Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

An airborne system for detection of volcanic surface deformations

A technique is proposed for measuring volcanic deformation on the order of centimeters per day to centimeters per year. An airborne multifrequency pulsed radar, tracking passive ground reflectors spaced at 1 kilometer intervals over a 50 square kilometer area is employed. Identification of targets is accomplished by Doppler and range resolution techniques, with final relative position measurements accomplished by phase comparison of multifrequency signals. Atmospheric path length errors are corrected by an airborne refractometer, meteorological instruments, or other refractive index measuring devices. Anticipated system accuracy is 1-2 cm, with measuring times on the order of minutes. Potential problems exist in the high intrinsic data assimilation rate required of the system to overcome ground backscatter noise.

Lunine, J.↗

Ultrastable reference frequency distribution utilizing a fiber optic link

The Frequency Standards Laboratory at the Jet Propulsion Laboratory (JPL) is responsible for the generation and distribution of ultra-stable reference frequency in NASA's Deep Space Network (DSN). Certain assemblies and components of the Radio Science and VLBI systems are located in the cones of tracking antennas hundreds of meters from the Frequency and Timing Subsystem's frequency standards. The very stringent requirements of these users challenge the performance of state-of-the-art frequency sources as well as the associated signal distribution system. The reference frequency distribution system described is designed around a low temperature coefficient of delay (TCD) optical fiber. On-site measurements of the fiber optic link alone indicate 100 MHz phase noise performance on the order of -120 dBc at 1 Hz from the carrier and Allan deviation on the order of parts in 10(exp 16) at 1000 seconds averaging time. The measured phase noise and stability of the link indicate that the performance characteristics of the hydrogen maser frequency standards are not degraded by the distribution system. Thus, optical fibers and electro-optic devices as distribution media appear to be a viable alternative to the classical coaxial cable distribution systems.

Calhoun, Malcolm↗

Size distribution and scattering phase function of aerosol particles retrieved from sky brightness measurements

Ground-based measurements of the solar transmission and sky radiance in a horizontal plane through the Sun are taken in several geographical regions and aerosol types: dust in a desert transition zone in Israel, sulfate particles in Eastern and Western Europe, tropical aerosol in Brazil, and mixed continental/maritime aerosol in California. Stratospheric aerosol was introduced after the eruption of Mount Pinatubo in June 1991. Therefore measurements taken before the eruption are used to analyze the properties of tropospheric aerosol; measurements from 1992 are also used to detect the particle size and concentration of stratospheric aerosol. The measurements are used to retrieve the size distribution and the scattering phase function at large scattering angles of the undisturbed aerosol particles. The retrieved properties represent an average on the entire atmospheric column. A comparison between the retrieved phase function for a scattering angle of 120 deg, with phase function predicted from the retrieved size distribution, is used to test the assumption of particle homogeneity and sphericity in radiative transfer models (Mie theory). The effect was found to be small (20% +/- 15%). For the stratospheric aerosol (sulfates), as expected, the phase function was very well predicted using the Mie theory. A model with a power law distribution, based on the spectral dependence of the optical thickness, alpha, cannot estimate accurately the phase function (up to 50% error for lambda = 0.87 microns). Before the Pinatubo eruption the ratio between the volumes of sulfate and coarse particles was very well correlated with alpha. The Pinatubo stratospheric aerosol destroyed this correlation. The aerosol optical properties are compared with analysis of the size, shape, and composition of the individual particles by electron microscopy of in situ samples. The measured volume size distribution before the injection of stratospheric aerosol consistently show two modes, sulfate particles with r(sub m) less than 0.2 microns and coarse paritcles with r(sub m) greater than 0.7 microns. The 'window' in the tropospheric aerosol in this radius range was used to observe a stable stratospheric aerosol in 1992, with r(sub m) approximately 0.5 microns. A combination of such optical thickness and sky measurements can be used to assess the direct forcing and the climatic impact of aerosol. Systematic inversion for the key aerosol types (sulfates, smoke, dust, and maritime aerosol) of the size distribution and phase function can give the relationship between the aerosol physical and optical properties that can be used to compute the radiative forcing. This forcing can be validated in dedicated field experiments.

