systems for an industrial-scale H2DRI furnace is feasible. The firebrick ETES system has limited operational duration, which might limit the price buffering effect unless significantly oversized. The particle ETES system heat exchanger has industry-feasible dimensions, but its storage capacity would be decided upon the number of particle storage silos.

25 ENERGY STORAGE↗

Long Duration Energy Storage Viability Survey

Energy storage technologies that can economically store and provide electricity over multi-day and seasonal timescales are likely to be a critical component of a sustainable and resilient energy system. This analysis performs a broad survey of energy storage technologies to find storage media that are promising for these long-duration energy storage applications.

levelized cost of storage↗

Energy Storage Improves Power Plant Flexibility and Economic Performance

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenue, as well as to operate air pollution control devices at design conditions. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant operating or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation, such as wind and solar, is shifting the traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and a lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. Recent studies have shown that the flexibility of a coal-fired power plant can be improved by energy storage. The objective of this work was to analyze a set of energy storage options and determine their impact on the flexibility and economics of a representative coal-fired power plant. The effect of three energy storage systems integrated with a coal power plant on plant flexibility and economics was investigated. The results obtained in this project show that energy storage systems integrated with a thermal power plant improve plant flexibility and participation in the energy and ancillary services markets, which improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Li-Ion Battery Degradation and Performance [Slides]

This presentation is intended for power system engineers, operators, and planners who work on isolated power systems that have (or may soon have) high levels of power generation coming from wind turbines, solar farms, and battery energy storage, which are collectively referred to as inverter-based resources. It describes the basics of lithium-ion battery energy storage systems and lithium-ion battery degradation. Battery degradation at the cell-level is explained, and then the structure and degradation of battery energy storage systems is also explained. This is intended to help power system engineers, operators, and planners to understand and effectively utilize battery energy storage systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life Cycle Assessment for Closed-Loop Pumped Hydropower Energy Storage in the United States

The federal government has initiated an aggressive set of policies to achieve a net-zero carbon emission goal for the electricity sector by 2050. As a result, rapid growth in deployment of renewable energy technologies is expected. Most commercially mature technologies are temporally variable and do not provide grid inertia, while renewable technologies with high projected deployment have intermittent generation methods. Energy storage technologies are needed to both dispatch power on-demand and help provide the needed grid inertia. Pumped storage hydro (PSH) is a well-established technology that has gained renewed interest in recent years offering energy-balancing, grid stability, control of electrical network frequency, and large-scale storage capacity. For widespread adoption of PSH, more information is needed regarding its current life cycle environmental impacts. The objective of this study is to perform a full life cycle assessment (LCA) of new closed-loop PSH in the U.S. The functional unit for this study is 1 kWh of electrical power delivered to the grid and the base case project lifetime is 80 years. The life cycle inventory for this project accounts for all material and energy flows associated with the green-field construction, operation, maintenance, and decommissioning of a closed-loop PSH plant in the U.S. Collected data represents a range of potential PSH specifications and geographic locations coming from all prospective closed-loop PSH installations in the U.S. with data available. In addition, existing PSH installations are used to provide assumptions for inventory inputs. Results presented will include the global warming potential (GWP IPCC 100a) and Energy Return on Investment (EROI) from our base case (average PSH installation) as well as from scenario analyses and model sensitivity. These results will be compared to the impacts from existing PSH sites and alternate storage technologies. Methods align with the assumptions and guidelines put in place by previous PSH LCAs to ensure an accurate comparison with the results from this report.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Numerical Evaluation of Effective Thermal Conductivity of PCM with Metal Foam Incorporating Buoyancy Effects for Thermal Energy Storage

The thermal energy storage (TES) system has the capability to efficiently preserve thermal energy directly derived from the energy source, minimizing any conversion losses. Especially latent heat storage offers distinct advantages, including a substantial increase in energy storage density and minimization of temperature fluctuations within the plants. However, the phase change material (PCM) employed in latent heat storage has low thermal conductivity. Consequently, various studies are being conducted to enhance heat transfer. One approach to enhance heat transfer involves utilizing metal foam to maximize the heat transfer area. However, modeling metal foam with its intricate structure is a challenging task in numerical analysis. For this reason, ongoing research focuses on simplifying the modeling of metal foam. Nevertheless, fully encompassing all the characteristics of actual metal foam proves to be a challenging task for the simplified analytical model. The objective of this paper is to interpret the simple lattice metal foam analysis model from the perspective of behavior induced by buoyancy. When comparing the analysis results of solid PCM and liquid PCM with the same thermal conductivity under changes in porosity and gravity direction, we conducted an analysis to discern the trends in effective thermal conductivity that are overestimated due to convection. In the analysis, a constant heat flux of 10 kW and a constant surface boundary condition of 350 K were applied, and a sensitivity study regarding the mesh was conducted. The results indicate that, from the perspective of gravity in the simple lattice model, the solid analysis yields an effective thermal conductivity 29-47% higher compared to the liquid analysis. Additionally, as porosity increases, there is an observed increase of 24-33% in effective thermal conductivity.

