Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Silicon detectors for monitoring neutron beams in n-TOF beamlines

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The dynamics of femtosecond pulsed laser removal of 20 nm Ni films from an interface

The dynamics of femtosecond laser removal of 20 nm Ni films on glass substrates was studied using time-resolved pump-probe microscopy. 20 nm thin films exhibit removal at two distinct threshold fluences, removal of the top 7 nm of Ni above 0.14 J/cm{sup 2}, and removal of the entire 20 nm film above 0.36 J/cm{sup 2}. Previous work shows the top 7 nm is removed through liquid spallation, after irradiation the Ni melts and rapidly expands leading to tensile stress and cavitation within the Ni film. This work shows that above 0.36 J/cm{sup 2} the 20 nm film is removed in two distinct layers, 7 nm and 13 nm thick. The top 7 nm layer reaches a speed 500% faster than the bottom 13 nm layer at the same absorbed fluence, 500–2000 m/s and 300–700 m/s in the fluence ranges studied. Significantly different velocities for the top 7 nm layer and bottom 13 nm layer indicate removal from an interface occurs by a different physical mechanism. The method of measuring film displacement from the development of Newton's rings was refined so it could be shown that the 13 nm layer separates from the substrate within 70 ps and accelerates to its final velocity within several hundred picoseconds. We propose that removal of the bottom 13 nm is consistent with heterogeneous nucleation and growth of vapor at the Ni-glass interface, but that the rapid separation and acceleration of the 13 nm layer from the Ni-glass interface requires consideration of exotic phases of Ni after excitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H{sup −} ion source

A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H{sup −} beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 10{sup 21} m{sup −3}, whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.

43 PARTICLE ACCELERATORS↗

Alternative modeling methods for plasma-based Rf ion sources

Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H{sup −} source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H{sup −} ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models for the SNS source and present simulation results demonstrating plasma evolution over many Rf periods for different plasma temperatures. We perform the calculations in parallel, on unstructured meshes, using finite-volume solvers in order to obtain results in reasonable time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved neutron-gamma discrimination for a {sup 6}Li-glass neutron detector using digital signal analysis methods

A {sup 6}Li-glass scintillator (GS20) based neutron Anger camera was developed for time-of-flight single-crystal diffraction instruments at Spallation Neutron Source. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio (defined as NGD ratio) on the order of 10{sup 4}. The NGD ratios of Anger cameras need to be improved for broader applications including neutron reflectometers. For this purpose, six digital signal analysis methods of individual waveforms acquired from photomultiplier tubes were proposed using (i) charge integration, (ii) pulse-amplitude histograms, (iii) power spectrum analysis combined with the maximum pulse-amplitude, (iv) two event parameters (a{sub 1}, b{sub 0}) obtained from a Wiener filter, (v) an effective amplitude (m) obtained from an adaptive least-mean-square filter, and (vi) a cross-correlation coefficient between individual and reference waveforms. The NGD ratios are about 70 times those from the traditional PHA method. Our results indicate the NGD capabilities of neutron Anger cameras based on GS20 scintillators can be significantly improved with digital signal analysis methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ignition and monitoring technique for plasma processing of multicell superconducting radio-frequency cavities

In this study, an in-situ plasma processing technique has been developed at the Spallation Neutron Source (SNS) to improve the performance of the superconducting radio-frequency (SRF) cavities in operation. The technique uses a low-density reactive neon-oxygen plasma at room-temperature to improve the surface work function, to help remove adsorbed gases on the RF surface and to reduce its secondary emission yield. SNS SRF cavities are six-cell elliptical cavities and the plasma typically ignites in the cell where the electric field is the highest. This article will detail a technique that was developed to ignite and monitor the plasma in each cell of the SNS cavities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel diamond cells for neutron diffraction using multi-carat CVD anvils

Traditionally, neutron diffraction at high pressure has been severely limited in pressure because low neutron flux required large sample volumes and therefore large volume presses. At the high-flux Spallation Neutron Source at the Oak Ridge National Laboratory, we have developed in this paper new, large-volume diamond anvil cells for neutron diffraction. The main features of these cells are multi-carat, single crystal chemical vapor deposition diamonds, very large diffraction apertures, and gas membranes to accommodate pressure stability, especially upon cooling. A new cell has been tested for diffraction up to 40 GPa with an unprecedented sample volume of ~0.15 mm 3 . High quality spectra were obtained in 1 h for crystalline Ni and in ~8 h for disordered glassy carbon. Finally, these new techniques will open the way for routine megabar neutron diffraction experiments.

