Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polyethylene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Sampling of Trace Atmospheric Constituents Above the Surface of Mars from a Montgolfiere Balloon

We suggest that use of an aerially deployed, solar-heated balloon, or Montgolfiere, during a Martian polar summer could provide an optimal platform for atmospheric measurements near the surface. Solar Montgolfieres are empty balloons with a hole in the bottom that fill with ambient atmosphere while failing and are rapidly heated in by the sun, thus providing buoyancy. Such a balloon would be driven by the Martian winds in the constant sunlight of a high latitude entry and could provide a traverse of thousands of kilometers. It would encircle the Martian north polar region over a period,likely lasting over one earth month, and its altitude could be controlled as low as 100 meters to as high as 4000 meters above the surface. The significant payload of tens of kilograms allowed by this technology could readily accommodate the mass of instrumentation and the power source needed for a sensitive search for disequilibrium species that might provide the atmospheric signature of localized subsurface biological or geological activity. A mass spectrometer used in combination with gas enrichment techniques can provide sensitivities to sub parts per billion for several species of interest. Additional highly specific and sensitive detectors can search for other species or measurements of their mixing ratio variation along the path of the balloon. It would be useful to combine these atmospheric measurements with electromagnetic sounding to search for variations in subsurface conductivity that might indicate the presence of subsurface water. After a month of operation, the balloon could also soft land the DBMS to provide additional data on soil samples from a 1-2 meter subsurface drill. In order to float a 30-kg payload at altitudes between 100 m and 4000 m above the Martian north polar surface, an aluminized polyethylene Montgolfiere would be approximately 29 meters in diameter and have a mass of 27 kg. Altitude variations could be accomplished by means of an upper vent to release hot gas, as has been tested at JPL, or be means of a simple, internal winch mechanism to decrease the volume of the balloon. JPL has successfully deployed three polyethylene Montgolfieres at 4-6 mbar pressure in the Earth's stratosphere and will be deploying a 20-m diameter polyethylene Montgolfiere later in 2001.

Jones, Jack A.↗

Laboratory Analysis of Polymer Thin Films for Planetary Balloons and Gossamer Structures

Commercially available polymer thin fdms with thickness of 15 microns or less were evaluated for potential application as the gas envelope material of balloons and other inflated vehicles. Films on this thickness scale are of interest for Earth and Mars ballooning as well as many gossamer space structures. Due to the uniqueness of these missions relative to typical uses of these materials, application-specific materials properties measurements were made. We evaluated numerous polymer chemistries, plus a few variations within one chemistry. The data show that there are often trade-offs among the different materials, such as with polyesters and polyimides having greater stiffness (modulus) but lower tear propagation resistance than polyethylene. Sections of polyethylene films can be joined by heat sealing, while adhesives and their accompanying mass penalty must be used with polyesters and polyimides. When the analysis temperature is reduced to 190 K, polyethylenes display dramatically increased stiffness and yield point, while the increase for other materials is more modest. The data also show that manufacturing processes can significantly affect film properties. To emphasize the need for application-specific properties assessment, we discuss two recent applications using these materials.

Sterling, Jerry↗

Ultrasonic wave velocity measurement in small polymeric and cortical bone specimens

A system was refined for the determination of the bulk ultrasonic wave propagation velocity in small cortical bone specimens. Longitudinal and shear wave propagations were measured using ceramic, piezoelectric 20 and 5 MHz transducers, respectively. Results of the pulse transmission technique were refined via the measurement of the system delay time. The precision and accuracy of the system were quantified using small specimens of polyoxymethylene, polystyrene-butadiene, and high-density polyethylene. These polymeric materials had known acoustic properties, similarity of propagation velocities to cortical bone, and minimal sample inhomogeneity. Dependence of longitudinal and transverse specimen dimensions upon propagation times was quantified. To confirm the consistency of longitudinal wave propagation in small cortical bone specimens (< 1.0 mm), cut-down specimens were prepared from a normal rat femur. Finally, cortical samples were prepared from each of ten normal rat femora, and Young's moduli (Eii), shear moduli (Gij), and Poisson ratios (Vij) were measured. For all specimens (bone, polyoxymethylene, polystyrene-butadiene, and high-density polyethylene), strong linear correlations (R2 > 0.997) were maintained between propagation time and distance throughout the size ranges down to less than 0.4 mm. Results for polyoxymethylene, polystyrene-butadiene, and high-density polyethylene were accurate to within 5 percent of reported literature values. Measurement repeatability (precision) improved with an increase in the wave transmission distance (propagating dimension). No statistically significant effect due to the transverse dimension was detected.

