At least 811 records · Page 45

A simple radionuclide-driven single-ion source

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating {sup 148}Gd onto a silicon {alpha}-particle detector and vapor depositing a layer of BaF{sub 2} over it. {sup 144}Sm recoils from the alpha decay of {sup 148}Gd are used to dislodge Ba{sup +} ions from the BaF{sub 2} layer and emit them in the surrounding environment. The simultaneous detection of an {alpha} particle in the substrate detector allows for tagging of the nuclear decay and of the Ba{sup +} emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(U) Using the MCNP6 Perturbation Capability for Source Nuclide Density Sensitivities

The Taylor series (differential operator) perturbation method, as implemented in the PERT capability in MCNP6 (Ref. 1), can be used for first- and second-order sensitivity analyses in fixed-source problems. Unfortunately, the PERT capability does not yet work with point-detector (F5) or pulse-height (F8) tallies. Also, the second-order Taylor series term lacks the cross terms that would allow the calculation of mixed sensitivities. Finally, the PERT capability does not compute any sensitivities involving the source in a fixed-source problem. When neutrons or gamma rays are emitted due to radioactive decay, the source rate density depends intrinsically on the nuclide densities in the source material. When the PERT capability in MCNP6 is used to compute sensitivities of a response to nuclide and material densities, those sensitivities do not include the effect of the source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of background sources associated with the production of radioactive isotopes in the DEVIS experiment (double-beta decay)

Measurements performed in searches for the double-beta decay of {sup 136}Xe showed an excess of events in exposures of a target enriched in the isotope {sup 136}Xe in relation to exposures of a target depleted in this isotope. The activation of xenon in the detector used under the effect of background neutron and muon radiation and the possible contribution of these processes to the results of relevant measurements are studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sealed source peer review plan

Sealed sources are known quantities of radioactive materials that have been encapsulated in quantities that produce known radiation fields. Sealed sources have multiple uses ranging from instrument calibration sources to sources that produce radiation fields for experimental applications. The Off-Site Source Recovery (OSR) Project at Los Alamos National Laboratory (LANL), created in 1999, under the direction of the Waste Management Division of the U.S. Department of Energy (DOE) Albuquerque has been assigned the responsibility to recover and manage excess and unwanted radioactive sealed sources from the public and private sector. LANL intends to ship drums containing qualified sealed sources to the Waste Isolation Pilot Plant (WIPP) for disposal. Prior to shipping, these drums must be characterized with respect to radiological content and other parameters. The U. S. Environmental Protection Agency (EPA) requires that ten radionulcides be quantified and reported for every container of waste to be disposed in the WIPP. The methods traditionally approved by the EPA include non-destructive assay (NDA) in accordance with Appendix A of the Contact-Handled Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (DOE, 2002) (CH WAC). However, because of the nature and pedigree of historical records for sealed sources and the technical infeasibility of performing NDA on these sources, LANL proposes to characterize the content of these waste drums using qualified existing radiological data in lieu of direct measurement. This plan describes the process and documentation requirements for the use of the peer review process to qualify existing data for sealed radiological sources in lieu of perfonning radioassay. The peer review process will be performed in accordance with criteria provided in 40 CFR {section} 194.22 which specifies the use of the NUREG 1297 guidelines. The plan defines the management approach, resources, schedule, and technical requirements for the subject peer review.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing claims of the GW170817 binary neutron star inspiral affecting β-decay rates

On August 17, 2017, the first gravitational wave signal from a binary neutron star inspiral (GW170817) was detected by Advanced LIGO and Advanced VIRGO. Here we present radioactive β-decay rates of three independent sources 44 Ti, 60 Co and 137 Cs, monitored during the same period by a precision experiment designed to investigate the decay of long-lived radioactive sources. We do not find any significant correlations between decay rates in a 5 h time interval following the GW170817 observation. This contradicts a previous claim published in this journal of an observed 2.5σ Pearson Correlation between fluctuations in the number of observed decays from two β-decaying isotopes ( 32 Si and 36 Cl) in the same time interval. By correcting for the choice of an arbitrary time interval, we find no evidence of a correlation above 1.5σ confidence. In addition, we argue that such analyses on correlations in arbitrary time intervals should always correct for the so-called Look-Elsewhere effect by quoting the global significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of source-production revision on the dose-rate constant of {sup 131}Cs interstitial brachytherapy sources

