Detection of Anomalies in Gamma Background Radiation Data with K-Means and Self-Organizing Map Clustering Algorithms (Consortium on Nuclear Security Technologies (CONNECT) Q1 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. The challenge is that spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optical transmittance of fused silica during irradiation processes.

The level of irradiation-induced optical absorption and the resulting heat deposition in the transparent fused-silica wall of a nuclear light bulb engine during normal operation are investigated by means of a series of related experiments using available radiation sources, each of which simulates some aspect of the radiation flux or dose of the engine. A comparison of the results obtained in electron and reactor experiments indicates that the generation of optical absorption is due to ionizing effects and that neutron-caused displacement effects do not contribute significantly to optical absorption. The implications of these and other results obtained are discussed.

Palma, G. E.↗

Radiocatalyst for Radiation Protection and Microbial Control

Radiocatalysts are materials that reduce the activation energy required to split water into hydrogen and reactive oxygen species (ROS). They are activated by radiation and can be used to improve the ability of water to act as a radiation barrier. This paper reports the results of an experimental evaluation of a gold radiocatalyst. This work provides a preliminary evaluation of the ability of these types of catalysts to increase the efficiency of water hydrolysis when exposed to different types of radiation (GCR). Although the radiation exposure devices used in this testing were not capable of generating radiation as diverse as is commonly found in space, the testing is useful in evaluating the function of these radiocatalytic nanoparticles when exposed to a a subset of the types of radiation that are found in GCR. The results are relevant to evaluating the use of this material for both space radiation protection and the production of useful byproducts, such as ROS, which can be used to maintain the sterility of stored water supplies. Radiocatalysts are materials typically used in radiation cancer therapy to improve the kill rate of tumors. These nanoparticles can be directly injected into tumors or functionalized to enter tumor cells via the blood stream. When they are exposed to radiation, they produce ROS. ROS are water hydrolysis products such as OH¯, O¯, O3, H2O2. This study used radiocatalytic 1.8 nm gold nanoparticles functionalized with citrate. These nanoparticles were tested through exposure to Xrays, 56Fe particles and gamma rays to demonstrate activity to a variety of radiation sources. The results demonstrate that radiocatalysts can improve the radiation absorption of water by a factor of 3 to 8 and can effectively kill bacteria at radiation levels above 1 Gy.

radiocatalyst radiation protection biocide↗

System and method of modulating electrical signals using photoconductive wide bandgap semiconductors as variable resistors

A system and method for producing modulated electrical signals. The system uses a variable resistor having a photoconductive wide bandgap semiconductor material construction whose conduction response to changes in amplitude of incident radiation is substantially linear throughout a non-saturation region to enable operation in non-avalanche mode. The system also includes a modulated radiation source, such as a modulated laser, for producing amplitude-modulated radiation with which to direct upon the variable resistor and modulate its conduction response. A voltage source and an output port, are both operably connected to the variable resistor so that an electrical signal may be produced at the output port by way of the variable resistor, either generated by activation of the variable resistor or propagating through the variable resistor. In this manner, the electrical signal is modulated by the variable resistor so as to have a waveform substantially similar to the amplitude-modulated radiation.

36 MATERIALS SCIENCE↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compatibility of ethylene vinyl acetate (EVA)/ethylene vinyl alcohol (EVOH)/EVA films with gamma, electron-beam, and X-ray irradiation

Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic radiation from filamentary sources in the presence of axially magnetized cylindrical plasma scatterers

Electromagnetic radiation from filamentary electric-dipole and magnetic-current sources of infinite length in the presence of gyrotropic cylindrical scatterers in the surrounding free space is studied. The scatterers are assumed to be infinitely long, axially magnetized circular plasma columns parallel to the axis of the filamentary source. The field and the radiation pattern of each source are calculated in the case where the source frequency is equal to one of the surface plasmon resonance frequencies of the cylindrical scatterers. It is shown that the presence of even a single resonant magnetized plasma scatterer of small electrical radius or a few such scatterers significantly affects the total fields of the filamentary sources, so that their radiation patterns become essentially different from those in the absence of scatterers or the presence of isotropic scatterers of the same shape and size. It is concluded that the radiation characteristics of the considered sources can efficiently be controlled using their resonance interaction with the neighboring gyrotropic scatterers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold Light from Hot Atoms and Molecules