Non-NASA Center↗

Polymer Energy Rechargeable System Battery Being Developed

Long description. Illustrations of discotic liquid crystals, rod-coil polymers, lithium-ion conducting channel dilithium phthalocyanine (Li2Pc) from top and side, novel star polyethylene oxide structures, composite polyethylene oxide materials (showing polyethylene oxide + lithium salt, carbon atoms and oxygen atoms), homopolyrotaxanes, and diblock copolymers In fiscal year 2000, NASA established a program to develop the next generation, lithium-based, polymer electrolyte batteries for aerospace applications. The goal of this program, known as Polymer Energy Rechargeable Systems (PERS), is to develop a space-qualified, advanced battery system embodying polymer electrolyte and lithium-based electrode technologies and to establish world-class domestic manufacturing capabilities for advanced batteries with improved performance characteristics that address NASA s future aerospace battery requirements.

Manzo, Michelle A.↗

Multi-functional layered structure having structural and radiation shielding attributes

A cosmic and solar radiation shielding structure that also has structural attributes is comprised of three layers. The first layer is 30-42 percent by volume of ultra-high molecular weight (UHMW) polyethylene fibers, 18-30 percent by volume of graphite fibers, and a remaining percent by volume of an epoxy resin matrix. The second layer is approximately 68 percent by volume of UHMW polyethylene fibers and a remaining percent by volume of a polyethylene matrix. The third layer is a ceramic material.

Kaul, Raj K.↗

Detecting strain in birefringent materials using spectral polarimetry

A method, computer program product and system for analyzing multispectral images from a plurality of regions of birefringent material, such as a polymer film, using polarized light and a corresponding polar analyzer to identify differential strain in the birefringent material. For example, the birefringement material may be low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene, polyethylene terephthalate (PET), polyvinyl chloride (PVC), polyvinylidene chloride, polyester, nylon, or cellophane film. Optionally, the method includes generating a real-time quantitative strain map.

Ragucci, Anthony J.↗

Non-Flammable Containment Bag and Enclosure Development for International Space Station Use

Work conducted on the International Space Station (ISS) requires the use of a significant quantity of containment bags to hold specimens, equipment, waste, and other material. The bags are in many shapes and sizes, and are typically manufactured from polyethylene materials. The amount of bags being used on ISS has grown to the point where fire safety has become a concern because of the flammability of polyethylene. Recently, a new re‐sealable bag design has been developed that is manufactured from a specialized non‐flammable material called Armorflex 301 that was designed specifically for this application. Besides being non‐flammable, Armorflex 301 is also FDA compliant, clear, flexible, and damage tolerant. The bags can be made with closure mechanisms that resemble ZipLoc® bags, or can be open top. Sample bags have been laboratory tested by NASA to verify materials properties, and evaluated by astronauts on the ISS in 2012. Flexloc bag manufacturing will commence in 2014 to support a transition away from polyethylene on ISS. In addition to re‐sealable bags, other larger containment systems such as flexible gloveboxes, deployable clean rooms, and other devices manufactured from Armorflex 301 are being explored for use on ISS and in similar confined space locations where flammability is an issue. This paper will describe the development of the Armorflex 301 material, the Flexloc bag, and other containment systems being explored for use in confined areas