25 ENERGY STORAGE↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

Impact Analysis of Utility-Scale Energy Storage on the ERCOT Grid in Reducing Renewable Generation Curtailments and Emissions

This paper explores the solutions for minimizing renewable energy (RE) curtailment in the Texas Electric Reliability Council of Texas (ERCOT) grid. By utilizing current and future planning data from ERCOT and the System Advisor Model from the National Renewable Energy Laboratory, we examine how future renewable energy (RE) initiatives, combined with utility-scale energy storage, can reduce CO2 emissions while reshaping Texas’s energy mix. The study projects the energy landscape from 2023 to 2033, considering the planned phase-out of fossil fuel plants and the integration of new wind/solar projects. By comparing emissions under different load scenarios, with and without storage, we demonstrate storage’s role in optimizing RE utilization. The findings of this paper provide actionable guidance for energy stakeholders, underscoring the need to expand wind and solar projects with strategic storage solutions to maximize Texas's RE capacity and substantially reduce CO2 emissions.

14 SOLAR ENERGY↗

Behind-the-Meter Battery Storage: Frequently Asked Questions

This quick read provides concise answers to frequently asked questions about behind-the-meter (BTM) storage systems. It includes a basic introduction to BTM energy storage and the services it can provide and helps dispel some common misconceptions. It touches on the building blocks that support BTM storage deployment and its safe incorporation into power system operations. Examples and best practices from advanced jurisdictions that can be applied elsewhere are also included.

25 ENERGY STORAGE↗

A Bulk versus Nanoscale Hydrogen Storage Paradox Revealed by Material-System Co-Design

Metal hydrides are serious contenders for materials-based hydrogen storage to overcome constraints associated with compressed or liquefied H 2 . Their ultimate performance is usually evaluated using intrinsic material properties without considering a systems design perspective. An illustrative case with startling implications is (LiNH 2 +2LiH). Using models that simulate the storage system and associated fuel cell of a light-duty vehicle (LDV), the performance of the bulk hydrides is compared with a nanoscaled version in porous carbon (PC), (LiNH 2 +2LiH)@(6-nm PC). Using experimental material properties, the simulations show that (LiNH 2 +2LiH)@(6-nm PC) counterintuitively has higher usable gravimetric and volumetric capacities than the bulk counterpart on a system basis despite having lower capacities on a materials-only basis. Nanoscaling increases the thermal conductivity and lowers the desorption enthalpy, which consequently increases heat management efficiency. In a simulated drive cycle for fuel cell-powered LDV, the fuel cell is inoperable using bulk (LiNH 2 +2LiH) as the storage material but completes the drive cycle using the nanoscale material. Further, these results challenge the notion that nanoscaling incurs mass and volume penalties. Instead, the synergistic nanoporous host-hydride interaction can favorably modulate chemical and heat transfer properties. Moreover, a co-design approach considering application-specific tradeoffs is essential to accurately assess a material's potential for real-world hydrogen storage.

08 HYDROGEN↗

Technoeconomic Insights into Metal Hydrides for Stationary Hydrogen Storage

Abstract Metal hydrides (MHs) are promising candidates for storing hydrogen at ambient conditions at high volumetric energy densities. Recent developments suggest hydride‐based systems can cycle and operate at favorable pressures and temperatures that work well with fuel cells used in stationary power applications. In this study, we present a comprehensive design and cost analysis of MH‐based long duration hydrogen storage facilities for a variety of power end users (0 to 20 megawatts (MW) supplied over 0 to 100 hours), to offer insights on technical targets for material development and operation strategies. Our findings indicate that hydride‐based storage systems hold significant size advantage in physical footprint, requiring up to 65% less land than 170‐bar compressed gas storage. Metal hydride systems can be cost competitive with 350‐bar compressed gas systems, with TiFe 0.85 Mn 0.05 achieving $0.45/kWh and complex MH Mg(NH 2 ) 2 ‐2.1LiH‐0.1KH achieving $0.38/kWh. Extending charging times and increasing operating cycles significantly reduce levelized cost of storage, especially for complex MHs. Key strategies to further enhance the competitiveness of MHs include leveraging waste heat from fuel cells, reducing use of critical minerals, and achieving MH production costs of US$10/kg.