Kaufman, Y. J.↗

Dynamic measurement of bulk modulus of dielectric materials using a microwave phase shift technique

A microwave Doppler shift technique was developed for measuring the dynamic bulk modulus of dielectric materials such as solid propellants. The system has a demonstrated time resolution on the order of milliseconds and a theoretical spatial resolution of a few microns. Accuracy of the technique is dependent on an accurate knowledge of the wavelength of the microwave in the sample being tested. Such measurement techniques are discussed. Preliminary tests with two solid propellants, one non-aluminized and one containing 16% aluminum, yielded reasonable, reproducible results. It was concluded that with refinements the technique holds promise as a practical means for obtaining accurate dynamic bulk modulus data over a variety of transient conditions.

Barker, B. J.↗

Radar Waveform Pulse Analysis Measurement System for High-Power GaN Amplifiers

This work presents a measurement system to characterize the pulsed response of high-power GaN amplifiers for use in space-based SAR platforms that require very strict amplitude and phase stability. The measurement system is able to record and analyze data on three different time scales: fast, slow, and long, which allows for greater detail of the mechanisms that impact amplitude and phase stability. The system is fully automated through MATLAB, which offers both instrument control capability and in-situ data processing. To validate this system, a high-power GaN HEMT amplifier operated in saturation was characterized. The fast time results show that variations to the amplitude and phase are correlated to DC supply transients, while long time characteristics are correlated to temperature changes.

high-power amplifier (HPA)↗

Improvements in X-band transmitter phase stability through klystron body temperature regulation

This article describes the techniques used and experimental results obtained in improving transmitter stability by control of the klystron body temperature. Related work in the measurement of klystron phase control parameters (pushing factors) is also discussed. The contribution of waveguide temperature excursions to uplink phase stability is presented. Suggestions are made as to the direction of future work in this area.

Perez, R. M.↗

Measurement and Simulation of Signal Fluctuations Caused by Propagation through Trees

We present measured magnitude and phase fluctuations of UHF, L band, and C band signals that were transmitted from the ground through a forest canopy to an airborne radar. We find that the measured fluctuations are similar to those calculated by a simple Monte Carlo simulation. Both observed and calculated RMS fluctuations are typically several decibels in magnitude and tens of degrees in phase at all three frequencies.

Durden, Stephen L.↗

Application of high stability oscillators to radio science experiments using deep space probes

The microwave telecommunication links between the earth and deep space probes have long been used to conduct radio science experiments which take advantage of the phase coherency and stability of these links. These experiments measure changes in the phase delay of the signals to infer electrical, magnetic and gravitational properties of the solar system environment and beyond through which the spacecraft and radio signals pass. The precision oscillators, from which the phase of the microwave signals are derived, play a key role in the stability of these links and therefore the sensitivity of these measurements. These experiments have become a driving force behind recent and future improvements in the Deep Space Network and spacecraft oscillators and frequency and time distribution systems. Three such experiments which are key to these improvements are briefly discussed and relationship between their sensitivity and the signal phase stability is described. The first is the remote sensing of planetary atmospheres by occultation in which the radio signal passes through the atmosphere and is refracted causing the signal pathlength to change from which the pressure and the temperature of the atmosphere can be derived. The second experiment is determination of the opacity of planetary rings by passage of the radio signals through the rings. The third experiment is the research for very low frequency gravitational radiation. The fractional frequency variation of the signal is comparable to the spatial strain amplitude the system is capable of detecting. A summary of past results and future possibilities for these experiments are presented.

