Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

In‐Silico Device Performance Prediction of Cosensitizer Dye Pairs for Dye‐Sensitized Solar Cells

Abstract Endeavors in the field of dye‐sensitized solar cells (DSCs) have shown great promise when adopting a data‐driven approach to materials discovery, such as successful molecular‐scale predictions of light‐harvesting chromophores. However, predictions of DSC dyes would become much more sophisticated if a molecular‐to‐macroscopic DSC device prediction methodology existed. Thereby, a fully computational pipeline is presented that predicts device‐performance parameters of DSCs which contain varying dye combinations. Optimal pairing of complementary dyes is identified via a data‐driven workflow that affords cosensitized DSCs with maximum power‐conversion efficiencies. Six high‐performing DSC dyes are paired with partner dyes that are screened from a database of 8488 compounds using sequential heuristic filters. Existing models that predict short‐circuit‐current density ( J SC ) and open‐circuit voltage ( V OC ) parameters are adapted to predict singly sensitized and cosensitized DSC performance. The predictions for J sc values of singly sensitized devices match experimental literature values with comparable accuracy to more computationally costly methods. Five out of six dye pairings are predicted to have greater J SC values when cosensitized compared to their corresponding singly sensitized devices, including two pairs that show strong J sc boosts of +13% and +12% when cosensitized. Thus, the prospect of an entirely in‐silico prediction pipeline for DSC performance that can be used to realize the fully automated design of optimized cosensitized DSCs is demonstrated.

14 SOLAR ENERGY↗

Carbon nanotube thermoelectric devices by direct printing: Toward wearable energy converters

Thermoelectric devices convert thermal energy to electrical energy and are particularly well-suited for energy harvesting from waste heat. Even as the number of electronic devices used in daily life proliferates, technical advances diminish the average power such devices require to perform a given function. Here, localized thermal gradients that abound in our living environments, despite having modest energy densities, are therefore becoming increasingly viable and attractive to power such devices. With this motivation, we report the design, fabrication, and characterization of single-wall carbon nanotube thermoelectric devices (CNT-TDs) on flexible polyimide substrates as a basis for wearable energy converters. Our aqueous-solution-based film fabrication process could enable readily scalable, low-cost TDs; here, we demonstrate CNT-hydroxypropyl cellulose (HPC) composite thermoelectric films by aerosol jet printing. The electrical conductivity of the composite films is controlled through the number of CNT/HPC layers printed in combination with control of the annealing conditions.

30 DIRECT ENERGY CONVERSION↗

Characterizing and improving the performance of molten-salt-steam heat exchangers in concentrating solar power plants

Shell-and-tube heat exchangers (HXs) for steam generation from molten salts in concentrating solar power (CSP) plants experience thermal fatigue due to significant temperature gradients and inherent transient operation. Molten salt-steam HX design lifespans exceed actual lifespans, and, as a consequence, designers overpredict plant profitability and operators neglect appropriate prescriptions to optimize these lifetimes. Here, this study refines HX lifespan estimates with data benchmarked against thermal-fluid mechanical modeling of stress and accumulated fatigue. Reduced-order thermal models of the molten salt-steam, shell-and-tube evaporator and superheater predict transient temperature profiles along the two HXs salt-steam flow paths. The modeled evaporator and superheater temperature profiles enable assessment of cyclic stresses within the HX tubesheets, where molten-salt HX failures are most common. Evaporator and superheater performance data from a current 110 MW elec commercial CSP plant provide a basis for validating the reduced-order HX models. HX life predictions derived from stochastic failure distributions serve as inputs for simulating and optimizing existing plant operations. The impact of the updated lifespans on overall plant revenue depends on operating scenarios. This study suggests that typical ramping rates for a CSP plant with a high-temperature Rankine cycle result in an evaporator and superheater life of approximately 10 and 25 years, respectively, compared to the design target of 30 years. Reduced HX lifespans decrease operational plant revenue on average by 4.6-5.1%. Furthermore, there may be as many as four HX replacements over the 30-year lifetime of the plant; and, purchase agreement loss due to failure to meet contractual production requirements can have ramifications that include the risk of bankruptcy.

