Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The GSFC Mark-2 three band hand-held radiometer

A self-contained, portable, hand-radiometer designed for field usage was constructed and tested. The device, consisting of a hand-held probe containing three sensors and a strap supported electronic module, weighs 4 1/2 kilograms. It is powered by flashlight and transistor radio batteries, utilizes two silicon and one lead sulfide detectors, has three liquid crystal displays, sample and hold radiometric sampling, and its spectral configuration corresponds to LANDSAT-D's thematic mapper bands. The device was designed to support thematic mapper ground-truth data collection efforts and to facilitate 'in situ' ground-based remote sensing studies of natural materials. Prototype instruments were extensively tested under laboratory and field conditions with excellent results.

Tucker, C. J.↗

A parametric study of aliasing error for a narrow field of view scanning radiometer

Starting from the general measurement equation, it is shown that a NFOV scanner can be approximated by a spatially invariant system whose point spread function depends on the detector shape and angular characteristics and electrical filter transfer function for given patches at the top of the atmosphere. The radiometer is modeled by a detector, electrical filter, analog to digital converter followed by a reconstruction filter. The errors introduced by aliasing and blurring into a reconstruction of the input radiant exitance are modeled and analyzed for various detector shapes, sampling intervals, electrical filters and scan types. Quantitative results on the errors introduced are presented showing the various tradeoffs between design parameters. The results indicate that proper selection of detector shape coupled with electrical filter can reduce aliasing errors significantly.

Halyo, N.↗

Infrared heterodyne radiometer for airborne atmospheric transmittance measurements

An infrared heterodyne radiometer (IHR) was used to measure atmospheric transmittance at selected hydrogen fluoride (2.7 micrometer) and deuterium fluoride (3.8 micrometer) laser transitions. The IHR was installed aboard a KC-135 aircraft for an airborne atmospheric measurements program that used the sun as a backlighting source for the transmission measurements. The critical components are: a wideband indium antimonide (1nSb) photomixer, a CW HF/DF laser L0, a radiometric processor, and a 1900 K blackbody reference source. The measured heterodyne receiver sensitivity (NEP) is 1.3 x 10 to the -19th power W/Hz, which yields a calculated IHR temperature resolution accuracy of delta I sub S/-3 sub S = 0.005 for a source temperature of 1000 K and a total transmittance of 0.5. Measured atmospheric transmittance at several wavelengths and aircraft altitudes from 9.14 km (30,000 ft) to 13.72 km (45,000 ft) were obtained during the measurements program and have been compared with values predicted by the AFGL Atmospheric Line Parameter Compilation.

Wolczok, J. M.↗

A 163 micron laser heterodyne radiometer for OH

A 163 micron (1.836 THz) radiometer developed for airplane and/or balloon platforms is described. The laser local oscillator is a CO2 pumped methanol laser operating at a frequency which is approx. 1 GHz from the J = 3/2 - 1/2 transition of OH. The laser is used directly as a local oscillator or is translated in frequency to closer coincidence with the OH emission, depending on achieved detector IF bandwidth. Frequency translation techniques which are described are diode mixing and a method of single sideband generation using an external Stark modulated gas cell. The photoconductive mixer used is a strained Ge crystal, doped with Ga, originally used as an incoherent detector. The uniaxial strain on the Ga doped Ge crystal shifts the threshold for photoconduction from 100/cm to frequencies as low as 50/cm. These detectors are currently being characterized as mixers in the laboratory. Of particular interest are the effect of local oscillator power and strain on IF, bandwidth detector impedance, and conversion loss. Preliminary results of these tests are described and compared with theorectical expectations.

Pickett, H. M.↗

Variations in the Nimbus-7 scanning multichannel microwave radiometer cold reference antenna signals and temperatures during two orbital periods

The observed effects of solar radiance on the Nimbus 7 scanning multichannel microwave radiometer (SMMR) cold reference signal are discussed. Unexpected diurnal responses in this signal sometimes larger than the typical cold reference signal resulted from acquisition of the solar disc. Solar heating of the SMMR components as a function of orbital locations was correlated with the cold reference radiances for two sets of sequential orbit six months apart.