Purpose: Since its introduction in 2004, the model CS-1 Rev.1 {sup 131}Cs source has been used in many radiation therapy clinics for prostate brachytherapy. In 2006, this source model underwent a Rev.2 production revision. The aim of this work was to investigate the dosimetric influences of the Rev.2 production revision using high-resolution photon spectrometry. Methods: Three CS-1 Rev.1 and three CS-1 Rev.2 {sup 131}Cs sources were used in this study. The relative photon energy spectrum emitted by each source in the transverse bisector of the source was measured using a high-resolution germanium detector designed for low-energy photon spectrometry. Based on the measured photon energy spectrum and the radioactivity distribution in the source, the dose-rate constant ({Lambda}) of each source was determined. The effects of the Rev.2 production revision were quantified by comparing the emitted photon energy spectra and the {Lambda} values determined for the sources manufactured before and after the production revision. Results: The relative photon energy spectrum originating from the principal emissions of {sup 131}Cs was found to be nearly identical before and after the Rev.2 revision. However, the portion of the spectrum originating from the production of fluorescent x rays in niobium, a trace element present in the source construction materials, was found to differ significantly between the Rev.1 and Rev.2 sources. The peak intensity of the Nb K{sub {alpha}} and Nb K{sub {beta}} fluorescent x rays from the Rev.2 source was approximately 35% of that from the Rev.1 source. Consequently, the nominal {Lambda} value of the Rev.2 source was found to be greater than that determined for the Rev.1 source by approximately 0.7%{+-}0.5%. Conclusions: A significant reduction (65%) in relative niobium fluorescent x-ray yield was observed in the Rev.2 {sup 131}Cs sources. The impact of this reduction on the dose-rate constant was found to be small, with a relative difference of less than 1%. This study demonstrates that photon spectrometry can be used as a sensitive and convenient tool for monitoring and for quantifying the dosimetric effects of brachytherapy source-production revisions. Because production revision can change both the geometry and the atomic composition of brachytherapy sources, its dosimetric impact should be carefully monitored and evaluated for each production revision.

60 APPLIED LIFE SCIENCES↗

Photon energy spectrum emitted by a novel polymer-encapsulated {sup 103}Pd source and its effect on the dose rate constant

Two independent groups have published intrinsic dosimetry parameters for the recently introduced OptiSeed{sup 103} interstitial brachytherapy source which contains {sup 103}Pd encapsulated by a novel polymer shell. The dose rate constant ({lambda}) reported by the two groups, however, differed by more than 6% and there is currently no AAPM recommended consensus value for this source in clinical dosimetry. The aim of this work was to perform an independent determination of {lambda} for the OptiSeed{sup 103} source using a recently developed photon spectrometry technique. Three OptiSeed{sup 103} sources (model 1032P) with known air-kerma strength were used in this study. The photon energy spectrum emitted along the radial direction on the source's bisector was measured in air using a high-resolution intrinsic germanium spectrometer designed and established for low-energy brachytherapy source spectrometry. The dose rate constant of each source was determined from its emitted energy spectrum and the spatial distribution of radioactivity in the source. Unlike other sources made with traditional titanium encapsulation, the photons emitted by the OptiSeed{sup 103} sources exhibited only slight spectral hardening, yielding a relative energy spectrum closer to that emitted by bare {sup 103}Pd. The dose rate constant determined by the photon spectrometry technique for water was 0.664{+-}0.025 cGy h{sup -1} U{sup -1}. This value agreed, within experimental uncertainties, with the Monte Carlo-calculated value ({sub MC}{lambda}) of 0.665{+-}0.014 cGy h{sup -1} U{sup -1} and the TLD-measured value (with a Monte Carlo-calculated solid-phantom-to-water conversion factor) of 0.675{+-}0.051 cGy h{sup -1} U{sup -1} reported by Wang and Hertel [Appl. Radiat. Isot. 63, 311-321 (2005)]. However, it differed by -6.7% from the {sub MC}{lambda} of 0.712{+-}0.043 cGy h{sup -1} U{sup -1} reported by Bernard and Vynckier [Phys. Med. Biol. 50, 1493-1504 (2005)]. The results obtained in this work provide additional information needed for establishing a consensus value for the dose rate constant for the OptiSeed{sup 103} source. It suggests that an eventual consensus value of {lambda} for the OptiSeed{sup 103} source is likely to be closer to a value of 0.668 cGy h{sup -1} U{sup -1} rather than 0.693 cGy h{sup -1}U{sup -1} as initially recommended by the source manufacturer based on the two previously published results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incorporation of 40 CFR 192 as an ARAR when Implementing MARSSIM (USACE Input to the MARSSIM Committee for MARSSIM Revision 2) - 18526