47 OTHER INSTRUMENTATION↗

A sample holder for simultaneous Raman and neutron vibrational spectroscopy

We have built a sample holder (called a center stick or sample stick) for performing simultaneous Raman and neutron vibrational spectroscopy on samples of material at the VISION neutron vibrational spectrometer of the Spallation Neutron Source at Oak Ridge National Laboratory. This equipment holds material samples in the neutron beam within the cryogenic environment of the VISION spectrometer, allowing for samples to be studied at temperatures as low as 5 K. It also provides the capability for gas to be loaded to or evacuated from the sample while it is loaded at VISION. The optical components for directing and filtering light are located within the cryogenic volume, in physical proximity to the sample. We describe the construction of this sample holder and discuss our first measurements of simultaneous Raman and neutron vibrational spectra. Here, the samples that we report on were of 4-nitrophenol at a temperature of 20 K and of cryogenic hydrogen of a number of different orthohydrogen fractions.

4-nitrophenol↗

AGES: Automated Gas Environment System for in situ neutron powder diffraction

High fluxes available at modern neutron and synchrotron sources have opened up a wide variety of in situ and operando studies of real processes using scattering techniques. This has allowed the user community to follow chemistry in the beam, which often requires high temperatures, gas flow, etc. In this paper, we describe an integrated gas handling system for the general-purpose powder diffraction beamline Powgen at the Spallation Neutron Source. The Automated Gas Environment System (AGES) allows control of both gas flow and temperature (room temperature to 850 °C), while measuring the partial pressure of oxygen and following the effluent gas by mass spectrometry, concurrent with neutron powder diffraction, in order to follow the structural evolution of materials under these conditions. The versatility of AGES is illustrated by two examples of experiments conducted with the system. In solid oxide fuel cell electrode materials, oxygen transport pathways in double perovskites PrBaCo 2 O 5+δ and NdBaCo 2 O 5+δ were elucidated by neutron diffraction measurements under atmosphere with oxygen partial pressures (pO 2 ) of 10 –1 to 10 –4 (achieved using mixtures of nitrogen and oxygen) and temperatures from 575 to 850 °C. In another example, the potential oxygen storage material La 1–x Sr x FeO 3 was measured under alternating flows of 15% CH 4 in N 2 and air (20% O 2 in N 2 ) at temperatures from 135 to 835 °C. As a result, from the oxygen stoichiometry, the optimal composition for oxygen storage was determined.

47 OTHER INSTRUMENTATION↗

The high pressure gas capabilities at Oak Ridge National Laboratory’s neutron facilities

The study of samples subjected to high pressure gas is an important asset in materials research and has consequently been a priority of the sample environment development at the Oak Ridge National Laboratory’s (ORNL) neutron program. Such effort has resulted in the availability of an extensive combination of pressure cells and gas intensifiers (both commercially available and custom made). These resources are available across both neutron facilities at ORNL: the Spallation Neutron Source and the High Flux Isotope Reactor. Current capabilities include, for example, in situ measurements up to 6 kbar and a 3 kbar hydrogen-capable intensifier with a gas recovery feature. In this communication, we will review the existing suite of high pressure gas capabilities, with special emphasis on recent in-house developments. Finally, a number of examples will be presented to illustrate how such capabilities are being deployed on neutron beamlines to enable frontier science.

47 OTHER INSTRUMENTATION↗

RHEGAL: Resistive heating gas enclosure loadframe for in situ neutron scattering

In situ neutron scattering is a powerful tool to reveal materials atomic structural response such as phase transformation, lattice straining, and texture under external stimuli. The advent of a high flux neutron source such as the Spallation Neutron Source (SNS) allows fast measurement in even non-equilibrium conditions, i.e., phase transformation in steels. However, the commercial fast heating apparatus such as commercial physical simulation equipment is not designed for in situ neutron scattering, which limits its application to in situ materials research by using neutrons. Here we present a resistive heating gas enclosure loadframe (RHEGAL) for non-equilibrium phase transformation studies by using in situ neutron scattering, which takes the advantage of high flux neutron sources like SNS. RHEGAL enables fast resistive heating of metal samples to 1200 °C at a rate up to 60 °C/s in an inert atmosphere. It provides both horizontal and vertical positions for scattering optimization. The mechanical loading capability also allows in situ high temperature tension above the oxidation temperature limit. The optimized translucent neutron scattering window by silicon allows both reflection and transmission measurements, making this equipment applicable for neutron diffraction, small angle scattering, and imaging. Furthermore, to demonstrate the fast heating capability, the phase transformations of an example of advanced high strength steel heated at 3 °C/s and 30 °C/s were measured with the VULCAN engineering diffractometer, and the different phase transformation kinetics by neutron diffraction were presented.