14 SOLAR ENERGY↗

CALORIE: A Constraint Language and Optimizing Runtime for Exascale Power Management (Final Report)

This final technical report summarizes the key accomplishments on the CALORIE project, a DOE Early Career award received by PI Henry Hoffmann at the University of Chicago. CALORIE’s main goal was to create principled methodologies, tools, and practices to help scientists and high-performance computing (HPC) operators maximize the performance and insights obtained from scientific computing applications in the face of exascale power constraints. The project accomplished these goals by completing the following objectives: • Designing a language for describing application goals (including constraints and objectives) and system capabilities. The application goals will include things like which simulations or simulations plus in situ analysis will be run together, what the power constraints are, and what requirements there are for in situ analysis (for example, a desired frame rate for visualization). The system capabilities include all components that can be adjusted to tradeoff power and performance. • Designing a runtime system that takes specified goals and capabilities and dynamically determines what capabilities to use to meet the goals. This runtime adapts to changes in goals, application behavior, or available capabilities to automatically maintain the goals despite unexpected disturbances. • Developing a foundational understanding of how power constraints affect the problem of scheduling applications in large-scale systems. This report provides an overview of the accomplishments related to each of these key objectives.

97 MATHEMATICS AND COMPUTING↗

Historical Power Outages of the United States and the Social Vulnerability Index

Several works have been documented in the literature to study the societal effect of power outages and to analyze their correlation with the Social Vulnerability Index (SVI). Because the SVI is calculated based on the summed rank of multiple vulnerability factors for environmental hazards, it can include factors irrelevant to power outages caused by extreme events. This work performs a detailed correlation analysis for social vulnerability and power outages by considering different SVI themes (e.g., socioeconomic status, household composition, racial and ethnic minority status, and housing and transportation) and power outages with and without a threshold for extreme weather events. Although there is some relation between specific themes and aspects of power outages and the SVI in the results, there is no strong distinction between power outage durations and low vs. high SVI values. These results point to the need for further research that grounds the specific factors and methods used to develop SVI and related indices to energy services and power systems disruptions.

Bhusal, Narayan↗

Hybrid Imitation Learning for Real-Time Service Restoration in Resilient Distribution Systems

Self-healing capability is a critical factor for a resilient distribution system, which requires intelligent agents to automatically perform service restoration online, including network reconfiguration and reactive power dispatch. Here, the article proposes the imitation learning framework for training such an agent, where the agent will interact with an expert built based on the mixed-integer program to learn its optimal policy, and therefore significantly improve the training efficiency compared with exploration-dominant reinforcement learning (RL) methods. This significantly improved training efficiency makes the training problem under N-k scenarios tractable. A hybrid policy network is proposed to handle tie-line operations and reactive power dispatch simultaneously to further improve the restoration performance. The 33-bus and 119-bus systems with N-k disturbances are employed to conduct the training. The results indicate that the proposed method outperforms traditional RL algorithms such as the deep-Q network.

42 ENGINEERING↗

Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D

The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the T e ≈ 7 − 10 eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.

Cherab↗

Drop C: The Drop-In, Ring-of-Power Heliostat (Final Report)

This report summarizes the work performed within the Drop-C: The Drop-In, Ring-of-Power Heliostat project. The Drop-C project aimed to develop a novel heliostat with an installed cost of $\$50$/m 2 ($\$2015$) which is a drastic cost reduction compared to the state-of-the-art. The resulting 27m 2 SunRing TM heliostat’s relative small size necessitates the parallel development of a wireless solar field network and a rapid calibration system. The SunRing heliostat is an evolution of the Ring-of-Power (ROP) design from Abengoa Solar LLC which had a reported installed cost of $114/m 2 . Cost savings relative to the ROP were sought by increasing the mirror area, improving the structural efficiency, a more accurate assessment of wind loads, and an improved assembly and installation procedure. The project spanned three Budget Periods (BP) where a digital heliostat was developed in BP1 using wind tunnel testing to define load conditions.

