Impedance matched superconducting nanowire photodetector for single- and multi-photon detection

Conventional readout of a superconducting nanowire single-photon detector (SNSPD) sets an upper bound on the output voltage to be the product of the bias current and the load impedance, IB×Zload, where Zload is limited to 50Ω in standard RF electronics. This limit is broken/exceeded by interfacing the 50Ω load and the SNSPD using an integrated superconducting transmission line taper. The taper is a transformer that effectively loads the SNSPD with high impedance without latching. The taper increases the amplitude of the detector output while preserving the fast rising edge. Using a taper with a starting width of 500 nm, a 3.6× higher pulse amplitude, 3.7× faster slew rate, and 25.1 ps smaller timing jitter was observed. The taper also makes the detector's output voltage sensitive to the number of photon-induced hotspots and enables photon number resolution.

Zhu, Di↗

Progress on Frequency-Domain Multiplexing Development for High Count rate X-ray Microcalorimeters

Frequency-domain multiplexing is one of the candidates for the readout of TES-based imaging microcalorimeter arrays for applications such as IXO. The readout system uses the TES as the modulating element, a bandpass LC filter to separate the signals in frequency space, and a customized SQUID with a low input inductance and high dynamic range as cryogenic amplifier. We will show the latest experimental progress on the development of this system. The paper concentrates on our first results on multiplexing 2-7 channels at bias frequencies below 5 MHz using discrete LC filters and baseband feedback electronics. In addition to that, the scalability of the system will be addressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalability, Scintillation Readout and Charge Drift in a Kilogram Scale Solid Xenon Particle Detector

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualizing the bidirectional optical transfer function for near-field enhancement in waveguide coupled plasmonic transducers

Here, we report visualizations of the bidirectional near-field optical transfer function for a waveguide-coupled plasmonic transducer as a metrology technique essential for successful development for mass-fabricated near-field devices. Plasmonic devices have revolutionized the observation of nanoscale phenomena, enabling optical excitation and readout from nanoscale regions of fabricated devices instead of as limited by optical diffraction. Visualizations of the plasmonic transducer modes were acquired both by local near-field excitation of the antenna on the front facet of a waveguide using the focused electron beam of a scanning electron microscope as a probe of the near-field cathodoluminescence during far-field collection from the back facet of the waveguide, and by local mapping of the optical near-field for the same antenna design using scattering scanning near-field optical microscopy as a probe of the near-field optical mode density for far-field light focused into the back facet of the waveguide. Strong agreement between both measurement types and numerical modeling was observed, indicating that the method enables crucial metrological comparisons of as fabricated device performance to as-modeled device expectations for heat-assisted magnetic recording heads, which can be extended to successful development of future near-field-on-chip devices such as optical processor interconnects.

42 ENGINEERING↗

Fast electron spin resonance controlled manipulation of spin injection into quantum dots

In our spin-injection light-emitting diodes, electrons are spin-polarized in a semimagnetic ZnMnSe spin aligner and then injected into InGaAs quantum dots. The resulting electron spin state can be read out by measuring the circular polarization state of the emitted light. Here, we resonantly excite the Mn 3d electron spin system with microwave pulses and perform time-resolved measurements of the spin dynamics. We find that we are able to control the spin polarization of the injected electrons on a microsecond timescale. This electron spin resonance induced spin control could be one of the ingredients required to utilize the quantum dot electrons or the Mn spins as qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A blessing in disguise : Characterisations of ProtoDUNE photon showers for neutrino measurements in DUNE

There are few areas of particle physics as open to new discoveries as the neutrino sector. Although these particles are among the most abundant in the universe, their weak coupling to ordinary matter makes them a challenge to study. The Deep Underground Neutrino Experiment (DUNE) is an upcoming precision experiment in neutrino physics planned to be built between Illinois and South Dakota in the US. The most powerful neutrino beam in the world will be aimed at the largest liquid argon time projection chamber in the world through 1300 km of solid rock. In order to prototype this detector, a scale model was constructed and operated at CERN in 2018 called ProtoDUNE. This thesis presents three studies performed on this detector. The first concerns the readout of detector data by the FELIX data acquisition system, as well as compression studies performed on the same data. The second study concerns the identification of photons created in neutral pion decay, which form a major background to neutrino-produced electrons. The distinction between electrons and photons is based on the differing energy deposition in the initial part of the particle showers they produce. The third study concerns the energy reconstruction of particle showers in the detector. Although photon showers created from neutral pion decay are a major background to the eventual neutrino signal, they have a known energy profile and can thus be used to calibrate the energy reconstruction of particle showers in general, a vital requirement for DUNE’s physics goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Blessing in Disguise -- Characterisations of ProtoDUNE photon showers for neutrino measurements in DUNE