Inamdar, Sunil↗

Preliminary Thermal Design of Cryogenic Radiation Shielding

Cryogenic Hydrogen Radiation Shielding (CHRS) is the most mass efficient material radiation shielding strategy for human spaceflight beyond low Earth orbit (LEO). Future human space flight, mission beyond LEO could exceed one year in duration. Previous radiation studies showed that in order to protect the astronauts from space radiation with an annual allowable radiation dose less than 500 mSv, 140 kgm2 of polyethylene is necessary. For a typical crew module that is 4 meter in diameter and 8 meter in length. The mass of polyethylene radiation shielding required would be more than 17,500 kg. The same radiation study found that the required hydrogen shielding for the same allowable radiation dose is 40 kgm2, and the mass of hydrogen required would be 5, 000 kg. Cryogenic hydrogen has higher densities and can be stored in relatively small containment vessels. However, the CHRS system needs a sophisticated thermal system which prevents the cryogenic hydrogen from evaporating during the mission. This study designed a cryogenic thermal system that protects the CHRS from hydrogen evaporation for one to up to three year mission. The design also includes a ground based cooling system that can subcool and freeze liquid hydrogen. The final results show that the CHRS with its required thermal protection system is nearly half of the mass of polyethylene radiation shielding.

radiation↗

Elastomer and Plastic Compatibility with a Pyrolysis-derived Bio-oil

The compatibility of fueling infrastructure elastomers and plastics in bio-oil and diesel fuel was determined by measuring the volume swell. The bio-oil was produced via fast pyrolysis of woody feedstocks. The elastomer materials included fluorocarbons, acrylonitrile butadiene rubbers, neoprene, polyurethane, neoprene, styrene butadiene (SBR) and silicone. The plastic materials included polyphenylene sulfide (PPS), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), polyoxymethylene (POM), POM copolymer, high density polyethylene (HDPE), polybutylene terephthalate (PBT), polypropylene (PP), polyethylene terephthalate glycol (PETG), polythiourea (PTU), four nylon grades, and four thermosetting resins. The majority of the elastomer and plastic materials exhibited higher volume expansion in bio-oil than in diesel. These elastomers and plastics had high polarity values which more closely align with the polarities of the bio-oil versus the diesel fuel. Conversely, SBR, silicone, HDPE, and PP are relatively nonpolar and this matches the low polarity of the diesel fuel, which resulted in higher volume expansion in diesel, rather than the bio-oil for these four polymers.

Kass, Michael↗

Elastomer and Plastic Compatibility with a Pyrolysis-Derived Bio-Oil

The compatibility of fueling infrastructure elastomers and plastics in bio-oil and diesel fuel was determined by measuring the volume swell. The bio-oil was produced via fast pyrolysis of woody feedstocks. The elastomer materials included fluorocarbons, acrylonitrile butadiene rubbers, neoprene, polyurethane, neoprene, styrene butadiene (SBR) and silicone. The plastic materials included polyphenylene sulfide (PPS), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), polyoxymethylene (POM), POM copolymer, high density polyethylene (HDPE), polybutylene terephthalate (PBT), polypropylene (PP), polyethylene terephthalate glycol (PETG), polythiourea (PTU), four nylon grades, and four thermosetting resins. The majority of the elastomer and plastic materials exhibited higher volume expansion in bio-oil than in diesel. These elastomers and plastics had high polarity values which more closely align with the polarities of the bio-oil versus the diesel fuel. Conversely, SBR, silicone, HDPE, and PP are relatively nonpolar and this matches the low polarity of the diesel fuel, which resulted in higher volume expansion in diesel, rather than the bio-oil for these four polymers.

09 BIOMASS FUELS↗

Sum-of-Fractions Method

Sum-of-fractions is a method intended to make sure a subcritical margin for aqueous solutions and slurries of fissionable isotopes exists. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope (in a mixture) to its individual minimum subcritical mass limit is less than or equal to one. Historically, the basis of the sum-of-fractions has been derived from allowances given in the American National Standards Institute (ANSI)/ American Nuclear Society (ANS)-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the sum-of-fractions for water- or polyethylene-moderated systems for the following nuclides: 232U, 233U, 234U, 235U, 237Np, 236Pu, 238Pu, 239Pu, 240Pu, 241Pu, 242Pu, 241Am, 242mAm, 243Am, 242Cm, 243Cm, 244Cm, 245Cm, 246Cm, 247Cm, 249Cf, and 251Cf. The methodology uses available benchmark data for mixtures of 233U, 235U, and 239Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water- or polyethylene-moderated and -reflected mixtures containing the nuclides are evaluated with the code system, SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water- or polyethylene-moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the keff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