08 HYDROGEN↗

Molecular Understanding of Charge Storage in MoS 2 Supercapacitors with Ionic Liquids

Owing to high electrical conductivity and ability to reversibly host a variety of inserted ions, 2D metallic molybdenum disulfide (1T-MoS 2 ) has demonstrated promising energy storage performance when used as a supercapacitor electrode. However, its charge storage mechanism is still not fully understood, in particular, how the interlayer spacing of 1T-MoS 2 would affect its capacitive performance. In this work, molecular dynamics simulations of 1T-MoS 2 with interlayer spacing ranging from 0.615 to 1.615 nm have been performed to investigate the resulting charge storage capacity in ionic liquids. Simulations reveal a camel-like capacitance-potential relation, and MoS 2 with an interlayer spacing of 1.115 nm has the highest volumetric and gravimetric capacitance of 118 F cm –3 and 42 F g –1 , respectively. Although ions in MoS 2 with an interlayer spacing of 1.115 nm diffuse much faster than with interlayer spacings of 1.365 and 1.615 nm, the MoS 2 with larger interlayer spacing has a much faster-charging process. Our analyses reveal that the ion number density and its charging speed, as well as ion motion paths, have significant impacts on the charging response. Here, this work helps to understand how the interlayer spacing affects the interlayer ion structures and the capacitive performance of MoS 2 , which is important for revealing the charge storage mechanism and designing MoS 2 supercapacitor.

25 ENERGY STORAGE↗

Conservative solute transport processes and associated transient storage mechanisms: Comparing streams with contrasting channel morphologies, land use and land cover

Abstract Land use within a watershed impacts stream channel morphology and hydrology and, therefore, in‐stream solute transport processes and associated transient storage mechanisms. This study evaluated transport processes in two contrasting stream sites where channel morphology was influenced by the surrounding land use, land cover, climate and geologic controls: Como Creek, CO, a relatively undisturbed, high gradient, forested stream with a gravel bed and complex channel morphology, and Clear Creek, IA, an incised, low‐gradient stream with low‐permeability substrate draining an agricultural landscape. We performed conservative stream tracer injections at these sites to address the following questions: (1) How does solute transport vary between streams with differing morphologies? and (2) How does solute transport at each stream site change as a function of discharge? We analysed in‐stream tracer time series data and compared results quantifying solute attenuation in surface and subsurface transient storage zones. Significant trends were observed in these metrics with varying discharge conditions at the forested site but not at the agricultural site. There was a broad range of transport mechanisms and evidence of substantial exchange with both surface and hyporheic transient storage in the relatively undisturbed, forested stream. Changing discharge conditions activated or deactivated different solute transport mechanisms in the forested site and greatly impacted advective travel time. Conversely in the simplified agricultural stream, there was a narrow range of solute transport behaviour across flows and predominantly surface transient storage at all measured discharge conditions. These results demonstrate how channel simplification inhibits available solute transport mechanisms across varying discharge conditions.

54 ENVIRONMENTAL SCIENCES↗

Optimal Sizing and Dispatch of Solar Power with Storage

Designers of utility-scale solar plants with storage, seeking to maximize some aspect of plant performance, face multiple challenges. In many geographic locations, there is significant penetration of photovoltaic generation, which depresses energy prices during the hours of solar availability. An energy storage system affords the opportunity to dispatch during higher-priced time periods, but complicates plant design and dispatch decisions. Solar resource variability compounds these challenges, because determining optimal system sizes requires simultaneously considering how the plant will be operated under the imposed market and weather conditions. We develop an approach to analyze the economic performance of hybrid and single-technology solar power plants, which incorporates optimal dispatch, and considers the expected electricity market and weather conditions. We utilize the System Advisor Model software package to simulate the operation of multiple renewable generation and energy storage technologies, in conjunction with hourly-fidelity generation decisions determined by a revenue-maximizing, mixed-integer linear program. We show that, under our assumed market and weather conditions, the lifetime benefit-to-cost ratio can be improved by 6 to 19 percent, relative to a baseline design without optimizing, and that a concentrating solar power with thermal energy storage design produces significantly more energy per year, but is less profitable under our cost assumptions.

black-box optimization↗

dCache: The Storage System of Choice for Data-Intensive Applications

The ever-increasing volumes of data produced by modern scientific facilities like EuXFEL and LHC put significant stress on data management infrastructure operated by laboratories and research centers. The challenges to be addressed span the entire data life cycle, from ingest and efficient data analysis to long-term preservation, typically involving large tape libraries. dCache, a storage system developed in collaboration between the Deutsches Elektronen-Synchrotron (DESY), Fermi National Accelerator Laboratory, and Nordic e-Infrastructure Collaboration (NeIC), is designed to manage a large number of disk servers and to facilitate transparent data migration to and from archival storage. Its multifaceted approach offers a unified method to support a variety of scientific use cases with the same storage infrastructure, including high-throughput data ingest, data sharing over wide area networks, efficient access from HPC clusters, and long-term data preservation on tertiary storage. Initially developed for high energy physics (HEP) experiments, dCache is now used by various scientific communities, including astrophysics, biomedical research, and life sciences, each having specific requirements. This paper presents architecture, deployment strategies, performance and scalability enhancements, and recent advancements in dCache addressing the needs of scientific communities. Finally, we touch on the development and release process, ensuring the software’s high quality.

DCache↗