The introduction of rare earth atoms and molecules into lighting discharges led to great advances in efficacy of these lamps. Atoms such as Dy, Ho and Ce provide excellent radiation sources for lighting applications, with rich visible spectra, such that a suitable combination of these elements can provide high quality white light. Rare earth molecules have also proved important in enhancing the radiation spectrum from phosphors in fluorescent lamps. This paper reviews some of the current aspects of lighting research, particularly rare earth chemistry and radiation, and the associated fundamental atomic and molecular data.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calculation of infrared limb emission by ozone in the terrestrial middle atmosphere. I - Source functions. II - Emission calculations

The departure from LTE in the vibration-rotation bands of ozone in the middle atmosphere is analyzed using two statistical equilibrium models: the energy gap model and the simplified single model. The diurnal variations in the fundamental band source functions nu(1) and nu(3) is determined by the diurnal change in the rate of ozone photolysis by the solar radiation. Source functions are presented for the vibration-rotation bands of ozone that emit in the 9-11-micron spectral interval, over an altitude range of 1-110 km. Results are also reported of the evaluation of the radiative transfer equation incorporating these source functions and energy level populations. Using the results of the two statistical equilibrium models, calculations are carried out of the spectrally integrated limb radiance for the limb viewing geometry for daytime conditions. Results indicate that the interpretation of the measurements of spectrally integrated limb radiance from ozone will be greatly complicated by the breakdown of LTE in the vibration-rotational bands of ozone.

Mlynczak, Martin G.↗

Modeling Radiation Detection Using a Mixed-Effects Statistical Model for Background Variation

In this paper, we consider radiation source localization in an urban environment as an inverse problem and use Bayesian parameter estimation techniques to infer the source location and intensity. Since parameter estimation generally requires a large number of model evaluations, we employ a simplified photon transport model, as in a 2017 paper by Stefanescu, et al., to reduce computational requirements. However, the model in the 2017 paper does not account for the physical reality that background radiation varies with position within an urban locale. We incorporate statistical mixed-effects modeling into the simplified transport equation from the Stefanescu, et al. paper to reflect individual variation among the background radiation measurements at multiple detector locations. With our new model, we use a Bayesian DRAM-within-Gibbs technique, which incorporates the Delayed Rejection Adaptive Metropolis (DRAM) algorithm, to estimate the mixed-effects parameters. We note that without adequate prior information, we were unable to simultaneously estimate the set of parameters corresponding to the source intensity, source location, and individual background radiation counts. By calibrating the background in the absence of a source, we obtained narrow prior distributions, which permitted us to jointly infer the source intensity and location and the background radiation distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial coherence of the Stokes component of stimulated Raman scattering excited in a long multimode fibre

The mode structure of the Stokes component of stimulated Raman scattering (SRS) in a multimode fibre excited by a pump field with statistics corresponding to a narrowband Gaussian noise model is theoretically analysed. The relation is obtained between the number of spatially coherent radiation modes of the Stokes wave and fibre parameters and SRS excitation conditions. It follows from this relation that the degree of spatial coherence of the Stokes radiation at the fibre output is determined by the number of spatial modes of pump radiation and the averaged gain of the Stokes radiation over the interaction length. It is established that there exists the threshold gain at which the number of spatially coherent radiation modes of the Stokes component increases infinitely and, therefore, its spatial coherence tends to zero. The estimates of the number of spatially coherent radiation modes of the Stokes component showed that already at the Raman scattering excitation threshold their number is so great that the degree of spatial coherence of the Stokes component radiation corresponds to the degree of coherence of a thermal source radiation. The measured dispersion of spatial intensity fluctuations of the Stokes component sepa-rated by using an interference filter (with the transmission bandwidth {approx}1 nm at 620 nm) proved to be approximately three times higher than the dispersion of radiation intensity fluctuations of a luminescent lamp. The large dispersion of spatial intensity fluctuations of the Stokes component is caused most likely by individual intensity spikes in a small-scale (unresolved by a detector with a spatial resolution of {approx}14 {mu}m) speckle pattern produced in the detection plane by monochromatic Stokes radiation. (coherence)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Qualification of quantum cascade lasers for space environments