One example special case for Final Status Surveys (FSSs) occurs at Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA) sites at which the radioactive materials are from the processing of uranium or thorium ores for their source material content. At these sites, EPA's Health and Environmental Protection Standards for Uranium and Thorium Mill Tailings, in 40 CFR 192, are applicable. Also, 40 CFR 192 may be invoked at non-UMTRCA sites through the CERCLA as an Applicable or Relevant and Appropriate Requirement (ARAR) due to the presence of radium (Ra)-226 or Ra-228, even though the source of residual radioactive material was not a uranium or thorium mill tailings facility. However, the regulatory requirements in these standards infringe on some of the recommendations in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). Specifically, the soil cleanup standards for Ra-226 or Ra-228 are specified as averages over an area of 100 square meters (m{sup 2}). Note that in the 40 CFR 192 rulemaking, an averaging area of 100 m{sup 2} was used as a reasonable footprint for a home. One goal of the 40 CFR 192 standards was to protect future homes from indoor radon, and the specified averaging area was a component implemented for the protection of health. In addition, 40 CFR 192 is silent regarding elevated measurement criteria (EMC)-type requirements for smaller areas of elevated radioactive material within the 100-m{sup 2} footprint. At UMTRCA sites and CERCLA sites where UMTRCA is an ARAR, the following approach for FSSs is acceptable: - Survey units (SUs) may be classified, as appropriate, and survey activities may be adjusted accordingly for Class 1, Class 2, or Class 3 SUs. - Class 1 soil SUs should provide for evaluation of portions that are no greater than 100 m{sup 2} in size, consistent with the 40 CFR 192 standards. - Class 2 and 3 soil SUs are not expected to exceed the 40 CFR 192 soil cleanup standard, so they do not require evaluation of portions that are no greater than 100 m{sup 2} in size. - Compliance with 40 CFR 192 can be demonstrated through analysis of soil samples or composite soil samples from each SU, in conjunction with gamma radiation scanning or in situ gamma radiation measurements of each SU. When appropriate, these gamma radiation scans or in situ measurements correlated to soil sampling may be used in place of soil sampling. - By demonstrating that the average over 100 m{sup 2} meets the 40 CFR 192 soil cleanup standard, the EMC criteria for small elevated areas of activity are not required for the purposes of MARSSIM, but may be developed. These minor modifications to the standard MARSSIM radiological survey approach are acceptable for UMTRCA sites or CERCLA sites where UMTRCA is an ARAR. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An interchangeable-cathode vacuum arc plasma source