47 OTHER INSTRUMENTATION↗

A suite-level review of the neutron powder diffraction instruments at Oak Ridge National Laboratory

The suite of neutron powder diffractometers at Oak Ridge National Laboratory (ORNL) utilizes the distinct characteristics of the Spallation Neutron Source and High Flux Isotope Reactor to enable the measurements of powder samples over an unparalleled regime at a single laboratory. Full refinements over large Q ranges, total scattering methods, fast measurements under changing conditions, and a wide array of sample environments are available. Here, this article provides a brief overview of each powder instrument at ORNL and details the complementarity across the suite. Future directions for the powder suite, including upgrades and new instruments, are also discussed.

47 OTHER INSTRUMENTATION↗

Advances in utilizing event based data structures for neutron scattering experiments

This article strives to expand on existing work to demonstrate advancements in data processing made available using event mode measurements. Most spallation neutron sources in the world have data acquisition systems that provide event recording. The new science that is enabled by utilizing event mode has only begun to be explored. In the past, these studies were difficult to perform because histograms forced dealing with either large chunks of time or a large number of files. With event based data collection, data can be explored and rebinned long after the measurement has completed. This article will review some of the principles of event data and how the method opens up new possibilities for in situ measurements, highlighting techniques that can be used to explore changes in the data. We also demonstrate the statistical basis for determining data quality and address the challenge of determining how long to measure mid-measurement. Lastly, we demonstrate a model independent method of grouping data via hierarchical clustering methods that can be used to improve calibration, reduction, and data exploration.

74 ATOMIC AND MOLECULAR PHYSICS↗

Status of the new SNS injector and external antenna ion source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW required by the planned Proton Power Upgrade (PPU) and Second Target Station (STS) projects. In early 2018 we plan to replace the entire 2.5 MeV injector configuration which includes the ion source, the Low Energy Beam Transport (LEBT) and the Radio Frequency Quadrupole accelerator (RFQ) with one which is currently being tested on a research accelerator called the Beam Test Facility (BTF) located at the SNS facility. This report first provides a description of the new injector: the ion source and the cage enclosure, the new LEBT support structure and the new RFQ. Since fall of 2016, this system has been tested extensively with regard to output beam current, beam persistence, emittance and energy. The results of these experiments employing both internal and external antenna ion sources will be summarized here showing the system to be capable of supporting SNS 1.4 MW operations with a significant margin as well as potentially meeting facility upgrade requirements. This represents a significant performance upgrade over the current SNS front end system with the compromised RFQ and will replace that system in early 2018.

Welton, Robert F.↗

Plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

43 PARTICLE ACCELERATORS↗

Upgrading the LANSCE accelerator with a SNS RF-driven H− ion source

The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in <12 h. LANSCE and SNS are working toward the use of SNS H− ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.

Stockli, Martin P.↗

X-ray imaging of liquid-liquid Mg cavitation

The coupling of dynamic loading platforms with synchrotron light sources have enabled experiments examining void formation in optically opaque materials. Much like spallation in a solid, cavitation occurs when rarefaction waves collide within a liquid. The resulting deformation leads to a complex flow field with numerous voids. It has been suggested that compaction of such a structure may be a significant source of ejecta (i.e. shallow bubble collapse). Experiments imaging supported and unsupported shocks interacting with a free surface in shock melted Mg with synchrotron radiation are presented. Here, the results are used to examine the structure of a cavitation plane that forms in the unsupported case and provide an estimate of the porosity within this region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sample test array and recovery (STAR) platform at the National Ignition Facility

We have developed the Sample Test Array and Recovery (STAR) platform for the National Ignition Facility (NIF) for studying the thermal and hydrodynamic responses of materials in extreme environments. The STAR platform expands the range of obtainable fluences and quadruples the rate that materials experiments can be conducted at the NIF. Example configurations are demonstrated for fluences spanning 0.56–34 J/cm 2 with environmental isolation for post-shot material recovery and inspection and up to 1740 J/cm 2 without isolation, with surface heating rates of up to 2 × 10 14 K/s. Lastly, an example experiment involving thermally driven shock and spallation of aluminum alloy 7075 is briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