Laser-based instruments are enabling a new generation of scientific instruments for space environments such as those used in the exploration of Mars. The lasers must be robust and able to withstand the harsh environment of space, including radiation exposure. Quantum cascade lasers (QCLs), which are semiconductor lasers that emit in the infrared spectral region, offer the potential for the development of novel laser-based instruments for space applications. The performance of QCLs after radiation exposure, however, has not been reported. We report on work to quantify the performance of QCLs after exposure to two different radiation sources, 64 MeV protons and Cobalt-60 gamma rays, at radiation levels likely to be encountered during a typical space flight mission. No significant degradation in threshold current or slope efficiency is observed for any of the seven Fabry-Perot QCLs that are tested.

gamma radiation↗

A heuristic approach to rapid, automatic identification of uranium in high-resolution gamma-ray spectra

Our rule-based expert system, HPGe ID, is used to rapidly and automatically identify well over 200 radioactive sources in less than one second from their gamma-ray signatures in high-resolution gamma-ray spectra. One of the most important sources, uranium, is the most complex in terms of natural or processed form, enrichment grade, and even reactor fuel cycle. To determine these attributes, HPGe ID does not require knowledge of the detector efficiency, the source-to-detector distance, or the geometry of the inspected radiation source—including any shielding. Here we discuss the approach taken with HPGe ID to detect and determine these uranium attributes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid, autonomous analysis of He spectra I: Overview of the RadID program, user experience, and structure

RadID is a new gamma-ray spectrum analysis program for rapid screening of HPGe gamma-ray data to reveal the presence of radionuclide signatures. It is an autonomous, rule-based heuristic system that can identify well over 200 radioactive sources with particular interest in uranium and plutonium characteristics. It executes in about one second. RadID does not require knowledge of the detector efficiency, the source-to-detector distance, or the geometry of the inspected radiation source—including any shielding. In this first of a three-document series we sketch the RadID program’s origin, its minimal requirements, the user experience, and the program operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variable magnification variable dispersion glancing incidence imaging x ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carriers each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a multilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x ray sensitive photographic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard↗

Variable magnification glancing incidence x ray telescope

A multispectral glancing incidence x ray telescope is disclosed, which capable of broadband, high resolution imaging of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more ellipsoidal mirrors are positioned behind the primary focus at an inclination to the optical axis, each mirror having a concave surface coated with a multilayer synthetic microstructure coating to reflect a desired wavelength. The ellipsoidal mirrors are segments of respective ellipsoids having a common first focus coincident with the primary focus. A detector such as an x ray sensitive photographic film is positioned at the second focus of each of the ellipsoids so that each of the ellipsoidal mirrors may reflect the image at the first focus to the detector. In one embodiment the mirrors are inclined at different angles and has its respective second focus at a different location, separate detectors being located at the respective second focus. The mirrors are arranged so that the magnification and field of view differ, and a solenoid activated arm may withdraw at least one mirror from the beam to select the mirror upon which the beam is to impinge so that selected magnifications and fields of view may be detected.

Hoover, Richard↗

Radiation in controlled environments: influence of lamp type and filter material

Radiation in controlled environments was characterized using fluorescent and various high-intensity-discharge (HID) lamps, including metal halide, low-pressure sodium, and high-pressure sodium as the radiation source. The effects of water, glass, or Plexiglas filters on radiation were determined. Photosynthetic photon flux (PPF, 400 to 700 nm), spectra (400 to 1000 nm), shortwave radiation (285-2800 nm), and total radiation (300 to 100,000 nm) were measured, and photosynthetically active radiation (PAR, 400 to 700 nm) and longwave radiation (2800 to 100,000 nm) were calculated. Measurement of PPF alone was not an adequate characterization of the radiation environment. Total radiant flux varied among lamp types at equal PPF. HID lamps provided a lower percentage of longwave radiation than fluorescent lamps, but, when HID lamps provided PPF levels greater than that possible with fluorescent lamps, the amount of longwave radiation was high. Water was the most effective longwave radiation filter. Glass and Plexiglas similarly filtered longwave more than shortwave radiation, but transmission of nonphotosynthetic shortwave radiation was less with Plexiglas than glass. The filter materials tested would not be expected to influence photomorphogenesis because radiation in the action spectrum of phytochrome was not altered, but this may not be the only pigment involved.

NASA Discipline Life Support Systems↗