This thesis presents three studies performed on ProtoDUNE, a prototype liquid argon time projection chamber for the Deep Underground Neutrino Experiment (DUNE). The first study concerns the readout of detector data by the FELIX data acquisition system, as well as compression studies performed on the same data. The second study concerns the identification of photons created in neutral pion decay, which form a major background to neutrino-produced electrons. The distinction between electrons and photons is based on the differing energy deposition in the initial part of the particle showers they produce. The third study concerns the energy reconstruction of these particle showers in the detector. They have a known energy profile and can thus be used to calibrate the energy reconstruction of particle showers in general, a vital requirement for DUNE’s physics goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gamma-ray superconducting detector based on Abrikosov vortices: Principle of operation

The high atomic number of some superconducting elements such as niobium (Z=41) and tantalum (Z=73) and a high material thickness (e.g., t=300 mum) are emphasized as essential properties for development of a gamma-ray solid state detector with high intrinsic detection efficiency in the energy range up to 100 keV. To exploit these properties, a new detection principle based on the interaction of a single gamma-ray photon with Abrikosov vortex is proposed. The interaction of gamma-ray photon with a superconductor is discussed in terms of the photoelectric absorption and a hot-spot formation, the last acts as a short-time pinning center on an Abrikosov vortex and activates its motion, namely, a jump or damped vibration. Both types of vortex motion lead to variation (either static or dynamic) in the magnetic field on the absorber surface. The high sensitivity of the Josephson tunneling to weak magnetic field can be exploited for revealing the magnetic field variation and to make the readout of the detector. Main intrinsic properties of a gamma-ray detector based on Abrikosov vortices are evaluated, including the possibility to measure the energy deposited in the detector. A single Josephson tunnel junction configuration or a superconducting quantum interference device (SQUID) configuration is proposed and discussed as possible realization of working gamma-ray detector both in the counter operation mode and in the radiation spectroscopy operation mode.

36 MATERIALS SCIENCE↗

Construction and response of a highly granular scintillator-based electromagnetic calorimeter

Here, a highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X 0 depth and 180 × 180 mm 2 transverse dimensions was constructed, consisting of 2160 individually read out 10 × 45 × 3 mm 3 scintillator strips. This prototype was tested using electrons of 2–32 Ge V at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be ( 12 . 5 ± 0 . 1 ( stat. ) ± 0 . 4 ( syst. ) ) % / E [ Ge V ] ⊕ ( 1 . 2 ± 0 . 1 ( stat. ) - 0 . 7 + 0 . 6 ( syst. ) ) % , where the uncertainties correspond to statistical and systematic sources, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nucleon structure studies: DVCS on polarised protons with the CLAS12 experiment, and development of Micromegas detectors for EIC

The quark and gluon structure of nucleons is crucial for understanding the origin of their mass and spin. This information is encoded in structure function such as Generalised Parton Distributions (GPDs), which provide a three-dimensional picture of the nucleon in terms of its constituents. Deeply Virtual Compton Scattering (DVCS) offers the most direct access to GPDs, but their extraction requires high-precision measurements of multiple observables over a wide kinematic range. In 2022 and 2023 the CLAS12 experiment at Jefferson Lab (JLab) collected data from polarised electron scattering on a longitudinally polarised proton target, enabling the first measurement of polarised DVCS asymmetries at JLab 12GeV kinematics. This thesis will present preliminary measurement of the beam, target and double spin DVCS asymmetries from the CLAS12 polarised proton target data. Nucleon structure studies will also constitute a major part of the physics program at the future Electron Ion Collider (EIC). The development of the first detector at the EIC is ongoing and it requires light Micro-Pattern Gaseous Detectors (MPGDs) for its tracking system. This thesis further reports initial tests of Micromegas MPGDs with a two-dimensional readout developed for EIC.

