Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Frequency‐Scanning Considerations in Axionlike Dark Matter Spin‐Precession Experiments

Abstract Galactic dark matter may consist of axionlike particles (ALPs) that can be described as an “ultralight bosonic field” oscillating at the ALP Compton frequency. The ALP field can be searched for using nuclear magnetic resonance (NMR), where resonant precession of spins of a polarized sample can be sensitively detected. The ALP mass to which the experiment is sensitive is scanned by sweeping the bias magnetic field. The scanning either results in detection of ALP dark matter or rules out ALP dark matter with sufficiently strong couplings to nuclear spins over the range of ALP masses corresponding to the covered span of Larmor frequencies. In this work, scanning strategies are analyzed with the goal of optimizing the parameter‐space coverage via a proper choice of experimental parameters (e.g., the effective transverse relaxation time).

Zhang, Yuzhe (ORCID:0009000660829066)↗

Speedup of UEDGE Parameter Scans Using Machine-Learning Optimized OpenMP Parallelization and a Continuation Solver

This article presents the OpenMP parallelization of the preconditioning Jacobian assembly and right‐hand side residual evaluation in UEDGE. A continuation algorithm, utilizing the internal NKSOL implicit Jacobian‐Free Newton‐Krylov solver to efficiently scan physical parameters, is also presented. The implemented parallelization reduces the computational time for a benchmark scan run on 32 threads by compared to the serial version when using trained random forest regression models to identify the optimal decomposition of the system of equations. Random forest regression models applied to the UEDGE time‐dependent and continuation solver algorithms did not yield meaningful improvement in computational performance. A benchmark DIII‐D gas injection rate scan in the 0.35–0.75 kA interval, performed on a test cluster using the parallelized code and continuation solver, produced 1066 steady‐state solutions with a 22 s average wall‐clock computational time per steady‐state solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Functionalization of Scanning Probe Tips with Epitaxial Semiconductor Layers

Functionalized scanning probe tips hold great promise for the controlled delivery of signals from and to selected nanoscale volumes. Here, a new nanotechnological approach for the functionalization of scanning probe tips is presented, targeting the transfer of the optical, electrical, thermal, or chemical properties of precisely characterized epitaxial semiconductor layers to the nanoscale probe tip. Homogeneously doped, strain‐relaxed heteroepitaxial germanium layers, several micrometers thick, are first grown on silicon wafers by low‐energy plasma‐enhanced chemical vapor deposition and then employed to functionalize the probe apex. This choice of materials and growth technique enables the future scalability of the tip functionalization process toward high production volumes. The fabricated probe tips are investigated in a transmission electron microscope, revealing that the crystal structure and the homogeneous doping level of the epitaxial layers are unchanged after the probe‐tip functionalization process. These doped‐germanium tips are also tested as nanoemitters of light at telecom wavelengths (1.55 µm) and applied as scattering probes for near‐field mid‐infrared microscopy. The reported combination of heteroepitaxial growth and a nanofabrication approach can be extended to a variety of epitaxial materials, thus enabling a new generation of scanning probes for the investigation of nanostructured materials and devices.

Giliberti, Valeria↗

Impact of simulated reduced injected dose on the assessment of amyloid PET scans

To investigate the impact of reduced injected doses on the quantitative and qualitative assessment of the amyloid PET tracers [ 18 F]flutemetamol and [ 18 F]florbetaben. Cognitively impaired and unimpaired individuals (N = 250, 36% Aβ-positive) were included and injected with [ 18 F]flutemetamol (N = 175) or [ 18 F]florbetaben (N = 75). PET scans were acquired in list-mode (90–110 min post-injection) and reduced-dose images were simulated to generate images of 75, 50, 25, 12.5 and 5% of the original injected dose. Images were reconstructed using vendor-provided reconstruction tools and visually assessed for Aβ-pathology. SUVRs were calculated for a global cortical and three smaller regions using a cerebellar cortex reference tissue, and Centiloid was computed. Absolute and percentage differences in SUVR and CL were calculated between dose levels, and the ability to discriminate between Aβ- and Aβ + scans was evaluated using ROC analyses. Finally, intra-reader agreement between the reduced dose and 100% images was evaluated. At 5% injected dose, change in SUVR was 3.72% and 3.12%, with absolute change in Centiloid 3.35CL and 4.62CL, for [ 18 F]flutemetamol and [ 18 F]florbetaben, respectively. At 12.5% injected dose, percentage change in SUVR and absolute change in Centiloid were < 1.5%. AUCs for discriminating Aβ- from Aβ + scans were high (AUC ≥ 0.94) across dose levels, and visual assessment showed intra-reader agreement of > 80% for both tracers. This proof-of-concept study showed that for both [ 18 F]flutemetamol and [ 18 F]florbetaben, adequate quantitative and qualitative assessments can be obtained at 12.5% of the original injected dose. However, decisions to reduce the injected dose should be made considering the specific clinical or research circumstances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of the scanning strategy on the formation of residual stresses in additively manufactured Ti-6Al-4V

