Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Q-Sync Motors in Commercial Refrigeration: Preliminary Test Results and Projected Benefits

This report provides background information on various fractional-horsepower electric motor technologies, summarizes initial data from a DOE-sponsored Q-Sync motor demonstration project, and extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of 9–12 W evaporator fan motors to Q-Sync motors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Variable Refrigerant Flow Systems Performance on Oak Ridge National Laboratory s Flexible Research Platform: Part 2 Heating Season Analysis

The performance of two HVAC systems was evaluated using ORNL’s FRP, which is a two-story, 3,200 ft2 (297.3 m2) multi-zone unoccupied building that represents a typical low-rise, small office building common in the US existing building stock. The FRP is equipped with a conventional 12.5 ton (44 kW) RTU-VAV reheat system as the baseline system. For this study, a 12 ton (42 kW) VRF with a dedicated outdoor air system (DOAS) was installed to be compared with the baseline RTU system.

47 OTHER INSTRUMENTATION↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications - Design and Simulation Practice to Identify Charge Reduction Opportunities for Residential AC/HP Units

Based on three 5-ton, single-speed heat pumps (HPs), using R-410A, which use the same compressor, indoor blower and outdoor fan, the DOE/ORNL Heat Pump Design Model was used to conduct comparative modelling study. Regarding charge reduction opportunities, in general, we recommend: 1. Downsizing the outdoor condenser will reduce the required system charge, i.e. using smaller tube diameters or fewer tubes; reducing the evaporator inner volume is less important; to offset the reduced condenser tube side surface area, one can increase the air side surface area (fin density) or condenser air flow rate via using a more efficient fan. 2. microchannel heat exchangers are most effective in reducing the required charge, by up to 60% in the condenser and evaporator. To develop low charge systems, one should at least use a microchannel heat exchanger as the outdoor condenser. 3. TXV systems are less sensitive to charge reduction. For the drop-in application, one can decrease the charge to minimize the liquid section in the condenser, at the expense of minor performance degradation; for example, when reducing the system charge by 15% (decrease the subcooling degree to 2R), the simulation results prove that the decrease is less than 3% in the EER and less than 6% in the capacity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECC Refrigerator: Characterize Performance of a Prototype Electrochemical Compressor

This report documents experimental study to characterize performance of a prototype electrochemical compressor, provided by Xergy INC. It describes the working mechanism and its electrochemical efficiency and isentropic compression efficiency. The experimental results demonstrate that the prototype compressor is able to pump hydrogen flow from 25 psia to 140 psia, and deliver the flow rate as predicted. On the other hand, its efficiency level is low, having the electrochemical efficiency less than 40%, and isentropic efficiency below 47%. Using two identical ECC compressors in parallel will reduce the current density and ohm loss, which can increase the isentropic efficiency up to 67% with increased cost. Further improvements on the compressor are suggested, e.g. using more conductive membrane, etc.

42 ENGINEERING↗

Extending ORNL HPDM Capabilities for Design and Optimization of New Refrigerant Blends – FY19 2nd Quarterly Milestone Report: Literature Review of Heat Transfer and Pressure Drop Correlations for HFO Blends in Water Heating Application

Based on a comprehensive literature review, the two-phase heat transfer and pressure drop correlations, best suitable for modelling the next generation HFO blends in brazed plate heat exchangers and fluted tube-in-tube heat exchangers, were identified. The selected correlations have been incorporated to the segment-to-segment (finite volume) heat exchanger models in the HPDM library. Details are described below.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Cost Electrochemical Compressor (ECC) Utilizing Green Refrigerants for HVAC Applications [Slides]

HVAC systems account for approximately 14 Quads or primary energy annually, or nearly 30% of all energy used in the U.S. commercial and residential buildings. Electrochemical compression (ECC) is a transformative solid-state technology and ECC based HVAC systems could result in 40% less energy use. The goal of the project was to develop the most efficient, noiseless, and most environmentally friendly cooling system based on integrating 2 (two) technologies: a) electrochemical compressors (ECC) to replace mechanical compressors for use in building heating, ventilation, and air conditioning (HVAC) applications and b) Ionic Liquid Desiccant Systems. The overall objective was to develop and build a scalable ILD/ECC-based air conditioning system operating with a COP of 4.5, with a price premium of $70 installed per kBTU/hr.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-Refrigerated Warehouse Design Guide [Slides]

Warehouses typically have a low energy use relative to their floor area. This make warehouses ideal to install solar panels and offset on-site energy use and have a surplus of energy if roof area is maximized. This surplus can be used to provide things like grid services or charge electric vehicle fleets. This document is intended to provide owners and operators of warehouse information on designing efficient/decarbonized warehouses and maximize on-site generation. The information here references outside publications to provide specific guidance, such as the ASHRAE Advanced Energy Design Guides, but tailors the information specifically to warehouses. This guide provides owners a better understanding of warehouse design as well as more specific information for themselves or outside designers to reference.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemical Compression for Ammonia Storage and Refrigeration System (Phase 2)

In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm 2 of active area. We demonstrated the operation of larger cells with 100 cm 2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state.

25 ENERGY STORAGE↗

Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability (CRADA NFE-21-08888 Final Report)

Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. Eck Industries successfully casted Al-Ce-Mg heat exchanger. ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.

36 MATERIALS SCIENCE↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications (NFE-19-07879)

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability

• Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. • Eck Industries successfully casted Al-Ce-Mg heat exchanger. • ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. • Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. • ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. • In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.

36 MATERIALS SCIENCE↗