criticality safety, Actinide↗

Evaluating Nationwide Supply Chain for Circularity of PET and Olefin Plastics

PET (Polyethylene Terephthalate, #1) and olefin plastics including HDPE (High Density Polyethylene, #2), LDPE/LLDPE (Low Density/Linear Low-Density Polyethylene, #4) and PP (Polypropylene, #5) together comprise nearly 80% of the U.S. plastic market. Due to their high market share and extensive application in packaging these polymers have better potential for circularity than other polymer types. To understand the potential of future scenarios with higher recycling rates, supply chain scenarios for PET and olefin plastic packaging need to be analyzed with increased availability and collection of plastics. Currently there exists a knowledge gap to understand the circular supply chain on a national level. Performing a nationwide analysis introduces certain challenges such as variability in the plastic mix of the recycling stream in different municipalities, lack of collection of some types of plastics, regional differences in cost and estimating a national supply curve based on state level access rate and participation rate. Currently, a limited number of Plastic Reclaimers recycle the nation’s collected plastic involving transportation over long distances surpassing state boundaries. Modeling a nationwide scenario instead of regional/state based scenario will facilitate transportation beyond state boundaries for the development of a circular economy. A Mixed-integer Linear Programming model was developed, to identify the optimal location and capacity of the Material Recovery Facilities (MRFs) nationwide subject to maximizing the profit margin of the industrial entities within the model. We considered three different scenarios including the base case scenario (S1) collecting 2.27 million metric tons/year as well as two additional scenarios with available plastic supply of 1.8 times (S2) and 2.2 times (S3) of the base case scenario. The model identified 166, 275 and 319 counties as potential MRF locations for scenarios S1, S2 and S3 respectively. Compared to the existing number of counties having MRFs in the US, the model results indicated a reduction of 38% of MRFs for S1. For S2 and S3, the number of counties with MRFs increased 3% and 20% respectively compared to counties currently with MRFs. The average profit remains constant between $180-$181/ton regardless of the increased plastic collection.

54 - ENVIRONMENTAL SCIENCES/GLOBAL CLIMATE CHANGE ↗

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNPS and MCNPX) codes is neutron shielding design. We employed this method to simulate the shield of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications. Nuclear reactors have been the main sources of neutrons used for scientific applications. In the past decade, however, a large number of reactors have been shut down, and the importance of other, smaller devices capable of providing neutrons for research has increased. At Brookhaven National Laboratory a moderated Am-Be neutron source with shielding is used for neutron detector testing. This source is relatively weak, but provides a constant flux of neutrons, even when not in use. The use of a 14 MeV energized neutron generator, with an order of magnitude higher neutron flux has been considered to replace the Am-Be source, but the higher fast neutron yield requires a more careful design of moderator and shielding. In the present paper we describe a proposed shielding configuration based on Monte Carlo calculations, and provide calculated neutron flux and dose distributions. We simulated the neutron flux distribution of our existing Am-Be source surrounded by a paraffin thermalizer cylinder (radius of 17.8 cm), 0.8 mm cadmium, and borated polyethylene as biological shield. The thermal neutrons are available through a large opening through the polyethylene and cadmium. The geometrical model for the MCNPS and MCNPX2 simulations is shown in Fig. 1. We simulated the Am-Be source neutron energy distribution as a point source having an energy distribution of four discrete lines at 3.0 (37%), 5.0 (35%), 8.0 (20%) and 11.0 (8%) MeV energies. The estimated source strength based on the original specifications is 6.6 {center_dot} 10{sup 6} neutrons/sec. The simulation accurately predicts the measured thermal neutron flux at the collimator (Figure 2), thus providing validation for this method. Using MCNPX we simulated the neutron and photon dose distribution and also obtained a good agreement with the measured values. Having established a validated framework for the shield calculation we then scaled up the Am-Be arrangement to simulate the shielding required for the higher neutron energy and flux of the neutron generator (-10{sup 8} neutrodsec at 14 MeV). Given the physical dimensions of the generator we have chosen a cylindrical geometry, where the generator tube is placed vertically into a cylindrical thermalizer (25 cm paraffin) from above. The thermalizer is surrounded by 0.8 mm cadmium, and a cylindrical borated polyethylene shield. A cylindrical opening (radius of 7.6 cm) serves to direct the neutrons out towards the experimental area (on the right side). The initial model is shown in figure 3. The first goal of the calculations was to establish the minimal required radius of the biological shield. For this purpose we performed MCNPX neutron and photon dose distribution calculations by tallying the absorbed dose on a 200 x 200 cm mesh in the vertical center plane superimposed over the geometry. Figure 4. displays the neutron dose distribution along the central horizontal (X) axis. As observed from the figure, a shielding radius of -80 cm is sufficient to obtain a dose level of < -4 mrem/hour outside the shield (except from the open neutron channel on the right). In the next step we studied the optimization of the thickness of the paraffin thermalizer by increasing the depth of the neutron exit channel into the paraffin cylinder. It was found, that the thermal flux greatly increases if we have thinner paraffin layer, an optimal value being about 5 cm thickness. But as a drawback the flux of fast neutrons also increased. A thicker thermalizer layer, in fact, acts as shielding. A slightly off centered, tangential placement of the neutron channel provides a solution which maximizes the thermal flux to fast neutron yield. Figure 5. and 6. display the final results, where we included an outside biological shield (20 cm thickness) providing a shielded experimental area. There is a 10-100 n/cm{sup 2}sec flux near the neutron beam exit, and outside the shield the neutron dose is below the radiation area limit (-5 mrem/hour).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Deformation of multilayer flexible electronics subjected to torque