During the laser-powder bed fusion (L-PBF) process, high laser intensities, short interaction times and highly localized heat input drive large thermal gradients that result in a state of high residual stresses. Generally, the residual stresses that develop during the L-PBF process can compromise the performance of the component. Up to now, the literature has indicated that the magnitude of the residual stresses can be affected by various process parameters. In this study, all process parameters such as laser power and speed are held fixed and the focus is solely on the effect of the laser scan strategy on the three-dimensional residual stress state of L-PBF metallic components. Four Ti-6Al-4V bridge shaped components were built using island and continuous scanning patterns parallel and offset 45° from the sample axes. High-energy X-ray diffraction was used to determine the residual stress field in each of the components. Two of them were re-measured after being partially removed from the build plate. The assumptions implicit in diffraction measurements of stress are reviewed and discussed in depth because the unique microstructure associated with L-PBF Ti-6Al-4V renders the validity of those assumptions uncertain. Specifically, additional data was collected and analyzed to evaluate the relationship between grain scale and macroscopic scale stresses. The observed residual stresses were large, ½ to ¾ of the yield strength, particularly the build direction stresses near the lateral edges of the bridges. Here in this work, the higher stresses were observed in the bridges built via the island scan strategies, chiefly near the edges of the parts.

36 MATERIALS SCIENCE↗

Role of scan strategies and heat treatment on grain structure evolution in Fe-Si soft magnetic alloys made by laser-powder bed fusion

A major goal in printing soft magnetic Fe-Si steels using additive manufacturing is to take advantage of the potential for complex geometric designs and site-specific grain control. One major step in the processing of these alloys is understanding how processing parameters might impact how the as-built microstructure responds to annealing (i.e. the annealing response). The impact of scan strategy on the annealing response for thin wall geometries is specifically explored. Two scan strategies were explored for a thin wall geometry that produced a strongly columnar grain structure and equiaxed grain structure. Additionally, samples from both scan strategies annealed at 1200 °C showed a marked difference in annealing response with the more equiaxed sample seeing full recrystallization and grain growth, while the more columnar grain structure saw little change in microstructure. After analysis through characterization techniques and thermal-mechanical simulations Differences in internal energy within the grains were ruled out because calculated GND density values were similar for both samples. The formation of secondary particles was ruled out as a contributing factor due to the type of oxide formations and their size. It was concluded that the contributing factor to the difference in the annealing response were a difference in the resulting grain size and the density of high angle grain boundaries. These two differences were largely attributed to differences in the thermal gradient conditions due to grains preferentially growing in the direction of the steepest thermal gradient.

36 MATERIALS SCIENCE↗

Uncertainty quantification of the convolutional neural networks on permeability estimation from micro-CT scanned sandstone and carbonate rock images