Kursinski, Emil R.↗

Measurement of the Vertical Gradient of the Semidiurnal Tidal Wind Phase in Winter at the 95 Km Level

When supplemented by absolute reflection height measurements, low frequency wind measurements in the 90-100 km height range become truly competitive in comparison with the more widely used radar meteor wind observations. For example, height profiles of the wind parameters in the so-called meteor zone can be obtained due to the considerable interdiurnal variability of the average nighttime reflection heights controlled by geomagnetic activity. The phase of the semidiurnal tidal wind is particularly height-dependent. The measured vertical gradient of 1/4 h/km in winter corresponds to a vertical wavelength of about 50 km. Wind measurements in the upper atmosphere, at heights between 90 and 100 km, were carried out at the Collm Geophysical Observatory of Karl Marx University Leipzig for a number of years. These measurements use the closely-spaced receiver method and three measuring paths, on 179, 227, and 272 kHz. They take place every day between sunset and sunrise, i.e., nightly. A night in this sense may last as long as 18 hours in winter. Both the measurements and their evaluation are completely automatic, and the prevailing winds and tides are separated.

Schminder, R.↗

Study of low frequency hydromagnetic waves using ATS-1 data

An analysis was made of ATS-1 data to determine at what point in the magnetic storm recovery phase are oscillations most likely to begin. The catalog of hourly values of equatorial Dst was used to determine the time of main phase decrease, and a catalog of oscillations from January to May 1968 to determine onset time as observed by ATS-1. For each oscillation event at ATS-1, the nearest prior main phase decrease with a magnitude of at least -35 gamma was determined, and the time difference between the onset of the event at ATS-1 and the time of main phase decrease was measured. The resulting data indicate that the most probable time to observe onset of transverse oscillations is within 24 hours after the main phase decrease.

Cummings, W. D.↗

Acoustic ground impedance meter

A compact, portable instrument was developed to measure the acoustic impedance of the ground, or other surfaces, by direct pressure-volume velocity measurement. A Helmholz resonator, constructed of heavy-walled stainless steel but open at the bottom, is positioned over the surface having the unknown impedance. The sound source, a cam-driven piston of known stroke and thus known volume velocity, is located in the neck of the resonator. The cam speed is a variable up to a maximum 3600 rpm. The sound pressure at the test surface is measured by means of a microphone flush-mounted in the wall of the chamber. An optical monitor of the piston displacement permits measurement of the phase angle between the volume velocity and the sound pressure, from which the real and imaginary parts of the impedance can be evaluated. Measurements using a 5-lobed cam can be made up to 300 Hz. Detailed design criteria and results on a soil sample are presented.

Zuckerwar, A. J.↗

Acoustic ground impedance meter

A compact, portable instrument was developed to measure the acoustic impedance of the ground, or other surfaces, by direct pressure-volume velocity measurement. A Helmholtz resonator, constructed of heavy-walled stainless steel but open at the bottom, is positioned over the surface having the unknown impedance. The sound source, a cam-driven piston of known stroke and thus known volume velocity, is located in the neck of the resonator. The cam speed is a variable up to a maximum 3600 rpm. The sound pressure at the test surface is measured by means of a microphone flush-mounted in the wall of the chamber. An optical monitor of the piston displacement permits measurement of the phase angle between the volume velocity and the sound pressure, from which the real and imaginary parts of the impedance can be evaluated. Measurements using a 5-lobed cam can be made up to 300 Hz. Detailed design criteria and results on a soil sample are presented. Previously announced in STAR as N82-17476

Zuckerwar, A. J.↗

Millimeter wave surface resistance of grain-aligned Y1Ba2Cu3O(x) bulk material

Measurements are reported of the millimeter-wave surface resistance of grain-aligned YBa2Cu3O(x) bulk material grown by a liquid-phase process. The measurements were performed by replacing the endplate of a TE(011) cylindrical copper cavity with the superconducting sample. Surface resistance was measured for samples with surfaces oriented perpendicular and parallel to the c-axis of the grains. For the parallel configuration, the surface resistance at 77 K and 80 GHz is given. For a very well-aligned sample with a very low density of Y2BaCuO(y) precipitates, measured in the perpendicular configuration, the transition width (10-90 percent) is about 2 K and the surface resistance is derived at 88 K. The effect of microstructure on surface resistance is discussed.