Polcher, Samy [Univ. Paris-Saclay, Gif-sur-Yvette ↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

Electrochemical Characterization of Photo-Driven Hole-Scavenging by Cadmium Sulfide Quantum Dot-Nitrogenase Biohybrid Complexes

Light-driven biohybrid systems that couple semiconductor nanocrystals with enzymes offer a promising strategy for solar-to-chemical energy-conserving reduction reactions, yet are often limited by inefficient hole scavenging. Hole scavenging is critical for maintaining charge separation in the light-absorbing electron donor molecule and, thus, for sustaining catalytic turnover, making quantification essential to improving system efficiency. Here, we introduce a photoelectrochemical approach for real-time monitoring of hole scavenging in cadmium sulfide (CdS) quantum dot (QD)-nitrogenase MoFe protein biohybrids that catalyze the reduction of H+ and N2. Using hydroquinone (HQ) as the sacrificial electron donor (SED), oxidation of HQ to benzoquinone (BQ) by photogenerated valence-band holes is coupled to the electrochemical reduction of BQ at an electrode, enabling quantification of the hole-scavenging reaction via chronoamperometry. This approach provides a continuous, real-time readout of charge-transfer dynamics under illumination. Systematic variation of light intensity and donor concentration reveals that hole scavenging scales with photon flux and exhibits a non-linear dependence on SED concentration, with an optimum at intermediate HQ concentrations. These results establish chronoamperometry as a powerful tool for probing photoinduced charge transfer, advancing the quantitative understanding of hole-scavenging in biohybrid systems, and offering a generalizable framework for optimizing solar-driven biocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of the ALICE Electromagnetic Calorimeter

The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010–2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the detector, the procedures for data taking, reconstruction, and validation are explained. The methods used for the calibration and various derived corrections are presented in detail. Subsequently, the capabilities of the calorimeter to reconstruct and measure photons, light mesons, electrons and jets are discussed. The performance of the calorimeter is illustrated mainly with data obtained with test beams at the Proton Synchrotron and Super Proton Synchrotron or in proton-proton collisions at $\sqrt{s}$ = 13 TeV, and compared to simulations.

47 OTHER INSTRUMENTATION↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

The Oscura Experiment

The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measurement of the energy and timing resolution of GlueX Forward Calorimeter using an electron beam

The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are near the lower-limits of the design sensitivity, the fractional energy resolution was measured to range from 20% to 14%, which meets the design goals. The use of custom 250 MHz flash ADCs for readout allowed precise measurements of signal arrival times. The detector achieved timing resolutions of 0.38 ns for a single 100 mV pulse, which will allow timing discrimination of photon beam bunches and out-of-time background during the operation of the GlueX detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments

The recent development of high-repetition rate x-ray free electron lasers (FEL), makes it possible to perform x-ray scattering and emission spectroscopy measurements from thin foils or gasses heated to high-energy density conditions by integrating over many experimental shots. Since the expected signal may be weaker than the typical CCD readout noise over the region-of-interest, it is critical to the success of this approach to use a detector with high-energy resolution so that single x-ray photons may be isolated. We describe a dual channel x-ray spectrometer developed for the Atomic and Molecular Optics endstation at the Linac Coherent Light Source (LCLS) for x-ray spectroscopy near the K-edge of aluminum. The spectrometer is based on a pair of curved PET (002) crystals coupled to a single pnCCD detector which simultaneously measures x-ray scattering and emission in the forward and backward directions. Furthermore, the signals from single x-ray photons are accumulated permitting continuous single-shot acquisition at 120 Hz.

42 ENGINEERING↗

Charge-Pump Detector for X-ray Correlation Spectroscopy

A detector for the X-ray Correlation Spectroscopy (XCS) instrument at the Linac Coherent Light Source (LCLS) in Stanford (CA) is being developed at Brookhaven National Laboratory (BNL). The LCLS is the first operational X-ray free electron laser. It provides extremely bright coherent laser-like X-ray pulses with energy up to 8 keV, shorter than 100 fs and with a repetition rate that will go up to 120 Hz. An ideal detector for XCS experiments should cover a large angular range with high efficiency and provide a proper resolution to resolve the speckle. The requirement for dynamic range is not particularly stringent while a fast readout is needed. In particular, the Charge Pump Detector has to be highly efficient at the energy of 8 keV, provide a dynamic range of 100 photons and a readout noise much better than one photon. The 1024 x 1024 pixels have to be read within the repetition rate of the laser pulses, that is faster than 8 ms. The pixel size of 56 {micro} m x 56 {micro}m is a compromise between charge sharing and small pixel. Working principle and details of the detector will be discussed.

43 PARTICLE ACCELERATORS↗