Rock permeability is one of the most crucial properties affecting subsurface fluid flow behaviors. To accurately and robustly estimate the permeability, Digital Rock Physics, including micro-CT scanning technology and direct flow simulations on scanned images, has prevailed in recent years. Besides, machine learning techniques such as convolutional neural networks (CNNs) have been widely adopted and achieved success in permeability estimations directly from rock images. However, existing ML methods used for permeability estimation from rock images lack uncertainty quantification that causes unreliable predictions and overconfident estimations on out-of-distribution (OOD) samples. Here, in this work, we propose a PI3NN-CNN framework to address this problem. PI3NN-CNN consists of a CNN model for absolute permeability estimation and a PI3NN method to quantify the estimation uncertainty. It is able to quantify the uncertainty for in-distribution (InD) data with a desired confidence level, and identify OOD samples to avoid overconfident predictions. We demonstrate the method using micro-CT scanned images from two sandstone and two carbonate rocks. We found that PI3NN-CNN generates accurate predictions for InD samples, while producing high-quality prediction uncertainties regardless of the prediction accuracy. Meanwhile, PI3NN-CNN identifies OOD samples using its special network initialization scheme. The unique feature of PI3NN-CNN makes it applicable to more complex real-world image-based data for robust learning and predictions without overconfident estimations when the ground-truth information is unavailable.

58 GEOSCIENCES↗

Postoperative Spot-Scanning Proton Radiation Therapy for Chordoma and Chondrosarcoma in Children and Adolescents: Initial Experience at Paul Scherrer Institute

Purpose: To evaluate postoperative spot-scanning proton radiation therapy (PT) and intensity-modulated PT (IMPT) for chordoma and chondrosarcoma in pediatric patients. Methods and Materials: Between 2000 and 2005, 10 patients (six male patients, four female patients; six chordomas, four chondrosarcomas), aged 10-20 years (median, 16 years), were treated at our institute. Tumor sites were in the brain (one case), skull base (five cases), cervical (three cases), and lumbar spine (one case). Three children had complete resections. In seven children, resection was incomplete, leaving residual tumor behind (range, 2.3-46.3 mL). PT was delivered using spot scanning, with (three patients) or without (seven patients) IMPT. Total dose was 74.0 cobalt Gray equivalents (CGE) for chordoma, and 63.2-68.0 CGE for chondrosarcoma (median, 66.0), depending on histopathological grading and whether the patient had concurrent chemotherapy. Results: Median follow-up time was 36 months (range, 8-77 months). Radiation treatment was well tolerated. All patients remained failure-free at their last follow-up. Late adverse events were reported in three patients and were mild (neurosensory in one patient; alopecia and hypoaccusis in one patient) to moderate (one patient, Grade 2 pituitary insufficiency). Conclusions: Postoperative spot-scanning PT, delivered in combination with and without IMPT, for chordoma and chondrosarcoma in children and adolescents was tolerated without unacceptable adverse event and initial outcome is perfectly satisfactory in this small cohort. Longer follow-up time and larger cohort are needed to more fully assess tumor control, adverse events, as well as functional and cosmetic outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Prostate Shifts: Review of 1870 Computed Tomography (CT) Scans Obtained During Image-Guided Radiotherapy Using CT-on-Rails for the Treatment of Prostate Cancer

Purpose: To review 1870 CT scans of interfractional prostate shift obtained during image-guided radiotherapy. Methods and Materials: A total of 1870 pretreatment CT scans were acquired with CT-on-rails, and the corresponding shift data for 329 patients with prostate cancer were analyzed. Results: Of the 1870 scans reviewed, 44% required no setup adjustments in the anterior-posterior (AP) direction, 14% had shifts of 3-5 mm, 29% had shifts of 6-10 mm, and 13% had shifts of >10 mm. In the superior-inferior direction, 81% had no adjustments, 2% had shifts of 3-5 mm, 15% had shifts of 6-10 mm, and 2% had shifts of >10 mm. In the left-right direction, 65% had no adjustment, 13% had shifts of 3-5 mm, 17% had shifts of 6-10 mm, and 5% had shifts of >10 mm. Further analysis of the first 66 consecutive patients divided into three groups according to body mass index indicates that the shift in the AP direction for the overweight subgroup was statistically larger than those for the control and obese subgroups (p < 0.05). The interfractional shift in the lateral direction for the obese group (1 SD, 5.5 mm) was significantly larger than those for the overweight and control groups (4.1 and 2.9 mm, respectively) (p < 0.001). Conclusions: These data demonstrate that there is a significantly greater shift in the AP direction than in the lateral and superior-inferior directions for the entire patient group. Overweight and obese patient groups show a significant difference from the control group in terms of prostate shift.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness and Safety of Spot Scanning Proton Radiation Therapy for Chordomas and Chondrosarcomas of the Skull Base: First Long-Term Report