A simplified vacuum arc design [based on metal vapor vacuum arc (MeVVA) concepts] is employed as a plasma source for a study of a {sup 7}Be non-neutral plasma. The design includes a mechanism for interchanging the cathode source. Testing of the plasma source showed that it is capable of producing on the order of 10{sup 12} charges at confinable energies using a boron-carbide disk as the cathode target. The design is simplified from typical designs for lower energy and lower density applications by using only the trigger spark rather than the full vacuum arc in high current ion beam designs. The interchangeability of the cathode design gives the source the ability to replace only the source sample, simplifying use of radioactive materials in the plasma source. The sample can also be replaced with a completely different conductive material. The design can be easily modified for use in other plasma confinement or full MeVVA applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gross Alpha Beta Radioactivity in Air Filters Measured by Ultra Low Level alpha/beta Counter

Study of radioactivity in air as very important for life is done regularly using different methods in every country. As a result of nuclear reactors, atomic centrals, institutions and laboratories, which use the radioactivity substances in open or closed sources, there are a lot radioactive wastes. Mixing of these wastes after treatment with rivers and lakes waters makes very important control of radioactivity. At the other side nuclear and radiological accidents are another source of the contamination of air and water. Due to their radio toxicity, especially those of Sr{sup 90}, Pu{sup 239}, etc. a contamination hazard for human begins exist even at low concentration levels. Measurements of radioactivity in air have been performed in many parts of the world mostly for assessment of the doses and risk resulting from consuming air. In this study we present the results of international comparison organized by IAEA Vienna, Austria for the air filters spiked with unknown Alpha and Beta Activity. For the calibration of system we used the same filters spiked: a) with Pu-239 as alpha source; b) Sr-90 as beta source and also the blank filter. The measurements of air filter samples after calibration of the system are done with Ultra Low Level alpha/beta Counter (MPC 9604) Protean Instrument Corporation. The high sensitivity of the system for the determination of the Gross Alpha and Beta activity makes sure detection of low values activity of air filters. Our laboratory results are: Aalpha = (0.19+-0.01) Bq/filter and Aalpha(IAEA) = (0.17+-0.009) Bq/filter; A{sub b}eta = (0.33+-0.009) Bq/filter and A{sub b}eta (IAEA) = (0.29+-0.01) Bq/filter. As it seems our results are in good agreement with reference values given by IAEA (International Atomic Energy Agency).

54 ENVIRONMENTAL SCIENCES↗

Benchmarking the New RESRAD-OFFSITE Source Term Model with DUST-MS and GoldSim - 13377

RESRAD-OFFSITE is a computer code developed by Argonne National Laboratory under the sponsorship of U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC). It is designed on the basis of RESRAD (onsite) code, a computer code designated by DOE and NRC for evaluating soil-contaminated sites for compliance with human health protection requirements pertaining to license termination or environmental remediation. RESRAD-OFFSITE has enhanced capabilities of modeling radionuclide transport to offsite locations and calculating potential radiation exposure to offsite receptors. Recently, a new source term model was incorporated into RESRAD-OFFSITE to enhance its capability further. This new source term model allows simulation of radionuclide releases from different waste forms, in addition to the soil sources originally considered in RESRAD (onsite) and RESRAD-OFFSITE codes. With this new source term model, a variety of applications can be achieved by using RESRAD-OFFSITE, including but not limited to, assessing the performance of radioactive waste disposal facilities. This paper presents the comparison of radionuclide release rates calculated by the new source term model of RESRAD-OFFSITE versus those calculated by DUST-MS and GoldSim, respectively. The focus of comparison is on the release rates of radionuclides from the bottom of the contaminated zone that was assumed to contain radioactive source materials buried in soil. The transport of released contaminants outside of the primary contaminated zone is beyond the scope of this paper. Overall, the agreement between the RESRAD-OFFSITE results and the DUST-MS and GoldSim results is fairly good, with all three codes predicting identical or similar radionuclide release profiles over time. Numerical dispersion in the DUST-MS and GoldSim results was identified as potentially contributing to the disagreement in the release rates. In general, greater discrepancy in the release rates was found for short-lived, fast-moving radionuclides than for long-lived, slow-moving radionuclides. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of radioactive ion beam production systems for Tokai Radioactive Ion Acceleration Complex--High temperature ion source for short-lived isotopes