Flexibility is one of remarkable characteristics of flexible electronics. Therefore, the analysis of flexible electronics deformation caused by external torques will help its design. In this work, analytical derivation is conducted for flexible electronics treated as multilayer structures. In experiments, an electric motor under computer control exerts a torque to generate torsion, whose twist angles are obtained by using both optical encoder measurement and theoretical calculation. Comparisons are made between experimental and theoretical results for bare PEN (polyethylene naphthalate) substrates of different sizes, multilayer PET (polyethylene terephthalate) substrates, and ITO (indium tin oxide)-coated PET substrates. Finally, a laser displacement sensor is used to measure the out-of-plane deformation for validating the proposed theoretical model.

36 MATERIALS SCIENCE↗

Generation of virtual monochromatic CBCT from dual kV/MV beam projections

Purpose: To develop a novel on-board imaging technique which allows generation of virtual monochromatic (VM) cone-beam CT (CBCT) with a selected energy from combined kilovoltage (kV)/megavoltage (MV) beam projections. Methods: With the current orthogonal kV/MV imaging hardware equipped in modern linear accelerators, both MV projections (from gantry angle of 0°–100°) and kV projections (90°–200°) were acquired as gantry rotated a total of 110°. A selected range of overlap projections between 90° to 100° were then decomposed into two material projections using experimentally determined parameters from orthogonally stacked aluminum and acrylic step-wedges. Given attenuation coefficients of aluminum and acrylic at a predetermined energy, one set of VM projections could be synthesized from two corresponding sets of decomposed projections. Two linear functions were generated using projection information at overlap angles to convert kV and MV projections at nonoverlap angles to approximate VM projections for CBCT reconstruction. The contrast-to-noise ratios (CNRs) were calculated for different inserts in VM CBCTs of a CatPhan phantom with various selected energies and compared with those in kV and MV CBCTs. The effect of overlap projection number on CNR was evaluated. Additionally, the effect of beam orientation was studied by scanning the CatPhan sandwiched with two 5 cm solid-water phantoms on both lateral sides and an electronic density phantom with two metal bolt inserts. Results: Proper selection of VM energy [30 and 40 keV for low-density polyethylene (LDPE), polymethylpentene, 2 MeV for Delrin] provided comparable or even better CNR results as compared with kV or MV CBCT. An increased number of overlap kV and MV projection demonstrated only marginal improvements of CNR for different inserts (with the exception of LDPE) and therefore one projection overlap was found to be sufficient for the CatPhan study. It was also evident that the optimal CBCT image quality was achieved when MV beams penetrated through the heavy attenuation direction of the object. Conclusions: A novel technique was developed to generate VM CBCTs from kV/MV projections. This technique has the potential to improve CNR at selected VM energies and to suppress artifacts at appropriate beam orientations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Triboelectric Nanogenerator Repeatability and Reproducibility Study