Purpose: To evaluate effectiveness and safety of spot-scanning-based proton radiotherapy (PT) in skull-base chordomas and chondrosarcomas. Methods and Materials: Between October 1998 and November 2005, 64 patients with skull-base chordomas (n = 42) and chondrosarcomas (n = 22) were treated at Paul Scherrer Institute with PT using spot-scanning technique. Median total dose for chordomas was 73.5 Gy(RBE) and 68.4 Gy(RBE) for chondrosarcomas at 1.8-2.0 Gy(RBE) dose per fraction. Local control (LC), disease specific survival (DSS), and overall survival (OS) rates were calculated. Toxicity was assessed according to CTCAE, v. 3.0. Results: Mean follow-up period was 38 months (range, 14-92 months). Five patients with chordoma and one patient with chondrosarcoma experienced local recurrence. Actuarial 5-year LC rates were 81% for chordomas and 94% for chondrosarcomas. Brainstem compression at the time of PT (p = 0.007) and gross tumor volume >25 mL (p = 0.03) were associated with lower LC rates. Five years rates of DSS and OS were 81% and 62% for chordomas and 100% and 91% for chondrosarcomas, respectively. High-grade late toxicity consisted of one patient with Grade 3 and one patient with Grade 4 unilateral optic neuropathy, and two patients with Grade 3 central nervous system necrosis. No patient experienced brainstem toxicity. Actuarial 5-year freedom from high-grade toxicity was 94%. Conclusions: Our data indicate safety and efficacy of spot-scanning based PT for skull-base chordomas and chondrosarcomas. With target definition, dose prescription and normal organ tolerance levels similar to passive-scattering based PT series, complication-free, tumor control and survival rates are at present comparable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Quality Assurance for Prostate Cancer Patients Receiving Spot Scanning Proton Therapy Using Single-Field Uniform Dose

Purpose: To describe our experiences with patient-specific quality assurance (QA) for patients with prostate cancer receiving spot scanning proton therapy (SSPT) using single-field uniform dose (SFUD). Methods and Materials: The first group of 249 patients with prostate cancer treated with SSPT using SFUD was included in this work. The scanning-beam planning target volume and number of monitor units were recorded and checked for consistency. Patient-specific dosimetric measurements were performed, including the point dose for each plan, depth doses, and two-dimensional (2D) dose distribution in the planes perpendicular to the incident beam direction for each field at multiple depths. The {gamma}-index with 3% dose or 3-mm distance agreement criteria was used to evaluate the 2D dose distributions. Results: We observed a linear relationship between the number of monitor units and scanning-beam planning target volume. The difference between the measured and calculated point doses (mean {+-} SD) was 0.0% {+-} 0.7% (range, -2.9% to 1.8%). In general, the depth doses exhibited good agreement except at the distal end of the spread-out Bragg peak. The pass rate of {gamma}-index (mean {+-} SD) for 2D dose comparison was 96.2% {+-} 2.6% (range, 90-100%). Discrepancies between the measured and calculated dose distributions primarily resulted from the limitation of the model used by the treatment planning system. Conclusions: We have established a patient-specific QA program for prostate cancer patients receiving SSPT using SFUD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spot-Scanning-Based Proton Therapy for Extracranial Chordoma