Wosik, J.↗

A single bout of exhaustive exercise affects integrated baroreflex function after 16 days of head-down tilt

We tested the hypothesis that one bout of maximal exercise performed 24 h before reambulation from 16 days of 6 degrees head-down tilt (HDT) could increase integrated baroreflex sensitivity. Isolated carotid-cardiac and integrated baroreflex function was assessed in seven subjects before and after two periods of HDT separated by 11 mo. On the last day of one HDT period, subjects performed a single bout of maximal cycle ergometry (exercise). Subjects did not exercise after the other HDT period (control). Carotid-cardiac baroreflex sensitivity was evaluated using a neck collar device. Integrated baroreflex function was assessed by recording heart rate (HR) and blood pressure (MAP) during a 15-s Valsalva maneuver (VM) at a controlled expiratory pressure of 30 mmHg. The ratio of change in HR to change in MAP (delta HR/ delta MAP) during phases II and IV of the VM was used as an index of cardiac baroreflex sensitivity. Baroreflex-mediated vasoconstriction was assessed by measuring the late phase II rise in MAP. Following HDT, carotid-cardiac baroreflex sensitivity was reduced (2.8 to 2.0 ms/mmHg; P = 0.05) as was delta HR/ delta MAP during phase II (-1.5 to -0.8 beats/mmHg; P = 0.002). After exercise, isolated carotid baroreflex activity and phase II delta HR/ delta MAP returned to pre-HDT levels but remained attenuated in the control condition. Phase IV delta HR/ delta MAP was not altered by HDT or exercise. The late phase II increase of MAP was 71% greater after exercise compared with control (7 vs. 2 mmHg; P = 0.041).(ABSTRACT TRUNCATED AT 250 WORDS).

Randomized Controlled Trial↗

Measurement of the power spectral density of phase of the hydrogen maser

Hydrogen masers are being developed for the Deep Space Network as improved frequency standards, in order to achieve better timing accuracies, reduced Doppler residuals, and lower phase noise in the tracking system. Performance data for the masers are given in two forms: time domain performance, useful for analyzing time keeping systems and Doppler systems; and frequency domain performance, useful for analyzing tracking systems. Particular attention is given to frequency domain performance, as obtained from both time domain measurements and direct measurements.

Sward, A.↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Nondestructive ultrasonic measurement of bolt preload using the pulsed-phase locked-loop interferometer

Achieving accurate preload in threaded fasteners is an important and often critical problem which is encountered in nearly all sectors of government and industry. Conventional tensioning methods which rely on torque carry with them the disadvantage of requiring constant friction in the fastener in order to accurately correlate torque to preload. Since most of the applied torque typically overcomes friction rather than tensioning the fastener, small variations in friction can cause large variations in preload. An instrument called a pulsed phase locked loop interferometer, which was recently developed at NASA Langley, has found widespread use for measurement of stress as well as material properties. When used to measure bolt preload, this system detects changes in the fastener length and sound velocity which are independent of friction. The system is therefore capable of accurately establishing the correct change in bolt tension. This high resolution instrument has been used for precision measurement of preload in critical fasteners for numerous applications such as the space shuttle landing gear and helicopter main rotors.

Allison, S. G.↗

Effects and correction of magneto-optic spatial light modulator phase errors in an optical correlator

The optical phase errors introduced into an optical correlator by the input and filter plane magnetooptic spatial light modulators have been studied. The magnitude of these phase errors is measured and characterized, their effects on the correlation results are evaluated, and a means of correction by a design modification of the binary phase-only optical-filter function is presented. The efficacy of the phase-correction technique is quantified and is found to restore the correlation characteristics to those obtained in the absence of errors, to a high degree. The phase errors of other correlator system elements are also discussed and treated in a similar fashion.

Downie, John D.↗