Gloersen, P.↗

Advanced very high resolution radiometer, Mod 2 engineering report

The Advanced High Resolution Radiometer, Mod 2 (AVHRR/2) is a modification of the original AVHRR (AVHRR/1) to expand the number of channels from four to five and provide additional sensing in the infrared region. A comparison of the spectral regions employed in the two instruments is given. Three of the channels are the same on both instruments. The difference in instruments is in the long wave IR region where a single channel was replaced by two channels. The modification from AVHRR/1 to AVHRR/2 was done with a minimum of changes. The areas of change are highlighted and the modifications by module are summarized. It is seen that the primary changes are in the relay optics and in the cooler. In this development program only two models are involved. The first model, the Optical Test Model was constructed and tested to prove the performance and structural integrity of the optical system and the modified cooler. The second model constructed is the Protoflight. Only the areas of the AVHRR/2 which were modified from the AVHRR/1 design are discussed.

Source record↗

On extracting brightness temperature maps from scanning radiometer data

The extraction of brightness temperature maps from scanning radiometer data is described as a typical linear inverse problem. Spatial quantization and parameter estimation is described and is suggested as an advantageous approach to a solution. Since this approach takes into explicit account the multivariate nature of the problem, it permits an accurate determination of the most detailed resolution extractable from the data as well as explicitly defining the possible compromises between accuracy and resolution. To illustrate the usefulness of the method described for algorithm design and accuracy prediction, it was applied to the problem of providing brightness temperature maps during the NOSS flight segment. The most detained possible resolution was determined and a curve which displays the possible compromises between accuracy and resolution was provided.

Argentiero, P.↗

Noise adding radiometer performance analysis

The DSN noise adding radiometer (NAR) measurement accuracy is analyzed. The NAR capability is part of the precision power monitor function recently introduced in the DSN. The potential system noise temperature measurement accuracy is estimated to be about 1.5% with the 1 kelvin noise diode. Performance verification requires comparison noise temperature measurements with the manual Y factor method and routine monitoring of critical elements in the NAR system such as system linearity and noise diode calibration. A technique is presented to calibrate and reduce the effects of the receiving system nonlinearity. Unsatisfactory performance or degradation of these critical NAR elements would require appropriate system upgrading.

Stelzried, C.↗

Infrared radiometer for the Pioneer Venus orbiter. I - Instrument description

A ten-channel IR radiometer for the Pioneer Venus orbiter is described. The experimental techniques used and the design of the instrumentation by which they were implemented are considered. Emphasis is placed on temperature sounding, limb sounding, limb darkening, zenith scanning, cloud top temperature, spectral albedo and water vapor measurements. Instrumentation description is also given including optics, detectors, and electronics. Attention is given to data acquisition and handling, calibration, and in-flight performance.

Taylor, F. W.↗

Pioneer Venus infrared radiometer - Design, implementation and preliminary results

The paper discusses the Pioneer Venus infrared radiometer design and operation. Its main function is to measure the thermal emission from the atmosphere at seven pressure levels above the Venus clouds, allowing a determination of the vertical temperature structure. In addition to the temperature sounding channels, there are two channels operating in the visible and near infrared to study the structure of the upper clouds, and a far infrared channel sensitive to water vapor in and above the clouds. The instrument can operate in four modes including a calibration sequence; by utilizing the spinning action of the spacecraft and short integration times, a substantial portion of the planet can be mapped within a 90 min data taking period centered about periapsis time. Temperature profiles retrieved during the course of the mission will clarify the dynamical processes in the upper atmosphere.

Martonchik, J. V.↗

Pioneer-Venus solar flux radiometer

The paper presents the design and performance characteristics of the Solar Flux Radiometer flown on the Large Probe of the Pioneer-Venus Multiprobe spacecraft. Radiance measurements of the Venusian atmosphere in spectral channels between 400 and 1800 nm as a function of altitude were made, along with elevation and azimuthal measurements of the radiation field performed with five optical channels. Filtered Si and Ge photovoltaic detector output currents were processed with logarithmic transimpedance converters prior to being multiplexed and digitized. Atmospheric sampling in elevation and azimuth was done according to a Gaussian integration scheme; the received data were used to determine the deposition of solar energy in the Venus atmosphere along with upward and downward fluxes and radiances with an altitude resolution of several hundred meters between 67 km and the surface.

Palmer, J. M.↗

Pioneer Saturn infrared radiometer - Preliminary results

Preliminary results of the infrared radiometer experiment on Pioneer Saturn are reported. The instrument made use of two broadband channels centered at 20 and 45 microns which scan at a fixed 75-deg angle with respect to the spacecraft spin axis to acquire 10,000 image pairs of Saturn and its rings in the 2.5 h before closest approach, as well as several observations of Titan. The intensities of radiation observed in both bands indicate an effective temperature of 94.4 + or - 3 K for the planet, implying a total emission greater than twice the absorbed sunlight. Infrared data also indicates a molecular abundance of 0.85 for H2 relative to H2 + He, which can be improved by comparing the derived temperature profiles and radio occultation data. Planetary temperatures are found to range from a minimum of 83 to 140 K at the 1 bar level, with differences of 2.5 K between belts and zones up to the 0.06-bar level, while ring temperatures range from 60 to 70 K on the illuminated side and from less than 60 to 67 K in the planet's shadow and average 55 K on the unilluminated side. Preliminary estimates indicate a 45-micron brightness temperature of 80 + or - 10 K for Titan.