Purpose: To evaluate effectiveness and safety of spot-scanning-based proton-radiotherapy (PT) for extracranial chordomas (ECC). Methods and Material: Between 1999-2006, 40 patients with chordoma of C-, T-, and L-spine and sacrum were treated at Paul Scherrer Institute (PSI) with PT using spot-scanning. Median patient age was 58 years (range, 10-81 years); 63% were male, and 36% were female. Nineteen patients (47%) had gross residual disease (mean 69 cc; range, 13-495 cc) before PT, and 21 patients (53%) had undergone prior titanium-based surgical stabilization (SS) and reconstruction of the axial skeleton. Proton doses were expressed as Gy(RBE). A conversion factor of 1.1 was used to account for higher relative biological effectiveness (RBE) of protons compared with photons. Mean total dose was 72.5 Gy(RBE) [range, 59.4-75.2 Gy(RBE)] delivered at 1.8-2.0 Gy(RBE) dose per fraction. Median follow-up time was 43 months. Results: In 19 patients without surgical stabilization, actuarial local control (LC) rate at 5 years was 100%. LC for patients with gross residual disease but without surgical stabilization was also 100% at 5 years. In contrast, 12 failures occurred in 21 patients with SS, yielding a significantly decreased 5-year LC rate of 30% (p = 0.0003). For the entire cohort, 5-year LC rates were 62%, disease-free survival rates were 57%, and overall survival rates were 80%. Rates were 100% for patients without SS. No other factor, including dosimetric parameters (V95, V80) were predictive for tumor control on univariate analysis. Conclusion: Spot-scanning-based PT at PSI delivered subsequently to function-preserving surgery for tumor debulking, decompression of spinal cord, or biopsy only is safe and highly effective in patients with ECC without major surgical instrumentation even in view of large, unresectable disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robustness Against Interfraction Prostate Movement in Scanned Ion Beam Radiation Therapy

Purpose: To assess the robustness of scanned ion beam treatment plans against the interfraction internal target motion and evaluate the limits of validity of target-based isocenter realignment for prostate cancer radiation therapy. Methods and Materials: For 12 prostate patients, scanned beam carbon ion treatment plans were prepared using 2 lateral opposed beams and the raster scanning technique with different clinical target volume (CTV) to planning target volume (PTV) margins (2-10 mm). Internal target motion of 2-15 mm in anteroposterior (AP), superoinferior (SI), and left-to-right (LR) directions was simulated by displacing the CTV contours with respect to the computed tomography data. The plans were recalculated with and without target-based isocenter realignment and the CTV coverage was assessed. Results: For CTV shifts within the applied planning margin, the CI-98% is greater than 98.0%, both with and without isocenter realignment. Without realignment, because of the sharp lateral gradients, the CI-98% shows rapid fall as soon as the target shift exceeds the applied planning margin for all displacement directions. With isocenter realignment, the coverage improves notably for shifts in AP and SI directions and the CI-98% is restored to >95.0% for plans optimized with a 2-mm margin, >97% with a 3-mm margin, and >98% with larger margins. For large corrections, predominately in AP direction, cold spots in the CTV may occur. Their magnitude is dependent on the patients' individual anatomies. Conclusions: Within the physiological limits of internal prostate movement, target-based isocenter realignment results in improved CTV coverage for shifts in AP and SI directions exceeding the applied planning margin. Assuming optimal patient setup reproducibility (eg, immobilization, setup error correction, patient preparation protocols), hence negligible interfraction bone and soft-tissue variations, changes in traversed densities resulting from target-based realignment applied with a reduced planning margin do not induce significant dose deterioration in most of the cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Supine Craniospinal Irradiation Using a Proton Pencil Beam Scanning Technique Without Match Line Changes for Field Junctions

Purpose: To propose and validate a craniospinal irradiation approach using a proton pencil beam scanning technique that overcomes the complexity of the planning associated with feathering match lines. Methods and Materials: Ten craniospinal irradiation patients had treatment planned with gradient dose optimization using the proton pencil beam scanning technique. The robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in the longitudinal direction and was compared with the original nonshifted plan with metrics of conformity number, homogeneity index, and maximal cord doses. An anthropomorphic phantom study using film measurements was carried out on a plan with 5-cm junction length. To mimic setup errors in the phantom study, fields were recalculated with isocenter shifts of 1, 3, 5, and 10 mm longitudinally, and compared with the original plans and measurements. Results: Uniform dose coverage to the entire target volumes was achieved using the gradient optimization approach with averaged junction lengths of 6.7 ± 0.5 cm. The average conformity number and homogeneity index equaled 0.78 ± 0.03 and 1.09 ± 0.01, respectively. Setup errors of 3 mm per field (6 mm in worst-case scenario) caused on average 4.6% lower conformity number 2.5% higher homogeneity index and maximal cord dose of 4216.1 ± 98.2 cGy. When the junction length was 5 cm or longer, setup errors of 6 mm resulted in up to 12% dosimetric deviation. Consistent results were reached between film measurements and planned dose profiles in the junction area. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the proton craniospinal irradiation treatment with matched proton pencil beam scanning fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust to longitudinal setup errors compared to conventional feathering methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applying a difference ratio method in spin-polarized scanning tunneling microscopy to determine crystalline anisotropies and antiferromagnetic spin alignment in Cr(0 0 1) c(2 $\times$ 2)