We have developed a new ion source system in the isotope separator on-line at Japan Atomic Energy Agency, for separation of short-lived isotopes produced by proton-induced fission of {sup 238}U. The ion source system is a forced electron beam induced arc discharge version E type ion source with a target container. We successfully operated this system at 2000 deg. C as a result of reductions in volume of the ion source and the target container, introduction of heating method by electron bombardment, and improvement to the heat shield. This new ion source system was tested using {sup 238}U of 640 mg/cm{sup 2} with a proton primary beam of 30 MeV, 350 nA. Release times were measured for Kr, In, and Xe. The values of release times are 2.6 s for Kr, 1.8 s for In, and 4.6 s for Xe. In this work, the ion source system enabled us to mass-separate short-lived isotopes such as {sup 93}Kr(T{sub 1/2}=1.286 s), {sup 129}In(T{sub 1/2}=0.61 s), and {sup 141}Xe(T{sub 1/2}=1.73 s) with intensity of 10{sup 3} ions/s.

43 PARTICLE ACCELERATORS↗

Methods to Track Effective Doses from Airborne Radioactive Emissions for Compliance with 40 CFR 61, SUBPART H

US Department of Energy national laboratories can play an integral role in not only the advancement of science but also in the treatment of various medical conditions through research and development activities conducted at radioisotope production facilities. Here, a project has been underway at Oak Ridge National Laboratory since 2016 whose mission is to produce and supply the radioisotope 227 Ac, which is used in a radiopharmaceutical developed to treat certain types of prostate cancer and bone metastases. Production activities result in the environmental release of airborne radioactive emissions, which are governed by Clean Air Act regulations described in 40 CFR Part 61, Subpart H. Stack 3039, the source that emits radioactive effluents from 227 Ac production, is subject to additional requirements outlined in American National Standards Institute (ANSI) N13.1-1969 due to its grandfathered status. Radioactive emissions are limited to levels below those that would cause annual compliance dose standards for members of the public to be exceeded and stack 3039 to lose its grandfathered status. To allow for maximum production of 227 Ac without exceeding relevant dose limits, monthly tracking of project emissions and resulting CAP88-PC modeled effective doses to a maximally exposed individual have been implemented. Four years of tracking data were compiled and analyzed to identify additional methods that could be used to estimate project doses more frequently, potentially further optimizing 227 Ac production while maintaining compliance with applicable regulations.

atmospheric emissions↗

Neutron Sources and Facilities

This chapter provides a brief survey of the types of neutron sources that are available for imaging applications, primarily focusing on high-flux sources such as reactors or spallation sources but also including smaller or portable sources based on radioactive decay or small accelerators. Although nearly all neutron imaging studies performed so far have used portable or reactor-based sources, spallation sources will be of increasing importance in the future. Their designs are less familiar and somewhat more complex, so the chapter concentrates on them.

43 PARTICLE ACCELERATORS↗

Mitigation of Cosmic Rays-Induced Errors in Superconducting Quantum Processors

Environmental radioactivity and cosmic-rays have recently been identified as a source of decoherence in super-conducting quantum bits (qubits). In particular, the absorption of cosmic-ray muons and gamma rays emitted by naturally occurring radioactive isotopes in the qubit substrate leads to correlated errors in superconducting quantum processors, posing significant challenges to quantum error correction. To enable quantum computing to scale, it is therefore necessary the devel-opment of mitigation strategies to prevent, or keep under control, error bursts due to particle impacts in the chip. While most environmental radioactive sources can be effectively suppressed using dedicated shielding, cosmic-ray muons, with their high penetration capability, can only be mitigated by moving the entire facility in a deep underground laboratory. This work explores the potential for developing a novel class of quantum processors equipped with an active veto system to protect superconducting-based quantum computers from the detrimental effects of atmospheric muons. Such a device would enable the identification of an atmospheric muon interaction within the processor and veto all operations performed during the occurrence of such an interaction. By demonstrating high detection efficiency and negligible dead time, we aim to establish that the future of quantum processors can be envisioned in above-around facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