14 SOLAR ENERGY↗

BuildingQA: A Benchmark for Natural Language Question Answering over Building Knowledge Graphs

Graph-based representations of building metadata using ontologies like Brick are vital for smart building applications, but querying them remains a challenge for practitioners. Knowledge Graph Question Answering (KGQA) systems, meant to retrieve answers from natural language questions, traditionally require large-scale training data, making them ill-suited for the specialized and data-scarce building domain. The advent of Large Language Models (LLMs) offers a paradigm shift, enabling zero-shot natural language querying without building/domain-specific training. Yet, there is no standardized benchmark for building-specific KGQA which can guide and validate research in this area. To address this gap, our work makes three primary contributions. First, we introduce the BuildingQA Benchmark Dataset, constructed through a multi-stage process of collecting practitioner data, augmenting it with LLMs for linguistic diversity, and curating a final set of 188 questions across 4 buildings. Second, we characterize the benchmark's complexity and ambiguity, introducing a novel method to quantify its "lexical gap" and providing a four-stage diagnostic framework for analyzing how systems fail. Third, we benchmark zero-shot LLM-powered KGQA systems to establish baseline performance and analyze their failure modes. Our evaluation reveals that top-performing systems achieve a maximum F1 score of only 0.38. This result does not indicate a failure of these powerful systems, but rather underscores the unique challenges posed by our benchmark. It demonstrates a critical performance gap, showing that current methods successful on general KGs struggle with the specific lexical and structural nuances of the building domain. BuildingQA1 thus provides the benchmark dataset and foundational analysis needed to drive the development of novel, domain-aware methods required to unlock the use of semantic data in buildings.

Mulayim, Ozan Baris↗

A mass spectrometry-based high-throughput screening method for engineering fatty acid synthases with improved production of medium-chain fatty acids

Microbial cell factories have been extensively engineered to produce free fatty acids (FFAs), key components of crucial nutrients, soaps, industrial chemicals, and fuels. Yet, our ability to control the specificity of microbially synthesized FFAs is still limited for medium-chain fatty acids (MCFAs), which is mainly due to lack of high-throughput approaches for FFA analysis. Here we report a mass spectrometry (MS)-based method for rapid profiling of MCFAs in Saccharomyces cerevisiae by using membrane lipids as a proxy. Specially, matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF) MS was used to detect shorter acyl chain phosphatidylcholines from membrane lipids and the m/z peak ratio at 730 and 758 was used as an index for improved MCFA production. This yeast colony-based method can be performed at a rate of ~2 second per sample, which is much faster than the gold standard gas chromatography (GC)-MS (typically > 30 min per sample). To demonstrate the power of this method, we performed site-saturation mutagenesis of the yeast fatty acid synthase and identified 9 mutants that resulted in improved MCFA production relative to the wild-type strain. This colony-based MALDI-ToF MS screening method offers an alternative way for engineering microbial fatty acid compositions in a high-throughput manner.

59 BASIC BIOLOGICAL SCIENCES↗

Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity

This report presents an independent assessment of the cost and performance of select fossil energy power systems—pulverized coal (PC) and natural gas combined cycle (NGCC) plants—using a systematic, transparent, technical, and economic approach. This is Volume 1 of the baseline series: Bituminous Coal and Natural Gas to Electricity. The cost and performance of fossil fuel‐based generation technologies represented in this report are important inputs to assessments and determinations of technology combinations to be utilized to meet the projected demands of future power markets. From a research and development perspective, this report is used to assess goals and metrics and to provide a consistent basis for comparing developing technologies. The main report consists of fifteen power plant configurations, six PC cases (with and without carbon capture) nine NGCC cases (with and without carbon capture) and few additional cases of higher capture rate, for both PC and NGCC plants in the appendix. In addition to the report, an interactive tool was developed that allows users to manipulate six key study parameters simultaneously for each case and visualize the impact on three metrics: 1) levelized cost of electricity (LCOE), 2) cost of CO 2 capture (CCC), and 3) cost of CO 2 avoided (CCA). Following is the link to the interactive tool: https://netl.doe.gov/NETLVol1BaselineTool