Here, we present spin-polarized scanning tunneling microscopy results for 8 micrometer thick, chromium (0 0 1)-oriented thin films deposited using molecular beam epitaxy on MgO(0 0 1) substrates, achieving a smooth, atomically-stepped staircase morphology. The c(2 × 2) surface structure of the Cr(0 0 1) surface was found via atomically-resolved scanning tunneling microscopy images and dI/dV spectroscopy. A practical method of interpreting spin-polarized scanning tunneling microscopy dI/dV images was developed and applied to the c(2 × 2) Cr(0 0 1) surface structure. A 180° spin reversal between atomic layers, characteristic of a topological, layer-wise antiferromagnetic spin structure, was quantitatively verified. In addition, the spin anisotropy directions for 3 different antiferromagnetic, atomic staircase domains occurring on the c(2 × 2) surface were quantitatively determined to coincide with the [1 0 0], [0 1 0], and [1 1 0] crystallographic axes of chromium

36 MATERIALS SCIENCE↗

Microstructural development of electron beam processed Al-3Ti-1Sc alloy under different electron beam scanning speeds

A systematic study has been made of the microstructural development in as-cast 30 mm thick Al-3Ti-1Sc (wt%) plate samples that were processed by electron beam (EB) melting at different scanning speeds of 3, 5, 8, 12, 15 and 20 mm/s. The composition of the alloy is designed to capitalize on the potential for significantly extended solubility values of both Sc and Ti in Al when cooled at high cooling rates. The resulting microstructures are characterised using transmission electron microscopy (TEM) and other analytical means, assisted with Thermo-Calc predictions and Vicker's microhardness measurements. EB scanning speed plays a key role in determining the phase formation and microstructural development in the Al-3Ti-1Sc alloy when the beam is applied an accelerating voltage of 50 kV and a current of 30 μA. The major microstructural features in the re-solidified zone include (i) the formation of the primary tetragonal Al{sub 3}(Ti,Sc) phases and their retention or subsequent transformation to stable cubic Al{sub 3}(Ti,Sc) phases; (ii) the complete suppression of the primary tetragonal Al{sub 3}(Ti,Sc) phases at the scanning speed of 20 mm/s; and (iii) the formation of cubic Al{sub 3}(Ti,Sc) precipitates in the α(Al) matrix supersaturated with both Sc and Ti. These experimental findings are informative for both EB processing of Al-Ti-Sc alloys and the design of new Al alloys for additive manufacturing processes.

36 MATERIALS SCIENCE↗

Third-order nonlinear optical properties of Bi{sub 2}S{sub 3} nanocrystals doped in sodium borosilicate glass studied with Z-scan technique

Research highlights: {yields} Sol-gel method to realize the synthesis of Bi{sub 2}S{sub 3} nanocrystals doped in the glass. {yields} High dispersion and narrow distribution of Bi{sub 2}S{sub 3} nanocrystals in the glass. {yields}Z-scan technique employed for nonlinear optical properties of the glass. {yields} Observation that an obvious third-order optical nonlinear properties in the glass. -- Abstract: The third-order nonlinear optical properties of Bi{sub 2}S{sub 3} nanocrystals doped in sodium borosilicate glass are measured by Z-scan technique. The microstructures of the glass are characterized by means of X-ray diffraction, transmission electron microscopy, scanning transmission electron microscopy, energy dispersion X-ray spectra, and high-resolution transmission electron microscopy. The results show that the Bi{sub 2}S{sub 3} nanocrystals ranging from 10 to 30 nm are determined to be of the orthorhombic crystalline phase, and the third-order optical nonlinear refractive index {gamma}, absorption coefficient {beta}, and susceptibility {chi}{sup (3)} of the glass are determined to be 2.56 x 10{sup -16} m{sup 2} W{sup -1}, 4.13 x 10{sup -10} mW{sup -1}, and 1.43 x 10{sup -10} esu, respectively.

36 MATERIALS SCIENCE↗