Ingersoll, A. P.↗

A hydrological analysis of east Australian floods using Nimbus-5 electrically scanning radiometer data

The chronological development and diminution of six floods in eastern Australia during January, February, and March 1974 were mapped for the first time by the Nimbus Electrically Scanning Microwave Radiometer (ESMR). Day and nighttime ESMR (19.35 GHz) coverage was analyzed for the low gradient, flooded Darling River system in New South Wales. Apparent movement of surface water as indicated by low brightness temperatures (less than 250 K, day and less than 240 K, night) was easily followed around the curved runoff basin along the northern shoreline of the flooded Darling River during this 3-month period. This pattern was in good agreement with flood crest data at selected river height gage stations, even under cloudy conditions.

Allison, L. J.↗

Antenna pattern correction procedures for the Scanning Multichannel Microwave Radiometer /SMMR/

Procedures for correcting antenna temperature measurements and retrieving the true brightness temperatures are developed for the Scanning Multichannel Microwave Radiometer (SMMR) flown on the Seasat-A and Nimbus-G satellites. These procedures are necessary to meet the measurement accuracies required for deriving sea surface temperatures and wind speeds. It is shown that sidelobe contributions and polarization cross-coupling are major effects to be accounted for, in addition to some unique features of the SMMR instrument such as integration times and antenna scan characteristics. Methods are presented for data averaging and data reformatting, these are to be used with geophysical parameter retrieval algorithms.

Njoku, E. G.↗

Pioneer Venus Sounder Probe Solar Flux Radiometer

The Solar Flux Radiometer aboard the Pioneer Venus Sounder Probe operated successfully during its descent through the atmosphere of Venus. The instrument measured atmospheric radiance over the spectral range from 400 to 1800 nm as a function of altitude. Elevation and azimuthal measurements on the radiation field were made with five optical channels. Twelve filtered Si and Ge photovoltaic detectors were maintained near 30 C with a phase-change material. The detector output currents were processed with logarithmic transimpedance converters and digitized with an 11-bit A/D converter. Atmospheric sampling in both elevation and azimuth was done according to a Gaussian integration scheme. The serial output data averaged 20 bits/sec, including housekeeping (sync, spin period, sample timing and mode). The data were used to determine the deposition of solar energy in the atmosphere of Venus between 67 km and the surface along with upward and downward fluxes and radiances with an altitude resolution of several hundred meters. The results allow for more accurate modeling of the radiation balance of the atmosphere than previously possible.

Tomasko, M. G.↗

The infrared radiometer on the sounder probe of the Pioneer Venus mission

The functional aspects of the Large Probe Infrared Radiometer Instrument are presented taking into account the experiment's objective to measure the net thermal flux as the Venus Probe descended into the planet's atmosphere, as well as to detect water vapor, cloud layers and their infrared opacity. The optical elements, including the detectors are described and a brief review of the instrument's calibration is given.

Boese, R. W.↗

Remote infrared heterodyne radiometer measurements of atmospheric ammonia profiles

An infrared heterodyne radiometer has been used to study the seasonal variation of the vertical distribution of atmospheric ammonia. The ammonia profiles are inferred from high-resolution atmospheric solar transmittance measurements around the ammonia absorption feature at 927.32323 kaysers. The transmittance data are obtained from six IF channels with spectral resolutions ranging from .0067 to .033 kaysers. Results from this study show a marked decrease in the tropospheric ammonia level with a decrease at ground level from approximately 10 ppb in March 1979 to 1.3 ppb in August 1979.

Hoell, J. M.↗

Performance of fused silica as a filter in a wide field-of-view earth radiation budget radiometer

The thermal response of the fused silica dome filter in an earth radiation budget WFOV shortwave channel conceptual design and the impact of that response on the channel measurement, is described. Attention is given to results from design definition and performance analysis studies. Consideration is given to problems associated with achieving the desired levels of confidence in a high accuracy filtered earth radiation budget WFOV radiometer. Finally, design approaches, ground calibration, and data reduction techniques that minimize measurement uncertainties are covered.

Cooper, J. E.↗