20 FOSSIL-FUELED POWER PLANTS↗

Unifying and benchmarking state-of-the-art quantum error mitigation techniques

Error mitigation is an essential component of achieving a practical quantum advantage in the near term, and a number of different approaches have been proposed. In this work, we recognize that many state-of-the-art error mitigation methods share a common feature: they are data-driven, employing classical data obtained from runs of different quantum circuits. For example, Zero-noise extrapolation (ZNE) uses variable noise data and Clifford-data regression (CDR) uses data from near-Clifford circuits. We show that Virtual Distillation (VD) can be viewed in a similar manner by considering classical data produced from different numbers of state preparations. Observing this fact allows us to unify these three methods under a general data-driven error mitigation framework that we call UNIfied Technique for Error mitigation with Data (UNITED). In certain situations, we find that our UNITED method can outperform the individual methods (i.e., the whole is better than the individual parts). Specifically, we employ a realistic noise model obtained from a trapped ion quantum computer to benchmark UNITED, as well as other state-of-the-art methods, in mitigating observables produced from random quantum circuits and the Quantum Alternating Operator Ansatz (QAOA) applied to Max-Cut problems with various numbers of qubits, circuit depths and total numbers of shots. We find that the performance of different techniques depends strongly on shot budgets, with more powerful methods requiring more shots for optimal performance. For our largest considered shot budget (10 10 ), we find that UNITED gives the most accurate mitigation. Hence, our work represents a benchmarking of current error mitigation methods and provides a guide for the regimes when certain methods are most useful.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward extreme high-temperature supercritical CO 2 power cycles: Leakage characterization of ceramic 3D-printed heat exchangers

We report future supercritical carbon dioxide (sCO 2 ) Brayton power cycles demand high-performance gas-to-gas heat exchangers (HXs) operating under extreme temperature and pressure conditions at which most existing superalloy materials fail to function safely. Ceramic HXs are deemed excellent candidates for advanced sCO 2 power plants as they can withstand high-temperature working environments. Particularly, ceramic 3D printing enables compact HX topologies employing complex and efficient heat transfer features. However, ceramic 3D-printed walls separating hot and cold flow streams are susceptible to a through-plane leakage inherent to a powder-based manufacturing process, including ceramic 3D printing. A potential leakage through ceramic separating walls poses a significant challenge in developing reliable ceramic 3D-printed HXs and could deteriorate thermal performance. In this study, various parameters, including feedstock slurry, 3D-printing direction, and post-processing conditions, are considered, for the first time, to characterize the argon gas leakage rate associated with alumina 3D-printed parts. Three 3D-printed ceramic structures of flat plates, curved tubes, and small-scale plate-and-frame HXs with various thicknesses are systematically studied to determine powder and ceramic 3D-printing conditions to eliminate the through-plane leakage. The results showed that an alumina 3D-printed plate with a thickness of 0.75 mm demonstrates a permeability of 6 x 10 -4 milli-darcy. An alumina 3D-printed tube with a wall thickness of 0.9 mm revealed a permeability of 9.6 x 10 -7 milli-darcy. Furthermore, leakage test results of functional 3D-printed modules showed a dependency on the 3D-printing direction. Particularly, alumina cell-scale HXs employing 1.5-mm-thick horizontal and vertical 3D-printed separating walls demonstrated impermeability and gas permeability of 7.2 x 10 -5 millidarcy, respectively. Insights gained from the present study facilitate the development of complex ceramic 3D-printed HXs and other balance of plant components for next-generation high-temperature high-pressure sCO 2 power cycles.

36 MATERIALS SCIENCE↗

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NEAR CRITICAL POINT TESTING AND PERFORMANCE RESULTS OF A SCO2 COMPRESSOR FOR A 10MWE BRAYTON CYCLE

Development and commercial acceptance of sCO2 Brayton cycles for power generation applications are growing rapidly as they offer performance advantages over other cycles. To maximize the cycle performance, the compressors are designed to operate near the critical point of the working fluid. At the critical point the fluid properties change rapidly with variations in inlet conditions. This makes it challenging to both accurately predict the performance and guarantee the operability of the compressor, as the behavior is affected by these slight variations in inlet conditions. A full scale 1st stage main compressor for a 10MWe-Class recompression Brayton cycle was built and tested to validate performance and operability in this unique operating range. The compressor was tested in a laboratory environment with additional instrumentation, beyond what is required by PTC-10, to minimize the uncertainty in the measured performance. Complete constant speed characteristics were collected at multiple supercritical points, operating at constant inlet conditions for each speed line covering a range of compressor inlet densities from 400 to 600 kg/m3. Variations in the compressor stage efficiency and choke margin were observed, and the overall operability and stability of the compressor in response to changes in operating condition were also monitored. The compressor was shown to have excellent performance that closely matched the original design prediction. The performance at various inlet conditions showed minimal change in isentropic head coefficient at the design flow, but did show some variation in efficiency and choke margin across the map. These changes in performance were observed to be minimal, and did not affect the stable operation of the compressor. The results demonstrate that a commercial scale sCO2 compressor can operate near the critical point and achieve the high levels of performance and stability required for power generation applications.

pelton, rob↗