Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sealing pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

Lueders, Kathy↗

MIS Shelf-Life Final Report for Plutonium Oxide Item CAN92 (SSR147) from Rocky Flats Analytical Laboratory Operations

A plutonium/uranium oxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample CAN92 represents plutonium/uranium oxides stored in 3013 containers. The material originated in the analytical laboratory at Rocky Flats. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/400th of the volume of a 3013 container. Gas compositions had been measured periodically over 5 ½ years. The maximum observed gas pressure from gas generation was 117 kPa. The increase over the initial pressure of 77.5 kPa was largely due to the generation of nitrogen and carbon dioxide with minor amounts of hydrogen and nitrous oxide. The internal components of SSR147 were inspected 6.5 years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 1,937 days had an etched appearance and general corrosion. No pitting was observed on the inner bucket that held the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High pressure pulsed capillary viscometry

An analytical and test program was conducted in order to establish the feasibility of a multichamber pulsed-capillary viscometer. The initial design incorporated a piston, ram, and seals which produced measured pulses up to 30,000 psi in the closed chamber system. Pressure pulses from one to ten milliseconds were investigated in a system volume of 1 cuin. Four test fluids: a MIL-L-7808, a 5P4E polyphenyl ether, a MIL-L-23699A, and a synthetic hydrocarbon were examined in the test pressure assembly. The pressure-viscosity coefficient and viscosity delay time were determined for the MIL-L-7808 lubricant tested.

Smith, R. L.↗

Lightweight door seals cryogenic container against diaphragm type loading

Lightweight, removable, sealed joint access door for a spherical or semispherical pressure vessel containing cryogenic materials uses a joint overlock design to take the shear and moment loads. Oversize bolt holes are used so that the attaching bolts are in tension only.

Englehart, R. C., Jr.↗

Cryostat modified to aid rotating beam fatigue test

Modified stainless steel Dewar aids rotating beam fatigue test in a cryogenic environment. The Dewar is modified to receive extended specimen supporting members through specially designed rotary seals. The test set can be fully enclosed and pressurized with an inert gas to make the system explosion proof.

Durham, T. F.↗

Investigation of positive shaft seals

Welded metal bellows secondary seals prevent secondary seal leakage with a minimum number of potential leak paths. High performance seal is obtained by controlling the potentially unstable seal-face movements induced by mechanical vibrations and fluid pressure pulsations.

Pfouts, J. O.↗

Watertight low-cost electrical connector

Fabrication is described of waterproof electrical connector assembly for use with Teflon jacketed cables and constructed so that assembly will remain sealed under extreme environmental conditions. Conditions are specified as: pressure from vacuum to atmospheric; temperature from 280 K to 450 K; exposure to saturated steam; and steam suddenly introduced into vacuum.

Dudenhoefer, J. E.↗

Lunar rock splitter/can sealer

A manually powered and operated force generating device fractures lunar material as received from the moon and seals cans containing lunar samples. The rock splitting and can sealing operations are carried out in a vacuum environment. Can sealing is a cold welding process that requires a pressure of 125,000 psi (generating 32,000 lb for the largest can used). The design and modification of the device and the operating experience are described.

Johnson, K. G.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of Eagle-Picher Industries, Incorporated 6.0 ampere-hour, nickel-cadmium spacecraft cells for separator material evaluation

Several groups of nickel cadmium cells were tested for the durability of their separator materials. The cells were rated at 6.0 ampere-hours, and contained double ceramic seals. Two cells in each group were fitted with pressure gauge assemblies. Results are presented for various brands of separator materials.

Harkness, J. D.↗

Advanced life support equipment for nitrogen tetroxide environments

Design constraints considered in an effort to improve the self-contained atmospheric protection ensemble (SCAPE) are discussed. Emphasis is placed on overcoming the hazards of personnel engaged in orbiter crash/rescue operations. Specific topics covered include: suit material permeability; sealing of all suit penetration; and maintaining a positive pressure within the suit.

Bowman, G. H., III↗

Results from tests on a high work transonic turbine for an energy efficient engine

The experimental results of the evaluation of two high work, transonic, single-stage turbines investigated under the Energy Efficient Engine (E3) Program are presented. The objective of the E3 program is to provide an advanced technology base for a new generation of fuel-conservative turbofan engines. A single-stage turbine required fewer cooled airfoils, a reduced number of leakage paths and no interstage seals. These advanced energy efficient engines require high engine pressure ratios resulting in high expansion ratio, transonic, turbine designs which must have high aerodynamic efficiency. The goal of the turbine program is to develop a high pressure turbine that is compatible with the overall engine design and has an uncooled efficiency of 90.8 percent.

Crow, D. E.↗

Replaceable Transfer Tube for High-Pressure Cavities

Set of fittings allows fluid injected into inner chamber, passing through two cavities containing fluids at different high pressures. Injection tube readily replaced, and fittings provide tight seal between cavities after replacement. Tube and fittings made from off-the-shelf parts, and familiar to workers and relatively inexpensive.

Sorensen, D.↗

Design optimization and testing of a pump wear ring labyrinth seal

It has been demonstrated that design optimization of labyrinth seals using the present numerical model is quite beneficial. The results shown include important, but previously unknown effects on the leakage rate, especially that of step height. Further, complete details are given of a very effective seal designed using this technique for the SSME high pressure hydrogen turbopump. Measurements using turbine flow meters revealed that the optimized configuration gives 67 percent leakage reduction over the original design. These measurements also reveal important leakage effects of the axial straining of the stator, which begins during pump start-up.

Rhode, D. L.↗

Evaluation of Rotordynamic Coefficients of Look-through Labyrinths by Means of a Three Volume Bulk Flow Model

To describe the compressible, turbulent flow in a labyrinth seal, a three volume bulk flow model is presented. The conservation equations for mass, momentum, and energy are established in every control volume. A perturbation analysis is performed, yielding zeroth order equations for centric rotor position and first order equations describing the flow field for small rotor motions around the seal center. The equations are integrated numerically. From perturbation pressure, the forces on the shaft and the dynamic coefficients are calculated.

Nordmann, R.↗

Design of a spaceworthy adiabatic demagnetization refrigerator

A spaceworthy adiabatic demagnetization refrigerator (ADR) under development at NASA-Goddard is presented. A baseline model heat switch was tested extensively with an on/off ratio of about 10,000 and a parasitic heat leak of 10 micro-W. Data obtained from the breadboard models were used to design an ADR with improved structural integrity. The core of the ADR is the salt pill which consists of the paramagnetic salt crystal and the thermal bus. When a magnetic field is applied to the salt it forces the alignment of the magnetic moments, thereby decreasing the entropy of the salt. Preliminary tests results showed a net crystal mass of 680 g instead of the expected 740 g, which indicate that there are gaps in the salt pill. A partial fix was accomplished by sealing helium gas in the salt pill at a pressure of 2 bar, which improved the thermal contact during salt magnetization, at about 2 K.

Serlemitsos, A. T.↗