The development of triboelectric nanogenerators (TENGs) has largely focused on optimizing output performance, often at the expense of other critical research considerations such as the development of reliable technical procedures. In particular, the reliability of reported results—specifically repeatability and reproducibility—remains underexplored and is frequently limited to brief discussion within available literature. Without rigorous validation through repeatability and reproducibility studies, the credibility and broader applicability of reported findings remain uncertain. This study addresses this gap by systematically evaluating the repeatability and reproducibility of TENG performance data. Five polymer materials—Kapton, polyethylene (PE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyvinylidene fluoride (PVDF)—were investigated across all pairwise combinations of 25 total combinations for the reproducibility study and three selected pairs of the 25 samples were selected for the repeatability study. For each TENG pairing, we analyzed the methodology, experimental procedures, and resulting performance data to quantify consistency and reliability. The objective of this work is to assess the validity of the collected dataset and determine whether the observed performance trends are consistent for use in future TENG design and optimization studies. Establishing reliable and reproducible data is essential for advancing the development of high-output TENG systems and ensuring their dependable implementation in practical applications.

36 MATERIALS SCIENCE↗

Transmission Geometry Laser Ablation into a Non-Contact Liquid Vortex Capture Probe for Mass Spectrometry Imaging

RATIONALE: Capture of material from a laser ablation plume into a continuous flow stream of solvent provides the means for uninterrupted sampling, transport and ionization of collected material for coupling with mass spectral analysis. Reported here is the use of vertically aligned transmission geometry laser ablation in combination with a new non-contact liquid vortex capture probe coupled with electrospray ionization for spot sampling and chemical imaging with mass spectrometry. Methods: A vertically aligned continuous flow liquid vortex capture probe was positioned directly underneath a sample surface in a transmission geometry laser ablation (355 nm, 10 Hz, 7 ns pulse width) setup to capture into solution the ablated material. The outlet of the vortex probe was coupled to the Turbo V ion source of an AB SCIEX TripleTOF 5600+ mass spectrometer. System operation and performance metrics were tested using inked patterns and thin tissue sections. Glass slides and slides designed especially for laser capture microdissection, viz., DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides, were used as sample substrates. Results: The estimated capture efficiency of laser ablated material was 24%, which was enabled by the use of a probe with large liquid surface area (~ 2.8 mm2) and with gravity to help direct ablated material vertically down towards the probe. The swirling vortex action of the liquid surface potentially enhanced capture and dissolution of not only particulates, but also gaseous products of the laser ablation. The use of DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides as sample substrates enabled effective ablation of a wide range of sample types (basic blue 7, polypropylene glycol, insulin and cyctochrome c) without photodamage using a UV laser. Imaging resolution of about 6 m was demonstrated for stamped ink on DIRECTOR slides based on the ability to distinguish features present both in the optical and in the chemical image. This imaging resolution was 20 times better than the previous best reported results with laser ablation/liquid sample capture mass spectrometry imaging. Using thin sections of brain tissue the chemical image of a selected lipid was obtained with an estimated imaging resolution of about 50 um. Conclusions: A vertically aligned, transmission geometry laser ablation liquid vortex capture probe, electrospray ionization mass spectrometry system provides an effective means for spatially resolved spot sampling and imaging with mass spectrometry.

DIRECTOR slides↗

Coumarin-Rhodamine Hybrids—Novel Probes for the Optical Measurement of Viscosity and Polarity

A comprehensive systematic study of absorption and fluorescence properties in solvents of varying viscosity and polarity of three novel and red-emitting coumarin-rhodamine hybrid derivatives with differences in the rigidity of their substituents is presented. This includes ethanol-polyethylene glycol, toluene-polyethylene glycol, and toluene-paraffin mixtures. Moreover, protonation-induced effects on the spectroscopic properties are studied. A viscosity-induced emission enhancement was observed for all coumarin-rhodamine hybrid derivatives. MCR2 bearing a julolidine donor showed the expected low sensitivity to viscosity whereas MCR3 with its freely rotatable diphenylamino substituent revealed a particularly pronounced sensitivity to this parameter. Moreover, MCR2 shows an enhancement in emission in the open, i.e., protonated form in conjunction with a largely Stokes shift fluorescence in the deep red spectral region. This enables the application of these dyes as viscosity sensors and as far red emitting pH-sensitive probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